B1 | arris1

B1
24
| arris1
integrations
w w w.al i ghts .c om
a·light
B1
| arris1
project
type
quantity
Optics
dust cover | asymmetric
suspended
dust cover | symmetric
Additional Integrations Selections
Lengths:
custom mounting
non-standard nominal individual lengths: 5', 6', 7', 9', 10', 11'
precise lengths
nominal rows longer than 24'
partial span mount
exact lengths to the nearest 100th of an inch
patterns
╔╔ c ustom angles
Optons:
╔╔ precise lengths
custom finish
╔╔ wall-to-wall specification
Design-Assist:
╔╔ tig-welded corners, sanded smooth to eliminate light leaks
in-house design-assist team manages your unique project
╔╔ f ully lit corners with mitered lenses
Mounting:
single cable
╔╔ seamless transitions between sections and various mounting types
pendant stem
╔╔ LED recommended for patterns
+
Cross Sections
Multiple configurations available - sampling shown
dust cover
LED
2”
dust cover
open
T5
T5
symmetric
open
dust cover
T5
symmetric
T5
asymmetric
asymmetric
2-3/4”
symmetric
Available Light Platforms
LED
integrations
T5
Available Mounting
controls
friendly
single cable
w w w.al i ghts .c om
pendant stem
partial span
25
B1
| arris1
integrations
Linear Dimensions:
Standard lengths available are located on the 'elements' spec sheet. All
other lengths should be specified as follows...
Partial Span. Fixture spans from wall or other object, terminating mid-room via
suspension cable. Utilizes standard powercord or endfeed. Wall
termination features sit-in powerfeed bracket at wall end of fixture.
Additional center suspension cables required for support if longer than 16’.
Individual fixtures, as a single length extrusion longer than 12’ up to 16’,
require special-order housings. Consult factory with architecture details submittals required.
Nominal Row
R___: Specify in nominal feet.
Choose when nominal length is acceptable.
Actual length will be shorter or longer due to metric lamp lengths. Lengths
over 12' are comprised of multiple sections.
Finish:
Electrostatically applied powder coat finish.
Examples: a nominal 54ft row begins as B1R54; a 7ft individual as B1R7.
Exact Row
M___: Specify overall length in inches to the nearest hundredth.
Choose when exact lengths are required as determined by space
constraints, etc.
Submittals required. Lengths over 12' are comprised of multiple sections.
Construction:
60% recycled aluminum extruded housing. Precision milled endcaps.
Listing:
UL/CUL. Damp Location.
Examples: an exact 54ft row begins as B1M648.00; a 7ft individual as
B1M84.00.
Companion Luminaires:
B4 wall.
Pattern Dimensions:
Each pattern contains a precision-formed optical platform engineered for
maximum light output and even distribution.
Pattern
P___x___: Specify overall length of each section in inches to the nearest
hundredth.
Choose when multiple angles are necessary. Submittals required: contact
our design-assist team and submit architectural drawings with precise
lengths and angles required.
Examples: an exact 54ft section angling into a 7ft section begins as
B1P648.00x84.00. Continue with another "x___" for subsequent sections.
Lamping:
LED. 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See
wattage/lumen table for specifications per foot. All
specifications are subject to change.
LED
T5/T5HO. Single lamp in cross section. Low-profile electronic, high
power factor, program start, sound rating A, inherent thermal
protection, UL listed Class P, <10% THD. Dimming: specify
T5
manufacturer/model.
Mounting:
Single Cable. (1) 4’, 1mm stainless steel aircraft cable w/ fully
adjustable grippers and locking device. 5’ plastic-coated,
silver-braided, flexible cord. Satin white, square canopy is
standard.
Pendant Stem. 3/8” stem and round canopy, painted white. Indicate
pendant length. If specified for earthquake zone, a∙light will
provide swivel canopies.
Legend:
26
1.
Emergency ballast not applicable on lengths 3ft or less.
2.
Multi-circuiting: submit multi-circuiting requirements during submittal process.
3.
Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter.
4.
Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight
harvesting. Requires 0-10V dimming ballast.
w w w.al i ghts .c om
a·light
B1
| arris1
project
type
quantity
interior
Series:
B1
LED
per foot
LS
LH
suspended
Dimension:
for standard lengths available: see 'elements' specification sheet
R___
damp location nominal length (specify length in feet)
exact length (specify length in inches to the nearest 100th)
M___
pattern (specify length in inches to the nearest 100th)
P_x_
Lamping:
LED standard output symmetric distribution
LS
LED high output symmetric distribution
LH
LED standard output asymmetric distribution
LAS
LED high output asymmetric distribution
LAH
T5 (1) symmetric distribution
S
T5HO (1) symmetric distribution
H
T5 (1) asymmetric distribution
SA
T5HO (1) asymmetric distribution
HA
LED Temp (if applicable):
3000k
30
3500k
35
4000k
40
Voltage:
universal 120V - 277V
U
120V
1
277V
2
347V
3
Optics:
open/no lens
O
clear dust cover
D
custom
C
Mounting:
single aircraft cable
S
pendant / rigid stem - indicate stem length
P__
pendant / rigid stem for earthquake zone - indicate stem length
PV__
partial span single cable
JS
custom
C
Finish:
a∙lightanium™
T
satin white
W
satin black
B
textured eggshell white
E
other - specify RAL#
O
custom
C
Options:
dimming - specify manufacturer, model/series and voltage
D
emergency (fluorescent only) - specify model/series or lumens 1 E
external fusing
F
multi-circuit 2 M
new york city code
N
occupancy sensor 3 O
photocell/daylight sensor 4 P
1 board in cross
watts/ft
lumens/ft
5
600
10
1200
Lumens at board at 4000k.
Consult IES files online for delivered lumens.
Specifications subject to change.
integrations
w w w.al i ghts .c om
Version | March 2014
27