Fans | Air Handling Units | Air Distribution Products | Air Conditioning | Fire Safety | Air Curtains and Heating Products | Tunnel Fans Danvent DV 190 and 240 Air Handling Units with High Capacity Danvent DV 190 and 240 Danvent DV 190 and 240 A modular air handling unit The Danvent DV 190 and 240 are designed as modular air handling units. Each function is placed into an air handling unit casing consisting of one or more modules. The modular functions can be configured for many different applications to make up the heart of any ventilation system. The Danvent DV 190 and 240 are continually being opti mized and added improvements. The result is extremely flexible air handling units, both in terms of design and function. The air handling units are produced in Denmark. At the Danish Systemair factory we have manufactured air hand ling units since 1977. Systemair in Denmark houses the group’s expertise for large air handling units. We focus on development, manufacturing, sales, and consultations. AHU No 07.02.339 DANVENT DV 10-240, TIME 10-40 ENERGY EFFICIENCY 339 2014 Report to performance data 2014 ErP ErP 2016 2018 Danvent DV 190 and 240 | Functions Sizes and airflows The Danvent DV comes in a range of 14 different sizes, with airflow capacities from 0,2-24 m /s or 75086.000 m /h. The sizes DV 190 and 240 are the largest units. The wide range makes it possible to always find the unit optimized for any given requirement. 3 3 Functions The DV 190 and 240 feature a number of well-dimensioned functions as standard. The functions facilitate easy handling on the building site and easy service access as well as ensuring high efficiencies and long service life. Dampers The dampers in DV 190 and 240 comply with EN 1751:2014, sealing class 3. The dampers ensure a long and trouble-free operation, as the blades are mounted on sturdy square profile shafts and service-free synthetic bearings with large bearing surfaces. 1000 1500 2000 3000 Filters In the DV 190 and 240 the filters are held in separate frames with effective springs. This also applies for DVG pre-filters. Wall with EC fans Fans with EC motors are available. The desired airflow can be achieved with the parallel running of up to 5 EC fans in each airflow. The fans are distributed in a way that ensures an even distribution of the airflow in the unit. A minimum of space is required for the wall of fans and thus the building length will be shorter accordingly. Heat exchangers The DV 190 and 240 are available with rotary heat exchangers which are always supplied divided. The DV 190 and 240 are also available with run-around coils. SystemairCAD The product selection programme, SystemairCAD, ensures optimal design of the air handling unit functions. The programme is very user-friendly and makes it possible to quickly and easily combine air handling unit functions and perform technical calculations. Heating and cooling coils The DV 190 and 240 are available with coils for hot water and chilled water. A drip tray is standard for the cooling coils. Fans 2 directly driven plug fans for frequency control are standard in the DV 190 and 240 (frequency converters are optional). By using 2 fans an even distribution of the airflow is ensured on the entire width of the unit. 5000 10000 20000 30000 50000 90000 m3/h Airflow range for the unit size. DV 240 DV 190 DV 150 DV 120 DV 100 DV 80 DV 60 DV 50 DV 40 DV 30 DV 25 DV 20 DV 15 DV 10 0,2 0,3 0,4 0,7 1 2 3 5 10 15 20 25 m3/s 3 4 | Danvent DV 190 and 240 Functions DV with wall of EC fans. SystemairCAD calculates and optimizes the energy consumption and the calculated data are the basis for Eurovent certification and energy classification of Danvent DV. The programme uses a number of combination examples or basic versions. From these examples one can quickly add or remove features in order to easily design the desired air handling unit. The drawn to scale drawings plus logical construction and presentation of technical data provide easy overview. The drawings can easily be exported to other CAD software. SystemairCAD has plug-ins for the CAD software MagiCAD for AutoCAD and Revit. The plug-ins make it possible to insert Systemair air handling units directly into MagiCAD, AutoCAD, and Revit. SystemarCAD can be downloaded from systemair.com. Casing The DV 190 and 240 are built to last for many years. The frame profiles and panels are made of steel sheets protected with alu-zink AZ 185 – providing a good corrosion protection. Frame profiles and corners The DV 190 and 240 are constructed using strong, closed and all-welded steel framing profiles. With the cast aluminium corners the result is a strong and robust construction able to resist twisting and lateral movement, making the units extremely stable and strong. Panels The panels of the DV 190 and 240 are built using a sandwich construction with double sheets and 50 mm mineral wool for sound and heat insulation. The panels with alu-zinc surface are not only highly corrosionresistant, but present an attractive, uniform appearance that can last for many years. Steel sheets which are protected with alu-zinc AZ185 ensure a corrosion protection in class C4 according to EN ISO 12944-2:2000. Base frame and sections All DV 190 and 240 sections have a strong and rigid base frame with lifting brackets. Some sections may contain more than one function, and these sections will have their own base frames. The base frame is part of the casing, and it is not possible to demount the base frame. Also for units in 2 levels (supply air and exhaust air in 2 levels) the base frame is necessary under the upper casing to keep the whole unit rigid, and it will ensure easy transport. Assembly of sections The lifting brackets are removed from the base frames and the base frames are bolted together. Brackets keep the top of the sections together. Inspection doors The DV 190 and 240 have large inspection doors, making service access easy. The doors are mounted using solid hinges with easily remo vable stainless steel pins. The doors are sealed using rubber profiles and locks with heavy-duty handles. They can only be opened using a key. Transport and lift The length of each section does not exceed 2470 mm. For easy internal transport with a fork-lift truck with extra long forks, 100 mm high wood blocks are bolted under each corner of the base frame. NOTE! Do not under any circumstan ces lift the section with forks that are shorter than the section! Ready to lift. Base frames are connected. When the sections are lifted by straps to the final destination, it must be carried out by using the lifting brackets on the base frame, and distance pipes must be used above the section. Danvent DV 190 and 240 | Combination Examples Rotary heat exchanger 190 240 190 240 Unit Width 3190 3490 Unit Width 3190 3490 Rotary heat exchanger section Width 3720 4020 Single height unit Height 2170 2470 Unit Height 4340 4940 Double height unit Height 4340 4940 5010 5530 R1 Length 5010 5230 Weight kg 6290 7610 Weight kg 6290 7420 Length 5910 6060 Weight kg 7050 8270 190 240 C1 Length C2 Length C3 C4 C5 C6 Run-around coil heat exchanger R2 5980 6430 Weight kg 7220 8600 Length 6430 7100 Weight kg 6870 8280 Length 7400 8000 Supply air Weight kg 7790 9180 Unit Width 3190 3490 6430 7100 Single height unit Height 2170 2470 Weight kg 6860 8280 Double height unit Height 4340 4940 S1 Length 4040 4260 Length 7400 8000 Weight kg 2250 2820 Weight kg 7790 9170 S2 Length 5010 5160 Weight kg 3170 3720 Length 4040 4260 Weight kg 3690 4560 Length 5010 5160 Weight kg 4610 5460 Length S3 Recirculated air 190 240 Unit Width 3190 3490 Single height unit Height 2170 2470 Double height unit Height 4340 4940 M1 Length 4410 5080 Weight kg 2320 3040 Length 5380 5980 Weight kg 3250 3940 Design an air handling unit Length 7550 8820 Weight kg 3930 5100 Length 8520 9720 Weight kg 4850 6000 Danvent DV contains countless combination options. To ease the process of designing a unit the most popular combinations are illustrated here. Length 4710 5080 Weight kg 4190 5150 Length 5680 5980 Weight kg 5110 6050 M2 M3 M4 M5 M6 S4 Key to symbols Exhaust air Outdoor air Extract air Supply air The above dimensions and weights are a guideline only. Accurate values and combinations are calculated in SystemairCAD. The heights are incl. base frames. 5 6 | Danvent DV 190 and 240 Dimensions The main dimension as well as the sizes of the connections to ducts appear from the table below. All capacities of heating, cooling and heat recovery are calculated and optimized individually in the SystemairCAD design programme. The dimensions of pipes will appear from these SystemairCAD calculations. Unit size 190 Main dimensions of the unit W x H 240 3190 x 2170 mm 3490 x 2470 mm W rotary heat exchanger 3720 mm W rotary heat exchanger 4020 mm 2700 mm 3000 mm Variant B (DVA, DVP) 2600 x 1500 mm 2800 x 1800 mm Variant C (DVB, DVM) 2600 x 1000 mm 2800 x 1200 mm Variant D (DVE, DVH, DVK, DVF) 3120 x 1950 mm 3420 x 2250 mm Variant E (DVE top connection) 3120 x 1500 mm 3420 x 1500 mm L (see Combination examples) Transport H for unassembled rotor Duct connections: Please note that the height of the unit always includes base frame. This also applies to the units in 2 levels. H 2xH H W L Danvent DV SystemairCAD A modular air handling unit To ensure optimal dimensioning and configuration of the air handling unit’s functions, we have developed the design programme SystemairCAD. The programme is very userfriendly and facilitates a simple and quick way to combine unit functions as needed. When you have completed the design of the air handling unit, SystemairCAD automatically performs all technical cal culations and documentation. The technical documentation is presented as a pdf-report specifically for the chosen air handling unit. SystemairCAD can also generate a complete specification text that is easy to adjust and copy to the tem plate of tender. This ensures that all values are correct. Systemair Plug-ins The drawn to scale drawings from SystemairCAD can easily be exported to other CAD software. The plug-ins make it pos sible to insert Systemair air handling units directly into MagiCAD, AutoCAD, and Revit. This makes it fast to connect the air handling unit to the ducting of the drawing in the overall BIM model. SystemairCAD is free for download on systemair.com. You are always welcome to call your local Systemair office for technical guidance or quotations. Important differences between the DV units Function DV 190 and 240 Other DV units DVG pre-filter: In separate frames Yes No In locking frames No Yes DVF filter: In separate frames Yes No In locking frames No Yes Heat recovery: Rotary heat exchanger Yes, divided Yes Plate heat exchanger No Yes Run-around coils Yes Yes 2 fans 1 fan/2 fans Fans: Plug fans Wall with EC fans Base frame Roof unit Yes Yes Always part of the casing Part of casing or separate No Yes www.systemair.com Systemair DK • May 2016 • V2-90933920
© Copyright 2024 Paperzz