MX200/150/250 Controllers Overview MX200/150/250 GEZC Service School Slide 1 of 26 Contents 1. Introduction 2. MX250 Factory Options 3. Phase Rotation Mismatch 4. In-Phase Monitor (R50) Operation 5. Timers Sequence 6. MX250 Inputs 7. MX250 Outputs 8. Factory Configuration 9. CODEC Software for FAS 10. Frequently Asked Questions (FAQ) MX200/150/250 GEZC Service School Slide 2 of 26 1. Introduction 485 Communication link Viewpoint ATS IBM Compatible • Have I/Os option • Lonwork/Modbus • Commercial /Critical Applications • Std/Delay/Closed Transition ATS MX200/150/250 GEZC ATS Controller Slide 3 of 26 2. MX250 Factory Options 1. Phase Rotation Mismatch / Phase Sequence Mismatch 2. In-Phase Monitor (R50) 3. Voltage Imbalance 4. Universal Motor Disconnect (UMD) 5. Elevator Pre-Signals (W3/T3) 6. Over Voltage, Over Frequency, Under Frequency 7. CTAP 8. Network – LonWork or Modbus MX200/150/250 GEZC ATS Controller Slide 4 of 26 3. Phase Rotation Mismatch C • Only applies to 3-Phase system • Phase Rotation MisMatch – • Only applies to both S1 and S2 having 3 phases A B • Clockwise Rotation (CW) – • A->B->C, B->C->A, C->A->B • Counter Clockwise Rotation (CCW) – • B->A->C, A->C->B, C->B->A CW C B A MX200/150/250 GEZC Service School 0° Slide 5 of 26 CCW 0° 4. In-Phase Monitor (R50) Operation R50 Calculation for 60Hz condition: In terms of time interval – 360° = 16.67ms 1° = (16.67 ÷ 360) ms 1° = 0.0463 ms (or 46.3μs) ∴ 7° = (46.3 × 7)μs = 324.1μs Suppose Δt = 250μs, Then, Degree = 250/46.3 = 5.4 R50 Calculation for 50Hz condition: In terms of time interval – 360° = 20ms 1° = (20 ÷ 360) ms 1° = 0.0555 ms (or 55.5μs) ∴ 7° = (55.5 × 7)μs = 388.5μs Suppose Δt = 250μs, Then, Degree = 250/55.5 = 4.5 MX200/150/250 GEZC Service School Slide 6 of 26 5. MX200/150/250 Timers Sequence GEZC ATS Controller P: Time Delay to S2 Start W: Time Delay to S2 Stable T: Time Delay retransfer to S1 U: Time Delay to S2 Stop W3: Elevator Pre-Signal @ S1 T3: Elevator Pre-Signal @ S2 UMD: Universal Motor Disconnect timer Slide 7 of 26 5. MX200/150/250 Timers Sequence GEZC ATS Controller P: Time Delay to S2 Start W: Time Delay to S2 Stable T: Time Delay retransfer to S1 U: Time Delay to S2 Stop W3: Elevator Pre-Signal @ S1 T3: Elevator Pre-Signal @ S2 UMD: Universal Motor Disconnect timer Slide 8 of 26 5. Timers Sequence Parallel Timers Operation W3/T3 1. W3/T3 = UMD UMD W3/T3 2. W3/T3 > UMD UMD R50 W3/T3 3. W3/T3 < UMD UMD MX200/150/250 GEZC ATS Controller Slide 9 of 26 Xfer 5. Timers Sequence P: Time Delay to S2 Start W: Time Delay to S2 Stable T: Time Delay retransfer to S1 U: Time Delay to S2 Stop DW: Time Delay from OPEN to S2 DT: Time Delay from OPEN to S1 W3: Elevator Pre-Signal @ S1 T3: Elevator Pre-Signal @ S2 UMD: Universal Motor Disconnect timer Attention: Delay transition ATS does not require R50 MX200/150/250 GEZC ATS Controller Slide 10 of 26 5. Timers Sequence P: Time Delay to S2 Start W: Time Delay to S2 Stable T: Time Delay retransfer to S1 U: Time Delay to S2 Stop DW: Time Delay from OPEN to S2 DT: Time Delay from OPEN to S1 W3: Elevator Pre-Signal @ S1 T3: Elevator Pre-Signal @ S2 UMD: Universal Motor Disconnect timer Attention: Delay transition ATS does not require R50 MX200/150/250 GEZC ATS Controller Slide 11 of 26 5. MX200/150/250 Timers Sequence GEZC ATS Controller P: Time Delay to S2 Start W: Time Delay to S2 Stable T: Time Delay retransfer to S1 U: Time Delay to S2 Stop DW: Time Delay from OPEN to S2 DT: Time Delay from OPEN to S1 W3: Elevator Pre-Signal @ S1 T3: Elevator Pre-Signal @ S2 UMD: Universal Motor Disconnect timer Slide 12 of 26 5. MX200/150/250 Timers Sequence GEZC ATS Controller P: Time Delay to S2 Start W: Time Delay to S2 Stable T: Time Delay retransfer to S1 U: Time Delay to S2 Stop DW: Time Delay from OPEN to S2 DT: Time Delay from OPEN to S1 W3: Elevator Pre-Signal @ S1 T3: Elevator Pre-Signal @ S2 UMD: Universal Motor Disconnect timer Slide 13 of 26 6. MX250 Inputs Hardware inputs: 1. Q2/TSL (Test-Switch-Load) 2. TSNL (Test-Switch-No-Load) 3. Q3 (Inhibit Transfer to S2 source) 4. Q7 (Inhibit Re-transfer to S1 source) 5. S5 (Auto or Manual Retransfer to S1 source) 6. S12 (Auto or Manual Retransfer to S1 and S2 sources) 7. LS (Load shed) 8. TMS (Closed Transition mode) 9. YN (Bypass T-timer) 10. YE (Bypass W-timer) 11. ATR (Automatic Transfer Relay) MX200/150/250 GEZC ATS Controller Slide 14 of 26 7. MX250 Outputs Hardware Outputs: 1. LN (Open) 2. L1 (EP) 3. L3 (NA) 4. NIA (Not In Auto) 5. CTAP (Alarm) 6. UMD A62 (Universal Motor Disconnect) 7. L4 (EA) 8. L2 (NP) 9. LS (Load Shed) 10. T3/W3 (Elevator Pre-Signal) 11. STE (Shunt Trip Emergency) MX200/150/250 GEZC ATS Controller Slide 15 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) Click “Manual Configuration” to proceed MX200/150/250 GEZC Service School Slide 16 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) Belden Twisted Pair cable: WMW-453 Programming plug: 50W-1211 RS232-to-485 Converter: 50W-1208 Supporting accessory: One Port USB-232 converter (with GEZC’s part number: 50W-1223 or NI part number: 778472-01) shall be used. 1. Connect TD(A) of 50W-1208 to Pin 2 (socket J4) of MX150/250 Controller via PS5133. 2. Connect TD(B) of 50W-1208 to Pin 1 (socket J4) of MX150/250 Controller via PS5133. MX200/150/250 For information about the USB converter, visit -http://sine.ni.com/nips/cds/view/p/lang/en/nid/12844 GEZC Service School Slide 17 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) MX200/150/250 GEZC Service School Slide 18 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) MX200/150/250 GEZC Service School Slide 19 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) MX200/150/250 GEZC Service School Slide 20 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) MX200/150/250 GEZC Service School Slide 21 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) MX200/150/250 GEZC Service School Slide 22 of 26 8. Factory Configuration MX150/250 Factory Configuration Software (50P-1163) MX200/150/250 GEZC Service School Slide 23 of 26 9. CODEC Software MX150/250 CODEC Software (50P-1167) MX200/150/250 GEZC Service School Slide 24 of 26 9. CODEC Software MX150/250 CODEC Software (50P-1167) MX200/150/250 GEZC Service School Slide 25 of 26 10. Q&A • Exerciser • Timer Configuration • Threshold Fail and Restore levels • Phase Rotation • New DST • FAS MX200/150/250 GEZC Service School Slide 26 of 26
© Copyright 2026 Paperzz