macviperperformance, Standard (beamsmoother removed) , Zoom at Minimum (10°) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9 - 2001 Product Catalog number Lens Option Spread IES file MAC Viper Performance 90233100 Standard without beamsmoother Minimum MACViperPerformance_Standard without beamsmoother_Minimum.ies Procedure The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 1° increments in the horizontal plane (rotational) and 1° increments in the vertical plane (radial). Test lamp Model Rated wattage Rated life Rated color temp. Rated voltage Rated output Osram HTI 1000/PS Lok-it! 1000 W 750 hours 6000 K 82 V 85000 lumens Test conditions Ambient temperature Consumed power Lamp wattage AC supply Lamp adjustment Lamp age Focus Gate diameter Color inserted Effects inserted 25 ± 5 ºC 1174 W 1000 W 230 V/50Hz Peak distribution 2 hours Open gobo 36 mm no no Ballast Type Ballast factor Electronic 1.000 Output Total One-tenth peak Half-peak Efficiency Efficacy 23500 lumens 23400 lumens 22800 lumens 28 % 20 lumens per watt Illuminance Cutoff angle One-tenth-peak angle Half-peak angle Cutoff diameter One-tenth-peak diam. Half-peak diam. 10° 9.5° 8.5° 0.175 x distance 0.166 x distance 0.149 x distance Intended throw Focus range 4 - 45 meters 2 meters to infinity Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Luminous intensity Luminaire type 1533000 candela Far field 100%=1,408fc at 33ft (distance from origin)=(throw distance) X (throw distance multiplier) Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 macviperperformance, Standard Lens , Zoom at Minimum (11°) Photometric Report Martin R&D Optics Laboratory, 22-May-2013 Data sheet conforms to American National Standard E1.9 - 2001 Product Catalog number Lens Option Spread IES file MAC Viper Performance 90233100 Standard (with beamsmoother) Minimum MACViperPerformance_Standard_Minimum.ies Procedure The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 1° increments in the horizontal plane (rotational) and 1° increments in the vertical plane (radial). Test lamp Model Rated wattage Rated life Rated color temp. Rated voltage Rated output Osram HTI 1000/PS Lok-it! 1000 W 750 hours 6000 K 82 V 85000 lumens Test conditions Ambient temperature Consumed power Lamp wattage AC supply Lamp adjustment Lamp age Focus Gate diameter Color inserted Effects inserted 25 ± 5 ºC 1174 W 1000 W 230 V/50Hz Peak distribution 2 hours Open gobo 36 mm no no Ballast Type Ballast factor Electronic 1.000 Output Total One-tenth peak Half-peak Efficiency Efficacy 22000 lumens 22000 lumens 20800 lumens 26 % 18.8 lumens per watt Illuminance Cutoff angle One-tenth-peak angle Half-peak angle Cutoff diameter One-tenth-peak diam. Half-peak diam. 11° 10.5° 9° 0.193 x distance 0.184 x distance 0.157 x distance Intended throw Focus range 4 - 45 meters 2 meters to infinity Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Luminous intensity Luminaire type 1262000 candela Far field 100%=1,159fc at 33ft (distance from origin)=(throw distance) X (throw distance multiplier) Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 macviperperformance, Standard Lens , Zoom at Median (21°) Photometric Report Martin R&D Optics Laboratory, 22-May-2013 Data sheet conforms to American National Standard E1.9 - 2001 Product Catalog number Lens Option Spread IES file MAC Viper Performance 90233100 Standard (with beamsmoother) Median MACViperPerformance_Standard_Median.ies Procedure The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 1° increments in the horizontal plane (rotational) and 1° increments in the vertical plane (radial). Test lamp Model Rated wattage Rated life Rated color temp. Rated voltage Rated output Osram HTI 1000/PS Lok-it! 1000 W 750 hours 6000 K 82 V 85000 lumens Test conditions Ambient temperature Consumed power Lamp wattage AC supply Lamp adjustment Lamp age Focus Gate diameter Color inserted Effects inserted 25 ± 5 ºC 1174 W 1000 W 230 V/50Hz Peak distribution 4 hours Open gobo 36 mm no no Ballast Type Ballast factor Electronic 1.000 Output Total One-tenth peak Half-peak Efficiency Efficacy 23300 lumens 23200 lumens 21600 lumens 27 % 19.8 lumens per watt Illuminance Cutoff angle One-tenth-peak angle Half-peak angle Cutoff diameter One-tenth-peak diam. Half-peak diam. 21° 21° 18° 0.371 x distance 0.371 x distance 0.317 x distance Intended throw Focus range 4 - 45 meters 2 meters to infinity Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Luminous intensity Luminaire type 335000 candela Far field 100%=308fc at 33ft (distance from origin)=(throw distance) X (throw distance multiplier) Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 macviperperformance, Standard (beamsmoother removed) , Zoom at Median (20°) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9 - 2001 Product Catalog number Lens Option Spread IES file MAC Viper Performance 90233100 Standard without beamsmoother Median MACViperPerformance_Standard without beamsmoother_Median.ies Procedure The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 1° increments in the horizontal plane (rotational) and 1° increments in the vertical plane (radial). Test lamp Model Rated wattage Rated life Rated color temp. Rated voltage Rated output Osram HTI 1000/PS Lok-it! 1000 W 750 hours 6000 K 82 V 85000 lumens Test conditions Ambient temperature Consumed power Lamp wattage AC supply Lamp adjustment Lamp age Focus Gate diameter Color inserted Effects inserted 25 ± 5 ºC 1174 W 1000 W 230 V/50Hz Peak distribution 4 hours Open gobo 36 mm no no Ballast Type Ballast factor Electronic 1.000 Output Total One-tenth peak Half-peak Efficiency Efficacy 25700 lumens 25700 lumens 24600 lumens 30 % 21.9 lumens per watt Illuminance Cutoff angle One-tenth-peak angle Half-peak angle Cutoff diameter One-tenth-peak diam. Half-peak diam. 20° 20° 18° 0.353 x distance 0.353 x distance 0.317 x distance Intended throw 4 - 45 meters Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Focus range Luminous intensity Luminaire type 2 meters to infinity 384000 candela Far field 100%=353fc at 33ft (distance from origin)=(throw distance) X (throw distance multiplier) Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 macviperperformance, Standard (beamsmoother removed) , Zoom at Maximum (44°) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9 - 2001 Product Catalog number Lens Option Spread IES file MAC Viper Performance 90233100 Standard without beamsmoother Maximum MACViperPerformance_Standard without beamsmoother_Maximum.ies Procedure The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 2° increments in the horizontal plane (rotational) and 2° increments in the vertical plane (radial). Test lamp Model Rated wattage Rated life Rated color temp. Rated voltage Rated output Osram HTI 1000/PS Lok-it! 1000 W 750 hours 6000 K 82 V 85000 lumens Test conditions Ambient temperature Consumed power Lamp wattage AC supply Lamp adjustment Lamp age Focus Gate diameter Color inserted Effects inserted 25 ± 5 ºC 1174 W 1000 W 230 V/50Hz Peak distribution 2 hours Open gobo 36 mm no no Ballast Type Ballast factor Electronic 1.000 Output Total One-tenth peak Half-peak Efficiency Efficacy 26000 lumens 26000 lumens 24200 lumens 31 % 22.1 lumens per watt Illuminance Cutoff angle One-tenth-peak angle Half-peak angle Cutoff diameter One-tenth-peak diam. Half-peak diam. 44° 43° 39° 0.808 x distance 0.788 x distance 0.708 x distance Intended throw 4 - 45 meters Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Focus range Luminous intensity Luminaire type 2 meters to infinity 83000 candela Far field 100%=76fc at 33ft (distance from origin)=(throw distance) X (throw distance multiplier) Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 macviperperformance, Standard Lens , Zoom at Maximum (46°) Photometric Report Martin R&D Optics Laboratory, 22-May-2013 Data sheet conforms to American National Standard E1.9 - 2001 Product Catalog number Lens Option Spread IES file MAC Viper Performance 90233100 Standard (with beamsmoother) Maximum MACViperPerformance_Standard_Maximum.ies Procedure The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 2° increments in the horizontal plane (rotational) and 2° increments in the vertical plane (radial). Test lamp Model Rated wattage Rated life Rated color temp. Rated voltage Rated output Osram HTI 1000/PS Lok-it! 1000 W 750 hours 6000 K 82 V 85000 lumens Test conditions Ambient temperature Consumed power Lamp wattage AC supply Lamp adjustment Lamp age Focus Gate diameter Color inserted Effects inserted 25 ± 5 ºC 1174 W 1000 W 230 V/50Hz Peak distribution 20 hours Open gobo 36 mm no no Ballast Type Ballast factor Electronic 1.000 Output Total One-tenth peak Half-peak Efficiency Efficacy 23800 lumens 23800 lumens 21200 lumens 28 % 20.3 lumens per watt Illuminance Cutoff angle One-tenth-peak angle Half-peak angle Cutoff diameter One-tenth-peak diam. Half-peak diam. 46° 45° 40° 0.849 x distance 0.828 x distance 0.728 x distance Intended throw Focus range 4 - 45 meters 2 meters to infinity Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Luminous intensity Luminaire type 74000 candela Far field 100%=68fc at 33ft (distance from origin)=(throw distance) X (throw distance multiplier) Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10 Olof Palmes Allé 18, 8200 Århus N, Denmark Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
© Copyright 2026 Paperzz