DBC2037F1V1 1-2 | CROSS BAND COUPPLER, 700/8500/900 & AWS//PCS W/INTEGRATED MO ONITOR PORT T & AISG MOD DEM WIN UNIT TW The Kaelus DBC2037F1V V1-2 cross ban nd coupler com mbines the lower 69 98 to 960MHzz frequency ba ands with the higher AWS/PCS ffrequency band ds. Used to minimize infrastrructure capital expe nditure and im proving networrk reliability. PRODU UCT FEA ATURES - LTE L ready - Integrated AIS SG modem & m monitor port - Auto A select DC C/AISG pass wiith built-in lightning l protec ction - Single or twin n configurationss available for iindoor or outdoor usse - AISG A port DC takes t priority over o HI and LO ports, p HI port ta akes priority ov ver LO port TECHN NICAL SP PECIFICA ATIONS | | 700/85 50/900MHz CHANNEL L (LO) Passband d 69 98-960MHz Insertion loss 0.15dB max, 0.1 1dB typ Return los ss all ports 24 4dB typ Phase linearity variation n 0.1° max over an ny 180kHz with hin the passban nd Group de elay variation 0.1ns max over a any 180kHz wiithin the passba and Maximum m average inputt power 50 00W Maximum m PEP input pow wer 50 000W |1| © 2014 Kaelus. All Rights Resserved. ww ww.kaelus..com D DBC2037F1V1-2 ISSUE A TECHN NICAL SP PECIFICA ATIONS CONTINUE C ED | | AWS/P PCS CHAN NNEL (HI) Passband d 17 710-2170MHz Insertion loss 0.15dB max, 0.1 2dB typ Return los ss all ports 24 4dB typ Phase linearity variation n 1°° max over anyy 180kHz within n the passband d Group de elay variation 0.1ns max over a any 180kHz wiithin the passba and Maximum m average inputt power 50 00W Maximum m PEP input pow wer 50 000W | GENER RAL SPEC CIFICATION NS Monitor port p coupling ort -40dB nom. relattive to COM po Isolation 698-960 6 port to o 1710-2170 po ort Intermodu ulation productts 70 0dB typ, 60dB m min 1 <--155dBc all porrts DC/AISG path to COM port p dependentt on port voltag ges LO port wins w HI port wiins (LO Port DC>7V V) and (HI Port DC<6V) and (A AISG Port DC< <2.5V) (H HI Port DC>7V)) and (AISG Po ort DC<2.5V) O OR (B Both LO Port DC C and AISG Po ort DC<2.5V) AISG porrt wins AISG>7V Maximum m DC voltage 31 1V DC DC curren nt rating 2A A continuous, 4 4A peak DC supply current, typic cal AISG: 100mA, L O: 60mA, HI: 1 1mA (one port powered at a ttime) Compatib bility AISG 1.1, 2.0 an nd 3GPP TS25 5.461 DC break kdown 10 000V (COM, 70 00/850/900, AW WS/PCS & AIS SG ports) Voltage drop d in DC path h 2.4 4V max at 2A | ENVIR RONMENTA AL 1 Environm mental rating Ingress protection ET TSI EN 300 01 9 class 4.1 IP P67 Temperatture -40° to +65°C | -40° to 149°F Lightning protection 5k kA (8/20µs) on RF ports, 2kA (8/20µs) on AIISG port Typ value = min value averaged across larrge sample of pro oducts. = min guaranteed value across th he full temperatu ure range. Min value= |2| © 2014 Kaelus. All Rights Resserved. ww ww.kaelus..com D DBC2037F1V1-2 ISSUE A TECHN NICAL SP PECIFICA ATIONS CONTINUE C ED | | MECHA ANICAL Connecto ors Dimensio ons excluding brackets b and connectors, H x D x W Finish RF F: 7-16 DIN (F)) long neck x 6 6, Monitor: N-tyype (F) x 2 AISG: IEC60130 0-9, 8-pin male x 2 18 80 x 91.9 x 150 0mm | 6.7 x 3..6 x 5.9in Pa ainted, light gre ey (RAL7035) Weight 6.4 4kg | 14.0lbs Mounting Wall W or pole mou unt Orientatio on CO OM port upwarrds ORDER RING INF FORMATION | P Number Kaelus Part DBC2037 7F1V1-2 Ka aelus Descrip tion pler, 700/850 a and AWS/PCS,, with integrated d AISG Crross band coup mo odem and mon nitor port, Twin unit ELECT TRICAL BLOCK B DIAGRAM | |3| © 2014 Kaelus. All Rights Resserved. ww ww.kaelus..com D DBC2037F1V1-2 ISSUE A MECHA ANICAL BLOCK B DIAGRAM D M - TWIN UNIT | 700/850 0/900 and AWS/P PCS Cross Band d Coupler with integrated monitorr port and AISG modem including g mounting brackket Inforrmation contained d within this data asheet is valid at the time of relea ase and may be reviewed by Kae elus at any time. |4| © 2014 Kaelus. All Rights Resserved. ww ww.kaelus..com D DBC2037F1V1-2 ISSUE A
© Copyright 2026 Paperzz