TECHNICAL SPECIFICATION TEMPERATURE PROBE AT-487 (PT100) ENSURING SYSTEM PERFORMANCE The AT-487 temperature sensor is installed on the chamber wall and does not penetrate into the fluid. The probe is designed to prevent high surface temperatures on the UV chamber. Technical Specification Model number Manufacturer Mounting Element material Housing material IP rating Connection cable Type Accuracy Resistance Pressure rating Connection Operating temperature range Storage temperature range * AT-487 ETS UV by Neptune Benson M6 stud Mild steel stud M6 Polyacetal NEMA6 (IP67) AT-573 PT-100 +/- 1°C 100 ohms at 100°C Not applicable, no direct contact with fluid 4 pin -50°C up to + 70°C * -50°C up to + 70°C Only calibrated 0°C up to 100°C neptunebenson.com • ets-uv.com • 238 Commercial Drive Beaver Dam, WI 53916 • 920.885.4628 2015 03