Certus 140 Certus 140 ™ ™ 2.45GHz Ablation System - Probe Specifications 2.45GHz Ablation System Certus 140 Ablation Probes were designed to meet clinical needs and help ensure patient safety. Percutaneous Guide to Power and Time probes are minimally-invasive, industry leading 17 gauge to help minimize the risk of complications during probe placement. The patented triaxial antenna design offers high power, and efficient energy delivery to achieve tissue ablation/coagulation, including for hemostasis. Certus 140 Ablation Probes are specially designed to be highly visible under CT and Ultrasound to help ensure proper placement into the tissue. The revolutionary CO 2 cooling system offers Tissu-Loc Technology, enabling TM physicians to secure probes in tissue to limit the risk of probe migration and improve safety. The Certus 140 probe portfolio is comprised of CertusLK models that were designed to work optimally in liver or kidney tissue, maximizing the delivery of microwave energy in these tissue types, CertusLN models that were designed to work optimally in lung tissue, and the Certus SR designed for use in open surgical procedures offering a longer probe for targeting deep tissue. To learn more about these products please visit ™ www.neuwave.com 5.9 cm 1.4 cm 15, 20 or 25 cm Specifications Available Lengths Cable Length Temperature Part # 15, 20, 25cm 4.6 ' (1.4m) Active zone displayed. Three independent sensors provide continuous monitoring. Description UOM 6.0 cm LN15 Certus LN Ablation Probe, 15cm LN20 Certus LN Ablation Probe, 20cm 1 LK15 Certus LK Ablation Probe, 15cm 1 LK15-2 Certus LK Ablation Probe, 15cm 2 LK20 Certus LK Ablation Probe, 20cm 1 SR25 Certus SR Ablation Probe, 25cm 1 1 2.4 cm 5.7 cm ™ P L - 0 0 0 0 2 0 R E V- B 0 2 / 2 0 1 1 3529 Anderson Street Madison, WI 53704 877-323-WAVE(9283) [email protected] www.neuwave.com Certus LK Single Probe Ablations Certus SR Single Probe Ablations Certus LK Probes (LK15 and LK20) in Bovine Liver - Ex-Vivo Time Length (B) Diameter (A) Axial Area 6.0cm 7.0cm 3.7cm 4.0cm 17.6cm 2 22.4cm 2 5.5cm 6.2cm 3.6cm 4.3cm 15.2cm 2 19.9cm 2 3.6cm 4.3cm Diameter (A) Time Axial Area 5 Minutes 10 Minutes 4.4cm 6.4cm 5 Minutes 10 Minutes 2.6cm 3.3cm 7.3cm 2 11.2cm 2 2.5cm 3.4cm Diameter (A) Time Axial Area 5 Minutes 10 Minutes 9.3cm 2 18.0cm 2 2.4cm 3.3cm 6.0cm 6.8cm 5 Minutes 10 Minutes 7.7cm 2 14.5cm 2 3.4cm 4.7cm 5 Minutes 10 Minutes 16.2cm 2 26.4cm 2 1.9cm 1.9cm 4.6cm 5.2cm 5 Minutes 10 Minutes 4.5cm 2 5.0cm 2 Diameter (A) Axial Area 4.8cm 5.7cm 2.8cm 3.1cm 12.3cm 2 15.1cm 2 2.0cm 2.9cm 6.2cm 2 14.3cm 2 1.9cm 2.5cm 4.5cm 2 7.0cm 2 90W Power Setting 3.3cm 3.9cm 5 Minutes 10 Minutes 12.1cm 2 16.3cm 2 3.6cm 5.8cm 40W Power Setting 40W Power Setting 2.7cm 3.0cm Length (B) 140W Power Setting 90W Power Setting 3.5cm 5.5cm 5 Minutes 10 Minutes Length (B) Certus SR Probes in Bovine Kidney - Ex-Vivo 140W Power Setting 40W Power Setting 40W Power Setting 5 Minutes 10 Minutes Length (B) 90W Power Setting 90W Power Setting 5 Minutes 10 Minutes Time 140W Power Setting 140W Power Setting 5 Minutes 10 Minutes Certus SR Probes in Bovine Liver - Ex-Vivo Certus LK Probes (LK15 and LK20) in Bovine Kidney - Ex-Vivo 3.6cm 4.1cm 2.6cm 3.6cm 5 Minutes 10 Minutes 7.0cm 2 11.3cm 2 2.7cm 3.3cm The size of ablation zones may vary in clinical settings due to vasculature structure and the cooling effect of blood flow not present in ex-vivo tissue. The size of ablation zones may vary in clinical settings due to vasculature structure and the cooling effect of blood flow not present in ex-vivo tissue. Certus LN Single Probe Ablations Certus LK Multiple Probe Ablations Certus SR Multiple Probe Ablations Two Probe Ablation Two Probe Ablation Certus LN Probes (LN15 and LN20) in Bovine Lung - Ex-Vivo Time Length (B) Diameter (A) Certus LK Probes (LK15 and LK20) in Bovine Liver - Ex-Vivo Axial Area 140W Power Setting 5 Minutes 10 Minutes 6.0cm 6.0cm 4.6cm 5.4cm 3.3cm 3.9cm 15.6cm 2 19.3cm 2 1.7cm 3.8cm Space (S) Length (B) Diameter (A) Axial Area 10 Min. 2.0cm 6.3cm 3.1cm 3.5cm 11.7cm 2 15.8cm 2 0.8cm 2.3cm 1.2cm 2 9.8cm 2 10 Min. 2.0cm 5.7cm Time Space (S) Length (B) Diameter (A) Axial Area 2 Probe - 95W Power Setting 4.8cm 20.3cm 2 3 Probe - 65W Power Setting 40W Power Setting 5 Minutes 10 Minutes Time Three Probe Ablation Certus SR Probes in Bovine Liver - Ex-Vivo 2 Probe - 95W Power Setting 90W Power Setting 5 Minutes 10 Minutes Three Probe Ablation 10 Min. 2.0cm 6.5cm 5.0cm 21.4cm 2 4.2cm 18.2cm 3 Probe - 65W Power Setting 4.5cm 19.0cm 2 Based upon ex-vivo results, NeuWave Medical recommends a maximum of 2cm spacing between probes. This results in a contiguous ablation. Ablations spaced more than 2cm may have non-contiguous results. Ablations spaced a minimum of 8cm resulted in 3 independent ablations zones that did not overlap. 10 Min. 2.0cm 5.7cm ™ 2 Based upon ex-vivo results, NeuWave Medical recommends a maximum of 2cm spacing between probes. This results in a contiguous ablation. Ablations spaced more than 2cm may have non-contiguous results. Ablations spaced a minimum of 8cm resulted in 3 independent ablations zones that did not overlap.
© Copyright 2026 Paperzz