Cedar Rapids IA, First Luth_ Organ with pictures

Report on the Organ
+ First Lutheran Church +
Cedar Rapids, Iowa
April 6, 2015
Report Purpose
The purpose of this report is to:
• Describe the current status, disposition and condition of the First Lutheran Church organ
• Report and comment on the possibility, feasibility and advisability of repairing, restoring,
and/or augmenting the current organ.
• Create a Specification or Specification Options for the repair, restoration, maintenance,
and possible augmentation needs of the current organ.
• Create an RFP ready for submission to qualified and experienced Organ Companies
inviting proposals and price quotations to accomplish the specified
repair/restoration/augmentation work
• Report and comment on the advisability of replacing the current organ.
• Create a Specification or Specification Options for the replacement of the current organ.
• Create an RFP ready for submission to qualified and experienced Organ Companies
inviting proposals and price quotations to install the specified replacement instrument.
THE FIRST LUTHERAN CHURCH ORGAN; A Brief Description
The organ at First Lutheran Church was built by the Levsen Organ Company of Buffalo, Iowa in
1983, Levsen Opus Number 4 (the 4th organ produced by the company). It has been since altered
from its original design and installation; some pipes and mechanisms originally installed on the
balcony railing have been moved to the upper-rear balcony wall alcove (to reduce the loudness
of the organ, as heard near the rear pews of the nave). Many, but not all, original electromechanical switches were replaced with solid-state electronic switches in 1996.
Current organ in balcony 2015
Page 2
The “organ” consists of pipes (which produce the musical organ tone), wind-chests (on which
pipes sit, and that contain the valve mechanisms to let wind into pipes), the “winding” and
“actions” (the methodology of getting pressurized air to the wind-chests, and the methodologies
of opening vales within the wind-chests, to allow pipes to sound), and the console (where keys,
pedals, and stops allow the organist to control the organ).
Organ pipes are crafted of either various metal alloys (zinc, tin, copper, lead, aluminum, etc.) or
wood species (poplar, pine, etc.). Their shapes (square, round, conical) produce varieties of tone,
akin to the wealth of tonal colors in a symphonic orchestra. Taller pipes produce low pitches,
and shorter pipes produce higher musical pitches. Just as an orchestra has multiple tonal families
(strings, brasses, woodwinds, percussion) at various pitch levels (low tubas to high piccolos), so
does a pipe organ have a variety of colorful voices in a range of dynamic levels, produced by the
many ranks of pipes.
Sample of current metal and wood organ pipes
These sonorities are intended to lead the singing of an entire congregation or assembly, to
accompany choirs and soloists, and to perform sacred organ repertoire (preludes, postludes,
processions, etc.). To accomplish these various musical tasks, the organ has four “tone
families”, designed for multiple primary and secondary musical uses.
These tone families and their prime functions are the Principals - for leading the singing of the
full assembly, and full solo/ensemble playing); the Flutes - for quieter hymns, accompaniments,
and softer passages; the Strings - for quiet & expressive playing; and, the Reeds - for solo
melodic and ensemble playing. The tonal families also produce sounds at a wide range of pitch.
(Bass for musical depth and accompanying singing in the men’s range – and Treble for melodies,
brilliance, and accompanying singing in the women’s range.) The First Lutheran Church organ
has pipes in all of the tone families.
Page 3
The organ operates by a unique “electro-mechanical” wind-chest valve action. Electromechanical actions employ low voltage DC current driven electro-magnets that move a felt and
leather valve “pad”. When the DC electro-magnet receives current (when a key is played at the
console) its internal magnet armature moves. This armature movement pulls the felt and leather
pad to “open” position….and wind (pressurized air within the air-tight wind-chest air box) enters
the pipe, causing it to sound (just as blowing air into a flute or clarinet causes those instruments
to sound). When the key is not being played, the electro-magnet armature can return to its “off”
position, returning the pad to “valve closed” position, and stopping the pipe from sounding.
Current pipe valves inside wind-chest
The pressurized air/“wind” in the organ is generated by an electric fan “blower”; the wind’s
pressure and flow/amount are controlled by a series of wind “regulators” (similar to bellows).
The electric fan blower is located in the music library/storage room adjoining the choir balcony.
The multiple wind regulators (bellows) are located within the blower room and pipe areas,
usually below the wind-chests and pipes. The blower, regulators, and wind-chests are connected
by air ducts.
Current wind-ducts and regulators
Page 4
The console is the “control panel” of the organ, and contains keyboards, stops, and pedals, for
the organist to play the instrument. No tone emanates from the console. The console cabinet
also contains its associated stop, key, and pedal electrical contacts and switches, and is located at
the left side of the balcony. The console is connected to the pipes via under-floor cables and
conduits.
Current console
All pipes, wind-chests, valves, wind lines, and electrical switches are located in the rear choir
loft/gallery area of the church, in two primary areas; one is the wooden “case” with silver
colored metal façade pipes, at the left of the balcony, next to the organ console and Sound
System control desk. The second is the alcove in the rear wall of the balcony, above and behind
choir singers. Some electrical switches and operating equipment is located within the console
and some nearer the pipes and wind-chests.
Current electrical switches (solid state)
Page 5
Existing Organ Technical Specification
Levsen Organ Opus 4, 1983
27 Registers, 36 Ranks, 37 Stop Controls
Electro-Mechanical (“Direct Electric”) Action
Great Organ (Manual 2), Pressure 3-7/8” w.g.
8’ Principal
8’ Holz Gedeckt
8’ Erzahler (Swell)
8’ Erzahler Celeste (Swell)
4’ Octave
4’ Koppel Flöte
2’ Fifteenth
IV Mixture
8’ Trompette
4’ Great to Great
16’ Swell to Great
8’ Swell to Great
4’ Swell to Great
16’ Positive to Great
8’ Positive to Great
4’ Positive to Great
Positive Organ (Manual 1), Pressure 3-7/8” w.g.
8’ Gedeckt
4’ Principal
4’ Wald Flöte
2’ Block Flöte
III Cymbal
8’ Krummhorn
Chimes
Harp
Cymbelstern (Volume, Speed, and Delay Control)
16’ Positive to Positive
Positive Unison Off
4’ Positive to Positive
8’ Swell to Positive
Page 6
Swell Organ (Manual 3), Pressure 3-5/8” w.g.
8’ Rohr Flöte
8’ Erzahler
8’ Erzahler Celeste
4’ Gemshorn
4’ Rohr Flöte (from 8’ Rohr Flöte)
2-2/3’ Nazard
2’ Principal
1-3/5’ Tierce
II Scharf
16’ Trumpet
8’ Trumpet (from 16’ Trumpet)
4’ Hautbois
Tremolo
16’ Swell to Swell
Swell Unison Off
4’ Swell to Swell
Pedal Organ, Pressure 3-1/2” w.g.
16’ Subbass
16’ Lieblich (From Subbass---with lower pressure); ext. from C13 from Swell 8’ Rohr Flöte
10-2/3’ Quint (from 16’ Subbass)
8’ Principal
8’ Pommer
4’ Choral Bass
III Mixture
16’ Trumpet (from Swell)
8’ Trompette (from Swell 16’ Trumpet)
4’ Clarion (from Swell 16’ Trumpet)
8’ Great to Pedal
4’ Great to Pedal
8’ Swell to Pedal
4’ Swell to Pedal
8’ Positive to Pedal
4’ Positive to Pedal
Console and Accessories
3 Manual draw-knob style
Crescendo Pedal
Swell Expression Pedal
8 General Pistons
5 Great Pistons
5 Swell Pistons
5 Positive Pistons
5 Pedal Pistons
8 General Toe Studs
4 Pedal Toe Studs
(Continued)
Page 7
General Cancel Piston
Great to Pedal Reversible Piston and Toe Stud
Swell to Pedal Reversible Piston and Toe Stud
Positive to Pedal Reversible Piston and Toe Stud
Sforzando Reversible Piston and Toe Stud
Cymbalstern Reversible Toe Stud
MIDI System
Sequencer
Blower
Dayton Motor
2 H.P.
3450 RPM
115/230 Hz
Rectifier
La Marche
In-put: 240V, 1 phase, 17 Amp, AC
Out-put: 10-15V DC, 50 Amp
Switching System
Peterson
Page 8
Organ Repair and Maintenance Needs
While the organ is currently substantially functional and playable, many operations and functions
are unreliable. It is suffering a number of continually worsening mechanical, physical, and tonal
defects which will increase in severity and cost to maintain or to attempt to rectify over time.
There are critical defects and deterioration in all of the organ’s systems and areas. These include
the following “large scope” issues that make the organ both difficult for an organist to control
and play, and which limit the quality and authentic scope of liturgical music available to the
congregation:
• Leaning/bending/collapsing pipes
• Deteriorating gaskets and wind leaks
• Unreliable electrical switches and motors
• Worn out console keyboard and pedal actions, felts and springs
• Pipes that will not reach or maintain proper speech, balance, tuning and pitch
• Dead notes
• Inaccessible (or difficult/expensive/time-consuming to access) mechanisms and pipes
• Non-standard or compliant console dimensions and layout
• A musical and tonal scheme that is unbalanced, with incorrect power/volume ratios,
poorly regulated, and that lacks important musical resources that are necessary to render
the historic and current liturgical and sacred musical literature of the (Lutheran) Church.
This organ suffers primarily from fundamentally and inherently low grade materials,
workmanship, and design engineering. This is likely due to the fact that the manufacturer lacked
the scope and depth of experience, having built only three instruments prior to this one. Each of
the following features and elements contribute to a collectively poor musical rendition and
unacceptable mechanical and functional operative reliability. Specifically:
1. Electro-mechanical (“DEA”) Pipe Valve Actions: These valves permit wind into pipes in
a manner that is both abrupt and without adequate pressure control. As a result, pipes
receive inconsistent wind supply, and therefore cannot have tonal or tuning consistency
or reliability. While the “DEA” valves are inexpensive to purchase, they are costly in
terms of causing unstable tone and frequent tunings.
2. Inaccessible Pipe Layout: Many pipes cannot be accessed (or many parts/pipes need to
be disassembled or moved away) for tuning or regulation; tuning and servicing is
therefore costly and unreliable.
Page 9
3. Poor Engineering Layout:
o Many mechanisms and features of the organ are difficult to access, or require the
disassembly of adjoining components to gain access.
o The proximity and location of many pipes creates situations of poor tonal balance
or blend, and tonal interference.
o In the case of the pipes located at the upper rear alcove behind the choir loft; the
mechanisms controlling these pipes are only accessible by removing ceiling tiles
from the 2nd floor building hallway; this is time consuming and disruptive to
servicing and maintenance. Further, hallway and structural features prevent full
access.
o There is inadequate support and racking for many components and pipes, causing
damage and collapse of pipes and parts.
o The winding system and wind-ducts are installed in an unorganized and
haphazard manner; wind supply is unstable and inadequate, causing pitch and
tone fluctuations
4. Inappropriate Materials: Many of the raw materials used in the construction of this
instrument are poorly selected. Problems include:
o Dimensional instability of wood types (example-coniferous varieties) causing
cracks, leaks, and unstable tuning.
o The use of unsuitable metals which can have weak structural stability and poor
tonal resonance. (Example; Aluminum pipes which cannot be adjusted as
precisely as other metals, and which do not produce full resonance)
o Inappropriately used lead pipe toes that collapse under their own weight
o Tin/lead alloys that are inherently weak, causing bending and collapse
o Zinc pipe resonators that impart dissonant tonal harmonics
o Weak and thin metal tuning scrolls prone to tearing
o Poor material uses also negatively affect the console actions and electrical
systems of the organ;
o Too thin key and Pedal felts compress and wear
o Electrical contacts burn, break, and corrode
o Too thin cork and leather gaskets dry, decay, and compress, causing leaks
o Plastic parts crack and break
5. Poor Tonal Design: The pipe-rank choices, wind pressure, pipe scales, and voicing
techniques employed are incorrectly selected for the purpose of achieving well developed
tone for Lutheran liturgical use or for the church’s room size:
o Tone can be excessively loud near to pipes in balcony, but tone is unevenly
projected to the nave.
o Volume levels are uneven throughout all ranks
o Tone balance and blend is uneven throughout all ranks
o Tuning is unstable, especially in trebles and reeds
o Voicing style is “neo-Baroque”, but miss-applied for the size of room and
acoustic setting (too treble-aggressive and articulate)
o Musical elements important to Lutheran liturgy and literature are lacking (i.e.,
Reed Choruses, Balanced Mutations/Cornets, independent 8’ & 4’ ranks, and
dynamic expression for the Choir division, etc.).
Page 10
6. Console inadequacies: Organ consoles should conform to the American Guild of
Organists “Standards” for layout, location of controls, and dimensions. The standards
are developed for the purpose of facilitating accurate playing, and reliable identification
and use of all organ controls.
o This console does not comply to AGO “Standards”
o Controls are difficult to identify, reach, or operate.
o Components are poorly made and unreliable
o Functions are noisy and slow to operate
Current Status Defects and Repair Work List (as of March, 2015):
1. Dead Notes:
a. Great 4’ Octave, A#59
b. Great 2’ Fifteenth, G8, A#47
c. Swell 2’ Principal, G20
d. Swell II Scharf, A46
2. Failing Control/Actions:
a. All General Pistons (esp. note Gen. #7)
b. Positive to Pedal 8’ Coupler knob
c. Positive Harp; Dead
d. Pedal 10-2/3’ Quint F30, sticking action
e. Some switching changed to solid state in 1996—portions remain as electromechanical switches; incompatible
3. Un-regulated tone/voicing:
a. Great 4’ Koppel Flöte, Action noise G44 to C61
b. Great 8’ Trompette, Reed to Flue transition unbalanced
c. Great 8’ Trompette, poor regulation, tuning, speech throughout
d. Positive 4’ Principal, D27, D#28, E29 mouth interference
e. Positive 4’ Wald Flöte, B36, C37, C#38 mouth interference
f. Positive 4’ Wald Flöte, excessive wind in regulation Bass and Treble octaves
g. Positive 2’ Block Flöte, uneven volume regulation, C37 to C49
h. Positive 8’ Krummhorn, poor regulation, tuning, speech throughout
i. Swell 4’ Rohr Flöte, uneven volume regulation throughout
j. Swell II Scharf; no pitch breaks
k. Swell 16’ Trumpet (ext. to Swell 8’, 4’, and Pedal 16’, 8’ 4’), poor regulation,
tuning, speech throughout
l. Swell 4’ Oboe, too loud, poor regulation, tuning, speech throughout
m. Pedal division pipes at different locations throughout organ; no tonal or tuning
compatibility or unity
n. Aluminum Pipes cannot be reliably or stably voiced or tuned
o. Wind-pressure is too low to achieve proper pipe tone, speech or tuning stability
Page 11
4. Console defects:
a. Un-regulated and failing key/spring actions
b. Failed/compressed manual key felts
c. Un-regulated and failing pedal key/spring actions
d. Failed/compressed pedal key felts
e. Un-adjustable key contacts
f. Failed pedal contact blocks
g. Uneven key-bed
h. Inadequate combination action/piston memory and sequencing systems
5. Pipe Condition:
a. Reed resonators bending/collapsing
b. Reed tongues corroded
c. Cracked wood pipes
d. Decaying wood pipe tuning gaskets
e. Metal toes of wood bodied pipes bending/collapsing
f. Torn tuning scrolls
6. Inadequate tonal resources (missing ranks important to Lutheran liturgical musical
literature include):
a. Great 16’ Flue
b. Great Mutations/Cornet
c. Great Chorus Reeds
d. Swell independent 8’ and 4’ Flutes
e. Swell 1-1/3’ pitch
f. Swell 8’ Oboe
g. Swell 16’ Flue
h. Swell Chorus Reeds
i. Positive Mutations/Cornet
j. Positive (or Choir division) dynamic expression
k. Pedal 16’ open Flue
l. Pedal Chorus Reeds
m. Pedal 4’ Flute
n. Pedal 32’ pitch options
Page 29
Conclusion
The First Lutheran Church organ exhibits problems, poor operation, and poor performance in all
primary parameters. The instrument is:
A. Mechanically and physically unreliable and defective
B. Functionally inadequate to support and serve the music program and liturgy
C. Musically and acoustically defective and inadequate
The causes of these problems and defects are not due to abuse, damage or poor maintenance. In
fact, very little apparent abuse or externally sourced damage (i.e., vandalism, accident, roof-leak,
etc.) has befallen the instrument. Further, the maintenance the organ has received in recent years
(tuning and best effort repairs) has been carefully and responsibly done.
The causes of these problems and defects are due to fundamental flaws in the design, materials,
and craftsmanship applied when the instrument was created. A pipe organ built of careful design
and engineering, from appropriately selected and compatible raw materials, assembled in an
experienced, workman-like, and artistic manner, should function reliably for decades and
centuries. Indeed, example organs built over 400 years ago still function regularly in the service
of their congregations. This instrument is in distress due primarily to its inherent design and
manufacture, and not due to any critically poor or deferred maintenance. The defects are beyond
the stage of needing “adjustment”.
Comparative description and evaluation of solution options:
The practical options available for dealing with a faulty and unreliable instrument are the
following:
1. Repair, rebuild, restore, and possibly augment the existing instrument (or employ the
“best” components of the existing organ into a replacement instrument scenario)
2. Replacement with another pre-existing/heritage/used instrument
3. Replacement with a new instrument
Page 30
Option 1; Repair, rebuild, restore and/or augment the existing organ
The challenge in this option is that the roots of the organ’s defects are fundamental and deep,
more akin to “rust and decay” in an older automobile than to an automobile needing new tires
and an oil change. Further, due to the labor intensive nature of extensive organ repair work of the
type needed for this instrument, costs for repair may meet or exceed the cost of replacement.
Prototype Repair Work-list/Specification
1. Repair and straighten all bent and collapsing pipes
2. Add stiffening rods to all 8’ and longer reed resonators
3. Provide new racks for all pipes
4. Provide double and triple multi-level racks for all 8’ and longer reed resonators
5. Replace all wood pipe stopper gaskets
6. Repair all cracked wood pipes
7. Replace all aluminum pipes with tin/lead alloy or zinc pipes
8. Repair all reed resonator scrolls
9. Replace all flue pipe scrolls with sleeve tuners
10. Replace all reed tongues
11. Replace current 4’ Oboe with new 8’ Oboe rank
12. Re-voice and tone regulate all ranks
13. Lubricate all DEA valves
14. Replace all wind-chest and flange gaskets
15. Replace console
16. Replace electrical switching and operating system
17. Repair, re-leather and re-engage Harp action
18. Recover all regulator pneumatics
While this repair list will address a large number of current defects, the following problems
cannot be “repaired” because these problems are fundamental and inherent to the substance of
the current organ. These “un-repairable” problems include:
1. Pipe tone and tuning stability cannot be fully improved due to the limitations of the DEA
valves and wind pressure
2. Accessibility for maintenance and tuning cannot be improved due to the layout and
location of equipment
3. Protection against future dead notes cannot be fully accomplished due to the type of DEA
valves used
4. Musical blend, balance, and tonal improvements cannot be substantially achieved due to
the selection, materials, wind-pressure, and scaling of the current pipes
5. The proximities and placement of current pipes cannot be improved due to the design and
engineering layout of the organ
6. There is no space for any augmentations or additions due to the layout and engineering
design of the instrument
7. Future maintenance and tuning costs and needs cannot be substantially reduced due to the
engineering layout, access challenges, and original material quality employed
8. The same forces that led to the current defects will re-occur in the same way after repair,
requiring future repeated repairs for many items
Page 31
9. It should be noted that the current (low) quality grade of engineering, materials, and
workmanship of the existing equipment precludes the use of any current parts into a
worthwhile, durable and credible revision or replacement scenario.
Conclusion:
• Repair of some components and features is possible
• Repair of some inherent design, engineering, and components/materials is not possible
• Many repairs will be short term, and require repair again
• The current engineering and layout prevents any upgrades or augmentation
• Most major, experienced, and credible organ companies will not take on this repair job
• Potential Estimated Cost of attempted Repair: $500,000.00 to $600,000.00
Page 32
Option 2; Replace the organ with another pre-existing/heritage/used instrument
Many well built durable instruments with artistic and musical integrity become available for sale
“used” from time to time. Some “used” organs are offered for sale because they are problematic
and defective. Other “used” and worthwhile heritage instrument also become available for sale
due to such factors as church mergers, expansions, or closings. An available used organ can
easily be inspected and evaluated regarding its suitability for First Lutheran Church. It should be
noted that a prospective purchaser of a good used organ must be capable of making an offer to
purchase relatively quickly; good used instruments are searched for and desired by many, so they
do not remain on the market for a long time. A relocated heritage/used organ project can
typically cost only half of an equivalent new organ. If funds are not immediately available to
purchase a used organ and have it restored and installed, the instrument can be purchased and
placed into storage until restoration and installation funds are available.
The challenge in finding a used/heritage organ appropriate for First Lutheran Church will be the
limited space available in the balcony for an organ. The balcony ceiling height is relatively low,
and the floor space available for an organ is somewhat limited due to the space also needed for
choir singers, bell ringers, and instrumentalists. Re-locating the music ministry to the front of
the church (behind the Altar area) would relieve some of this challenge, because of the greater
ceiling height. So, it may be difficult to find a “fitting” used organ because of the limited and
unique geometric space available in this building. Used and heritage organs can be costly if
significant re-configuration and re-engineering is necessary; they are most economically
relocated “as is”.
A used heritage organ of genuine historic quality will be able to draw good
musicians/staff/volunteers into the music ministry of the parish, and can inspire listeners and
worshippers
Conclusions:
• A used/heritage organ can be worthwhile---musically and technically, and with a long,
durable life-span
• A used/heritage organ can be cost effective---possibly costing less than half of equivalent
new
• It may be quite difficult to find a used/heritage organ that will fit into the architectural
space available at First Lutheran Church
• Good heritage organs are in great demand; a purchase may need to be accomplished in
short time
• A used/heritage organ can be purchased and stored until restoration and installation funds
are available
• Possible cost range: $550,000.00 to $750,000.00
Page 33
Option 3; Replace the organ a new instrument
The purchase of a new organ allows maximum potential to meet the musical goals for a
congregation. A new instrument can be custom designed to fit into the physical and architectural
parameters of the building and its acoustic environment, and to meet the specific dynamic artistic
and musical needs of a congregation; the congregation’s liturgical, musical, and functional goals
can be specifically met. Typically such goals include:
1. A tonal palette fitting the liturgical and musical traditions, as well as future and flexible
practices of the parish
2. A tonal palette appropriate to the architectural and acoustic worship space/size
3. Mechanical and technical durability and reliability
4. Low maintenance needs and costs
5. A visual and aesthetic presence fitting the building’s architectural style
6. Cost effective value in purchase price and for long term service
7. Able to draw good musicians/staff/volunteers into the music ministry of the parish
8. Able to inspire and draw listeners and worshippers
These goals can be achieved with cost control in mind, but sufficient funds are required to
achieve quality and durability. The “no free lunch”, and “you get what you pay for” principles
of cost vs. quality indeed apply in the organ industry. Over time, a high quality instrument will
cost a parish the least, due to a long and durable life span and low maintenance costs and needs.
Many organ builders will have available or offer the incorporation of good “used” heritage parts
or pipes within an otherwise “new” instrument. This can be a worthwhile opportunity, because it
can lower costs while maintaining quality, and can conserve natural and artistic resources.
Some churches may consider purchasing “part” of a new organ, with preparations and space
reserved for future additions as an attempt at cost control. This scheme is not recommended,
because if and when left un-completed, the instrument cannot fulfill its intended functions; all
too often the “future” completion never happens, and the parish’s liturgy and music suffer
permanently. Further, all delayed purchase of parts will cost significantly more in the future.
Conclusions:
• A new instrument will maximize custom design to meet a parish’s unique functional,
musical, and architectural needs.
• A new instrument can be cost effective---offering the greatest possible durable life span
and artistic/aesthetic draw
• A new instrument will have a higher purchase price
• A new instrument will cost the least over time due to long life-span and low maintenance
needs
• Purchasing an entire new organ (not preparing/delaying some components for future
purchase) is recommended to assure the functional and musical integrity and use of the
organ and to reduce future costs
• Possible cost range: $870,000.00 to $1,900,000.00
Page 45
Notes for next activities/action points by committee
1. Recommended Process:
a. Establish need for organ repair or replacement
b. Thorough study of all options
c. Recommendation/Selection of most appropriate solution for congregation
d. Communicate to leadership and membership
e. Support and funding options/plan
2. Decision Points:
a. Balcony or Front of Church music ministry/organ location
b. Acoustic and spatial improvements
c. Rebuild/Repair or Replacement
d. New or Heritage/used
e. Organ design/action/type selection
f. (Digital or Hybrid)
3. Fund Raising:
a. Funding plan
b. Funding sources