Environmental Housekeeping Handbook APPENDIX C HVAC background information ___________________________________________________________ Unitary vs. centralized HVAC systems Commercial buildings smaller than 20,000 square feet typically use factory-built, air-cooled “unitary” HVAC equipment. Buildings larger than 100,000 square feet and multi building campuses generally use siteassembled or engineered “centralized” HVAC systems. Buildings with a square footage between 20,000 and 100,000 square feet may employ a combination of multiple large packaged units (for example, one unit per wing of an office building) or small built-up systems. Performance comparisons between unitary and engineered systems, or among systems of either type, should consider the performance of the entire system, rather than just the chiller or the condensing unit. The principal advantages of central HVAC systems are higher energy efficiency, greater load-management potential, fewer and higher-quality components that require less (but more skilled) maintenance, and architectural and structural simplicity. The main advantages of unitary systems are lower initial costs, independent zone control, lower failure risk, and less floor space occupied by a mechanical room, ducts, and pipes. Performance measurements There are a number of metrics that can be used to compare the efficiency performance of various HVAC systems. The Air-Conditioning & Refrigeration Institute (ARI) defines standardized test procedures to determine the efficiency metrics for a limited scope of HVAC systems. The tests used to evaluate the performance vary based on the HVAC equipment being tested. The following list summarizes major HVAC performance metrics: Cooling capacity is rated as the amount of heat energy a cooling unit can remove from a space per hour, expressed in BTU per hour. Energy Efficiency Ratio (EER) is the ratio of the cooling capacity (BTU/h) to the power input value (watts) at any given set of rating conditions expressed in BTU/watt-hour. The current standard is an energy efficiency ratio (EER) of 8.9 for systems with a capacity of 65 to 135 thousand BTU per hour (kBTU/hr). Coefficient of Performance (COP) is defined differently depending on function. For cooling, COP describes the ratio of the rate of heat removal 109 to the rate of energy input in consistent units, for a complete cooling system as tested under a nationally recognized standard. For heating, it is the ratio of the rate of heat delivered to the rate of energy input in consistent units, for a complete heat pump system as tested under designated operation conditions. Conversion: COP = EER * 3.4. Note that both COP and EER are calculated under controlled laboratory conditions and usually do not reflect the efficiency of performance under actual use. The seasonal energy efficiency ratio (SEER) and the heating season performance factor (HSPF) address the need to reflect actual use by measuring efficiency in field situations. Seasonal Energy Efficiency Ratio (SEER) is the total heat removed from the conditioned space during the annual cooling season, expressed in BTU, divided by the total electrical energy consumed by the air conditioner or heat pump during the same season, expressed in watthours. U.S. federal appliance efficiency standards currently require minimum SEER ratings of 13. The highest efficiency models available can have SEER ratings up to 23 for central air units. Heating Season Performance Factor (HSPF) is the total heat added to the conditioned space during the annual heating season (expressed in BTU), divided by the total electrical energy consumed by the air conditioner or heat pump during the same season (expressed in watthours). Integrated Part-Load Value (IPLV) is a seasonal efficiency rating method for representative loads from 65,000 BTU per hour and up. This rating applies to units that have stated partial capacities, such as units with staged compressors. Units are tested at full capacity and at each stated partial capacity, and those values are then used to calculate IPLV. Additional information For additional information on HVAC design, see: Nontechnical introduction to HVAC: NCDEnr. 2003. “Energy Efficiency in industrial HVAC systems.” accessible at: http://www.p2pays.org/ref/26/25985.pdf Technical discussion of HVAC systems: Benjamin, Reynolds, Grondzic, and Kwok. Mechanical and Electrical Equipment for Buildings, 10th Edition. John Wiley & sons, inc. new York. Notes 1 American Council for an Energy Efficient Economy (ACEEE). 2004. Online guide to Energy-Efficient Equipment. High-performing HVAC systems. accessible at: http://www.aceee.org/ogeece/ch3_index.htm. 110 Environmental Housekeeping Handbook 2 ERPI Office Complexes Guidebook, Innovative Electric Solutions. Chapter 6—Heating, Ventilating, and Air-Conditioning (HVAC). December 1997. tr-109450, p. 195. 3 Air-Conditioning and Refrigeration Institute. (2006). 2006 Standard for Performance Rating of Unitary Air-Conditioning Equipment and Air Source Heat Equipment. 111
© Copyright 2026 Paperzz