T4516 - Kurt Versen

Housing
Lamps (2)
(By Others)
Heat
Sink
Housing
Top
Rectangular
Trim
Spread Lens
Rail
Support
Vertical
Adjustment
T4516
Lens Wall Washer
Rectangular Parabolic Splay Trim
Two MR-16 LED and Low Voltage Lamps
4 1/2" x 8 1/2" Aperture
Optics and Applications
Kicker reflector redirects spill light through a Solite
spread lens. The rectangular shape uses two lamps for
uniform brightness on the lens producing wide lateral
spread and even illumination from ceiling to floor. Use to
light walls, murals, paintings, and textured surfaces such
as stone, masonry or wood. Parallel wall washers match
adjacent downlights.
D
Vent
Slot
PROJECT:
TYPE:
UE
Torsion
Spring
DATE:
Design Features
A steel housing protects all fixture components and is
ventilated for cool lamp chamber temperature. The splay
trim is held to the ceiling by a torsion spring assembly.
Maximum ceiling thickness 7/8". Top or bottom service.
D
A
7 3/4"
197mm
B
Aperture
C
Width
4 1/2" x 8 1/2" 18"
114mm x
457mm
216mm
D
Length
18 3/4"
476mm
DI
SC
T4516
A
Depth
Rev1 Date 2/25/2016
C
O
Number
B
Transformers
Electronic transformers are recommended for use with LED
lamps. Standard fixtures are provided with two transformers
capable of accommodating low voltage lamps up to 71W.
The primary lead is 120V with a 12V secondary. The
transformers are rated 180°C, Class H with a built-in 150°
resetting thermal link fuse. They can be lowered through
the aperture for service. Maximum fixture draw is 160W.
NT
Dimensions and Lamps
IN
Finish
Housings and structural parts are painted matte black
to suppress stray light leaks. The aperture trim is
Softglow® clear. A variety of colors are available.
Lamps
Two 12V MR-16
LED and low voltage
lamps to 71W
General
Fixtures are pre-wired, thermally protected, UL and C-UL
listed for eight wire 75°C branch circuit wiring. All products
are union made. Designed and manufactured in the USA.
Warranty
5 Year Warranty. See www.kurtversen.com for details
or select hyperlink.
Accessories
SB
Softglow black trim.
R2 26" support rails.
SG
Softglow gold trim.
R5 52" support rails.
SW
Softglow wheat trim.
WT White trim flange.
SY
Softglow pewter trim.
WHT White complete trim.
WRL Wattage restriction label, specify wattage.
ET1 Electronic transformer 120V to 12V.
ET2 Electronic transformer 277V to 12V.
V277-2 Primary transformers, 277 volt.
©2016 Kurt Versen, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Kurt Versen reserves the right
to change specifications without notice. One Paragon Drive, Suite 157, Montvale, NJ 07645 / Tel 201.664.8200 / Website www.kurtversen.com
T4516
85°
60
75°
Wall Washer
85°
75°
120
65°
65°
180
240
55°
55°
300
45°
45°
360
420
480
35°
35°
540
600
720
25°
780
5°
T4516 Two 50W MR-16 EXN
5°
900
240
320
55°
400
45°
480
560
640
35°
720
85°
65°
55°
45°
35°
O
800
880
960
25°
25°
1040
1120
DI
SC
15°
5°
T4516 Two 71W MR-16 EYC
Brightness
Number Lamps
T4516
Two 50W MR-16 EXN
Two 71W MR-16 EYC
5°
1200
85°
36
47
20
12
11
11
3'
40
39
29
25
22
21
17
2'
4'
5'
6'
8'
9'
48
30
22
17
13
10
8
6
45
30
22
36
21
15
75°
116
158
65°
172
229
15°
55°
45°
692
1449
507
28
20
15
17
12
10
7
6
11
9
7
5
4
11
8
6
5
4
T4516 Two 50W MR-16 EXN
75°
160
65°
29
10'
15°
Wall Washer
80
75°
32
1062
Data in footlamberts. Photometer readings, Maximum Brightness Method.
4' from wall
19
20
17
18
6
5
4
5
2
14
11
11
9
6
12
11
11
16
12
15
14
9
8
7
14
11
9
7
6
2' from wall
4
19
16
13
12
11
9
8
14
11
9
7
6
10
8
7
6
5
10
8
7
5
5
10
9
8
6
6
3' from wall
10
9
7
6
5
7
6
5
4
4
7
7
6
6
5
4
4
4' from wall
From
2' Centers 3' Centers 3' Centers 4' Centers 4' Centers 6' Centers
Ceiling
CL Mid CL Mid CL Mid CL Mid CL Mid CL Mid
1'
46
41
38
25
15
13
13
3'
52
50
37
33
27
26
22
NT
85°
Downlight
36
IN
15°
840
3' from wall
1'
7'
660
25°
2' from wall
From
2' Centers 3' Centers 3' Centers 4' Centers 4' Centers 6' Centers
Ceiling
CL Mid CL Mid CL Mid CL Mid CL Mid CL Mid
D
Downlight
Multiple Units Footcandles
UE
Candlepower Distribution Curves
Cut out dimensions: 9 5/32" x 5 5/32". Outer flange dimension: 9 5/8" x 5 5/8".
2'
4'
5'
6'
7'
8'
9'
10'
61
39
29
21
16
12
10
8
58
38
28
21
16
12
10
8
46
27
20
14
11
8
7
5
36
25
19
14
11
8
6
5
T4516 Two 71W MR-16 EYC
25
25
21
18
14
12
10
8
23
24
21
17
14
11
9
8
8
7
5
6
2
14
11
8
14
11
20
15
12
10
20
17
15
15
16
13
11
9
7
6
18
15
13
10
9
7
6
15
15
13
11
10
8
7
13
11
10
8
7
9
12
9
8
7
6
5
6
9
9
8
7
6
6
5
Notes
1 Increasing the spacing between fixtures will decrease wall illumination.
Decrease equals table spacing divided by new spacing times table average.
2 To increase wall illumination level, decrease spacing between fixtures.
Increase equals table spacing divided by new spacing times table average.
3 Above data measures output of the wall washers only. No contribution from
adjacent downlights or ceiling, floor or wall reflectances is included. Total
illumination on the wall will increase with the contribution from other sources.
4 Data is cosine corrected to the plane of the wall. Uncorrected data is
substantially higher and depends upon the angle of incidence to the wall
which varies with the mounting distance from the wall.
One Paragon Drive, Suite 157, Montvale, NJ 07645 / Tel 201.664.8200 / Website www.kurtversen.com
©2016 Kurt Versen, a division of Hubbell Lighting, Inc. / T4516 / Rev1 Date 2/25/2016
Because of continuing product improvement programs, Kurt Versen reserves the right to change specifications without notice.