QUICKSTART “BASIC” GUIDELINES FOR MODEL 6300 - FOR GATES UP TO 18 FEET AND OPENING 90° Model 6300 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. 120 S. Glasgow Avenue Inglewood, California 90301 U.S.A. Gate Bracket era str nce . at ian is an te s m fo y ti the me us r ve ga t u hic te se les or se pla pa only y rate . en tra nc e. r Pe nin r sig mane g S ns ntl ig of on y m ns th B o ma e gat OTH unt ke e a side r s eas ure t ea an s ily hey d vis ar ible e . e at G Open Gate se Ba Note: 2” thick gate Illustrated. Br t ke ac B st Po 43” e as e at G op Lo Elbow Flange ” Operator Output Shaft 0 #2 to 11 om to # 7 C 1. elay to # R lt 2. 4 Vo 2 3. Concrete 14” 1.5” Output Shaft 12” 12” 3” Output Shaft Position 23” Right Support Leg Left Support Leg Open Gate Open Gate 10” tom ot B le xib Flenduit Co f te o Pla 0 630 h Higlt o V w Lo lt Vo c Jun 3/8 Secure operator to the concrete pad with six (6) 3/8” x 3” sleeve anchors (not supplied). ACwer Ponduit Co it pC u ond Loo wit ” 3/4 eeps w hS Gate Bracket we rm Important: The elbow assembly must be in the correct position on the arms BEFORE cycling operator the first time. High Voltage Conduit Note: “Optional” High Voltage Kit black and white wires connect the same as shown. See High Voltage Kit instruction sheet for more information. Arms and Operator MUST be level. 5” Ground Copyright 2016 DoorKing, Inc. All rights reserved. Loop Detectors C Not included - Refer to the Installation/Owner’s manual and Loop Information Manual (available FREE from www.dkaccess.com) for more information on loops and loop detectors. Gate Bracket Height Radio Receiver D Not included - Refer to a specific Radio Receiver Bottom Plate of 6300 30” Crank Arm Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation. (See reverse side for wiring) Flange 60” Connecting Arm Varies with base used. 1 rA Manual Release s the of is h pt e De ncret by co ined s rm ition e det cond ocal l l soi and des. o c ing d l i bu Po 2 oxe B tion Pad MUST be Level. 30” m 12” Conduit 22” Post Base nk A Concrete Pad A Ar Post Base MUST be Level. Cra 1 Pad Base 3” Conduit 2” 43” Chassis Ground k Post Base 16.5” • NO AC power. • NO DC power (On select models). HIGH VOLTAGE! an 23” Note: 2” thick 43” gate Illustrated. 2 7 C D 90° 5” Run conduit on the opposite side of the open gate for the post base. 3 11 115 VAC Cr Closed Gate 90° B DANGER Adjust 1 to 23 sec. 1. OFF (Opening Counter-Clockwise) 2. OFF 3. OFF 4. OFF 5. OFF (Normal Reverse Function) 6. OFF REQUIRED 7. CLOSE Photo Beam 8. OPEN/CLOSE Edge/Beam See other side 20 Concrete Position Closed Gate ON 24 3. OFF 4. ON 5. ON 6. OFF 7. ON (Single Operator) 8. ON (Tamper Protect) SW 3 1 2 3 4 5 6 7 8 Safety Cover Elbow Assembly B ON w 3” Important: Elbow flange MUST be on the opposite side of the closed gate. Manually adjust the arms to get the correct open and closed positions BEFORE powering up the operator. Open/Close limits will be automatically set the first time operator is cycled. Mount the post base into the concrete before installing the operator. Using shadow loop and gate opening in direction shown. SW 4 Auto Close 1. OFF Timer 2. OFF do .5” DIP-Switch Settings 1 2 3 4 5 6 7 8 t ke ac Br 37 a Sh Important: A straight line drawn from the closed gate bracket through the open gate bracket MUST intersect the operator output shaft. Tip: It is recommended that a surge suppressor be installed on the high voltage power lines. D Wa d Pa 90° GATE OPERATOR MUST BE PROPERLY GROUNDED!! 115 VAC Closed Gate op Lo 12” 34” High Voltage Connection Mo v Se ing rio Ga us te KE E Inj Ca wit P C h L n Do out EAR ury p or Cau in not lerior w! Ga th te De se Th e ga t chil arnin ma is ath d Pe entrte are ren g. y mo de a ve a op Neutral Operator Position se er ev R For safety and installation instructions, please refer to the Installation/Owner’s manual. Brass Bushing Elbow Assembly Crank Power Arm Important: Adjust the locknut on the crank power arm so that it is snug against the washer, but will still allow the 30” crank arm to rotate with little force. 6300-066-N-10-16 QUICKSTART “BASIC” GUIDELINES FOR MODEL 6300 - DIP-SWITCH AND WIRING REFERENCE (2) Two 115 VAC Convenience Outlets Antenna mounted outside operator cover. Model 6300 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. Coax Antenna Kit P/N 1514-073 120 S. Glasgow Avenue Inglewood, California 90301 For safety and installation instructions, please refer to the Installation/Owner’s manual. U.S.A. #11 - Access Control Devices 3 Exit Loop Port Output Full Open Input 6 Auto-Close Timer Slide Operator Swing Operator 3-Button Single Button 7 Dual Operators Single Operator 4 5 8 Tamper Protect OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Description Relay activates when gate is open (Shadow loop setting when used). Relay activates when gate is not closed. Relay activates when gate is opening and open. Relay activates when gate is opening and closing. The output wired to terminal #12 becomes the output from the exit loop detector plugged into the EXIT Loop port. Normal Setting. Terminal #12 is a normal full open input. Auto-close timer is OFF. Manual input required to close gate. Auto-close timer is ON. Adjustable from 1-23 seconds to close gate. Switch must be OFF for slide gate operator (DO NOT use for 6300). Normal Setting. Switch must be ON for swing gate operator. OFF when using a 3-button station (DoorKing 3-button control stations only). ON when using a single button control, terminals 13 &14 become a STOP input. Switch must be OFF when bi-parting (dual) gates are used. Switch must be ON for single operator. Tamper protect is OFF. Normal Setting. Tamper protect is ON. Operator will close gate when being forced open. DoorKing ONLY Key Switch Stand-Alone Keypad 3 Self-Test OFF Same as above, for secondary 6300 ONLY. OFF ON Normal Setting. Normal operation. Self-test mode. Operator MUST be disconnected from gate to run self test. 4 Single Gates OR Bi-Parting Gates OFF Switch is OFF when using a single operator. ON Switch is ON when using dual gate operators (Primary/Secondary Bi-Parting gates). 5 Reverse Shadow Loop 6 Gate Overlap OFF ON OFF ON Terminal 15 is a STANDARD Reverse input. Terminal 15 is a Shadow input. Gate will NOT stop during the close cycle. Primary and secondary operators start at the same time. Secondary operator starts 1-2 seconds prior to primary operator. No Photo Sensor connected to Aux terminal 7 and 8. Photo sensor is connected to Aux terminal 7 and 8 and monitored. (Close ONLY) No Edge or Beam connected to Aux terminal 9 and 10. Edge OR Beam is connected to Aux terminal 9 and 10 and monitored. (Open/Close) 7 8 Monitored Close Beam Monitored Edge/Beam OFF ON OFF ON SW 4 #12 - Safety Opening Device Com 24 Volt 1 amp max. 10 Access 11 Device Open 12 Safety Open 13 14 15 16 17 18 19 Com 13 Potential Entrapment Area 12 14 15 NO NC Aux Terminal POWER PO 7 8 9 10 SW 3 switch 7 MUST be ON. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices. IMPORTANT: Photo sensors must use Normally Closed (NC) contacts with the beam set for light operate (relay activated when beam is not obstructed). DATA 11 CLOSE Photo Sensor 7&8 CLOSED gate All potential entrapment areas MUST be protected with an external entrapment protection device. At least ONE external entrapment protection device MUST be installed or the operator will NOT function. 4502-010 KEY SWITCH Normally Closed (N.C.) CLOSE Beam SW 4, switch 3 must be ON. 9 10 20 Com Com EXIT LOOP 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 Secondary 6300 Gate Opening Direction Note: All stand-alone and telephone entry devices must use a separate power source. Opens Counter-Clockwise ON Power (24 Volt DC) and logic output. Power is shut off .5 sec. prior to gate starting and remains off while gate is opening and in the open position. 2 24 VAC Power ON Opens Clockwise Magnetic Lock 1 1 2 3 4 5 6 7 8 Primary 6300 Gate Opening Direction Description 6 7 8 9 Important: Controls must be installed a minimum of 6-feet from the gate or installed in such a way that the person using the control cannot come in contact with the gate or gate operator. Stand-Alone Card Reader ON SW 3 Setting 24 Volt White Com 1 2 3 4 5 6 7 8 1 Function 2 3 4 5 ON Switch 1 Red Open Green Close Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect. SW 3 (Bottom 8 Switches) Relay 3-Button Station Telephone Entry Monitored CLOSE Beam Common Monitored OPEN/CLOSE Edge/Beam Common Circuit Board Relay Setting 1-OFF 2-OFF 1-OFF 2-ON 1-ON 2-OFF 1-ON 2-ON Main Terminal 1 and 2 ON 1 2 3 4 5 6 7 8 Function SW 4 (Top 8 Switches) Please refer to the Installation/Owner’s manual for complete installation instructions for entrapment protection devices. OPEN gate SW 4 Switch Convenience Open Radio Receiver Note: Wiring may differ. See section 7 in the Installation/Owner’s manual for more info. Com Every time the operator is powered up, the First open command will automatically set the open and close limits of the gate. 3-Wire Radio Receiver Limited to 250 ma. Open/Close Edge Open Photo Sensor 9&10...OR.... OPEN Beam SW 3 switch 8 MUST be ON. Normally Closed (N.C.) Mointored Sensor Note: Only 1 monitored Device can be connected to each input. .......Reverse Edge 9&10 SW 3 switch 8 MUST be ON. SAFETY LOOP
© Copyright 2026 Paperzz