Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008 Prepared For The Lighting Quotient Paul Ford 114 Boston Post Road West Haven,CT 06516 United States Catalog Number S143-M027-S-02-M-L0-0-2H-TE Order Number 11130099 Test Number 1199532 Test Date 2016-01-28 - 2016-03-04 Prepared By Approved By Javier Caban, Technician Kyle Spaziani, Project Handler The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Test Number 1199532 - Page 1 of 8 Table of Contents Summary of Results Page 3 Integrating Sphere Results Page 4 Distribution Results Page 5 Conditions / Summary of Results / Polar Plot / Zonal / Luminance Page 5 Candela Tabulation Page 6 Coefficients of Utilization Page 7 In-Situ Results Page 8 #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! Laboratory results may not be representative of field performance Ballast factors have not been applied Testing was performed in a 2-meter integrating sphere using the 4π geometry method. Absorption correction was employed for Sphere measurement Test Number 1199532 - Page 2 of 8 Luminaire Description: Lamp: Mounting: Ballast/Driver: White aluminum housing, frosted plastic lens 27 white LEDs Surface One GE/LighTech GELD36DMV700PU and one GE/LighTech GELD18DMV700PU Luminaire Luminaire Characteristics Luminous Length: Luminous Width: Luminous Height: 2.75 in. 20.75 in. 2.25 in. Summary of Results Integrating Sphere Luminous Flux: Efficacy: CCT: CRI (Ra): Distribution 2609 Lumens 43.1 lm/w 2723 K 96.4 Total Luminaire Output: Luminaire Efficacy: Maximum Candela: Electrical Data at 277 VAC Test Temperature: Voltage: Current: Power: Power Factor: Frequency: Current THD: 25.1 277.0 0.2377 62.01 0.941 60 10.8 °C VAC A W Hz % 2637 Lumens 43.3 lm/w 1973 Candela In-Situ LED Temperature: Driver Temperature: Measured LED Current: 98.4 °C 75.0 °C 0.6842 A Temperature is offset to an ambient temperature of 25°C as described in UL1598-2008. Test Number 1199532 - Page 3 of 8 Color Quality - Integrating Sphere Integrating Sphere Test Conditions Temperature 25.8 °C Voltage 120.0 VAC Current 0.5068 A Power 60.52 W Power Factor 0.995 Frequency 60 Hz Current THD 9.95 % Summary of Results Total Output: Efficacy: CCT: CRI (Ra): CRI (R9): Chromaticity (x): Chromaticity (y): Chromaticity (u): Chromaticity (v): Chromaticity (u'): Chromaticity (v'): Duv: 2609 Lumens 43.1 lm/w 2723 K 96.4 78.1 0.4551 0.4052 0.2619 0.3497 0.2619 0.5246 -0.0019 Insert Chromaticity Diagram Color Rendering Index Detail Ra (CRI) R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 96.4 98.1 99.5 98.8 96.8 97.5 97.0 93.9 89.4 78.1 97.6 97.7 87.0 99.1 98.4 Flux vs Wavelength 70.00 Spectral Flux (mW/nm) 60.00 50.00 40.00 30.00 20.00 10.00 0.00 350 400 450 500 550 600 650 Wavelength (nm) Test Number 1199532 - Page 4 of 8 700 750 800 850 Distribution - Goniophotometer Distribution Test Conditions Temperature 24.2 °C Voltage 120.0 VAC Current 0.5097 A Power 60.84 W Power Factor 0.995 Frequency 60 Hz Current THD 9.96 % Summary of Results Spacing Criteria 0-180: 2.90 90-270: 0.65 Total Lumen Output: Luminaire Efficacy: Maximum Candela: 2637 Lumens 43.3 lm/w 1973 Candela Polar Plot 120 135 150 165 165 150 135 120 105 105 500 90 1000 1500 90 75 60 75 45 60 30 15 0 15 180 Deg. Plane 270 Deg. Plane 30 45 0 Deg. Plane 90 Deg. Plane Zonal Lumen Summary Zone 0-5 5-10 10-15 15-20 20-25 25-30 30-35 35-40 40-45 45-50 50-55 55-60 Lumens 6.1 19.6 41.1 82.2 137.7 186.4 209.6 217.3 220.1 219.3 204.1 177.3 % of Luminaire 0.2% 0.7% 1.6% 3.1% 5.2% 7.1% 7.9% 8.2% 8.3% 8.3% 7.7% 6.7% Zone 60-65 65-70 70-75 75-80 80-85 85-90 90-95 95-100 100-105 105-110 110-115 115-120 Lumens 152.5 134.5 121.8 113.1 104.6 84.2 60.6 45.9 34.3 23.2 14.7 9.3 % of Luminaire 5.8% 5.1% 4.6% 4.3% 4.0% 3.2% 2.3% 1.7% 1.3% 0.9% 0.6% 0.4% Zone 0-40 0-60 0-90 90-180 Lumens 900 1721 2432 205 % of Luminaire 34.1% 65.3% 92.2% 7.8% Test Number 1199532 - Page 5 of 8 Zone 120-125 125-130 130-135 135-140 140-145 145-150 150-155 155-160 160-165 165-170 170-175 175-180 Lumens 6.0 4.0 2.7 1.9 1.3 0.8 0.4 0.2 0.1 0.0 0 0 % of Luminaire 0.2% 0.2% 0.1% 0.1% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% Candela Tabulation 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 250 324 518 1095 1728 1951 1613 1218 1004 855 754 687 635 581 538 535 564 504 376 296 239 181 129 89 60 42 30 23 17 13 9 6 3 2 0 0 0 250 316 473 941 1593 1949 1806 1348 1079 900 779 698 642 589 541 525 551 502 368 288 235 173 119 79 52 36 26 20 15 11 8 5 3 1 0 0 0 250 294 374 559 982 1528 1895 1882 1474 1100 873 718 619 547 495 450 439 427 311 226 176 128 81 50 33 22 16 12 9 7 4 3 1 0 0 0 0 250 271 299 339 399 507 705 1005 1371 1656 1645 1284 868 585 423 324 256 215 168 103 63 39 22 13 9 6 5 3 2 2 1 0 0 0 0 0 0 250 253 253 252 251 249 247 243 239 234 229 225 223 224 223 187 99 22 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 232 218 205 193 180 167 153 139 122 104 84 63 42 23 10 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 220 198 179 161 144 126 109 89 69 52 34 20 11 5 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 214 188 165 143 123 102 79 58 39 24 15 8 4 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 211 184 160 137 116 93 68 49 31 19 12 7 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 214 188 165 143 123 102 79 58 39 24 15 8 4 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 220 198 179 161 144 126 109 89 69 52 34 20 11 5 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 232 218 205 193 180 167 153 139 122 104 84 63 42 23 10 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 253 253 252 251 249 247 243 239 234 229 225 223 224 223 187 99 22 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 250 271 299 339 399 507 705 1005 1371 1656 1645 1284 868 585 423 324 256 215 168 103 63 39 22 13 9 6 5 3 2 2 1 0 0 0 0 0 0 250 294 374 559 982 1528 1895 1882 1474 1100 873 718 619 547 495 450 439 427 311 226 176 128 81 50 33 22 16 12 9 7 4 3 1 0 0 0 0 250 316 473 941 1593 1949 1806 1348 1079 900 779 698 642 589 541 525 551 502 368 288 235 173 119 79 52 36 26 20 15 11 8 5 3 1 0 0 0 2 Average Luminance (cd/m ) Vertical Angle (Degrees) Vertical Angle (Degrees) Horizontal Angle (Degrees) 0 45 55 65 75 85 Horizontal Angle (Degrees) 0 45 6784 6784 18070 25520 15010 17570 13560 14630 13840 13710 15160 15690 Test Number 1199532 - Page 6 of 8 90 6784 8112 9230 11690 13990 3028 Utilization of Lumens - Zonal Cavity Method Effective Floor Cavity Reflectance 20% Ceiling Cavity Reflectance Wall Reflectance 80 70 50 70 30 10 70 Room Cavity Ratio (RCR) 0 1 2 3 4 5 6 7 8 9 10 50 50 30 10 50 30 30 10 50 30 10 0 10 50 30 10 0 2652 2059 1663 1371 1151 980 844 734 645 570 508 2502 2091 1797 1566 1381 1230 1104 998 908 831 764 2502 2024 1690 1434 1234 1075 945 837 748 673 609 2502 1961 1595 1322 1113 950 820 715 628 557 496 2432 1888 1522 1251 1045 885 758 656 573 504 447 ** Values are expressed as Lumens delivered to the task surface ** 3090 2750 2475 2240 2038 1864 1711 1578 1461 1358 1266 3090 2595 2226 1932 1694 1499 1337 1201 1085 987 902 3090 2456 2020 1693 1443 1245 1086 956 849 759 684 3090 2331 1846 1503 1250 1057 906 785 687 606 539 2995 2653 2383 2153 1958 1791 1645 1518 1406 1308 1221 2995 2513 2157 1873 1644 1457 1300 1169 1058 962 880 2995 2387 1968 1653 1411 1219 1065 938 834 746 673 2995 2273 1808 1476 1230 1041 893 775 678 599 533 2816 2361 2027 1763 1550 1376 1230 1108 1005 916 839 2816 2257 1870 1576 1349 1169 1023 904 804 721 651 2816 2162 1734 1423 1190 1010 868 754 661 585 520 Cone of Light Tabulation Mounting Height 4.00 6.00 8.00 10.0 12.0 14.0 16.0 Footcandles at Nadir 15.6 6.94 3.90 2.50 1.73 1.27 0.976 Diameter (Feet) 9.84 14.8 19.7 24.6 29.5 34.4 39.4 Cone of Light Plot Test Number 1199532 - Page 7 of 8 2652 2220 1908 1660 1462 1300 1165 1051 955 872 801 2652 2136 1777 1503 1290 1121 983 870 776 697 629
© Copyright 2026 Paperzz