NA2XS(F)2Y 6/10 kV, 12/20 kV, 18/30 kV Aluminium core, XLPE insulated, longitudinally water-tight, PE sheath Cable structure Technical data - Aluminium core, stranded according to HD 383, IEC 60228 - Inner semi-conducting coating - Core insulation of cross-linked polyethylene (XLPE) - Outer semi-conducting coating spliced with the insulation - Tape of conductive material - Tape of longitudinally water-tight material - Screening of copper wires and one or two copper tapes contrary applied - Wrapping with non-conducting tape - Sheath of PE compound, color black - XLPE-insulated cable according to DIN VDE 0276 part 620, HD 620 S1 and IEC 60502 - Operating temperature range during installation -5 °C to +70 °C, fixed from -30°C to +70°C, on the core max. +90°C - Short circuit temperature 250 °C (up to 5 seconds) - Nominal voltages Uo/U 6/10 kV, 12/20 kV, 18/30 kV - Operating voltages 6/10 kV = max. 12 kV 12/20 kV = max. 24 kV 18/30 kV = max. 36 kV - Test voltage a.c. 6/10 kV = 21 kV up to 5 min. 12/20 kV = 42 kV up to 5 min. 18/30 kV = 63 kV up to 5 min. - Minimum bending radius approx. 15҂ cable diameter Application Cable is suitable for installation in cable ducts, power plants as well as for outer laying into earth, water or for installation in distribution boards. Due to its good shaping characteristics, this cable can also be laid even in difficult line guideways. To avoid the influence of the outer interferences, an adherent semi-conductive layer is extruded between the conductor and the insulation. We recommend the use of stripping tool for correct installation. Ordering code Approx. outer ∅ [mm] Insulation thickness [mm] PE sheath thickness [mm] 1x35 rm/16 1x50 rm/16 1x70 rm/16 1x95 rm/16 1x120 rm/16 1x150 rm/25 1x185 rm/25 1x240 rm/25 1x300 rm/25 1x400 rm/35 1x500 rm/35 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 2,5 26 2,5 2,5 2,5 28 30 31 32 34 36 38 40 44 47 1x50 rm/16 1x70 rm/16 1x95 rm/16 1x120 rm/16 1x150 rm/25 1x185 rm/25 1x240 rm/25 1x300 rm/25 1x400 rm/35 1x500 rm/35 5,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 1x50 rm/16 1x70 rm/16 1x95 rm/16 1x120 rm/16 1x150 rm/25 1x185 rm/25 1x240 rm/25 1x300 rm/25 1x400 rm/35 1x500 rm/35 8,0 Number of cores ҂ core cross section [mm2] Cooper Aluminium Approx. weight cable weight weight [kg/km] [kg/km] [kg/km] Current carrying capacity [A] in earth (20 °C) in air (30 °C) NA2XS(F)2Y 6/10 kV 0932600 0932601 0932602 0932603 0932604 0932605 0932606 0932607 0932608 0932609 0932610 2,5 2,5 2,5 2,5 2,5 2,5 2,5 102 145 203 276 348 435 537 696 870 1160 1450 780 850 980 1080 1150 1280 1420 1630 1950 2350 2780 182 182 182 182 182 283 283 283 283 394 394 171 208 248 283 315 182 182 182 182 283 283 283 283 394 394 172 210 251 285 319 361 417 471 535 609 185 231 280 323 366 182 182 182 182 283 283 174 213 254 289 322 364 187 232 282 325 283 283 394 394 422 476 541 616 357 413 466 529 529 602 183 228 278 321 364 418 494 568 660 660 767 NA2XS(F)2Y 12/20 kV 0932611 0932612 0932613 0932614 0932615 0932616 0932617 0932618 0932619 0932620 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 2,5 2,5 32 145 203 276 348 435 537 696 43 45 48 52 870 1160 1450 920 1030 1140 1250 1320 1570 1780 2100 2480 2900 37 38 40 42 43 45 47 50 53 56 145 203 276 348 435 537 696 870 1160 1450 1250 1500 1700 1800 2050 2150 2400 2700 3200 3550 33 34 37 39 41 420 496 569 660 766 NA2XS(F)2Y 18/30 kV 0932621 0932622 0932623 0932624 0932625 0932626 0932627 0932628 0932629 0932630 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 www.ddacables.com www.ddacables.com 367 421 496 568 659 764 09-10 09
© Copyright 2025 Paperzz