NEUTRAL SALT SPRAY TEST REPORT FOR CT-GMSG-500

NEUTRAL SALT SPRAY
TEST REPORT FOR CT-GMSG-500
1. TEST PERFORMED
Neutral Salt Spray to ASTM B117 performed on parts provided to meet the performance
requirements as specified by customer. Test conditions were as specified in ASTM B117, and no
deviations were noted. Test results only relate to the specific parts tested and the extrapolation of
these test results to other parts is outside the scope this test as provided.
2. PART DESCRIPTION
Part Description:
GalMax 69 Silver Galvanizing Aerosol Spray
Part Identification:
CT-GMSG-500
3. TEST RESULTS
Internal Sample No:
S-160186
Date Received:
18th November 2016
Test Duration:
168 hours
Test Commenced:
22nd November 2016 @ 7:45am
Test Completed:
29th November 2016 @ 7:45am
Additional Test Notes:
As per customers request, 3 coats were sprayed, 1 hour dry time
before recoating. Bottom of panel is not part of the test as no tape
was applied.
Original report available upon request.
Page 1 of 3
4. TEST RESULTS CONTINUED
Test:
Three Steel Hull Cell panels were stripped cleaned and dried. These
were then spray coated in accordance with the supplier’s
instructions. Three coats were applied in all. The edges and rear
were masked in tape, apart from the bottom edge. The panels were
subjected to 168 hours of neutral salt spray inclined at 6o from
vertical.
Observations:
After 168 hours in the Neutral Salt Spray chamber, of the three
panels tested, one panel had one red corrosion spot. No other
corrosion was found on the three panels.
Concluding Remarks:
It is likely the corrosion spot has formed from an air bubble in the
spray coating. Overall there was insignificant red corrosion found. It
also should be noted that the bottom of the panels were not taped
to allow the salt spray solution to run freely down the panel and not
cause ‘pooling’ on the panel. The bottom edge of the panel is not
reported on and is not part of the test as bare steel was still
showing. See attached photos.
5. AUTHORISATION
Report Number:
S-160186 Issue 1 Amendment 0
Lead Analyst:
Shane McInnes – Laboratory Manager
Original report available upon request.
Page 2 of 3
- END OF REPORT -