TEMPERATURE INDICATOR DATASHEET F040 - TEMPERATURE INDICATOR WITH VERY LARGE DIGITS Advantages Signal input • Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications. • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all! • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors! Temperature • PT100 - 2, 3 or 4 wire. • (0)4 - 20mA. • 0 - 10V DC. Applications • The F-Series is your first and safest choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmosphers and temperatures between -40°C up to +80°C (-40°F up to 176°F). • Applications where a basic temperature measurement display is required without temperature monitoring. More sophisticated models: F043, F140 and F143 or the D-Series DIN panel mount indicators. Features • • • • • • • • • Displays actual temperature and measuring unit. Very large 26mm (1") digits. Piegraph indication: ten segments. Number of digits for temperature: 5 1/2 . Selectable on-screen engineering units: °C-°F-K. Auto backup of all settings. Explosion/flame proof available. LED backlight option. Loop or battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. • Sensor supply 8.2 / 12 / 24V DC. 1 General information Signal input Introduction The F040 does accept (0)4 - 20mA and 0 - 10V input signals from any type of temperature measurement device. Also a two, three or four wire PT100 sensor can be used. Thermocouple inputs are in preparation. The F040 is a straight forward temperature indicator, displaying the actual value with its measuring unit. The display is typically used as a battery powered indicator for PT100 temperature sensors but also often used with (0)4 - 20mA input signals. The measuring unit to be displayed is simply selected through an alfa-numerical configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user friendly solution! The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive dip-switches or trimmers. A wide selection of options further enhances the capabilities of this model, including Intrinsic Safety for hazardous area applications. Power requirements Several power supply options are available to power the F040 and sensor. A battery powered version with a long life lithium battery which will last up to five years. A 4 - 20mA input loop powered version is available as well. A real sensor supply is offered with the 24V AC/DC or 115 - 230V AC power requirement options. Hazardous area For hazardous area applications, this model has been ATEX, IECEx, FM and CSA certified Intrinsically Safe for gas and dust applications, with an allowed ambient temperature of -40°C to +70°C (-40°F to +158°F). A flame proof Ex d enclosure with ATEX certification is also available. Display The display has very large 26mm (1”) digits which displays the temperature and measuring unit. As the F040 has been designed for field mounted applications, a smart display update function has been incorporated: related to the lower ambient temperature, the update frequency of the LCD is tuned automatically to achieve a readable display even at -40°C / -40°F. Enclosures Various types of enclosures can be selected, all ATEX, IECEx, FM and CSA approved. As standard the F040 is supplied in an GRP panel mount enclosure, which can be converted to an IP67 / NEMA Type4X GRP field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure with IP67 / NEMA Type4X rating. Both European or U.S. cable gland entry threads are available. Backlight For those applications where readability during day and night is an issue, a white backlight is available. The intensity can be adjusted from the keyboard. The display is a transflective type, which means that a high contrast reading is guaranteed in full sunlight as well as during the night. This backlight option is also available Intrinsically Safe. Overview application F040 Configuration All configuration settings are accessed via a simple operator menu which can be password protected. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations. All settings are safely stored in EEPROM memory in the event of sudden power failure. Temperature input 2 F040 Dimensions enclosures Terminal connections analog input Power requirement PB/PC - PD - PL - PX Aluminum & GRP panel mount enclosure 31 mm (1.22") TEMPERATURE INPUT 29 mm (1.14") BACKLIGHT POWER REQUIREMENTS 120 mm (4.72") 130 mm (5.12") 115 (4.53") 02 98 (3.86") 01 04 03 T: PT100 See specific terminal layout. A: (0)4 - 20mA HB & HC enclosures 07 08 09 Aluminum & GRP field / wall mount enclosures + + U+ For analog input (type U): voltage as connected to terminal 5. A - PL: 4 - 20mA 10 ZB: 20 - 30V DC For analog input (type A): voltage as connected to terminal 5. U: 0 - 10V + PL: input loop powered. I+ Ø 7mm (0.27") Ø 7mm (0.27") 06 I+ panel cut-out 130 mm (5.12") 05 PD: 16 - 30V DC 120 mm (4.72") PX: 8 - 30V DC 60 mm (2.36") + 75 mm (2.95") PB / PC: battery powered (PX is also available: if an external supply is connected, the battery supply will be switched off / on automatically.) 112 mm (4.40") Aluminum PG9 GRP 22,50mm 30mm 30mm HD M20 x 1,5 PG9 30mm 30mm HL HE /2"NPT 1 Ø16 22,50mm 30mm 30mm HM 01 Ø16 HF M16 x 1,5 M20 x 1,5 Ø20 02 03 04 05 BACKLIGHT 06 07 08 09 10 ZB: 20 - 30V DC PX: 8 - 30V DC TP: PT100 2 - wire 22,50mm (0.9") / "NPT 1 2 POWER REQUIREMENTS TEMPERATURE INPUT 22,50mm 1.18" 0.9" 1.18" M16 x 1,5 HA Terminal connections PT100 input Power requirement PB/PC - PX + + TP: PT100 3 - wire Ø22 ( 7/8") HG Ø20 M20 x 1,5 24mm 24mm 36mm 36mm M20 x 1,5 M20 x 1,5 14mm 17mm 12mm 12mm 24mm 24mm 36mm 36mm HP Terminal connections analog / PT100 input Power requirement PF Ø12 30mm (1.18") 30mm (1.18") HJ 6 x M12 POWER REQUIREMENTS 0.9" HT 00 HK 0.9" 38mm - 03 04 05 15mm HV TP: PT100 2 - wire TP: PT100 3 - wire 4 x M20 x 1.5 TP: PT100 4 - wire HZ F040 3 06 07 + + + + U: 0 - 10V + PM: 115 - 230V AC /2"NPT 15mm / "NPT PF: 24V DC HU 1 16mm 15mm 02 A: (0)4 - 20mA PF: 24V AC 1.18" 1.18" 1 2 01 Flat bottom, no holes available. / "NPT / "NPT TEMPERATURE INPUT Ø22 ( 7/8") Ø22 ( 7/8") Ø22 ( 7/8") 1 2 1 2 PB / PC: battery powered (PX is also available: if an external supply is connected, the battery supply will be switched off / on automatically.) 17mm HH 14mm HO TP: PT100 4 - wire Ø20 12mm 12mm 25mm 22,50mm 25mm 22,50mm HN 22,50mm (0.9") 22,50mm 25mm 25mm Typical wiring diagram F040-T-PB TERMINAL CONNECTORS F0 - series Typical wiring diagram F040-T-PX-ZB Type PB: BATTERY POWERED Type PB: BATTERY POWERED TERMINAL CONNECTORS F0 - series 10 09 06 09 06 8 - 30V DC 04 03 Temperature sensor type T: PT100 01 01 02 02 03 Temperature sensor type T: PT100 Sensor supply: not available. Sensor supply: not available. Typical wiring diagram F040-A-PX-ZB TERMINAL CONNECTORS F0 - series Power supply type PX: 8 - 30V DC 05 Common ground 04 05 Main supply 20 - 30V DC - Power supply type PX: 8 - 30V DC (not used in this example) Backlight option: type ZB + Backlight supply Common ground - 10 + Backlight option: type ZB 20 - 30V DC (not used in this example) Typical wiring diagram F040-A-PL-ZB Type PL: INPUT LOOP POWERED TERMINAL CONNECTORS F0 - series Type PX: BASIC 8 - 30V DC POWER REQUIREMENT (STANDARD) 05 Common ground 04 Backlight option: type ZB 09 10 09 Main supply Common ground 20 - 30V DC - Common ground Backlight option: type ZB 20 - 30V DC 10 + Backlight supply Backlight supply 02 01 Common ground 01 Circuit depends on type of signal Signal 8 - 30V DC - 02 Temperature input type A - PL: Input loop powered 4 - 20mA + - Circuit depends on type of signal + 8 - 30V DC Temperature input type A: (0)4 - 20mA Signal Common ground Power supply type PX: 8 - 30V DC Sensor supply: sensor is externally powered. * Sensor supply voltage: Terminal 3: not available. 4 F040 Typical wiring diagram F040-A-PD-ZB TERMINAL CONNECTORS F0 - series Typical wiring diagram F040-A-PF-ZB Type PD: 16 - 30V DC POWER REQUIREMENT TERMINAL CONNECTORS F0 - series Type PF: 24V AC / DC POWER REQUIREMENT * Sensor supply voltage: Terminal 7: 8.2 / 12 / 24V DC. Please note: Power supply type PD is not available for temperature sensor type T PT100 Typical wiring diagram F040-A-PM-ZB Type PM: 115 - 230V AC POWER REQUIREMENT 07 Supply * Temperature input type A: (0)4 - 20mA Common ground Power supply type PM: 115 - 230V AC N L1 00 01 Main supply 05 Common ground 06 Signal 02 Circuit depends on type of signal Backlight option: type ZB Internally powered. * Sensor supply voltage: Terminal 7: 8.2 / 12 / 24V DC. F040 07 Common ground * Sensor supply voltage: Terminal 3: not available. Terminal 6 with type PD: voltage as connected to terminal 5 (internally linked). TERMINAL CONNECTORS F0 - series 06 01 02 Common ground 02 Main supply Signal 00 05 04 Temperature input type A: (0)4 - 20mA 01 Circuit depends on type of signal 16 - 30V DC 5 Power supply type PF: 24V AC / DC 24V DC - Common ground - Main supply Common ground Sensor supply type PD: 16 - 30V DC Temperature input type A: (0)4 - 20mA Signal + 06 Supply * Supply * 05 Circuit depends on type of signal 09 Backlight option: type ZB Internally powered. + Backlight supply Common ground 10 Backlight option: type ZB 20 - 30V DC Hazardous area applications The F040-PD-XI offers the input voltage to power an analog sensor. An ATEX approved flame proof Ex d enclosure is available as well. Please contact your supplier for further details. The F040-XI has been certified according ATEX and IECEx by KEMA and according CSA c-us and FM for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). • The ATEX markings for gas and dust applications are: II 1 G Ex ia IIC T4 Ga II 1 D Ex ia IIIC T100 °C Da. • The IECEx markings for gas and dust applications are: Ex ia IIC T4 Ga and Ex ia IIIC T100 °C Da. • The CSA c-us markings are: Class I/II/III, Division 1, Groups A, B, C, D, E, F, G, Temperature class T4 and Class I, Zone 0, AEx ia IIC T4. • The FM markings are: Class I/II/III, Division 1, Groups A, B, C, D, E, F, G, Temperature class T4 and Class I, Zone 0, AEx ia IIC T4. It is allowed to connect up to three I.S. power supplies to power the unit, sensor and backlight. Consult the certificate for the maximum input and output values of the circuits. Certificate of conformity KEMA 05ATEX1168 X • IECEx KEM 08.0006X • CSA.08.2059461 X CERTIFICATE OF CONFORMITY 1. HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT PER US REQUIREMENTS 2. Certificate No: 3. Equipment: (Type Reference and Name) F0 Series General Purpose Indicators 4. Name of Listing Company: Fluidwell BV 5. Address of Listing Company: Voltaweg 23 5466 AZ Veghel Netherlands 6. The examination and test results are recorded in confidential report number: 7. FM Approvals LLC, certifies that the equipment described has been found to comply with the following Approval standards and other documents: FM16US0177X 3033306 dated 25 June 2009 FM Class 3600:2011, FM Class 3610:2015, FM Class 3810:2005, ANSI/UL 60079-0:2013, ANSI/UL 60079-11:2014, ANSI/IEC 60529:2004 8. If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to specific conditions of use specified in the schedule to this certificate. 9. This certificate relates to the design, examination and testing of the products specified herein. The FM Approvals surveillance audit program has further determined that the manufacturing processes and quality control procedures in place are satisfactory to manufacture the product as examined, tested and Approved. 10. Equipment Ratings: Intrinsically Safe for use in Class I / II / III, Division 1, Groups A, B, C, D, E, F and G Class I, Zone 0, Group IIC, Hazardous (Classfied) Locations Certificate issued by: 20 September 2016 J. E. Marquedant Manager, Electrical Systems Date To verify the availability of the Approved product, please refer to www.approvalguide.com THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE FM Approvals LLC. 1151 Boston-Providence Turnpike, Norwood, MA 02062 USA T: +1 (1) 781 762 4300 F: +1 (1) 781 762 9375 E-mail: [email protected] www.fmapprovals.com F 347 (Mar 16) Page 1 of 3 Configuration example IIA - IIB and IIC - F040-T-PC-XI - Battery powered unit HAZARDOUS AREA SAFE AREA Backlight option: type ZB (Not used in this example). Power supply type PX: 8 - 30V DC (Not used in this example). Temperature sensor type T: PT100 01 02 03 04 05 06 09 10 TERMINAL CONNECTORS F0 - series * Sensor supply voltage for analog temperature sensor type A / U: not available in this example. Please note: type PX may be used in combination with the battery (type PC). PX will power the unit; the battery will be disabled automatically till power is disconnected. 6 F040 Configuration example IIA - IIB and IIC - F040-A-PD-XI-ZB - Power requirement 16 - 30V DC HAZARDOUS AREA TERMINAL CONNECTORS F0 - series SAFE AREA + 10 Supply backlight Backlight option: type ZB - 05 + Supply * 06 09 Common ground Main supply Power supply type PD: 16 - 30V DC - Power supply Uo = max. 30V Io = max. 200mA Po = max. 1,2W Power supply For example MTL 5525 For example MTL 5525 I.S. temperature sensor - input type A: (0)4 - 20mA Signal 02 Circuit depends on type of signal 04 Common ground Uo = max. 30V Io = max. 200mA Po = max. 0,75W 01 Common ground Note: above values are safety values. Consult the technical specification for operational values. * Sensor supply voltage for analog temperature sensor type A / U: Terminal 6: as input voltage terminal 5 (internally linked). Please note: type PD may be used in combination with the battery (type PC). PD will power the unit; the battery will be disabled automatically till power is disconnected. Configuration example IIA - IIB and IIC - F040-A-PL-XI-ZB - Input loop powered HAZARDOUS AREA TERMINAL CONNECTORS F0 - series SAFE AREA + 10 Supply backlight Backlight option: type ZB - 09 02 Signal - Circuit depends on type of signal I.S. temperature sensor - input type A - PL: 4 - 20mA input loop powered + Common ground 01 Common ground Uo = max. 30V Io = max. 200mA Po = max. 0,75W Power supply Uo = max. 30V Io = max. 93mA Po = max. 0,92W Power supply For example MTL 5525 For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. Sensor supply is not available: unit is input loop powered (type PL). Please note: type PL may be used in combination with the battery (type PC). PL will power the unit; the battery will be disabled automatically till power is disconnected. F040 7 Directives & Standards Technical specification EMC Low voltage RoHS ATEX / IECEx General Display Type Dimensions Digits Piegraph Refresh rate Option ZB High intensity reflective numeric and alphanumeric LCD, UV-resistant. 90 x 40mm (3.5" x 1.6"). 51/2 very large 26mm (1") digits. Various symbols and measuring units. Ten segments - related to the input signal. User definable: fast, 1sec , 3sec, 15sec, 30sec, off. Transflective LCD with white LED-backlight. Intensitiy can be adjusted in the configuration menu. Good readings in full sunlight and darkness. Also available Intrinsically Safe. FM CSA IP & NEMA Directive 2014/30/EU, FCC 47 CFR part 15. Directive 2014/35/EU. Directive 2011/65/EU. Directive 2014/34/EU, IEC 60079-0, IEC 60079-11, IEC 60079-26. FM Class No. 3600, FM Class No. 3610. CSA 22.2 No. 157-92. EN 60529 & NEMA 250. Enclosure General Window Sealing Control keys Ambient temperature Safe areas -40°C to +80°C (-40°F to +176°F). Intrinsically Safe -40°C to +70°C (-40°F to +158°F). Polycarbonate window. Silicone. Three industrial micro-switch keys. UV-resistant silicone keypad. Aluminum wall / field mount enclosures General Power requirements Type PB Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years. (requires PD, PL or PX) Type PC Intrinsically Safe long life lithium battery - life-time depends upon settings and configuration - up to 5 years. (requires XI, and PD, PL or PX) Type PD 16 - 30V DC. Power consumption max. 1 Watt. Type PF 24V AC / DC ± 10%. Power consumption max. 15 Watt. Type PL Input loop powered from sensor signal 4 - 20mA (type A). Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt. Type PX 8 - 30V DC. Power consumption max. 0.3 Watt. Type ZB 20 - 30V DC. Power consumption max. 1 Watt. With type PF / PM: internally powered. Note PB/PF/PM Not available Intrinsically Safe. Note PF/PM The total consumption of the sensor and backlight type ZB may not exceed 400mA @ 24V DC. Note For Intrinsically Safe applications, consult the safety values in the certificate. Dimensions Weight Type HA Type HL Type HM Type HN Type HO Type HP Type HT Type HU Type HV Type HZ GRP wall / field mount enclosures General Dimensions Weight Type HD Type HE Type HF G Type H Type HH Type HJ Type HK Sensor excitation Type PB/PC/PX Type PD Type PF / PM Note Not available, just suitable for PT100 sensors. The sensor supply voltage will be according to power supply voltage (as connected to terminal 5). 8.2 / 12 and 24V DC - max. 400mA @ 24V DC. There is no sensor supply available for PT100 sensors. Terminal connections Type Dimensions Panel cut-out Type HB Password GRP wall/field mount enclosure IP67 / NEMA Type4X, UV-resistant and flame retardant. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 600 gr. Cable entry: no holes. Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8"). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8"). Flat bottom, cable entry: no holes. Panel mount enclosures Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2. Data protection Type Die-cast aluminum wall/field mount enclosure IP67 / NEMA Type4X with 2-component UV-resistant coating. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 1100 gr. Cable entry: 2 x PG9 and 1 x M20. Cable entry: 2 x 1/2" NPT. Cable entry: 2 x M16 and 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2" NPT. Cable entry: 3 x 1/2" NPT. Cable entry: 4 x M20. Cable entry: no holes. EEPROM backup of all settings. Data retention at least 10 years. Configuration settings can be password protected. Weight Type HC Weight 8 130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D. 115 x 98mm (4.53" x 3.86") L x H. Die-cast aluminum panel mount enclosure IP65 / NEMA Type4X. 600 gr. GRP panel mount enclosure IP65 / NEMA Type4X, UV-resistant and flame retardant. 450 gr. F040 Hazardous area Intrinsically Safe ATEX certification IECEx certification CSA c-us certification FM certification Ambient Ta Accessories Mounting accessories II 1 G Ex ia IIC T4 Ga. II 1 D Ex ia IIIC T100 °C Da. Ex ia IIC T4 Ga. Ex ia IIIC T100 °C Da. Intrinsically Safe for Class I/II/III, Div. 1, Groups A, B, C, D, E, F, G, Temp. class T4 and Class I, Zone 0, AEx ia IIC T4. Intrinsically Safe for Class I/II/III, Div. 1, Groups A, B, C, D, E, F, G, Temp. class T4 and Class I, Zone 0, AEx ia IIC T4. -40°C to +70°C (-40°F to +158°F). ACF02 ACF05 ACF06 ACF07 ACF08 ACF09 ACF11 Cable glands ACF20 ACF25 ACF26 ACF27 ACF28 ACF29 ACF32 ACF33 ACF34 ACF35 ACF39 ACF40 Explosion proof ATEX certification Type XF Weight Note Stainless steel wall mounting kit. Stainless steel pipe mounting kit (worm gear clamps not included). Two stainless steel worm gear clamps Ø 44 - 56mm. Two stainless steel worm gear clamps Ø 58 - 75mm. Two stainless steel worm gear clamps Ø 77 - 95mm. Two stainless steel worm gear clamps Ø 106 - 138mm. Swivel with 25° movement from center axis for direct flowmeter mounting: 1” NPT to 1/2” NPT. II 2 G / Ex d IIB T5 Gb. II 2 D / Ex t IIIB T100 °C Db. Dimensions of enclosure: 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Appr. 15kg. IECEx available on request. Signal inputs Temperature Resolution: 16 bit. Error < 0.01mA / ± 0.05% FS. Low level cut-off programmable. Type A (0)4 - 20mA. Analog input signal can be scaled to any desired range within 0 - 20mA. Span 0.00001 - 199,999 with variable decimal position. Offset -99,999 / +199,999 units. Voltage drop Type A: max. 1V DC @ 20mA. Voltage drop Type A - PL (loop powered): max. 2.6V DC @ 20mA. Update time Four times per second. Type T 2, 3 or 4 wire PT100 (requires PB, PC or PX). Offset -999.9 / +999.9 units. Update time Once per second. Range -100°C to +200°C (-148°F to 392°F). Accuracy 0.1°C (0.2°F). Type U 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. Span 0.00001 - 199,999 with variable decimal position. Offset -99,999 / +199,999 units. Load impedance 3kOhm. Update time Four times per second. Note For signal A and U: power supply to temperature sensor is required; e.g. PD. Accuracy For HA enclosure, includes O-rings. For HE enclosure, includes locknuts and O-rings. For HF enclosure, includes locknuts and O-rings. For HG enclosure, includes locknuts and O-rings. For HH enclosure, includes locknuts and O-rings. For HJ enclosure, includes locknuts and O-rings. For HM enclosure, includes O-rings. For HN enclosure, includes O-rings. For HO enclosure, includes O-rings. For HP enclosure, includes O-rings. For HT enclosure, includes O-rings. For HU enclosure, includes O-rings. Intrinsically Safe isolators ACG01 ACG02 ACG03 ACG04 ACG05 ACG06 ACG07 MTL5511 - One channel pulse or switch output transfer from hazardous area to safe area. MTL5525 - One channel power supply from safe area to hazardous area (e.g. to power the unit with PD or to power a switching or analog device in hazardous area). MTL5541 - One channel 4 - 20mA repeater from hazardous area to safe area. MTL 5051 - Bi-direction serial-data-isolator (for Modbus communication). MTL5516C - Two channel pulse or switch output transfer from hazardous area to safe area. MTL5513 - One channel pulse or switch output transfer from hazardous area to safe area. MTL5546Y - One channel isolated driver bringing 4 - 20mA from safe area to hazardous area, HART transparent, OCD. Display example - 90 x 40mm (3.5" x 1.6") Operational Operator functions Displayed functions • Actual temperature. • Measuring unit. Temperature Digits Units Decimals F040 51/2 digits. °C, °F or K. Type T: 1. Type A / U: 0 - 1 - 2 - 3 - 4 or 5. 9 Ordering information Standard configuration: F040-A-HC-PX-XX-ZX. ordering information: Temperature input signal A T U F040 -_ -H _ -P _ -X _ -Z _ (0)4 - 20mA input. PT100 input - requires PX. 0 - 10V DC input. Panel mount enclosures - IP65 / NEMA Type4X HB HC Aluminum enclosure. GRP enclosure. GRP field / wall mount enclosures - IP67 / NEMA Type4X HD HE HF G H HH HJ HK Cable entry: no holes. Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8”). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8”). Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures - IP67 / NEMA Type4X HA HL HM HN HO HP HT HU HV HZ Cable entry: 2 x PG9 + 1 x M20. Cable entry: 2 x 1/2”NPT. Cable entry: 2 x M16 + 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2”NPT. Cable entry: 3 x 1/2”NPT. Cable entry: 4 x M20. Cable entry: no holes. Power requirements PD PF PL PM PX 16 - 30V DC + sensor supply. 24V AC / DC + sensor supply. Input loop powered from sensor signal 4 - 20mA (type A). 115 - 230V AC + sensor supply. Basic power supply 8 - 30V DC (no sensor supply for type A/U sensors). PB PC Lithium battery powered - requires PD, PL or PX. Lithium battery powered - Intrinsically Safe - requires XI, and PD, PL or PX. Additional battery supply (optional) Hazardous area XI XF XX Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM. Ex d enclosure - 3 keys according ATEX. Safe area only. Other options ZB ZX Backlight. No options. The bold marked text contains the standard configuration. Specifications are subject to change without notice. Fluidwell bv P.O. Box 6 5460 AA - Veghel - The Netherlands Telephone: +31 (0)413 343 786 Telefax: +31 (0)413 363 443 email: [email protected] Internet: www.fluidwell.com 10 Copyright: Fluidwell bv - 2017 - F040-DATA-EN-V1704 Available Intrinsically Safe.
© Copyright 2025 Paperzz