Red values are those that do not meet the water quality criteria Objective for the specified parameter. The Objective is a Water Quality Index that helps to
identify the environmental health condition of a water body. Objective values are either minimum or maximum goals to be aimed as a water quality criterion
for the SJBEP. Some of these objectives were obtained after evaluating a year of water quality data.
Date
Hydrolab Quanta
Jan-11 Feb-11
Mar-11 Abr-11 May-11 Jun-11 Jul-11 Aug-11 Sep-11
Objective Average
Temperature C°
26.43
26.37
26.33
28
29.56
30.6
29.58
28.8
30.88
1.31
2.46
2.17
0.81
*
3.11
3.8
3.93
6.63
Dissolved Oxygen ( %)
18.1
24..5
30.2
11.2
*
44.8
41.8
53.2
63.8
Specific Conductance (mS/cm)
24.2
30.1
31.8
28.6
17.2
14.6
12.08
4.29
18.3
Salinity (PSS)
14.76
19.14
19.76
17.88
9.97
8.51
6.92
2.29
16.04
Turbidity (NTU)†
6
3.8
4.7
13.8
0
1.7
3.5
*
2.8
pH†
7.71
8.52
8.9
7.83
7.92
6.6
7.21
6.75
7.72
Secchi Depth (Meters)•
1.71
0.69
1.24
0.66
1.3
1.63
1.13
1.08
1.39
Time
9:12
10:48
9:59
10:01
10:13
10:25
10:11
11:04
10:08
Dissolved Oxygen (mg/L)
†
≥5
< 10
6.0-9.0
≥1
Laboratory results
Oil & Grease (mg/L) •
BDL
BDL
Total Kjeldahl Nitrogen (mg/L) †
0.68
0.93
Nitrate & Nitrite,total (mg/L) •
0.09
0.11
Total Phosphorus (mg/L) †
0.272
0.930
TOC (mg/L) •
4.670
3.52
Chlorophyll a (mg/m3) •
30.100
13.50
Turbidity (NTU)
22
5.2
Ammonia (mg/L)
0.19
0.44
BOD (mg/L)
11
2
Coliform-Fecal (CFU/100mL)†
2000
300
Fecal Enterococcus (CFU/100mL)†
90
54
ˆ TSS (mg/L)
Sample Number
1668270
*Hydrolab Quanta was not available
† PR Water Quality Standard Regulation, Evironmental Quality Board, Act 7832, March 31,2010.
• This parameter objective is not regulated by PRWQB.
ˆ(TSS: Total Suspended Solids, May and August)
BDL: Below Detection Limit
1753080
www.estuario.org
San Juan Bay Water Quality Monitoring Program
[email protected]
<1
<1
<1
< 0.5
<5
<5
<5
< 200
< 35