THE CELLULAR BEAM POCKET GUIDE ENTRUSTED TO DESIGN AND DELIVER METAL SOLUTIONS Cellular Beams Kloeckner Metals UK Westok pioneered the use of cellular beams in the UK, and is the inventor and patent holder of the Westok Cellular Beam and the Ultra Shallow Floor Beam® (USFB), a unique and innovative range of floor and roof beams. We also manufacture solid web and cellular plated beams - the Westok Plate Beam (WPB). We are a specialist steelwork fabricator and designer who drives economy into the design of steel framed structures by providing an unrivalled range of cellular, shallow and plated beam solutions and software packages. Over the past twenty five years, we have established an impressive track record of delivery across a diverse range of sectors in the UK, Ireland and further afield. Our team of structural engineers can assist at any stage of the design process. Kloeckner Metals UK Westok engineers can call upon many years’ experience to offer free and impartial advise. Our engineers can provide calculations, assist with the analysis and design of the steel frame, facilitate design workshops, attend design team meetings, visit site and assist with BIM co-ordination. We also offer free CPD Seminars. To use any of these services, contact your local Technical Advisory Engineer. Free analysis, design and BIM software is available from www.kloecknerwestok.com. John Callanan BA BAI MSc. CEng MIEI MIStructE Design Team Leader [email protected] Tel: +44 (0)113 205 5270 Mob: +44 (0)7920 500 413 Walter Swann Gl BEng CEng MIStructE Ed Technical Advisory Engineer [email protected] Mob: +44 (0)7734 985 140 Martin Baugh Mi Bel BSc CEng FICE FIStructE Li Ma Technical Advisory Engineer Hu Le [email protected] Mob: +44 (0)7554 334 751 Sh Du Gal Lim Kevin Small Bi Technical Advisory Engineer [email protected] Co Ca Ox Br Lo Tel: +44 (0)113 205 5270 James Way BEng CEng MICE Technical Advisory Engineer [email protected] Mob: +44 (0)7786 701 452 Care has been taken to ensure to the best of our knowledge that all data and information contained herein is accurate to the extent that it relates to either matters of fact or accepted practice or matters of opinion at the time of publication. However, Kloeckner Metals UK Westok, the authors and reviewers assume no responsibility for any errors in or misinterpretations of such data and/or information or any loss or damage arising from or related to its use. 2 www.kloecknerwestok.com CONTENTS 4 Westok cellular beams What is a Westok cellular beam? | How are they manufactured? | Asymmetric sections | Ribbon cuts | Workmanship 6 Applications Floor beams | Roof beams | Westok Curves | Tapered beams 12Specification How to specify Westok beams | Simple specification for standard Westok beams | Tabular specification for more complex designs 14Detailing Setting out the cells | Value Engineering - detailing out infills | Primary beams and spine beams | Optimising cell pitch 16Connections Simple connections | Splices 17 Economic design of Westok beams 18Understanding cellular beams Vertical shear | Horizontal shear | Vierendeel bending | Web-post buckling 19Fire Fire protection | Fire engineering with cellular beams 20 USFBs - Ultra Shallow Floor Beams 21 WPBs - Westok Plate Beams 21 What product where? 22Software Integration with 3rd party software 24 Quick Sizing Guide 27 References www.kloecknerwestok.com 3 Westok cellular beams What is a Westok cellular beam? It is a modern version of the traditional “castellated beam”, but far more flexible and with a greater range and depth of applications. Flexible Fl Flexible ex ib l e Figure 1. How are they manufactured? A steel Universal Beam (UB) or Universal Column (UC) is expanded using a unique two pass cutting process that results in a beam approximately 40 - 60% deeper than the parent section from which it was made. The exact finished depth is a function of both the cell diameter and cell spacing, and all three are highly flexible. Available in increments of 1mm to optimise. The resulting Westok cellular beam has, approximately, a 50% greater section modulus/load carrying capacity and a 125% increase in inertia/stiffness relative to the original parent section properties, but, with no increase in weight. Asymmetric sections When a section is split using the Westok process two identical tees are created. A further layer of flexibility can be added by combining top and bottom tees from different parent sections to create an asymmetric section. As tees are created in pairs, for efficient use of material asymmetric sections should be designed in pairs too. Asymmetric sections can be used in composite floor construction to produce very light highly design efficient beams, but they can also be useful where there is instability of the compression flange, for instance in spine beams on single storey buildings. Asymmetric cellular beam for composite applications Asymmetric cellular spine beam Design asymmetric sections in “pairs” for efficient use of material 4 www.kloecknerwestok.com Westok cellular beams Ribbon cuts In the splitting process used to create a Westok beam, the two cuts are separated by 10mm, and produce two identical tee sections. This separation distance is required for manufacturing purposes. The cut is a repeat pattern producing multiple cells at regular spacings throughout the beam, perfect for accommodating both current and future servicing requirements in modern commercial buildings. The “default” ribbon cut with 10mm separation It’s a simple matter to separate the two cuts further, to create identical tees of a prescribed depth. Where depth and servicing provision are critical, this allows beams to be designed and manufactured to an exact depth and with a fixed vertical dimension to the centre of the cells. This is sometimes referred to as a ‘ribbon cut’ as a ribbon of material is left behind. Bespoke ribbon cut with increased separation to create designer depth beams Workmanship Full penetration butt welds are used at each web-post when assembling the Westok beams. All workmanship is to BS EN 1090 and carried out to EXC 2 as standard. Westok are certified to EXC 4, and so can manufacture to more rigorous standards if required. Terminology Cell Pitch Web Post Ce l lD ia m et er Top Tee Bottom Tee Note: in asymmetric sections the top and bottom tee depths may be different, therefore the centre line of the cell may not be at the mid-depth of the section. www.kloecknerwestok.com 5 Applications Floor beams The major use of cellular beams is as simply supported secondary floor beams to achieve either clear open spans and/or service integration. Also, where a deeper beam is permitted a Westok will be more economical than a heavy UB section. Increasing economy Services requirement < 9m span < 12m span > 12m span USFB 3 33 Single service opening 3 33 333 Normal/heavy services 33 333 333 No services USFB = Westok Ultra Shallow Floor Beam Clear span secondary, short span primary Choosing the most appropriate grid layout is key to efficient and economic design. The optimum floor layout uses Westok beams as clear span secondaries; the primary member can be a plain UB, a Westok cellular beam or a Westok plate beam. CLEAR SPAN SECONDARY LAYOUT 3 CLEAR SPAN PRIMARY LAYOUT Westok beam UB UB UB UB UB UB Westok beam Westok beam UB / Westok* UB / Westok* Westok beam 7 Westok beam * Dependent on services, load and grid dimensions As well as being a better technical solution, the clear span secondary layout offers: • More options, either - Shallow construction – beams with a span/d ratio as high as 35 possible - Deeper beams with large openings for services – typical span/d of 20 - Anything in between! • Lower piece count therefore quicker fabrication and erection • Improved footfall response • More favourable A/V ratios for fire protection resulting in lower coating thicknesses and fewer coats 6 www.kloecknerwestok.com Increasing economy SPAN REQUIREMENT Applications Deflections Deflections of long span beams can often require the specification of costly pre-cambers. Westok beams are pre-cambered as part of the manufacturing process without additional cost, unlike UBs and plate beams. Precambers up to 50mm are free of charge. Increasing economy Cambers are generally chosen to offset the deflection due to the self-weight of the composite slab and steelwork, however they should also be sufficiently pronounced so that they can easily be identified in the steelwork contractors workshop and also on site. As a guide cambers should be no less than 10mm or span/1000, whichever is the greater. There is often concern about whether cambers will “drop out”. Selecting a suitable value is something of an art, and when choosing, consideration should be given to the stiffness of the frame, type of connections and proximity to any stiff cores etc. SCI P300 (pg 59) offers the following guidance “ … a general rule of thumb is to design any pre-cambering to eliminate no more than two thirds of the dead load deflection”. Accuracy of pre-cambers Cambers in Westok beams are “built in” as part of the assembly and manufacturing process. Consequently the accuracy of the cambers far exceeds the requirements of the National Structural Steelwork Specification (NSSS). Please consult Westok with project specific requirements. Cast to level or cast to thickness? Levelling of composite floors is carried out in one of three ways:1)Tamping rails or levelling pins, supported on the beams acting as a datum, are set to the intended structural floor level. 2)Tamping rails or levelling pins, supported on the beams acting as a datum, are set to achieve a constant thickness of concrete relative to the top of the beams. 3)Rigid columns are used as datum points for laser levelling. Levelling equipment is then used to produce a level upper concrete surface, irrespective of the deflection of the supporting steelwork or of the specified thickness of the concrete being laid – a technique known as “flood pour”. The relative merits of each method is discussed in SCI Advisory Desk Note AD 344. If significant cambers are being specified, method 2 (cast to thickness) will ensure that the nominal slab thickness required by design at mid-span is achieved on site. www.kloecknerwestok.com 7 Applications Ponding Westok beams are easily pre-cambered to counteract the effect of self-weight deflection of composite slab and beam. If the composite deck deflection exceeds prescribed limits at construction stage however, then an allowance in the loads should be made for “ponding”. SCI publication P300 offers the following advice “… if the central deflection of the sheeting d is greater than 1/10 of the slab thickness, ponding should be allowed for. In this situation the nominal thickness of the concrete over the complete span may be assumed to be increased by 0.7d”. Using this guidance for a 3m span slab of 150mm overall depth, if the construction stage deflection exceeds span/200 then ponding should be allowed for in the design. Most decking software automatically allows for this in the design of the metal deck, however, ponding effects are not allowed for in the Cellbeam software and need to be user defined where appropriate. Footfall Response of Clear Span Floors Client specifications often include a performance requirement for floors in the form of a maximum permitted response factor - low response factors indicating better performance. Clear span floors have higher modal mass than short span solutions, often double, and so easily meet the criteria for general office floors of 8. SCI publication P354 offers advice on appropriate acceptance criteria and presents a simplified hand calculation method, the basis of our freely available vibration analysis package Cellvibe, as well as advice on more rigorous FE modelling. When considering response characteristics of a floor plate it is worth noting that: 1)A clear span secondary arrangement will outperform a clear span primary arrangement. 2)Longer spans will outperform shorter spans 3)Normal weight concrete will outperform lightweight concrete. 4)A re-entrant deck will provide an improvement of approximately 1 in the response factor relative to a trapezoidal profile - on account of the increased mass. 5)An increase in concrete depth of 10mm, irrespective of the decking profile used, will see an improvement of approximately 1 in the response factor. Typical response factors for clear span floors are given in the quick sizing guide of this booklet. 8 www.kloecknerwestok.com Applications Roof beams The perfect application for a Westok cellular beam in a roof application is as a simply supported rafter. At spans of approximately 20m or more a cellular rafter will be lighter than a plain UB section and cheaper to fabricate than a truss. If a curved section is required the cost savings are compounded compared to a curved plain UB. SPAN REQUIREMENT Rafter type < 20m 20 – 40m > 40m Straight simply supported 33 333 333 Curved simply supported 333 333 333 A plastically designed portal frame is a very efficient structural form. Unfortunately cellular beams are not suitable for plastic analysis, but they can often offer cost and weight savings at larger spans when elastic design is more appropriate. Where curved rafters are required the in-house curving capability at Kloeckner Westok allows cost and material savings to be made. SPAN REQUIREMENT Frame type < 20m 20 – 40m > 40m Pitched portal 8 3 33 Curved portal 3 33 333 Portal Frame or Braced Box? Although extremely efficient, portal frames have one or two disadvantages. Stanchions can become relatively large, particularly for larger spans, and compromise the spatial requirements of the client. Also, haunches can become deep adding height and cost to the building. The uplift in frame weight and cost of a “braced box” approach utilising roof and wall bracing is often relatively modest. It permits the use of slender columns, maximising usable floor space, minimising building height and so reducing the area of cladding required providing savings in total build cost. www.kloecknerwestok.com 9 Applications Westok Curves Many cellular beams can be curved “in house” at little or no cost, providing significant cost savings compared to curved plain beams. However, for certain tight curves and for Westok beams manufactured from 610 UBs and above or 356 x 368 UCs and above, Westok work with a specialist section bending company. It’s best to contact Westok to discuss the curving requirements on any particular project, but the rules of thumb below give an indication of what’s possible for curving about the major axis. Minimum radius for an “in-house” Westok curve: 30 – 80m dependant on bar length (for all sections up to and including a 533 x 210 UB and 305 x 305 UC). Minimum radius for a curve in collaboration with a section bending company, 35 times the beam depth. Tapered cellular beams Cellular beams provide the most economical method to create tapered steel members. Profile at the angle of required taper Spin one tee 180° and re-weld Tapered beams can have cells of uniform diameter, cells of varying diameter, or no cells. This affects the relative cost. MINIMUM COST MEDIUM COST HIGHEST COST 10 Uniform diameter cells full length - provides the most efficient design, combined with the minimum amount of weld length. Bespoke cells that vary in diameter - also minimises weld length but the design is likely to be slightly heavier. No cells - The beam is not expanded so is heavier than a cellular taper. It also requires a long length of weld, and so there is difficulty in maintain straightness due to the heat input necessary. www.kloecknerwestok.com Applications Cantilever Roof Members Cellular beams are frequently the preferred choice for cantilevers, providing great depth and therefore huge inertia at the support and minimum depth and therefore minimal weight at the tip. Long cantilevers are often designed using two or even three different beam sizes to minimise the overall weight of the rafter. 15m 13m 762 x 267 x 173kg/m 457 x 191 x 74kg/m Cantilever compound taper used at Carlisle United FC A Different Approach to Pitched Roofs Where column depths need to be minimised or where eaves height is critical the traditional haunched portal frame can compromise a client’s spacial requirements. A tapered cellular beam solution, as shown below, as part of a braced frame can provide a different approach, reducing the height at the eaves and allowing the use of slender columns maximising useable floor area and minimising envelope cost. A tapered beam minimises the height to the underside of the eaves. www.kloecknerwestok.com The deepest point of a tapered rafter is at mid-span where the maximum inertia is required 11 Specification How to specify Westok beams There are seven pieces of information required to tie down the specification of any Westok beam. They are: 1. The overall depth 2. The top tee section size 3. The top tee depth (for ribbon cuts) 4. The bottom tee section size 5. The cell diameter 6. The cell pitch or spacing 7. The distance to the first cell from a setting out point Simple specification for standard Westok beams Symmetric Westok beams designed and manufactured using the standard cut can be called off on plan using a simple line specification as shown below. overall depth mass/m cell diameter WESTOK 796 X 210 X 82 CB (575/725) Serial width of top and bottom tees “CB” denotes cellular beam cell pitch If the distance to the first cell relative to an appropriate grid is indicated on the drawings, then this together with any cambering requirements gives all the information required for manufacture. Asymmetric sections can be called off in a similar way, see below. In this case the asymmetric section comprises a 457 x 152 UB 60 top tee and a 533 x 210 UB 101. The average mass/m of the cellular beam is (60+101)/2=80.5 kg/m and is quoted in the specification. “ACB” denotes asymmetric cellular beam WESTOK 674 X 152/210 X 80.5 ACB (450/695) Serial width of top tee mass/m of cellular beam Serial width of bottom tee 12 www.kloecknerwestok.com Specification Tabular specification for more complex designs Where the design requires the use of “ribbon cuts” or more comprehensive information needs to be communicated, such as cambers or stud data, a tabular approach to specification can be helpful. Data to assist fire applicators can easily be accommodated in a table too. The “Add-To-Table” function in the Cellbeam software automatically produces an Excel spreadsheet populated with all of the necessary information to make specification simple and straightforward. Beam Mark CB1 ACB1 Overall Depth TEE DETAILS (mm) Section Mass Grade kg/m TOP 533 x 210 UB 82 S355 BOT 533 x 210 UB 82 S355 TOP 457 x 152 UB 60 S355 BOT 533 x 210 UB 101 S355 796 574 Top Tee (mm) Factored CELL DATA Depth Dia Reaction Pitch Dist to 1st Relative (mm) (mm) cell (mm) to grid Camber (kN) (mm) 82 398 575 725 638 A 95 50 80.5 317 450 695 638 5 205 25 SHEAR CONNECTORS 19mm dia 95mm LAW N/A 1 stud every trough Availability “Populars” are those steel sections up to and including a 610 x 229 UB 140 and 305 x 305 UC 283. They roll at the mills very frequently, often on a 4 week cycle, and are widely available from stock. “Heavies” are all of the deeper and heavier sections above. They tend to roll less frequently, usually a 6 to 8 week cycle, and whilst still readily available are less widely stocked and come at a cost premium compared to populars. The standard grade for both populars and heavies is S355J0. Westok cellular beams are always made from stock sections, and so can be manufactured and delivered very quickly. CE Marking Westok manufacture cellular beams in accordance with the National Structural Steelwork Specification (NSSS) as standard. This covers EXC2 (Execution Class 2) requirements to BS EN-1090, which is adequate for most building structures. However, certification is held for EXC4, so projects with more demanding requirements such as stadia or nuclear work can also be catered for. Testing Weld testing is carried out in accordance with the frequency and requirements of BS EN 1090, but more stringent project specific testing is available. www.kloecknerwestok.com 13 Detailing Setting out the cells Cellular beams are often chosen for service integration, so it’s crucial that appropriate attention is given to cell setting out to ensure that cells are aligned to allow the passage of services. Vertical alignment of the cells relative to the top flange of the beam is controlled by the specification of the top tee depth, which is a function of the serial size and any ribbon cut requirements. Horizontal alignment is controlled by specifying the distance to the first cell on all beams, relative to a setting out point, commonly a grid line. Value engineering – detailing out infills Structural infills are those required as part of the design of the Westok beam, and with appropriate application of the product and careful application, they are easily designed out/minimised. Non-structural infills are those needed to facilitate a connection. With careful detailing they can often be eliminated altogether, and a useful rule of thumb is to ensure there is no more than one infill per beam. In a serviced floor the best approach is to optimise the cell pitch so that no infills are required for the beams on grid. This cell layout is also used for the intermediate beams, and ensures horizontal alignment of cells. This approach limits the infills to two half infills on each of the intermediate beams as shown in the diagram, or the fabricator can eliminate infills altogether by using extended fin plate connections between the primary and secondary beams. CB1 (full web post) CB1 CB2 CB2 (½ infill) CB2 CB1 Note: the ½ infills could be eliminated with use of extended fin plates The optimum cell pitch for the beams on grid (CB1) can be found using the formula below. 14 www.kloecknerwestok.com Detailing Primary beams and spine beams The cell pitch for a primary beam or spine beam should be chosen such that it is a multiple of the beam spacing. This, combined with a reasonably proportioned web-post should allow connections to be made without the need to infill cells. In addition valley/spine beams in single storey buildings can be “set up” into the purlin zone and proportioned to accommodate the incoming rafter, simplifying fabrication and erection and driving out cost. Simple connection into a cellular valley beam Costly dropped haunch beneath a plain valley beam www.kloecknerwestok.com 15 Connections Simple shear connections Simple shear connections in cellular beams are straightforward, and the guidance offered in the green books (P212 and P358) can very easily be adapted. The details below are in addition to the standard checking procedures for any simple beam connection. Put simply, if there is less than half a standard web-post (So) at the end of a beam (Se) then provide a half infill. So Se So Se,N Beams without notched ends Beams with notches If se ≥ s0/2 no infill required If se,N ≥ s0/2 no infill required If se < s0/2 provide half infill (dotted) If se,N < s0/2 provide half infill Splice connections Splice connections will more often be required for non-composite roof beams. The moment in a non-composite beam is resisted by complimentary axial compression and tension in the top and bottom tees. A connection that works in a similar way is preferred. In the case of flush end-plates, web-tension local to the cell may become critical requiring a half infill. Extended end-plate connection Cover plate splice connection A 10% reduction in applied moment makes a big difference in connection design. The common practice of locating splices at third points in simple beams should be observed where possible. Specifiers should also quote the actual applied moment rather than section capacity for connection design. 16 www.kloecknerwestok.com Economic design of Westok beams The art of economic design involves striking the right balance between efficient individual member design, and rationalising the number of different beams types for production and structural detailing efficiency. It’s good practice to size Westok beams in “pairs”, particularly for asymmetric beams which have top and bottom tee’s manufactured from different serial sizes, but also for cambered and curved beams too. Breaking a project down into “bays” and adopting a standard cell diameter and pitch for each “bay” can also improve production efficiency and ensure cell alignment for service routes. Kloeckner Metals UK Westok offers a free design service and our engineers are widely experienced solving the many problems encountered by engineers as they scheme up, and design the steel frame. Talk to your local Advisory Engineer to understand how we can assist. www.kloecknerwestok.com 17 Understanding cellular beams Cellular beams resist global bending by means of a simple couple that is set up between the top and bottom tees in the case of a non-composite beam, and in the case of a composite beam between the concrete slab and the steel section. The first step in successful sizing is to ensure that the overall beam has the correct proportions. In the output panel of the Cellbeam software the “Moment Shear Utilisation” check gives a measure of how well-proportioned the beam is for overall bending. For efficient design it should be between 0.9 and 1.0. With a beam of the correct proportions for global bending attention can now be given to the secondary checks required at each cell location. Vertical shear is resisted by the webs of the top and bottom tees. Shear capacity can be increased by decreasing the cell diameter of the cell, or choosing tee sections with thicker webs. Horizontal shear is developed in each web-post due to the change in moment across the cell. In simply supported beams subject to uniform load, the critical web-post will always be the first web-post in from the support. Web-post shear capacity can be increased by increasing the cell pitch, decreasing the cell diameter, or choosing tee sections with thicker webs. Vierendeel bending occurs in the top and bottom tees due to the transfer of shear force across the openings. The software then checks every cell for the combination of shear, axial force and secondary Vierrendeel bending. In simply supported beams subject to uniform load the critical cells will be those closest local to the mid-span of the beam. Vierendeel capacity can be increased by closing the cell pitch, using a smaller diameter cell, using heavier tee sections. Web-post buckling occurs as a result of the horizontal shear at the centre line of the cell. It is a function of the web-post width and it’s slenderness (effective height divided by web thickness). Web post buckling capacity can be increased by increasing the cell pitch or decreasing the cell diameter to reduce its slenderness. 18 www.kloecknerwestok.com Fire Fire Protection Fire protection of cellular beams using “passive materials” such as boards or cementitious sprays can be applied in the same way as for a plain rolled section. For intumescent, the ASFP (Association of Specialist Fire Protection) and the SCI have worked together to establish a thorough system. Westok cellular beams may be protected by any ASFP accredited material using the limiting temperatures from the Cellbeam software. Alternatively ASFP members can refer to their own publications. The Cellbeam software calculates the critical temperature for the web and bottom flange of the cellular beam. By stating these critical temperatures on drawings the Engineer ensures maximum competition for the fire protection package. Armed with this information, any fire protection contractor or intumescent manufacturer is quickly able to calculate their optimum product and correct coating thickness. Fire Engineering with Cellular Beams Various options exist to “fire engineer” structural frames which use cellular beams. • Beam optimisation for intumescents It may be beneficial to slightly increase the steel section if this allows a significantly thinner coat of intumescent to be used. It is likely that this will only be viable in 120 minute fire ratings, and in very lightweight beams with high section factors. • Unprotected alternate floor beams An increasingly popular approach uses the method described in SCI publication P288, in which up to half the number of floor beams can be left unprotected, even for buildings requiring 120 minute fire period. Long span cellular beams are included in this approach. • Unprotected steel frames BS 5950 Part 8 and BS 9999 allow many steel frames requiring a fire protection period of 30 or 45 minutes to be totally designed without fire protection. www.kloecknerwestok.com 19 USFBs The USFB (Ultra Shallow Floor Beam) massively extends the range of shallow steel options for the flat slab market. USFBs can be as shallow as 160mm, rising in 1mm increments. The USFB is a highly asymmetric section with a wide bottom flange on which the decking or pre-cast units can sit producing a very shallow overall solution. Cells are provided at regular centres which accommodates rebar for torsional resistance and tying requirements for disproportionate collapse. Unlike other upstand beam options, the USFB is not subject to any minimum order quantities, is available in increments of 1mm depth and does not require the costly provision of additional plates or angle sections to be welded to the beam to provide an outstand element. Therefore, the USFB is perhaps the most flexible, practical and cost-efficient approach to achieving an up-stand beam in the market. The table below shows USFB equivalents to rolled ASB sections, based on geometric properties only. This will prove useful for engineers seeking a quick USFB alternative, to a ASB. All USFB equivalents must be proven by calculation using our Cellbeam software. Experience suggests that significant economies can be made when engineers design the USFB section in lieu of the ASB. Cellbeam is available, free of charge, from www.kloecknerwestok.com USFB geometric equivalents to rolled ASBs TOP FLANGE Section BOTTOM FLANGE Depth Width Thickness Width Thickness Inertia Modulus h bt tf,t bb tf,b Iz Wpl,z A mm mm mm mm mm cm4 cm3 cm2 Area 280 ASB 74 272 275 14.0 285 14.0 12200 978 93.7 265 x 203/305 USFB 91.5 265 209.1 20.5 305.3 15.4 14835 1171 105.2 280 ASB 100 276 184 16.0 294 16.0 15500 1290 120.9 276 x 203/305 USFB 117.6 276 209.1 20.5 304.8 19.7 17687 1289 120.9 280 ASB 105 288 176 22.0 286 22.0 19200 1440 133.0 288 x 254/368 USFB 118 288 258.8 20.5 368.6 17.5 22723 1654 136.0 280 ASB 124 296 178 26.0 288 26.0 23500 1730 158.0 296 x 254/368 USFB 130.5 296 261.3 25.3 368.6 17.5 26457 1971 151.0 280 ASB 136 288 190 22.0 300 22.0 22200 1810 174.0 288 x 254/368 USFB 130.5 288 261.3 25.3 368.6 17.5 24894 1911 150.0 300 ASB 153 310 190 24.0 300 24.0 28400 2160 195.0 310 x 254/368 USFB 172.1 310 265.2 31.7 372.2 23.8 36799 2636 199.0 300 ASB 155 326 179 32.0 289 32.0 34500 2360 198.0 326 x 254/368 USFB 172.1 326 265.2 31.2 372.6 23.8 41296 2811 201.0 300 ASB 185 320 195 29.0 305 29.0 35700 2660 235.0 320 x 305/419 USFB 270.7 320 314.5 31.4 418.5 32.0 50620 3335 266.0 300 ASB 196 342 183 40.0 293 40.0 45900 3060 249.0 342 x 305/419 USFB 291.7 342 318.4 37.7 418.5 32.0 63999 4208 294.0 300 ASB 249 342 203 40.0 313 40.0 52900 3760 318.0 342 x 305/419 USFB 335.4 342 322.2 44.1 420.5 36.6 71589 4717 339.0 20 www.kloecknerwestok.com Westok Plate Beams e m e e e e m and columns m e e e e e m The Westok Plate Beam is manufactured using advanced welding technology on a submerged-arc T & I line. It provides the optimum bespoke beam solution in shape and web aperture. The WPB is used in applications where there is a requirement to achieve one or both of the following: • The transfer of particularly heavy loads, where the capacity of a Westok cellular beam is exceeded • A specific arrangement of web penetrations of varying size and location - “any hole, anywhere” Westok Plate Beams generally become more economic at beam weights of 150kg/m and above, e e e e m ee e e e e me T e e e ee e ee em e e m e e e e m e e e m e e e m m e e ee e U ee e U e e e e m U What product where? M e e e m e e m e e e m US e e e ee em e e m e ee However, it also creates a dilemma for the Designer; what applications suit which particular products? Our Technical Advisory Engineers objectively recommend the right product for the right application based on a technical and commercial basis, but the simple guidance below will help Designers. Westok Cellular Beams should be the first choice for: • Secondary floor beams • Primary beams where many cells at regular spacing are required • Straight roof beams • Curved roof beams • Tapered roof beams Westok Plate Beams should be considered for: • Beams subject to heavy point loads • Primary beams where the servicing requirement can be relaxed • Beams where bespoke web openings of different sizes and locations are required • Beams heavier than 150 kg/m however speak to our advisory engineers as it is best to consider each project/application on its merits • Westok Plate Columns should be considered for: • * Applications such as high Valley Columns or Wind-Posts in single-story sheds Westok USFBs should be considered for: • Shallow floor solutions up to approximately 10m span • Where a level soffit is required www. e e e .com 21 Software SCI Cellbeam Software Cellbeam is the only cellular beam software written and maintained by the Steel Construction Institute. It is available as a free download from www.kloecknerwestok.com. V10.1 will be upgraded to V10.2 towards the end of June 2016. Westok’s Advisory Engineers also use the same software to design cellular beams. Westok has no access to the source code of the program and SCI’s decisions are final on a ll aspects of the design rules employed within it. VERS10 N .2 USFB™ Software SCI and Westok have also released software to software to aid design of Ultra Shallow Floor Beams (USFBs). This is embedded within Cellbeam. CellVibe software Client specifiations often include a performance requirement for the structural floors in the form of a maximum permitted response factor. CellVibe is an extremely quick and easy tool to use that determines the response characteristics of a floor in accordance with SCI publication P354. Westok Plate Beam software Plate beams can be designed quickly and easily using the Westok Plate Beam software. The software is written by Tekla, and is the same design engine that is used in Tekla Structural Designer and Fastrak Building Designer. All software is available as a free download from www.kloecknerwestok.com 22 www.kloecknerwestok.com Integration with 3rd party software Cellbeam Integration with other Design Software packages The most efficient way to design Westok cellular beams is to use Westok’s Cellbeam package. Cellbeam is regularly upgraded, and represents the most up to date understanding of the structural behaviour of Westok products. Use of Cellbeam will ensure the most economic design of a Westok beam. Through our collaboration with structural software houses, Westok Cellular Beams can also be defined and analysed in 3rd party software packages, such as Fastrak Building Designer (FBD), Tekla Structural Designer (TSD), and Bentley RAM Structural Systems. Engineers can take advantage of import/export functionality within these 3rd party packages, to send beams from the model to Cellbeam. The load from the model is “decomposed” into a series of line loads and point loads onto the Westok beam, and can be exported to Cellbeam. Following economic sizing, the user can opt to import the newly designed Westok beam from Cellbeam back to the model. Under certain circumstances, BS codified design can also be carried out in these 3rd party packages, although users are likely to find more efficient designs by using Cellbeam. FBD and TSD design takes place using design rules outlined in SCI’s P100 document, which was published in 1990. RAM’s design engine was developed around 2005. Alternatively, the engineer can opt to use Cellbeam as a standalone package to design a range of Westok beams. Without employing an import/export design process, these Westok beam sizes can be directly adopted in the model. BIM/Autodesk Revit Integration There a are a number of ways designers can integrate Westok cellular beams into a building model. • If using a package, such as Tekla Structural Designer (TSD) or Fastrak Building Designer (FBD) simply build the model and export to Revit • Build the model in Revit and then send a beam from the model to Cellbeam via the Westok Revit Integrator package. The beam is then designed and sized in Cellbeam, and then exported back to the model with all of the relevant info contained therein. • Contact Westok for a Revit family. The Westok Revit Integrator package can be downloaded from - www.kloecknerwestok.com www.kloecknerwestok.com 23 Quick Sizing Guide Composite secondary floor beams Westok cellular beams perform best as simply supported secondary floor beams to achieve either long spans and/or service integration. This table attempts to show some of the possible solutions using Westok cellular beams. Many, many more are possible as the cell diameter, cell spacing and beam depth are all highly flexible parameters specified by the designer. Beams should always be designed using the Cellbeam software and/or Westok’s free design service on 0113 205 5270. Optioneering – same spans different sizes Preliminary composite cellular beam sizing table for S355 steel and normal weight concrete 1kN/m2 for ceiling, services and finishes: 4 + 1kN/m2 variable/live. Depth mm Top tee Bottom tee Mass kg/m Top tee Depth mm Cell Data dia/pitch mm Deflections Const’n/variable mm Footfall response 78 177 225/345 65/31 6.0 53 273 350/525 40/17 7.9 56 317 450/675 29/13 7.3 105 214 275/417 88/35 3.5 71 312 400/600 53/25 4.7 74.5 352 565/750 40/19 5.6 131 291 350/530 96/42 2.6 93.5 340 500/750 68/34 3.3 107 446 700/1060 41/24 3.2 12m span secondary Minimum depth (span/d: approx. 35) Lightest weight Large cell (span/d: approx. 20) 350 546 637 356 x 171 UB 67 254 x 254 UC 89 406 x 140 UB 46 406 x 178 UB 60 457 x 152 UB 52 457 x 152 UB 60 15m span secondary Minimum depth (span/d: approx. 35) Lightest weight Large cell (span/d: approx. 20) 425 655 750 533 x 210 UB 92 305 x 305 UC 118 457 x 152 UB 60 533 x 210 UB 82 457 x 152 UB 67 533 x 210 UB 82 18m span secondary Minimum depth (span/d: approx. 35) Lightest weight Large cell (span/d: approx. 20) 525* 739* 895 533 x 210 UB 109 356 x 368 UC 153 457 x 191 UB 74 610 x 229 UB 113 610 x 229 UB 101 610 x 229 UB 113 Basis of design: 140 composite slab on Tata CF51 deck. Beam centres at 3m. The footfall response has been determined based on a 7.5m grid/bay and a minimum of 4 bays. Damping has been allowed at 3% “Fully fitted out floors, normal use”. * beam NF < 4Hz. 24 www.kloecknerwestok.com Quick Sizing Guide Floor grids Preliminary composite cellular beam sizing table for S355 steel and normal weight concrete 1kN/m2 for ceiling, services and finishes: 4 + 1kN/m2 variable/live. PRIMARY BEAM Prim Sec Sec span span crs m 7.5 7.5 7.5 m m Depth Top tee Mass mm Bottom tee kg/m 2.5 662 3.75 656 2.5 761 3.75 812 2.5 770 3.75 859 457 x 152 UB 82 533 x 210 UB 101 SECONDARY BEAM Top tee Cell data depth dia/pitch Depth Top tee Mass mm Bottom tee kg/m mm mm 91.5 313 400/610 590 79.5 309 400/610 617 107 379 400/625 618 107 405 500/750 737 132.5 384 400/625 737 126.5 427 550/750 819 406 x 140 UB 46 457 x 152 UB 52 Top tee Cell data Steel depth dia/pitch Weight Footfall response mm mm kN/m2 49.0 283 400/600 0.27 7.9 63.5 309 400/600 0.24 9.0 67 307 400/600 0.34 4.9 84 332 500/750 0.30 6.6 84 332 500/750 0.41 3.2 108.5 390 550/750 0.36 4.2 12 15 457 x 152 UB 67 533 x 210 UB 92 610 x 229 UB 101 610 x 229 UB 113 610 x 229 UB 101 610 x 229 UB 113 610 x 229 UB 125 610 x 229 UB 140 457 x 152 UB 60 457 x 191 UB 67 457 x 152 UB 52 457 x 191 UB 82 457 x 152 UB 67 610 x 229 UB 101 457 x 152 UB 67 610 x 229 UB 101 18 610 x 229 UB 113 610 x 229 UB 140 533 x 210 UB 92 610 x 229 UB 125 This table attempts to show some of the possible solutions using Westok cellular beams. Many, many more are possible as the cell diameter, cell spacing and beam depth are all highly flexible parameters specified by the designer. Beams should always be designed using the Cellbeam software and/or Westok’s free design service on 0113 205 5270. Basis of design: • 140 composite slab on Tata steel CF51 steel decking allowed for 2.5m secondary beam spacing. • 140 composite slab on Tata steel CF60 steel decking allowed for 3.75m secondary beam spacing. • The footfall response has been determined based on 6m grid/bay and a minimum of 4 bays. Damping has been allowed at 3% “Fully fitted out floors, normal use”. www.kloecknerwestok.com 25 Quick Sizing Guide Roof Beams Westok cellular beams will typically have 50% greater strength and 125% greater stiffness compared to the parent section from which they were made. In lightly loaded long span roof applications they are the perfect solution, being lighter than a plain UB and cheaper to fabricate and paint than a truss. The table below gives an indication of the spans achievable. Project specific sizes should always be designed using the Cellbeam software and/or Westok’s free design service. Guide roof beam sizes Preliminary cellular beam sizing table for simply supported roof beams in S355 steel Span m Section Cell Data dia/ pitch mm Deflections variable load mm Span/200 mm 15 Westok 442 x 165 x 40 CB 325/455 62 75 20 Westok 669 x 191 x 67 CB 475/625 55 100 25 Westok 738 x 210 x 82 CB 550/700 83 125 30 Westok 887 x 229 x 101 CB 625/835 108 150 35 Westok 909 x 229 x 125 CB 650/865 170 151 40 Westok 1123 x 267 x 147 CB 780/960 151 200 45 Westok 1144 x 267 x 173 CB 800/960 195 225 50 Westok 1323 x 305 x 201 CB 875/1040 196 250 Basis of design: • Beam centres at 6m • 0.5kN/m2 for cladding, purlins & services and finishes • 0.6kN/m2 variable/live: 0.5kN/m2 wind pressure 26 www.kloecknerwestok.com References SCI Publication P100 (1990) Design of Composite and Non-Composite Cellular Beams SCI Publication P212 (2002, 2009) Joints in Steel Construction: Simple Connections SCI Publication P288 (2006) Fire Safe Design – A new approach to multi-storey steel framed buildings (Second Edition) MCRMA/SCI Publication P300 (2009) Composite slabs and beams using steel decking: Best practice for design and construction SCI Publication P354 (2009) Design of Floors for Vibration: A New Approach: Revised Edition SCI Publication P355 (2011) Design of Composite Beams with Large Web Openings SCI Publication P358 (2011) Joints in Steel Construction: Simple Joints to Eurocode 3 SCI Publication P405 (2015) Minimum degree of shear connection rules for UK Construction to EC4 AD 344 Levelling techniques for composite floors The Westok Cellular Beam Pocket Guide Version 1.01: June 2016 Version 1.02: January 2016 – Company name and details on back page updated to suit re-brand www.kloecknerwestok.com 27 UK Beams: Dimensions Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Section Designation 1016 x 305 x x x x x x x x 914 x 419 x x 914 x 305 x x x x 838 x 292 x x x 762 x 267 x x x x 686 x 254 x x x x 610 x 305 x x x 610 x 229 x x x x 610 x 178 x x x 533 x 312 x x x x 487 437 393 349 314 272 249 222 388 343 289 253 224 201 226 194 176 197 173 147 134 170 152 140 125 238 179 149 140 125 113 101 100 92 82 272 219 182 150 + + + + + + + + + + + + + + + Mass per Metre Depth Width Root Depth Thickness of of Radius between Section Section Web Flange Fillets h b tw tf r d kg/m 486.7 437 392.7 349.4 314.3 272.3 248.7 222 388 343.3 289.1 253.4 224.2 200.9 226.5 193.8 175.9 196.8 173 146.9 133.9 170.2 152.4 140.1 125.2 238.1 179 149.2 139.9 125.1 113 101.2 100.3 92.2 81.8 273.3 218.8 181.5 150.6 mm 1036.3 1026.1 1015.9 1008.1 999.9 990.1 980.1 970.3 921 911.8 926.6 918.4 910.4 903 850.9 840.7 834.9 769.8 762.2 754 750 692.9 687.5 683.5 677.9 635.8 620.2 612.4 617.2 612.2 607.6 602.6 607.4 603 598.6 577.1 560.3 550.7 542.5 mm 308.5 305.4 303 302 300 300 300 300 420.5 418.5 307.7 305.5 304.1 303.3 293.8 292.4 291.7 268 266.7 265.2 264.4 255.8 254.5 253.7 253 311.4 307.1 304.8 230.2 229 228.2 227.6 179.2 178.8 177.9 320.2 317.4 314.5 312 mm 30 26.9 24.4 21.1 19.1 16.5 16.5 16 21.4 19.4 19.5 17.3 15.9 15.1 16.1 14.7 14 15.6 14.3 12.8 12 14.5 13.2 12.4 11.7 18.4 14.1 11.8 13.1 11.9 11.1 10.5 11.3 10.9 10 21.1 18.3 15.2 12.7 mm 54.1 49 43.9 40 35.9 31 26 21.1 36.6 32 32 27.9 23.9 20.2 26.8 21.7 18.8 25.4 21.6 17.5 15.5 23.7 21 19 16.2 31.4 23.6 19.7 22.1 19.6 17.3 14.8 17.2 15 12.8 37.6 29.2 24.4 20.3 mm 30 30 30 30 30 30 30 30 24.1 24.1 19.1 19.1 19.1 19.1 17.8 17.8 17.8 16.5 16.5 16.5 16.5 15.2 15.2 15.2 15.2 16.5 16.5 16.5 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 mm 868.1 868.1 868.1 868.1 868.1 868.1 868.1 868.1 799.6 799.6 824.4 824.4 824.4 824.4 761.7 761.7 761.7 686 686 686 686 615.1 615.1 615.1 615.1 540 540 540 547.6 547.6 547.6 547.6 547.6 547.6 547.6 476.5 476.5 476.5 476.5 Ratios for Local Buckling Web Flange cw / tw 28.9 32.3 35.6 41.1 45.5 52.6 52.6 54.3 37.4 41.2 42.3 47.7 51.8 54.6 47.3 51.8 54.4 44 48 53.6 57.2 42.4 46.6 49.6 52.6 29.3 38.3 45.8 41.8 46 49.3 52.2 48.5 50.2 54.8 22.6 26 31.3 37.5 Dimensions for Detailing End Notch Clearance Surface Area Per Per Metre Tonne cf / tf C N n 2.02 2.23 2.49 2.76 3.08 3.6 4.3 5.31 4.79 5.48 3.91 4.48 5.23 6.19 4.52 5.58 6.44 4.32 5.08 6.27 7.08 4.45 5.02 5.55 6.51 4.14 5.51 6.6 4.34 4.89 5.54 6.48 4.14 4.75 5.57 3.64 4.69 5.61 6.75 mm 17 15 14 13 12 10 10 10 13 12 12 11 10 10 10 9 9 10 9 8 8 9 9 8 8 11 9 8 9 8 8 7 8 7 7 13 11 10 8 mm 150 150 150 152 152 152 152 152 210 210 156 156 156 156 150 150 150 138 138 138 138 132 132 132 132 158 158 158 120 120 120 120 94 94 94 160 160 160 160 mm 86 80 74 70 66 62 56 52 62 58 52 48 44 40 46 40 38 42 40 34 32 40 38 36 32 48 42 38 36 34 30 28 30 28 26 52 42 38 34 m2 3.2 3.17 3.14 3.13 3.11 3.1 3.08 3.06 3.44 3.42 3.01 2.99 2.97 2.96 2.81 2.79 2.78 2.55 2.53 2.51 2.51 2.35 2.34 2.33 2.32 2.45 2.41 2.39 2.11 2.09 2.08 2.07 1.89 1.88 1.87 2.37 2.33 2.31 2.29 m2 6.58 7.25 8 8.96 9.89 11.4 12.4 13.8 8.87 9.96 10.4 11.8 13.2 14.7 12.4 14.4 15.8 13 14.6 17.1 18.7 13.8 15.4 16.6 18.5 10.3 13.5 16 15.1 16.7 18.4 20.5 18.8 20.4 22.9 8.67 10.7 12.7 15.2 + These sections are in addition to the BS4 range 28 www.kloecknerwestok.com UK Beams: Properties Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Section Designation 1016 x 305 x x x x x x x x 914 x 419 x x 914 x 305 x x x x 838 x 292 x x x 762 x 267 x x x x 686 x 254 x x x x 610 x 305 x x x 610 x 229 x x x x 610 x 178 x x x 533 x 312 x x x x 487 437 393 349 314 272 249 222 388 343 289 253 224 201 226 194 176 197 173 147 134 170 152 140 125 238 179 149 140 125 113 101 100 92 82 272 219 182 150 Second Moment of Area y‐y z‐z + + + + + + + + + + + + + + + cm4 1020000 910000 808000 723000 644000 554000 481000 408000 720000 626000 504000 436000 376000 325000 340000 279000 246000 240000 205000 169000 151000 170000 150000 136000 118000 209000 153000 126000 112000 98600 87300 75800 72500 64600 55900 199000 151000 123000 101000 cm4 26700 23400 20500 18500 16200 14000 11800 9550 45400 39200 15600 13300 11200 9420 11400 9070 7800 8170 6850 5460 4790 6630 5780 5180 4380 15800 11400 9310 4510 3930 3430 2910 1660 1440 1210 20600 15600 12700 10300 Radius of Gyration y‐y z‐z cm 40.6 40.4 40.2 40.3 40.1 40 39 38 38.2 37.8 37 36.8 36.3 35.7 34.3 33.6 33.1 30.9 30.5 30 29.7 28 27.8 27.6 27.2 26.3 25.9 25.7 25 24.9 24.6 24.2 23.8 23.4 23.2 23.9 23.3 23.1 22.9 cm 6.57 6.49 6.4 6.44 6.37 6.35 6.09 5.81 9.59 9.46 6.51 6.42 6.27 6.07 6.27 6.06 5.9 5.71 5.58 5.4 5.3 5.53 5.46 5.39 5.24 7.23 7.07 7 5.03 4.97 4.88 4.75 3.6 3.5 3.4 7.69 7.48 7.4 7.32 Elastic Modulus y‐y z‐z cm3 19700 17700 15900 14300 12900 11200 9820 8410 15600 13700 10900 9500 8270 7200 7980 6640 5890 6230 5390 4470 4020 4920 4370 3990 3480 6590 4930 4110 3620 3220 2870 2520 2390 2140 1870 6890 5400 4480 3710 cm3 1730 1540 1350 1220 1080 934 784 636 2160 1870 1010 871 739 621 773 620 535 610 514 411 362 518 455 409 346 1020 743 611 391 343 301 256 185 161 136 1290 982 806 659 Plastic Modulus y‐y z‐z cm3 23200 20800 18500 16600 14800 12800 11300 9810 17700 15500 12600 10900 9530 8350 9160 7640 6810 7170 6200 5160 4640 5630 5000 4560 3990 7490 5550 4590 4140 3680 3280 2880 2790 2510 2190 7870 6120 5040 4150 cm3 2800 2470 2170 1940 1710 1470 1240 1020 3340 2890 1600 1370 1160 982 1210 974 842 958 807 647 570 811 710 638 542 1570 1140 937 611 535 469 400 296 258 218 1990 1510 1240 1010 Buckling Torsional Warping Torsional Paramete Index Constant Constant U X Iw I T Area of Section A 0.867 0.868 0.868 0.872 0.872 0.872 0.861 0.85 0.885 0.883 0.867 0.865 0.86 0.853 0.869 0.862 0.856 0.869 0.865 0.858 0.853 0.872 0.871 0.87 0.863 0.886 0.885 0.886 0.875 0.875 0.87 0.863 0.854 0.85 0.843 0.891 0.884 0.886 0.885 21.1 23.1 25.5 27.9 30.7 35 39.9 45.7 26.7 30.1 31.9 36.2 41.3 46.9 35 41.6 46.5 33.1 38 45.2 49.8 31.8 35.4 38.6 43.8 21.3 27.7 32.7 30.6 34 38 43 38.7 42.7 48.5 15.9 19.8 23.4 27.8 dm6 64.4 56 48.4 43.3 37.7 32.2 26.8 21.5 88.9 75.8 31.2 26.4 22.1 18.4 19.3 15.2 13 11.3 9.39 7.4 6.46 7.42 6.42 5.72 4.8 14.5 10.2 8.17 3.99 3.45 2.99 2.52 1.44 1.24 1.04 15 11 8.77 7.01 cm4 4300 3190 2330 1720 1260 835 582 390 1730 1190 926 626 422 291 514 306 221 404 267 159 119 308 220 169 116 785 340 200 216 154 111 77 95 71 48.8 1290 642 373 216 cm2 620 557 500 445 400 347 317 283 494 437 368 323 286 256 289 247 224 251 220 187 171 217 194 178 159 303 228 190 178 159 144 129 128 117 104 348 279 231 192 Source: Tata Steel sections interactive 'blue book' version 5.5 ‐ reproduced with kind permision of Tata Steel www.kloecknerwestok.com 29 UK Beams: Dimensions Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Mass per Metre Section Designation 533 x 210 x x x x x x 533 x 165 x x x 457 x 191 x x x x x x x x 457 x 152 x x x x x 406 x 178 x x x x x 406 x 140 x x x 356 x 171 x x x x 356 x 127 x x 305 x 165 x x x 138 122 109 101 92 82 85 74 66 161 133 106 98 89 82 74 67 82 74 67 60 52 85 74 67 60 54 53 46 39 67 57 51 45 39 33 54 46 40 + + + + + + + + + kg/m 138.3 122 109 101 92.1 82.2 84.8 74.7 65.7 161.4 133.3 105.8 98.3 89.3 82 74.3 67.1 82.1 74.2 67.2 59.8 52.3 85.3 74.2 67.1 60.1 54.1 53.3 46 39 67.1 57 51 45 39.1 33.1 54 46.1 40.3 Depth Width Root Depth Thickness of of Radius between Section Section Web Flange Fillets h b tw tf r d mm 549.1 544.5 539.5 536.7 533.1 528.3 534.9 529.1 524.7 492 480.6 469.2 467.2 463.4 460 457 453.4 465.8 462 458 454.6 449.8 417.2 412.8 409.4 406.4 402.6 406.6 403.2 398 363.4 358 355 351.4 353.4 349 310.4 306.6 303.4 mm 213.9 211.9 210.8 210 209.3 208.8 166.5 165.9 165.1 199.4 196.7 194 192.8 191.9 191.3 190.4 189.9 155.3 154.4 153.8 152.9 152.4 181.9 179.5 178.8 177.9 177.7 143.3 142.2 141.8 173.2 172.2 171.5 171.1 126 125.4 166.9 165.7 165 mm 14.7 12.7 11.6 10.8 10.1 9.6 10.3 9.7 8.9 18 15.3 12.6 11.4 10.5 9.9 9 8.5 10.5 9.6 9 8.1 7.6 10.9 9.5 8.8 7.9 7.7 7.9 6.8 6.4 9.1 8.1 7.4 7 6.6 6 7.9 6.7 6 mm 23.6 21.3 18.8 17.4 15.6 13.2 16.5 13.6 11.4 32 26.3 20.6 19.6 17.7 16 14.5 12.7 18.9 17 15 13.3 10.9 18.2 16 14.3 12.8 10.9 12.9 11.2 8.6 15.7 13 11.5 9.7 10.7 8.5 13.7 11.8 10.2 mm 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 8.9 8.9 8.9 mm 476.5 476.5 476.5 476.5 476.5 476.5 476.5 476.5 476.5 407.6 407.6 407.6 407.6 407.6 407.6 407.6 407.6 407.6 407.6 407.6 407.6 407.6 360.4 360.4 360.4 360.4 360.4 360.4 360.4 360.4 311.6 311.6 311.6 311.6 311.6 311.6 265.2 265.2 265.2 Ratios for Local Buckling Web Flange cw / tw 32.4 37.5 41.1 44.1 47.2 49.6 46.3 49.1 53.5 22.6 26.6 32.3 35.8 38.8 41.2 45.3 48 38.8 42.5 45.3 50.3 53.6 33.1 37.9 41 45.6 46.8 45.6 53 56.3 34.2 38.5 42.1 44.5 47.2 51.9 33.6 39.6 44.2 Dimensions for Detailing Notch End Clearance Surface Area Per Per Metre Tonne cf / tf C N n 3.68 4.08 4.62 4.99 5.57 6.58 3.96 4.81 5.74 2.52 3.06 3.91 4.11 4.55 5.03 5.55 6.34 3.29 3.66 4.15 4.68 5.71 4.14 4.68 5.23 5.84 6.86 4.46 5.13 6.69 4.58 5.53 6.25 7.41 4.63 5.82 5.15 5.98 6.92 mm 9 8 8 7 7 7 7 7 6 11 10 8 8 7 7 7 6 7 7 7 6 6 7 7 6 6 6 6 5 5 7 6 6 6 5 5 6 5 5 mm 110 110 110 110 110 110 90 90 90 102 102 102 102 102 102 102 102 84 84 84 84 84 96 96 96 96 96 78 78 78 94 94 94 94 70 70 90 90 90 mm 38 34 32 32 30 26 30 28 26 44 38 32 30 28 28 26 24 30 28 26 24 22 30 28 26 24 22 24 22 20 26 24 22 20 22 20 24 22 20 m2 1.9 1.89 1.88 1.87 1.86 1.85 1.69 1.68 1.67 1.73 1.7 1.67 1.67 1.66 1.65 1.64 1.63 1.51 1.5 1.5 1.49 1.48 1.52 1.51 1.5 1.49 1.48 1.35 1.34 1.33 1.38 1.37 1.36 1.36 1.18 1.17 1.26 1.25 1.24 m2 13.7 15.5 17.2 18.5 20.2 22.5 19.9 22.5 25.4 10.7 12.8 15.8 17 18.6 20.1 22.1 24.3 18.4 20.2 22.3 24.9 28.3 17.8 20.4 22.3 24.8 27.3 25.3 29.1 34.1 20.6 24.1 26.7 30.2 30.2 35.4 23.3 27.1 30.8 + These sections are in addition to the BS4 range 30 www.kloecknerwestok.com UK Beams: Properties Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Section Designation 533 x 210 x x x x x x 533 x 165 x x x 457 x 191 x x x x x x x x 457 x 152 x x x x x 406 x 178 x x x x x 406 x 140 x x x 356 x 171 x x x x 356 x 127 x x 305 x 165 x x x 138 122 109 101 92 82 85 74 66 161 133 106 98 89 82 74 67 82 74 67 60 52 85 74 67 60 54 53 46 39 67 57 51 45 39 33 54 46 40 Second Moment of Area y‐y z‐z + + + + + + + + + cm4 86100 76000 66800 61500 55200 47500 48500 41100 35000 79800 63800 48900 45700 41000 37100 33300 29400 36600 32700 28900 25500 21400 31700 27300 24300 21600 18700 18300 15700 12500 19500 16000 14100 12100 10200 8250 11700 9900 8500 cm4 3860 3390 2940 2690 2390 2010 1270 1040 859 4250 3350 2510 2350 2090 1870 1670 1450 1180 1050 913 795 645 1830 1550 1360 1200 1020 635 538 410 1360 1110 968 811 358 280 1060 896 764 Radius of Gyration y‐y z‐z cm 22.1 22.1 21.9 21.9 21.7 21.3 21.2 20.8 20.5 19.7 19.4 19 19.1 19 18.8 18.8 18.5 18.7 18.6 18.4 18.3 17.9 17.1 17 16.9 16.8 16.5 16.4 16.4 15.9 15.1 14.9 14.8 14.5 14.3 14 13 13 12.9 cm 4.68 4.67 4.6 4.57 4.51 4.38 3.44 3.3 3.2 4.55 4.44 4.32 4.33 4.29 4.23 4.2 4.12 3.37 3.33 3.27 3.23 3.11 4.11 4.04 3.99 3.97 3.85 3.06 3.03 2.87 3.99 3.91 3.86 3.76 2.68 2.58 3.93 3.9 3.86 Elastic Modulus y‐y z‐z cm3 3140 2790 2480 2290 2070 1800 1820 1550 1340 3240 2660 2080 1960 1770 1610 1460 1300 1570 1410 1260 1120 950 1520 1320 1190 1060 930 899 778 629 1070 896 796 687 576 473 754 646 560 cm3 361 320 279 256 228 192 153 125 104 426 341 259 243 218 196 176 153 153 136 119 104 84.6 201 172 153 135 115 88.6 75.7 57.8 157 129 113 94.8 56.8 44.7 127 108 92.6 Plastic Modulus y‐y z‐z cm3 3610 3200 2830 2610 2360 2060 2100 1810 1560 3780 3070 2390 2230 2010 1830 1650 1470 1810 1630 1450 1290 1100 1730 1500 1350 1200 1050 1030 888 724 1210 1010 896 775 659 543 846 720 623 cm3 568 500 436 399 355 300 243 200 166 672 535 405 379 338 304 272 237 240 213 187 163 133 313 267 237 209 178 139 118 90.8 243 199 174 147 89 70.2 196 166 142 Buckling Torsional Warping Torsional Paramete Index Constant Constant U X Iw I T Area of Section A 0.874 0.878 0.875 0.874 0.873 0.863 0.861 0.853 0.847 0.881 0.879 0.876 0.881 0.878 0.879 0.877 0.873 0.872 0.872 0.868 0.868 0.859 0.88 0.882 0.88 0.88 0.871 0.87 0.871 0.858 0.886 0.882 0.881 0.874 0.871 0.863 0.889 0.89 0.889 24.9 27.6 30.9 33.1 36.4 41.6 35.5 41.1 47 16.5 19.6 24.4 25.8 28.3 30.8 33.8 37.8 27.4 30.1 33.6 37.5 43.8 24.4 27.5 30.4 33.7 38.3 34.1 39 47.4 24.4 28.8 32.1 36.8 35.2 42.1 23.6 27.1 31 dm6 2.67 2.32 1.99 1.81 1.6 1.33 0.857 0.691 0.566 2.25 1.73 1.27 1.18 1.04 0.922 0.818 0.705 0.591 0.518 0.448 0.387 0.311 0.728 0.608 0.533 0.466 0.392 0.246 0.207 0.155 0.412 0.33 0.286 0.237 0.105 0.081 0.234 0.195 0.164 cm4 250 178 126 101 75.7 51.5 73.8 47.9 32 515 292 146 121 90.7 69.2 51.8 37.1 89.2 65.9 47.7 33.8 21.4 93 62.8 46.1 33.3 23.1 29 19 10.7 55.7 33.4 23.8 15.8 15.1 8.79 34.8 22.2 14.7 cm2 176 155 139 129 117 105 108 95.2 83.7 206 170 135 125 114 104 94.6 85.5 105 94.5 85.6 76.2 66.6 109 94.5 85.5 76.5 69 67.9 58.6 49.7 85.5 72.6 64.9 57.3 49.8 42.1 68.8 58.7 51.3 Source: Tata Steel sections interactive 'blue book' version 5.5 ‐ reproduced with kind permision of Tata Steel www.kloecknerwestok.com 31 UK Beams: Dimensions Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Section Designation 305 x 127 x x x 305 x 102 x x x 254 x 146 x x x 254 x 102 x x x 203 x 133 x x 203 x 102 x 178 x 102 x 152 x 89 x 127 x 76 x 48 42 37 33 28 25 43 37 31 28 25 22 30 25 23 19 16 13 Mass per Metre kg/m 48.1 41.9 37 32.8 28.2 24.8 43 37 31.1 28.3 25.2 22 30 25.1 23.1 19 16 13 Depth Width Root Depth Thickness of of Radius between Section Section Web Flange Fillets h b tw tf r d mm 311 307.2 304.4 312.7 308.7 305.1 259.6 256 251.4 260.4 257.2 254 206.8 203.2 203.2 177.8 152.4 127 mm 125.3 124.3 123.4 102.4 101.8 101.6 147.3 146.4 146.1 102.2 101.9 101.6 133.9 133.2 101.8 101.2 88.7 76 mm 9 8 7.1 6.6 6 5.8 7.2 6.3 6 6.3 6 5.7 6.4 5.7 5.4 4.8 4.5 4 mm 14 12.1 10.7 10.8 8.8 7 12.7 10.9 8.6 10 8.4 6.8 9.6 7.8 9.3 7.9 7.7 7.6 mm 8.9 8.9 8.9 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 mm 265.2 265.2 265.2 275.9 275.9 275.9 219 219 219 225.2 225.2 225.2 172.4 172.4 169.4 146.8 121.8 96.6 Ratios for Local Buckling Web Flange cw / tw 29.5 33.2 37.4 41.8 46 47.6 30.4 34.8 36.5 35.7 37.5 39.5 26.9 30.2 31.4 30.6 27.1 24.2 Dimensions for Detailing Notch End Clearance Surface Area Per Per Metre Tonne cf / tf C N n 3.52 4.07 4.6 3.73 4.58 5.76 4.92 5.73 7.26 4.04 4.8 5.93 5.85 7.2 4.37 5.14 4.48 3.74 mm 7 6 6 5 5 5 6 5 5 5 5 5 5 5 5 4 4 4 mm 70 70 70 58 58 58 82 82 82 58 58 58 74 74 60 60 54 46 mm 24 22 20 20 18 16 22 20 18 18 16 16 18 16 18 16 16 16 m2 1.09 1.08 1.07 1.01 1 0.992 1.08 1.07 1.06 0.904 0.897 0.89 0.923 0.915 0.79 0.738 0.638 0.537 m2 22.7 25.8 28.9 30.8 35.5 40 25.1 28.9 34 31.9 35.7 40.5 30.8 36.5 34.2 38.7 40 41.4 + These sections are in addition to the BS4 range 32 www.kloecknerwestok.com UK Beams: Properties Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Section Designation 305 x 127 x x x 305 x 102 x x x 254 x 146 x x x 254 x 102 x x x 203 x 133 x x 203 x 102 x 178 x 102 x 152 x 89 x 127 x 76 x 48 42 37 33 28 25 43 37 31 28 25 22 30 25 23 19 16 13 Second Moment of Area y‐y z‐z cm4 9570 8200 7170 6500 5370 4460 6540 5540 4410 4000 3410 2840 2900 2340 2100 1360 834 473 cm4 461 389 336 194 155 123 677 571 448 179 149 119 385 308 164 137 89.8 55.7 Radius of Gyration y‐y z‐z cm 12.5 12.4 12.3 12.5 12.2 11.9 10.9 10.8 10.5 10.5 10.3 10.1 8.71 8.56 8.46 7.48 6.41 5.35 cm 2.74 2.7 2.67 2.15 2.08 1.97 3.52 3.48 3.36 2.22 2.15 2.06 3.17 3.1 2.36 2.37 2.1 1.84 Elastic Modulus y‐y z‐z cm3 616 534 471 416 348 292 504 433 351 308 266 224 280 230 207 153 109 74.6 cm3 73.6 62.6 54.5 37.9 30.5 24.2 92 78 61.3 34.9 29.2 23.5 57.5 46.2 32.2 27 20.2 14.7 Plastic Modulus y‐y z‐z cm3 711 614 539 481 403 342 566 483 393 353 306 259 314 258 234 171 123 84.2 cm3 116 98.4 85.4 60 48.4 38.8 141 119 94.1 54.8 46 37.3 88.2 70.9 49.7 41.6 31.2 22.6 Buckling Torsional Warping Torsional Paramete Index Constant Constant U X Iw I T Area of Section A 0.873 0.872 0.872 0.867 0.859 0.846 0.891 0.89 0.879 0.873 0.866 0.856 0.882 0.876 0.888 0.886 0.89 0.894 23.3 26.5 29.7 31.6 37.3 43.4 21.1 24.3 29.6 27.5 31.4 36.3 21.5 25.6 22.4 22.6 19.5 16.3 dm6 0.102 0.0846 0.0725 0.0442 0.0349 0.027 0.103 0.0857 0.066 0.028 0.023 0.0182 0.0374 0.0294 0.0154 0.0099 0.0047 0.002 cm4 31.8 21.1 14.8 12.2 7.4 4.77 23.9 15.3 8.55 9.57 6.42 4.15 10.3 5.96 7.02 4.41 3.56 2.85 cm2 61.2 53.4 47.2 41.8 35.9 31.6 54.8 47.2 39.7 36.1 32 28 38.2 32 29.4 24.3 20.3 16.5 Source: Tata Steel sections interactive 'blue book' version 5.5 ‐ reproduced with kind permision of Tata Steel www.kloecknerwestok.com 33 UK Columns: Dimensions Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Mass per Metre Section Designation 356 x 406 x x x x x x x 356 x 368 x x x x 305 x 305 x x x x x x x 254 x 254 x x x x x 203 x 203 x x x x x x x x 152 x 152 x x x x x 634 551 467 393 340 287 235 202 177 153 129 283 240 198 158 137 118 97 167 132 107 89 73 127 113 100 86 71 60 52 46 51 44 37 30 23 + + + + + kg/m 633.9 551 467 393 339.9 287.1 235.1 201.9 177 152.9 129 282.9 240 198.1 158.1 136.9 117.9 96.9 167.1 132 107.1 88.9 73.1 127.5 113.5 99.6 86.1 71 60 52 46.1 51.2 44 37 30 23 Depth Width Root Depth Thickness of of Radius between Section Section Web Flange Fillets h b tw tf r d mm 474.6 455.6 436.6 419 406.4 393.6 381 374.6 368.2 362 355.6 365.3 352.5 339.9 327.1 320.5 314.5 307.9 289.1 276.3 266.7 260.3 254.1 241.4 235 228.6 222.2 215.8 209.6 206.2 203.2 170.2 166 161.8 157.6 152.4 mm 424 418.5 412.2 407 403 399 394.8 374.7 372.6 370.5 368.6 322.2 318.4 314.5 311.2 309.2 307.4 305.3 265.2 261.3 258.8 256.3 254.6 213.9 212.1 210.3 209.1 206.4 205.8 204.3 203.6 157.4 155.9 154.4 152.9 152.2 mm 47.6 42.1 35.8 30.6 26.6 22.6 18.4 16.5 14.4 12.3 10.4 26.8 23 19.1 15.8 13.8 12 9.9 19.2 15.3 12.8 10.3 8.6 18.1 16.3 14.5 12.7 10 9.4 7.9 7.2 11 9.5 8 6.5 5.8 mm 77 67.5 58 49.2 42.9 36.5 30.2 27 23.8 20.7 17.5 44.1 37.7 31.4 25 21.7 18.7 15.4 31.7 25.3 20.5 17.3 14.2 30.1 26.9 23.7 20.5 17.3 14.2 12.5 11 15.7 13.6 11.5 9.4 6.8 mm 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 15.2 12.7 12.7 12.7 12.7 12.7 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 7.6 7.6 7.6 7.6 7.6 mm 290.2 290.2 290.2 290.2 290.2 290.2 290.2 290.2 290.2 290.2 290.2 246.7 246.7 246.7 246.7 246.7 246.7 246.7 200.3 200.3 200.3 200.3 200.3 160.8 160.8 160.8 160.8 160.8 160.8 160.8 160.8 123.6 123.6 123.6 123.6 123.6 Ratios for Local Buckling Web Flange cw / tw 6.1 6.89 8.11 9.48 10.9 12.8 15.8 17.6 20.2 23.6 27.9 9.21 10.7 12.9 15.6 17.9 20.6 24.9 10.4 13.1 15.6 19.4 23.3 8.88 9.87 11.1 12.7 16.1 17.1 20.4 22.3 11.2 13 15.5 19 21.3 Dimensions for Detailing Notch End Clearance Surface Area Per Per Metre Tonne cf / tf C N n 2.25 2.56 2.98 3.52 4.03 4.74 5.73 6.07 6.89 7.92 9.37 3 3.51 4.22 5.3 6.11 7.09 8.6 3.48 4.36 5.38 6.38 7.77 2.91 3.26 3.7 4.29 5.09 6.2 7.04 8 4.18 4.82 5.7 6.98 9.65 mm 26 23 20 17 15 13 11 10 9 8 7 15 14 12 10 9 8 7 12 10 8 7 6 11 10 9 8 7 7 6 6 8 7 6 5 5 mm 200 200 200 200 200 200 200 190 190 190 190 158 158 158 158 158 158 158 134 134 134 134 134 108 108 108 110 110 110 110 110 84 84 84 84 84 mm 94 84 74 66 60 52 46 44 40 36 34 60 54 48 42 38 34 32 46 38 34 30 28 42 38 34 32 28 26 24 22 24 22 20 18 16 m2 2.52 2.47 2.42 2.38 2.35 2.31 2.28 2.19 2.17 2.16 2.14 1.94 1.91 1.87 1.84 1.82 1.81 1.79 1.58 1.55 1.52 1.5 1.49 1.28 1.27 1.25 1.24 1.22 1.21 1.2 1.19 0.935 0.924 0.912 0.901 0.889 m2 3.98 4.48 5.18 6.06 6.91 8.05 9.7 10.8 12.3 14.1 16.6 6.86 7.96 9.44 11.6 13.3 15.4 18.5 9.46 11.7 14.2 16.9 20.4 10 11.2 12.6 14.4 17.2 20.2 23.1 25.8 18.3 21 24.7 30 38.7 + These sections are in addition to the BS4 range 34 www.kloecknerwestok.com UK Columns: Properties Standard(s): EN 1993‐1‐1: 2005, BS 4‐1: 2005 Section Designation 356 x 406 x x x x x x x 356 x 368 x x x x 305 x 305 x x x x x x x 254 x 254 x x x x x 203 x 203 x x x x x x x x 152 x 152 x x x x x 634 551 467 393 340 287 235 202 177 153 129 283 240 198 158 137 118 97 167 132 107 89 73 127 113 100 86 71 60 52 46 51 44 37 30 23 Second Moment of Area y‐y z‐z + + + + + cm4 275000 227000 183000 147000 123000 99900 79100 66300 57100 48600 40200 78900 64200 50900 38700 32800 27700 22200 30000 22500 17500 14300 11400 15400 13300 11300 9450 7620 6130 5260 4570 3230 2700 2210 1750 1250 cm4 98100 82700 67800 55400 46900 38700 31000 23700 20500 17600 14600 24600 20300 16300 12600 10700 9060 7310 9870 7530 5930 4860 3910 4920 4290 3680 3130 2540 2070 1780 1550 1020 860 706 560 400 Radius of Gyration y‐y z‐z cm 18.4 18 17.5 17.1 16.8 16.5 16.3 16.1 15.9 15.8 15.6 14.8 14.5 14.2 13.9 13.7 13.6 13.4 11.9 11.6 11.3 11.2 11.1 9.75 9.59 9.44 9.28 9.18 8.96 8.91 8.82 7.04 6.94 6.85 6.76 6.54 cm 11 10.9 10.7 10.5 10.4 10.3 10.2 9.6 9.54 9.49 9.43 8.27 8.15 8.04 7.9 7.83 7.77 7.69 6.81 6.69 6.59 6.55 6.48 5.5 5.45 5.39 5.34 5.3 5.2 5.18 5.13 3.96 3.92 3.87 3.83 3.7 Elastic Modulus y‐y z‐z cm3 11600 9960 8380 7000 6030 5070 4150 3540 3100 2680 2260 4320 3640 3000 2370 2050 1760 1450 2080 1630 1310 1100 898 1280 1130 988 850 706 584 510 450 379 326 273 222 164 cm3 4630 3950 3290 2720 2330 1940 1570 1260 1100 948 793 1530 1280 1040 808 692 589 479 744 576 458 379 307 460 404 350 299 246 201 174 152 130 110 91.5 73.3 52.6 Plastic Modulus y‐y z‐z cm3 14200 12100 10000 8220 7000 5810 4690 3970 3460 2960 2480 5110 4250 3440 2680 2300 1960 1590 2420 1870 1480 1220 992 1520 1330 1150 977 799 656 567 497 438 372 309 248 182 cm3 7110 6060 5030 4150 3540 2950 2380 1920 1670 1430 1200 2340 1950 1580 1230 1050 895 726 1140 878 697 575 465 704 618 534 456 374 305 264 231 199 169 140 112 80.1 Buckling Torsional Warping Torsional Paramete Index Constant Constant U X Iw I T Area of Section A 0.843 0.841 0.839 0.837 0.836 0.835 0.834 0.844 0.844 0.844 0.844 0.855 0.854 0.854 0.851 0.851 0.85 0.85 0.851 0.85 0.848 0.85 0.849 0.854 0.853 0.852 0.85 0.853 0.846 0.848 0.847 0.848 0.848 0.848 0.849 0.84 5.46 6.05 6.86 7.86 8.85 10.2 12.1 13.4 15 17 19.9 7.65 8.74 10.2 12.5 14.2 16.2 19.3 8.49 10.3 12.4 14.5 17.3 7.38 8.11 9.02 10.2 11.9 14.1 15.8 17.7 10.1 11.5 13.3 16 20.7 dm6 38.8 31.1 24.3 18.9 15.5 12.3 9.54 7.16 6.09 5.11 4.18 6.35 5.03 3.88 2.87 2.39 1.98 1.56 1.63 1.19 0.898 0.717 0.562 0.549 0.464 0.386 0.318 0.25 0.197 0.167 0.143 0.061 0.0499 0.0399 0.0308 0.0212 cm4 13700 9240 5810 3550 2340 1440 812 558 381 251 153 2030 1270 734 378 249 161 91.2 626 319 172 102 57.6 427 305 210 137 80.2 47.2 31.8 22.2 48.8 31.7 19.2 10.5 4.63 cm2 808 702 595 501 433 366 299 257 226 195 164 360 306 252 201 174 150 123 213 168 136 113 93.1 162 145 127 110 90.4 76.4 66.3 58.7 65.2 56.1 47.1 38.3 29.2 Source: Tata Steel sections interactive 'blue book' version 5.5 ‐ reproduced with kind permision of Tata Steel www.kloecknerwestok.com 35 Cellular Beams CELLULAR BEAMS ULTRA SHALLOW FLOOR BEAM PLATE BEAMS ULT RA S HALLOW FLO OR B E AM THE PRODUCT OFFERING FROM KLOECKNER METALS UK | WESTOK ASD Westok Ltd previously trading as ASD Westok, now trades as Kloeckner Metals UK | Westok Contact the Kloeckner Westok design team for our free design service t: +44 (0)113 205 5270 | e: [email protected] Kloeckner Metals UK | Westok, Valley Farm Way, Stourton, Leeds LS10 1SE, UK t: +44 (0)113 205 5270 | f: +44 (0)113 254 1862 | e: [email protected] www.kloecknerwestok.com
© Copyright 2026 Paperzz