Immersion Viscosity Cups according/similar to ISO 2431

PRODUCT DATASHEET v01.01
Immersion Viscosity Cups according/similar to ISO 2431
Product
Description:
The process of flow through an orifice can often be used as a relative measurement and classification of viscosity.
This measured kinematic viscosity is generally expressed in seconds of flow time which can be converted into
Centistokes using a viscosity disc calculator. Dip cups can be used to provide a quick viscosity measurement on the
shop floor or on site.
Standards:
Compatible with/ similar to ISO 2431
Application/
application area’s:
Laboratory, manufacture
Features:
- Each cup has a long loop handle to allow the cup to be dipped by hand into a liquid container, which makes it easy to
quickly check and adjust the viscosity of many different type of liquids.
- The design of the cup and orifice eliminate hard to clean recesses.
- TQC viscosity cups are made under the continuing quality control procedures.
- Each cup is provided with an engraved unique serial number.
Standard delivery:
Each viscosity cup comes with a hard plastic storage case, with protective soft material on the inside.
Optional items:
VF2210
DI0076
VF2053
Use:
► According to the standard all measurements should be made at 23°C. Temperature drift during the test should be
kept to a minimum and should not exceed ± 0,2 °C. Adjust the temperature of the material to be measured if
necessary.
► Select the proper orifice to be used from the specification table, which depends on the expected viscosity range of
the material to be measured. Lower the cup into the material so that the top rim is submerged.
► Place a thermometer into the cup as it is immersed and determine the temperature of the confined sample.
► Remove thermometer.
► Hold cup vertically by inserting index finger into handle ring. In a quick, steady motion, lift the cup out of the sample
material, starting the timer when the cup breaks the surface. During the flow time, hold the cup no more than 15 cm
above the level of the sample material.
► Stop the timer when the first definite break in the stream at the base of the cup is observed.
Technical data:
Immersion Viscosity Cup Type TI
Cup:
titanium anodized aluminium,
Nozzle:
stainless steel, fixed
Handle:
stainless steel.
Comp. with: ISO 2431 (3,4,5,6)
Weight
281-282 gram*
Max. Width: 74 mm
Cup width:
64 mm
Cup height: 84 mm
Total height: 250 mm
*(depending on orifice)
Thermimport Quality Control
Test certificate, type M, for cup type TI 3,4, 5 and 6 mm
Stopwatch Type C510 digital LCD-display, 9h. 59 min. 59,99 sec.
Viscosity Conversion Disc
Tel: +31 0180-631344
Fax: +31 0180-632917
Article
Number
Product
Descr.
Ø Orifice
(mm)
Viscosity
Range (cSt)
Flow times
(sec)
VF2089
VF2090
VF2091
VF2185
VF2092
VF2093
2
2
3
3
7-42
30-100
4
4
34-135
30-100
5
5
91-326
30-100
6
6
188-684
30-100
8
8
600-2000
30-100
* For information purposes only; all approximate values at 25 °C.
Website: http://www.tqcinfo.com
Email: [email protected]
Page 1 of 2
PRODUCT DATASHEET v01.01
Technical data:
(cont.)
Immersion Viscosity Cup Type TFR
Cup:
stainless steel, 100 cc
Nozzle:
stainless steel, fixed
Handle:
stainless steel.
Comp. with: ISO 2431 (3,4,6)
Weight
746-755 gram*
Max. Width: 74 mm
Cup width:
64 mm
Cup height: 84 mm
Total height: 250 mm
*(depending on orifice)
Article
Number
Product
Descr.
Ø Orifice
(mm)
Viscosity
Range (cSt)
Flow times
(sec)
VF2220
VF2221
VF2222
VF2224
VF2225
2
2
3
3
7-42
30-100
4
4
34-135
30-100
6
6
188-684
30-100
8
8
600-2000
30-100
* For information purposes only; all approximate values at 25 °C.
Special care:
With reasonable care, a viscosity cup is constructed to give many years of satisfactory service. To clean the instrument,
use a soft cloth, NEVER clean by any mechanical means, such as steel brushes, sandpaper or other abrasive tools.
Particular care should be used in cleaning the orifice to avoid leaving deposits or scratches on internal surfaces.
It’s recommended to clean the cup promptly after each use, unless it will be used immediately for a rerun of the same
material.
Safety Precautions:
Determining viscosity may involve hazardous materials, operations and equipment. It is the responsibility of the executor
to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to the
measurement.
Disclaimer:
The information given in this sheet is not intended to be exhaustive and any person using the product for any purpose
other than that specifically recommended in this sheet without first obtaining written confirmation from us as to the
suitability of the product for the intended purpose does so at his own risk. Whilst we endeavour to ensure that all advice
we give about the product (whether in this sheet or otherwise) is correct we have no control over either the quality or
condition of the product or the many factors affecting the use and application of the product. Therefore, unless we
specifically agree in writing to do so, we do not accept any liability whatsoever or howsoever arising for the performance
of the product or for any loss or damage (other than death or personal injury resulting from our negligence) arising out of
the use of the product. The information contained in this sheet is liable to modification from time to time in the light of
experience and our policy of continuous product development.
Thermimport Quality Control
Tel: +31 0180-631344
Fax: +31 0180-632917
Website: http://www.tqcinfo.com
Email: [email protected]