NA2XS(F)2Y 6/10 kV, 12/20 kV, 18/30 kV 09

NA2XS(F)2Y 6/10 kV, 12/20 kV, 18/30 kV
Aluminium core, XLPE insulated, longitudinally water-tight, PE sheath
Cable structure
Technical data
- Aluminium core, stranded according to HD 383,
IEC 60228
- Inner semi-conducting coating
- Core insulation of cross-linked polyethylene (XLPE)
- Outer semi-conducting coating spliced with the insulation
- Tape of conductive material
- Tape of longitudinally water-tight material
- Screening of copper wires and one or two copper tapes contrary
applied
- Wrapping with non-conducting tape
- Sheath of PE compound, color black
- XLPE-insulated cable according to DIN VDE 0276 part 620,
HD 620 S1 and IEC 60502
- Operating temperature range
during installation -5 °C to +70 °C, fixed from -30°C to +70°C,
on the core max. +90°C
- Short circuit temperature
250 °C (up to 5 seconds)
- Nominal voltages Uo/U
6/10 kV, 12/20 kV, 18/30 kV
- Operating voltages
6/10 kV = max. 12 kV
12/20 kV = max. 24 kV
18/30 kV = max. 36 kV
- Test voltage a.c.
6/10 kV = 21 kV up to 5 min.
12/20 kV = 42 kV up to 5 min.
18/30 kV = 63 kV up to 5 min.
- Minimum bending radius
approx. 15҂ cable diameter
Application
Cable is suitable for installation in cable ducts, power plants as well as for outer laying into earth, water or for installation in distribution
boards. Due to its good shaping characteristics, this cable can also be laid even in difficult line guideways. To avoid the influence of
the outer interferences, an adherent semi-conductive layer is extruded between the conductor and the insulation. We recommend
the use of stripping tool for correct installation.
Ordering code
Approx.
outer ∅
[mm]
Insulation
thickness
[mm]
PE sheath
thickness
[mm]
1x35 rm/16
1x50 rm/16
1x70 rm/16
1x95 rm/16
1x120 rm/16
1x150 rm/25
1x185 rm/25
1x240 rm/25
1x300 rm/25
1x400 rm/35
1x500 rm/35
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
2,5
26
2,5
2,5
2,5
28
30
31
32
34
36
38
40
44
47
1x50 rm/16
1x70 rm/16
1x95 rm/16
1x120 rm/16
1x150 rm/25
1x185 rm/25
1x240 rm/25
1x300 rm/25
1x400 rm/35
1x500 rm/35
5,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
1x50 rm/16
1x70 rm/16
1x95 rm/16
1x120 rm/16
1x150 rm/25
1x185 rm/25
1x240 rm/25
1x300 rm/25
1x400 rm/35
1x500 rm/35
8,0
Number of cores
҂ core cross section
[mm2]
Cooper
Aluminium Approx.
weight
cable weight weight
[kg/km]
[kg/km]
[kg/km]
Current carrying capacity [A]
in earth (20 °C)
in air (30 °C)
NA2XS(F)2Y 6/10 kV
0932600
0932601
0932602
0932603
0932604
0932605
0932606
0932607
0932608
0932609
0932610
2,5
2,5
2,5
2,5
2,5
2,5
2,5
102
145
203
276
348
435
537
696
870
1160
1450
780
850
980
1080
1150
1280
1420
1630
1950
2350
2780
182
182
182
182
182
283
283
283
283
394
394
171
208
248
283
315
182
182
182
182
283
283
283
283
394
394
172
210
251
285
319
361
417
471
535
609
185
231
280
323
366
182
182
182
182
283
283
174
213
254
289
322
364
187
232
282
325
283
283
394
394
422
476
541
616
357
413
466
529
529
602
183
228
278
321
364
418
494
568
660
660
767
NA2XS(F)2Y 12/20 kV
0932611
0932612
0932613
0932614
0932615
0932616
0932617
0932618
0932619
0932620
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
2,5
2,5
32
145
203
276
348
435
537
696
43
45
48
52
870
1160
1450
920
1030
1140
1250
1320
1570
1780
2100
2480
2900
37
38
40
42
43
45
47
50
53
56
145
203
276
348
435
537
696
870
1160
1450
1250
1500
1700
1800
2050
2150
2400
2700
3200
3550
33
34
37
39
41
420
496
569
660
766
NA2XS(F)2Y 18/30 kV
0932621
0932622
0932623
0932624
0932625
0932626
0932627
0932628
0932629
0932630
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
www.ddacables.com
www.ddacables.com
367
421
496
568
659
764
09-10
09