halgan Aqua 204 HDPE Rainwater Storage Tanks halgan pty ltd features Halgan Aqua 204 HDPE Rainwater Storage Tanks Available in volumes between 5,000 L – 52,000 L 11 Tonne trafficable load rating © Halgan Pty Ltd 2014 2 • For underground installation and above ground • Available in volumes from 5.000 to 52.500 litres • Double-walled – especially robust • Components completely pre-assembled • Available in three equipment variants • Made of HDPE – lower weight than concrete and steel • Food-safe material • Maximum load: can be driven over by a truck (SLW 30 – 11,5 tons axle load) • Groundwater-stable up to body centre • Available with additional access manhole as inspection shafts from to 8.500 litres upwards • Intermediate sizes and inflows and outflows in DN 150 to DN 300 on request • Tank optionally couple able lengthways and sideways on request • Also available as a retention cistern – retention regulator • 10 years guarantee on the tank body applications • Retention tanks • Detention tanks • Horizontal pump stations • Vertical pump stations • Emergency Storage •Mines •Sewerage Rainwater | Complete Packages • | 13 | Construction site House package 2 | up to 350 m² roof area • Pre-treatment devices • Grease Arrestors • Cooling Pits + 1 • Lint Traps • COMPONENT S PACKAGE 2 Traps AcidHOUSE Neutralising + 2 + + 5 4 3 e.g. AQUA’TERNE 112, 5.600 litres 3 • AQUA’TERNE 112, 122, 135 or 204 ! • Sediment Traps • Pre-treatment Storage inc. riser with cap and childproof lock, calmed inlet and anti rodent siphon • Volume filter @ inc. telescopic extension • Swimming outlet # • Septic tanks • MiniMAX compact module $ with integrated pump, system control, automatic For filter function see p. 16 drinking water backfeed and fill level display • Set of labels % Rainwater storage with pump system. Type AT 112 AT 122 AT 135 AT 204 Art. no. Volume|l 2.700 31120085 5.600 8.200 31120086 31120087 10.500 31120088 2.000 31220085 3.000 4.000 31220086 31220087 5.000 7.500 31350126 31350127 10.000 31350128 5.000 8.500 32040186 32040187 Further volumes on request © Halgan Pty Ltd 2014 • applications Pressure pumps – schools, public areas – security 4 © Halgan Pty Ltd 2014 Rainwater Management Septic tanks – Sewerage treatment with baffles Gross Pollution Trap 5 © Halgan Pty Ltd 2014 Vertical Pump Stations specifications Sizes and weight © Halgan Pty Ltd 2014 6 • For underground installation and above ground • Available in volumes from 5.000 to 52.500 litres • Double-walled – especially robust • Components completely pre-assembled • Available in three equipment variants (• Made of HDPE – lower weight than concrete and steel • Food-safe material • Maximum load: can be driven over by a truck (SLW 30 – 11,5 tons axle load) - drivable cover (see p. 15) • Groundwater-stable up to body centre • Available with additional access manhole as inspection shafts from to 8.500 litres upwards • Intermediate sizes and inflows and outflows in DN 150 to DN 300 on request • Tank optionally couple able lengthways and sideways on request • Also available as a retention cistern – retention regulator • 10 years guarantee on the tank body Rainwater storage tank for volumes from 5,000-52,500 litres HALGAN INSTALLATION INSTRUCTIONS – AQUA STORAGE TANKS Please read carefully & adhere to the Scope of delivery / Equipment Rainwater storage tank for volumes from 5,000-52,500 litres installation instructions! (In case of multiple combinations- take Minimum one Halgan AQUA 204 assembled note of extra instructions!) as tank as: Screw-on tower shaft (Ø = 756mm) with Please read carefully & adhere to the Scope of delivery / Equipment Dear customer, connection possibilities (2x adapters and installation instructions! Congratulations on the purchase oftake your 2x muffs DN 100) and 204 seals, accessible (In case of multiple combinationsMinimum one Halgan AQUA assembled Halgan AQUAinstructions!) 204 tanks. Your AQUA 204 is as tank cover(green) as well as child safety lock note of extra as: a storage tank made from HDPE in the Screw-on towerDN shaft Quiet inlet 10 (Ø = 756mm) with extrusion blow-form method for the storage Dear customer, connection (2x adapters and with Overflowpossibilities outlet connection DN 100 Congratulations on the purchase your and usage of rainwater. Before of installing, 2x muffs 100) andanimal seals, accessible siphonDN and small protection Halgan tanks.ofYour AQUA 204that is cover(green) as well as child lock please AQUA check 204 for signs damage and Optional swimming outletsafety pipe 1” athe storage tank made from HDPE in the inlet DN 10 accessories are all complete. Installation Quiet Optional with integrated fine filter extrusion method for the storage outlet connection DN 100 with should beblow-form carried out by a suitably qualified Overflow Installation instructions, warranty certificate and usage company. of rainwater. Before installing, siphon and small animal protection specialist and product quality acceptance protocol please check for signs of damage and that Optional swimming outlet pipe 1” the accessories are all complete. Installation Optional with integrated fine filter should be carried out by a suitably qualified All dimensions in mm Installation instructions, warranty certificate specialist Inlet for company. model with filter (DN 100) // Inlet for model (DN acceptance 100) // Overflow (DN 100) andwithout productfilter quality protocol All dimensions in mm Inlet for model with filter (DN 100) // Inlet for model without filter (DN 100) // Overflow (DN 100) 7 Volume 1 1 Length Length Width Width Height without tower Height without tower Height with tower Weight Height with tower Weight © Halgan Pty Ltd 2014 Volume installation In addition, the floor of the pit, which must be free from stones and other sharp-edged objects, be prepared as flat, level load-carrying surface. We recommend laying a sand bed with grain size of approx. 5-10mm. Attention: if the pit floor is not strong enough, then an approx. 10cm reinforced lean concrete floor (D drawing 2) is to be cast. Where the floor is badly-drainable (clay), then suitable & sufficient drainage has to be provided! The tank is to be lifted with at least 2 lifting straps (not in scope of supply) and suitable lifting machinery (crane, excavator) and to be lowered into the pit evenly. After positioning and connecting, the tank is to be filled with water to 2/3 full (volume). © Halgan Pty Ltd 2014 8 Now, the space between tank and pit wall is filled with sand up to the height along the length of the inlet/outlet connections by washing-in the sand (C drawing 2). This must be performed manually. Important Instructions Halgan AQUA 204 tanks are designed to take the weight of 11.5 tons axle load limit when all installation conditions are adhered to. • The tower with cover is only built to carry persons and has to have a separate cover for heavier downward loads. • Installation in areas subject to flooding & groundwater is only permitted when the level of water does not exceed the height of the middle of the tank. This can, among others, lead to damage to the tank. • In areas of heavy, clay-like soils, the installation is only permitted when there is sufficient drainage underneath the body of the tank. • The Halgan AQUA 204 is designed for installation inside level ground. Where the ground inclines more than 8°, then a Civil engineer should be consulted. • Back material may only be compacted by hand-driven vibrating / compacting equipment 9 © Halgan Pty Ltd 2014 • Easy to transport EAS Y TO CLEAN SY E AC L E A N TO Improved and easy cleaning - Thanks to smooth inner wall EAS Y TO HANDLE • Low weight S Y LE E AH A N D • Simple installation TO ALL INCLU SI VE L AL IVE US CL IN 10 • Fast installation and maintenance GREEN PRODU CTI ON N E ET I O N R C G ODU PR © Halgan Pty Ltd 2014 • Accessories included – completely fitted • CO 2-friendly • Manufacturing processes without gas and oil Big Requirements Great Solutions © Halgan Pty Ltd 2014 11 12 halgan pty ltd halgan.com.au Halgan Pty Ltd ABN 69 064 448 157 © Halgan Pty Ltd 2014 22 Ethel Avenue Brookvale NSW 2100 PO Box 255 Collaroy NSW 2097 Freecall: 1800 626 753 Ph: Sydney 02 9972 1355 Fax: 02 9972 1455 Email: [email protected] Disclaimer Whilst all care has been taken in compiling this information and it is provided in good faith, it is not to be relied on as a substitute for professional advice. Halgan Pty Ltd accepts no responsibility for the accuracy, completeness or timeliness of the information. For more information contact your Halgan Pty Ltd
© Copyright 2026 Paperzz