1. Laser power meter head for CW lasers S No specification Value 1 2 3 4 5 6 7 8 9 10 Sensor type Sensor shape Energy range wavelength range Active area diameter Maximum Average Power Density Thermopile sensor circular ≤300 mW to ≥ 150 W ≤250 nm ≥1100 nm ≥ 50 mm ≥ 6 kW/cm2 Calibration Wavelength Calibration Uncertainty Response time Detector Coating 532 nm or near standard wavelength (±10%) ±1% or better ≤ 5 sec Broadband, matching with the detection wavelength range Air cooled If required, the same should be supplied with energy meter The detector heads must be calibrated from standard (NIST traceable) sensors. 12 months against manufacturing defects 11 Cooling 12 Heat sink 13 Certification 14 Warranty 2. Laser energy meter head for pulsed lasers S No specification 1 2 3 4 5 6 7 8 9 10 Sensor type Sensor shape Energy Range Noise Equivalent Energy Wavelength Range Active Area Diameter Maximum Average Power Maximum Pulse Width (output) Maximum Rep. Rate Maximum Energy Density 11 Detector Coating 12 Diffuser 13 Calibration Wavelength 14 15 16 17 1 No. Calibration Uncertainty Energy Linearity Cooling Heat sink 18 Certification 1 No. Value Pyroelectric sensor circular ≤500 µJ - ≥1 J <16 µJ ≤200 nm ≥1100 nm 50 mm 20 W ≤ 2 µs ≥ 1 kHz 500 (mJ/cm2) (for 1064nm, 10ns) Diffuse Metallic No at any one of these two wavelengths 1064 nm ± 10% or 800 nm ± 10% +/- 2% or better +/- 3% or better Air If required, the same should be supplied with energy meter The detector heads must be calibrated from standard (NIST traceable) sensors. 19 Warranty 12 months/ 1 year against manufacturing defects or more 3. Laser energy/power meter (Reader) S No specification 1 Compatibility 2 3 4 5 6 7 8 Input Range Measurement Resolution Max Repetition Rate (Hz) Power Sampling Rate Accuracy (Digital Meter) Accuracy - System Display 9 Statistical Analysis 10 11 12 13 14 15 16 Computer Interface Instrument Power Battery Temperature (Operating) Power adapter Wavelength Selection Threshold/Trigger 17 Warranty 18 Auto configuration 1 No Value The reader must be compatible with both the laser power meter heads at item 1 and 2 Should be compatible with supplied heads 0.1% of full-scale 10,000 sampling (1,000 Hz every pulse) 10 Hz ±1.0% of reading Meter accuracy + sensor accuracy larger or equal to 110 x 75 mm backlight graphic LCD/LED, resolution 480 x 320 pixels or better. Adjustable contrast and viewing angle Following functions are necessary. Minimum, maximum, mean, range, standard deviation, energy dose, stability, Trend charting, positional display, analysis of beam stability USB and RS-232 should be working on 220 VAC, 50 Hz ≥ 4400 mAH Li-ion battery 5°C to 40°C or near standard must be Included Menu selectable There must be a provision of threshold/ trigger to minimize the noise in the measurement 12 months against manufacturing defects The meter must auto configure the head upon connection Notes 1 There will be no part shipment 2 all the manuals must be supplied with the item
© Copyright 2026 Paperzz