! w e N !! aatt m rrm FFoo 99 ee aarr 88 && ddww ss aarr ggee HH ppaa SS M sseeee //M LLCC Versatile Packings for a Wide Range of Applications Acid and Base Deactivated for Symmetrical Peaks Stable Bonded Phases for Long Column Life A Large Selection of Hardware Formats Bulletin #458 Versatile Packings for a Wide Range of Applications What are You Looking for in an HPLC Column? Alltech’s Alltima™ HPLC Columns will satisfy the requirement of today’s applications! • Large Selection of Mobile Phase Chemistries, Particle Sizes, Porosities, and Column Formats • Extensive Collection of Published Applications • Demonstrated Stability for Acids, Bases, and Neutrals in a Wide Range of Mobile Phases Alltima’s performance and versatility are exemplified by the following applications. Antibacterials Natural Products 8764 1. Oxytetracycline Dihydrate 2. Tetracycline HCL 3. Meclocycline Sulfosalicylate Salt 3 1. 2. 3. 4. 5. 6. 2 1 1 2 3 8887 Naringin Neohesperidin Myricetin Quercetin Naringenin Kaempferol 5 6 4 0 2 4 6 8 0 10 Min. Column: Alltima™ C18, 3µm, 100 x 4.6mm Mobile Phase: A: 50mM KH2PO4, pH 3.0 B: CH3CN Gradient Time: 0 10 %B: 15 40 Flowrate: 1.0mL/min Detector: UV at 254nm Antihistamines 5 15 Min. 10 Alltima™ C18, 3µm, 100 x 4.6mm A: 50mM KH2PO4, pH 2.5 B: CH3CN Time: 0 15 %B: 20 40 1.0mL/min UV at 280nm Column: Mobile Phase: Gradient: Flowrate: Detector: Flavonoids 7232 4 9271 1 3 5 1. 2. 3. 4. 5. 2 2 Tripelennamine Triprolidine Cyclizine Chlorcyclizine Meclizine 1. 2. 3. 4. Myricetin Quercetin Apigenin Kaempferol 1 4 3 0 5 10 15 20 25 Min. Column: Alltima™ C18, 5µm, 250 x 4.6mm Mobile Phase: A: 50mM KH2PO4, pH 3.2 B: CH3CN Gradient: Time: 0 5 20 %B: 25 25 70 Flowrate: 1.3mL/min Detector: UV at 220nm © Copyright 2001 Alltech Associates, Inc. 2 0 1 Column: Mobile Phase: Flowrate: Detector: 2 3 4 5 Min. Alltima™ C18 Rocket™, 3µm, 53 x 7mm 0.1% TFA in H2O, pH 0.95:0.1% TFA in CH3CN(65:35) 2.5mL/min ELSD Contact your Alltech office or distributor for current or local prices. Versatile Packings for a Wide Range of Applications Taxol® and Related Taxanes in Yew (taxus brevifolia) 1. 10-deacetylbaccatin III 2. Baccatin III 3. 7-xylosyl-10-deacetyltaxol B 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 1 2 7 4,5 6 3 0 2 1 3 Column: Mobile Phase: Flowrate: Detector: 8 91011 4 13 12 5 6 7 7809 Taxinine M 7-xylosyl-10-deacetyltaxol 7-xylosyl-10-deacetyltaxol C 10-deacetyltaxol 7-xylosyltaxol Cephalomannine (Taxol® B) 7-epi-10-deacetyltaxol Taxol® Taxol® C 7-epitaxol 0 8 Min. ™ Tween 80 9221 ™ Alltima Phenyl Rocket , 3µm, 53x 7mm 0.05% TFA in H2O:MeOH:CH3CN (50:19:31) 2.5mL/min UV at 230nm Acids, Bases, and Neutrals 5 10 Column: Mobile Phase: Flowrate: Detector: 15 20 25 30 ™ Alltima C18, 5µm, 250 x 4.6mm H2O:MeOH (40:60) 1.0mL/min ELSD 5 8760 Anticonvulsants 7233 2 4 5 1 6 1. Uracil 2. Pyridine 3. Phenol 4. N,N-Dimethylaniline 5. 4-Butylbenzoic Acid 6. Toluene 1 23 4 6 3 0 0 1 Column: Mobile Phase: Flowrate: Detector: 1 Aromatic Acids 4 8 Column: Mobile Phase: Gradient: 2 3 4 5 Min. Alltima™ C18, 3µm, 100 x 4.6mm 50mM KH2PO4, pH3.0:CH3CN (40:60) 1.0mL/min UV at 254nm 3 Flowrate: Detector: 12 16 4 Alprazolam and Triazolam by the USP XXII Method 7373 7368 1. Triazolam 2. Alprazolam 1 2 5 0 0 1 2 3 4 5 6 7 8 9 10 11 Min. Column: Mobile Phase: Flowrate: Detector: 20 Min. Alltima™ Phenyl, 5µm, 250 x 4.6mm A: H2O B: CH3CN Time: 0 20 25 30 %B: 15 60 60 15 1.5mL/min UV at 254nm 1. DL-4-Hydroxy-3methoxy-mandelic Acid 2. Homovanillic Acid 3. Vanillic Acid 4. Salicylic Acid 5. Benzoic Acid 2 1. Ethotoin 2. Phenobarbital 3. Methsuximide 4. Mephenytoin 5. Carbamazepine 6. Diazepam Alltima™ C18, 5µm, 150 x 4.6mm 50mM KH2PO4, pH 3.2:MeOH (60:40) 1.0mL/min UV at 254nm Contact your Alltech office or distributor for current or local prices. 2 4 6 8 10 12 14 16 18 20 Min. Column: Alltima™ Silica, 5µm, 300 x 4.6mm Mobile Phase: CH3CN:CHCl3:i-BuOH:H2O:Glacial HOAc (85:8:5:2:0.05) Flowrate: 2.0mL/min Detector: UV at 254nm © Copyright 2001 Alltech Associates, Inc. 3 Acid and Base Deactivated for Symmetrical Peaks Alltima™ manufacturing processes eliminate activated silanols that cause peak tailing on silica-based columns. Alltima™ columns and simple mobile phases produce sharp, symmetrical peaks with acidic compounds, basic compounds and chelators. Metal Chelators Fatty Acids 8584 1 1. 2,2’-Dipyridyl 2. 8-Hydroxyquinoline 1 1. 2. 3. 4. 5. 2 8060 Capric Acid (C10) Lauric Acid (C12) Myristic Acid (C14) Palmitic Acid (C16) Stearic Acid (C18) 3 2 4 5 0 2 4 Column: Mobile Phase: Flowrate: Detector: Alltima™ C18, 5µm, 150 x 4.6mm 25mM K2HPO4, pH7.0:THF:MeOH (50:25:25) 1.0mL/min UV at 254nm 0 6 Min. Tricyclic Amines 4 Column: Mobile Phase: Flowrate: Detector: 6 8 10 12 Min. Alltima™ C18, 5µm, 150 x 4.6mm THF:CH3CN:0.1% H3PO4 (25:55:20) 1.5mL/min UV at 220nm OPA Derivatized Amino Acids 7366 1. Fluphenazine HCl 2. Chlorpromazine HCl 3. Phenothiazine 1 2 2 1. 2. 3. 4. 5. 6. 7. 1 11 13 9 2 8 5 10 6 3 4 3 0 5 12 14 Asp Glu His Ser Arg Gly Thr 15 7 10 15 7596 8. 9. 10. 11. 12. 13. 14. 15. Ala Tyr Met Val Phe Ileu Leu Lys 20 Min. ™ 0 1 2 3 Column: Mobile Phase: Flowrate: Detector: 4 5 6 7 Min. Alltima™ Cyano, 5µm, 250 x 4.6mm 50mM NaH2PO4, pH3.0: CH3CN (50:50) 1.5mL/min UV at 254nm © Copyright 2001 Alltech Associates, Inc. 4 Column: Alltima C8, 5µm, 100 x 4.6mm Mobile Phase: A: 50mM NaOAc, pH5.7:THF (95:5) B: MeOH Gradient: Time: 0 15 %B: 10 65 Flowrate: 2.0mL/min Detector: Fluorescence Ex: 305-395nm Em: 430-470nm Contact your Alltech office or distributor for current or local prices. Stable Bonded Phases for Long Column Life Figure 7 - An Alltima™ C18 column was washed for 500 hours at 60°C with an acetonitrile and trifluoroacetic acid mobile phase. The separation of peptides showed no change in capacity, selectivity, or efficiency. Alltima™ Acid Stability 7553 2 1 3 Alltima™ C18, 5µm 150 x 4.6mm Mobile Phase: A: 0.1% TFA in H2O:CH3CN (95:5), B: 0.1% TFA in H2O:CH3CN (25:75) Gradient: Time: 0 60 %B: 5 30 Flowrate: 1.0mL/min UV at 220nm 5 10 15 20 25 30 35 40 45 50 55 Min. Detector: 0 Column: 45 0 7554 1. Gly-Tyr 2. Val-Tyr-Val 3. Met-Enkephalin 4. Leu-Enkephalin 5. Angiotensin II Initial Separation After 500 Hours of Washing at 60°C 2 1 3 45 5 10 15 20 25 30 35 40 45 50 55 Min. Figure 8 - Alltima™ columns are packed by proven methods and don’t void or collapse when subjected to constant high pressure. This chromatography remains unchanged after 1,200 column volumes of a Methanol:Water (50:50) mobile phase pumped through the column at 2.0mL/min (backpressure 3,500psig). Alltima™ Withstands Continuous High Backpressure 8589 1. Uracil 2. Pyridine 3. Phenol 4. N,N-Dimethylaniline 5. 4-Butylbenzoic Acid 6. Toluene Initial Separation 1 5 4 3 2 6 0 4 2 6 8 8590 After 1200 Column Volumes of 50:50 MeOH:H2O at 2mL/min 1 5 2 Alltima™ C18, 5µm, 150 x 4.6mm Mobile Phase: 50mM KH2PO4, pH3.0: CH3CN (40:60) Flowrate: 1.0mL/min UV at 254nm 10 Min. Detector: 0 4 3 Column: 6 4 2 6 8 10 Min. Figure 9 - Drastic solvent polarity changes don’t affect Alltima™ Columns. After 58 cycles (29 hours) of Water ➝ Ethanol ➝ Hexane, chromatography remains unchanged. ➝ ➝ Alltima™ is Unaffected by Drastic Mobile Phase Polarity Changes Initial Separation 2 4 3 1 1 Column: 0 ➝ 4 3 After 58 Cycles of H2O ➝ EtOH ➝ Hexane 1. Uracil 2. Phenol 3. N,N-Diethyl-m-toluamide 4. Toluene 2 8588 ➝ 8587 2 4 6 8 10 Min. ™ Alltima C18, 5µm, 150 x 4.6mm Mobile Phase: 50mM KH2PO4, pH3.0: CH3CN (40:60) Flowrate: 1.0mL/min Detector: UV at 254nm 0 Contact your Alltech office or distributor for current or local prices. 2 4 6 8 10 Min. © Copyright 2001 Alltech Associates, Inc. 5 A Large Selection of Hardware Formats Alltima™ Phases are Extremely Well Suited for Applications Using MS Detection • Stable in Popular LC/MS Mobile Phases • No Bonded Phase Bleed • Analyze Acids, Bases, and Neutrals with Simple, Volatile Mobile Phases • Available in New Expedite™ Hardware for Fast, Low-Volume Applications Expedite™ hardware is available in 10 or 20mm lengths, and 2.1 or 4.6mm ID New! New! Steroids 1 9432 2 Actual Size 1. Prednisone 2. Testosterone 3. Cortisone 4. Progesterone 4 20mm 3 0 10mm Expedite your LC/MS analyses with Alltech’s high-speed, low-volume Expedite™ hardware. These fast analysis columns packed with high resolution Alltima™ media increase laboratory efficency by doubling or even tripling sample throughput. 1 Column: Mobile Phase: Flowrate: Detector: 2 Min. Alltima™ Phenyl, 3µm, 50 x 2.1mm 45% CH3CN:50mM Ammonium Acetate, pH5.4 0.4mL/min UV at 254nm Alltima™ LC/MS Columns PACKING C18 Expedite™ Expedite™ Expedite™ Expedite™ Phenyl Expedite™ Expedite™ Expedite™ Expedite™ Silica Expedite™ Expedite™ Expedite™ Expedite™ Barbiturates PARTICLE SIZE LENGTH X ID PART NO. 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 10 x 2.1mm 20 x 2.1mm 50 x 2.1mm 100 x 2.1mm 150 x 2.1mm 10 x 4.6mm 20 x 4.6mm 100 x 1.0mm 150 x 1.0mm 33 x 7mm 53 x 7mm 43836 43803 43849 43821 43852 43837 43851 43853 43864 50603 50605 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 10 x 2.1mm 20 x 2.1mm 50 x 2.1mm 100 x 2.1mm 150 x 2.1mm 10 x 4.6mm 20 x 4.6mm 100 x 1.0mm 150 x 1.0mm 53 x 7mm 43809 43865 43835 43866 43813 43883 43822 43892 43854 43867 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 3µm 10 x 2.1mm 20 x 2.1mm 100 x 2.1mm 150 x 2.1mm 50 x 2.1mm 10 x 4.6mm 20 x 4.6mm 100 x 1.0mm 150 x 1.0mm 53 x 7mm 43891 43801 43823 43884 43876 43889 43886 43824 43855 43877 © Copyright 2001 Alltech Associates, Inc. 6 9433 5 PRICE 2 1. Barbital 2. Phenobarbital 3. Talbital 4. Amobarbital 5. Mephobarbital 1 3 4 0 1 Column: Mobile Phase: Flowrate: Detector: 2 Min. Alltima™ C18, 3µm, 50 x 2.1mm 40% CH3CN:50mM Ammonium Acetate, pH5.4 0.5mL/min UV at 230nm Specifications for Alltima™ Packing Materials Alltima™ Packing Specifications C18 C18-WP C18-LL AQ New! C8 C4-WP Phenyl Cyano Amino Silica PARTICLE SIZE PORE SIZE CARBON LOAD ENDCAPPED 3, 5, 10µm 5µm 5µm 3, 5µm 3, 5, 10µm 5µm 3, 5µm 3, 5µm 3, 5µm 3, 5, 10µm 100Å 200Å 100Å 100Å 100Å 200Å 100Å 100Å 100Å 100Å 16% 17% 9% 15% 9% 6% 7.5% — — — Yes Yes Yes Yes Yes Yes Yes Yes No — Contact your Alltech office or distributor for current or local prices. A Large Selection of Hardware Formats Alltima™ Analytical Columns Alltima™ Cartridge Columns* LENGTH X ID INDUSTRY STANDARD PART NO. WATERS INSTRUMENT PART NO. 50 x 4.6mm 100 x 4.6mm 150 x 4.6mm 150 x 4.6mm 250 x 4.6mm 150 x 4.6mm 250 x 4.6mm 81412 81382 81387 88052 88056 88302 88307 — 81383 81388 88053 88057 88303 88308 5µm 5µm 3µm 3µm 150 x 4.6mm 250 x 4.6mm 100 x 4.6mm 150 x 4.6mm 88925 88930 88935 88940 88945 88950 88955 88960 C18-WP 5µm 5µm 150 x 4.6mm 250 x 4.6mm 81194 81196 81195 81197 C18-LL 5µm 5µm 150 x 4.6mm 250 x 4.6mm 88069 88099 88082 88235 3µm 3µm 3µm 5µm 5µm 10µm 10µm 50 x 4.6mm 100 x 4.6mm 150 x 4.6mm 150 x 4.6mm 250 x 4.6mm 150 x 4.6mm 250 x 4.6mm 81413 81392 81397 88072 88076 88312 88317 — 81393 81398 88073 88077 88313 88318 5µm 5µm 150 x 4.6mm 250 x 4.6mm 81198 81202 81199 81204 Phenyl 3µm 3µm 3µm 5µm 5µm 50 x 4.6mm 100 x 4.6mm 150 x 4.6mm 150 x 4.6mm 250 x 4.6mm 81178 81181 81188 88087 88092 — 81184 81191 88088 88093 Cyano 3µm 3µm 3µm 5µm 5µm 50 x 4.6mm 100 x 4.6mm 150 x 4.6mm 150 x 4.6mm 250 x 4.6mm 81179 81182 81189 88180 88189 — 81186 81192 88182 88191 3µm 3µm 3µm 5µm 5µm 50 x 4.6mm 100 x 4.6mm 150 x 4.6mm 150 x 4.6mm 250 x 4.6mm 81180 81183 81190 88205 88217 — 81187 81193 88207 88218 3µm 3µm 3µm 5µm 5µm 10µm 10µm 50 x 4.6mm 100 x 4.6mm 150 x 4.6mm 150 x 4.6mm 250 x 4.6mm 150 x 4.6mm 250 x 4.6mm 81414 81404 81409 88123 88171 88322 88327 — 81405 81410 88124 88172 88323 88328 PACKING C18 AQ New! PARTICLE SIZE 3µm 3µm 3µm 5µm 5µm 10µm 10µm PRICE PARTICLE SIZE LENGTH X ID INDUSTRY STANDARD PART NO. C18 5µm 5µm 150 x 4.6mm 250 x 4.6mm 88061 88062 Phenyl 5µm 5µm 150 x 4.6mm 250 x 4.6mm 88095 88096 Silica 5µm 5µm 150 x 4.6mm 250 x 4.6mm 88125 88173 PACKING Endfitting, SS, 1 set PRICE 28197 *Requires endfitting set (Part No. 28197). Alltima™ Prep Columns New! PARTICLE SIZE LENGTH X ID INDUSTRY STANDARD PART NO. C18 5µm 5µm 5µm 5µm 10µm 10µm 10µm 10µm 150 x 10mm 250 x 10mm 150 x 22mm 250 x 22mm 150 x 10mm 250 x 10mm 150 x 22mm 250 x 22mm 81102 88063 81106 81105 81107 88334 81108 88335 C8 5µm 5µm 5µm 5µm 10µm 10µm 10µm 10µm 150 x 10mm 250 x 10mm 150 x 22mm 250 x 22mm 150 x 10mm 250 x 10mm 150 x 22mm 250 x 22mm 81109 88081 81112 81110 81114 88336 81115 88337 Silica 5µm 5µm 5µm 5µm 10µm 10µm 10µm 10µm 150 x 10mm 250 x 10mm 150 x 22mm 250 x 22mm 150 x 10mm 250 x 10mm 150 x 22mm 250 x 22mm 81117 81116 81119 81118 81121 88338 81125 88339 PARTICLE SIZE LENGTH X ID PART NO. 3µm 3µm 33 x 7mm 53 x 7mm 50603 50605 3µm 53 x 7mm 50765 3µm 3µm 33 x 7mm 53 x 7mm 50607 50609 PACKING C8 C4-WP Amino Silica Alltima™ Rocket™ Columns PACKING C18 AQ C8 Contact your Alltech office or distributor for current or local prices. PRICE New! PRICE © Copyright 2001 Alltech Associates, Inc. 7 Alltima™ Guard Columns and Validation Kits Protect Your Alltima™ Columns with Alltima™ Guard Columns Alltima™ C18 Validation Kits Simplify Method Development • Simple – Fewer Parts, Fewer Seals, Fewer Problems • Fast – Change Cartridges in Seconds without Tools • Efficient – Matched Media and Low Dead Volume Maintain Chromatographic Performance When validating a method, Alltima™ is the column of choice because of its excellent batch to batch, and column to column reproducibility. The Alltima™ C18 Method Validation Kit helps test method ruggedness prior to routine use. This kit contains three columns made from three different batches of either 3µm or 5µm Alltima™ C18 packing. 1656 DESCRIPTION Alltima™ All-Guard™ Guard Columns DESCRIPTION PARTICLE SIZE LENGTH X ID QTY All-Guard™ Cartridges (Requires Guard Holder) C18 5µm 7.5 x 4.6mm 3 C18-WP 5µm 7.5 x 4.6mm 3 C18-LL 5µm 7.5 x 4.6mm 3 AQ 5µm 7.5 x 4.6mm 3 C8 5µm 7.5 x 4.6mm 3 C4-WP 5µm 7.5 x 4.6mm 3 Phenyl 5µm 7.5 x 4.6mm 3 Cyano 5µm 7.5 x 4.6mm 3 Amino 5µm 7.5 x 4.6mm 3 Silica 5µm 7.5 x 4.6mm 3 PART NO. Alltima™ C18 Validation Kits PRICE 96080 96412 96285 96344 96081 96413 96082 96084 96085 96083 PART NO. Alltima™ C18 Method Validation Kits 100 x 4.6mm, 3µm Kit (3 Columns from 3 Different Batches) 150 x 4.6mm, 5µm Kit (3 Columns from 3 Different Batches) 250 x 4.6mm, 5µm Kit (3 Columns from 3 Different Batches) PRICE 11350 11541 11543 Simplify Your HPLC Connections with Fittings and Accessories from Alltech Call to request brochure #441. Guard Holder (Includes Direct-Connect Column Coupler) All-Guard™ Cartridge Holder Ea 80101 Your Online Technical Resource for Chromatography The trademarks referred to herein are the property of their respective owners. Contact your Alltech office or distributor for current or local prices. Alltech Corporate Headquarters: 2051 Waukegan Road • Deerfield, IL 60015 Phone: 847-948-8600 • Fax: 847-948-0477 Email: [email protected] Web Site: http://www.alltechWEB.com Your Local Distributor is: 08/01 #458 © Copyright 2001 Alltech Associates, Inc. Alltech reserves the right to change prices and/or specifications without prior notification. Use of Our Products: Alltech Associates, Inc., supplies chromatographic equipment reagents and accessories for non-medical laboratory use only. This means our products: ... may NOT be used as drugs, ...may NOT be used as cosmetics, ...may NOT be used as medical devices or as in vitro diagnostic devices. ISO 9002 REGISTERED COMPANY QUALITY MANAGEMENT 015 Recycled Paper — part of the Alltech commitment to protect our valuable natural resources
© Copyright 2026 Paperzz