Florida Cause of Leak Study Background Info – Florida’s Tanks Program 2005 Single-wall USTs 60% ASTs with Secondary Containment 80% 18,040 16,286 ASTs USTs 3,954 11,937 Source - STCM, Feb 05 Double-wall USTs - 40% Single-wall ASTs - 20% Total Facility Inspections Performed in Florida Source: STCM, Feb 05 35000 30000 25000 20000 Inspections 15000 10000 5000 0 '84 '86 '88 '90 '92 '94 '96 '98 '00 '02 '04 436,121 Total Inspections Performed Petroleum Discharge Report Forms Received Discharges Source: STCM, Feb 05 7000 6303 6000 5000 4000 3467 3385 3000 2341 2330 2000 1834 1775 1374 1000 0 1010 326 141 4 18 19 53 1298 1206 1271 987 881 597504537615564 '80 '82 '84 '86 '88 '90 '92 '94 '96 '98 '00 '02 '04 32,769 Total Discharge Report Forms Received 23 Post-1998 Petroleum Discharge Report Forms Received Source: STCM, Feb 05 Discharges 1400 1271 1200 1000 881 800 597 600 504 537 615 564 400 200 23 0 '98 '99 '00 '01 '02 '03 '04 4992 Post-1998 Discharge Report Forms Received '05 Summary - Florida Cause of Leak Study ¾ ¾ ¾ ¾ ¾ Florida Identified Reported Releases (1995-2002) Florida Contracted with County Inspectors to Review Release Sites and Document Information Completed Forms Sent to EPA for Data Entry & Analysis Various Quality Control Steps Current Status - EPA Report is ready for Peer Review Methodology Invalid Files Include: •Releases from Bare Steel UST Systems •Release From Non-Compliant Component •Release of Old UST/AST Found at Closure •Unknown Sources Size of Study 2280 Release Files Reviewed 642 Valid Release Files 512 UST Releases 130 AST Releases AST Results Sources of Releases Other 16% Dispenser 12% Tank 5% Delivery 32% Piping 35% Other Sources Include: Fuel Filters, Outlet Valve, and Human Spilling Causes of Releases Other 16% Phys/Mech Damage 19% Loose Unknown Component 8% 12% Corrosion 9% Spill/Overfill 36% Other Causes Include: Vandalism, Valve Failure, Contractor Accident, Other Human Error Causes of Piping Release Phys/Mech Damage 29% Corrosion 26% Puncture 2% Other 9% Unknown 13% Loose Component 21% Method of Detection Closure/ Removal 8% Other 2% Leak Detection 22% Visual/ Olfactory 68% Success of Leak Detection LD Detected 22% LD Failed 8% LD Unable, or Unknow n 70% LD Unable, or Unknown: Either the release came from a part of the system that a LD system was not designed to detect, or the inspector could not determine whether LD failed to detect. Overfills and Piping UST Results Sources of Releases - USTs Turbine P ump 10% Other 11% Dispenser 25% Tank 12% Spill/Overfill in Fill A rea 19% P iping 23% - Tank Usage Versus Releases 70% 60% 50% 40% 30% 20% 10% 0% % releases er th O lad C as rg l Fi be St ee s l % usage Clad Tanks Had Relatively Fewer Releases - Causes of Tank Releases Other 13% Unknown 14% Phys/Mech Damage 22% Loose Component 8%Corrosion 16% Puncture 27% Primary Cause of Steel Tank Release – Corrosion Primary Cause of Fiberglass Tank Release - Puncture - Piping Usage Versus Releases 80 60 % release 40 %usage 20 0 Steel Fiberglass Flexible Plastic Further Analysis Required to Determine Statistical Significance - Causes of Piping Releases Corrosion Puncture 7% 15% Other 16% Unknown 20% Phys/Mech Damage 22% Loose Component 20% •Primary Cause of Steel Piping Release – Corrosion •Primary Cause of Fiberglass Piping Release – Loose Component •Primary Cause of Flexible Plastic Piping – Phys/Mech Damage Summary of Causes - USTs Other 16% Unknown 17% Phys/Mech Damage 13% Overfill 12% Loose Component 18% Corrosion 4% Puncture 8% Spill 12% Other Releases Include: Delivery to Monitoring Well, Vehicle Accident, Improper Installation, Vandalism - Success of Leak Detection LD Detected 25% LD Unable, or Unknown 50% LD Failed 25% LD Unable, or Unknown: Either the release came from a part of the system that a LD system was not designed to detect, or the inspector could not determine whether LD failed to detect. - Method of Detection % of Detections 40 30 20 10 Visual/ Olfactory Leak Detection Closure/ Removal Compliance Inspector Other 0 Other Methods Include: Unscheduled TTT/LTT, Dispenser Upgrades, Maintenance Inspections, Water in Tank Piping, Dispensers & Spill Buckets Florida Leak Autopsy Study •Field-verified, Quality assurance •County Tanks Inspectors Complete Forms •Continuation of Florida Cause of Leak Study •Data compared to Forms submitted by tank owners Material Other Attributes Ancillary Equipment Galvanized Steel Sacrificial Anodes Spill Containment Bucket Fiberglass Impressed Current System No Spill Containment Composite Internal Lining Overfill Protection Unprotected Steel Single Wall Ball Check Valve Other Approved Double Wall (same material) Flow Shut-Off Concrete Double Wall (different material) Tight Fill Polyethylene Secondary Containment with a liner Alarm System Unknown Other Approved (Tank Bladders, etc.) Remote Fill Other (Specify) Compartmented No Overfill Protection External Liner Other (Specify) Florida Leak Autopsy Study Four Page Form Florida Leak Autopsy Forms 1 Jan 03 – 1 Mar 05 Valid AST Discharges 30% Invalid AST Forms 2% •859 Forms Forms under investigation 1% Valid UST Discharges 34% Invalid UST Forms 33% UST Sources Dispenser & Piping Sumps 1% Dispensers 16% Line Leak Detectors 2% Overfills Submersible Turbine 5% Pumps 4% Piping 18% Spill Buckets 31% 305 Valid Forms Fill Pipes 3% Tanks 10% Flex connectors & Swing joints 4% Vehicles, Vapor recovery, vent lines, vandalism and shear valves 6% Tanks – 10% Double-wall tanks – 2% Single-Wall Fiberglass Tanks 14 2 Single-Wall Internally Lined Tanks 5 1 Single-Wall Composite Tanks 5 1 2 Unknown Double-Wall Fiberglass Tanks Double-Wall Composite Tanks Single-Wall Protected Steel Tanks Piping – 18% Double-wall piping –9% Double-Wall Fiberglass Piping 4 15 Single-Wall 10 Protected Steel Piping 24 Double-Wall Thermoplastic Flexible Piping Single-Wall Fiberglass Piping 3 Other Single-Wall Pipe – (Copper) Sources - >2003 Piping 22% Overfills/Spills/ Spill Buckets 39% Dispensers 18% Submersible Turbine Pumps 4% Other 13% Tanks 10% Sources - <2003 Dispensers 25% Piping 23% Submersible Turbine Pumps 10% Other 11% Tanks 12% Overfills/Spills/ Spill Buckets 19% Combined Data Piping 23% Dispensers 21 % Submersible Turbine Pumps 8% Other 10% Tanks 11% 827 Valid UST Forms Overfills/Spills/ Spill Buckets 26% Mark Barolo EPA, Office of Underground Storage Tanks 703/603-7141 [email protected] www.epa.gov/oust./ Marshall T. Mott-Smith Bureau of Petroleum Storage Systems (Phone) 850/245-8842 [email protected] http://www.dep.state.fl.us/waste/categories/tanks/default.htm Florida Department of Environmental Protection
© Copyright 2026 Paperzz