REFERENCES TABLE WITH CHARACTERISTICS OF TEMPERATURE CONTROLLERS CATALOGUE Reference 58x25,4 mm panel cut-out Interchangeable with traditional mechanic thermometers 70,5x28,5 mm panel cut-out up to 4 relays and real time clock 150x31 mm panel cut-out 4 keys for programming, 1 of lighting + 1 On / Off Dim. 90x70x58 mm for DIN rail up to 4 relays and 3 sensors 70,5x28,5 mm panel cut-out up to 4 relays, real time clock, buzzer and HACCP function Dim. 90x70x58 mm for DIN rail up to 4 relays, real time clock, buzzer and HACCP function Dim. 120x80x37 mm up to 3 relays and 2 sensors AKO-13012 AKO-13020 AKO-13023 AKO-13112 AKO-13120 AKO-13123 AKO-14012 AKO-14023 AKO-14031 AKO-14112 AKO-14123 AKO-14128 AKO-14129 AKO-14212 AKO-14223 AKO-14312 AKO-14323 AKO-14412 AKO-14423 AKO-10123 AKO-10223 AKO-10323 AKO-12123 AKO-12223 AKO-12323 AKO-12423 AKOTIM-11TE AKOTIM-11ATE AKOTIM-11ARTE AKOTIM-11ARTEB AKOTIM-12TE AKOTIM-12ATE AKOTIM-12ARTE AKOTIM-12ARTEB AKOTIM-13TE AKOTIM-13ATE AKOTIM-13ARTE AKOTIM-13ARTEB AKOTIM-21TE AKOTIM-21ATE AKOTIM-21ARTE AKOTIM-21ARTEB AKOTIM-22TE AKOTIM-22ATE AKOTIM-22ARTE AKOTIM-22ARTEB AKOTIM-23TE AKOTIM-23ATE AKOTIM-23ARTE AKOTIM-23ARTEB AKO-14602 AKO-14610 AKO-14632 SUPPLY RELAYS Thermom. Control Defrost Fans only 12 V 120 V 230 V 12 V 120 V 230 V 12 V 230 V 230 V 12 V 230 V 230 V 230 V 12 V 230 V 12 V 230 V 12 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V YES YES YES – – – YES YES YES – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – YES – – – – – 13 A 13 A 13 A – – – 16 A 16 A 16 A 18 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A – 16 A 16 A – – – – – – – – – – – – – 8A 8A 8A 8A 8A 8A – 8A 8A – 8A 8A 8A – – – – 8A 8A 8A 8A 8A 8A 8A 8A – – – – 8A 8A 8A 8A 8A 8A 8A 8A – – 8A Alarms Light – – – – – – – – – – – – – – – 6A 6A 6A 6A – – 8A – – 6A 6A – – – – – – – – 5A 5A 5A 5A – – – – – – – – 6A 6A 6A 6A – – 8A – – – – – – – – – – – – – – – – – 6A 6A – – – – – – 6A – 5A 5A 5A – 5A 5A 5A – 5A 5A 5A – 6A 6A 6A – 6A 6A 6A – 6A 6A 6A – – – DISPLAY digits SENSORS NTC up to 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 3 3 1 2 2 2 3 3 3 2 2 2 2 3 3 3 3 3 3 3 3 2 2 2 2 3 3 3 3 3 3 3 3 1 1 2 – – – – – – – – – – – – – – – – – – – 8A 8A 8A – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – INPUTS CONNECTOR CLOCK BUZZER to RS485 real time int. alarm digital – – – – – – – – – – – – – – – – – 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 – – – YES YES YES YES YES YES – – YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES – YES – – – – – – – – – – – – – – – – – – – – – YES YES – – – – – – – YES – – – YES – – – YES – – – YES – – – YES – – – YES – – – – – – – – – – – – – – – – – – – – YES YES – – – – – – – – – YES YES – – YES YES – – YES YES – – YES YES – – YES YES – – YES YES – – – On request, all AKOTIM models can be provided for 12 V, or 120 V supply. ON/OFF REGULATORS COMPRESSORS STATION CONTROLLING 4-20 mA input and 2 relays, for moisture, pressure, level … 4 stage for control of compressors or condensers - Reading configuration by pressure or temperature sensor. - Operations mode proportional and neutral zone. - Compressors in rotation by operation hours. - 6 digital inputs. - 4 compressors control relays + 1 alarm relay. - Connector for RS485 module to PC + parameters transfer. 70,5x28,5 mm panel cut-out CAT. Ref. Description AKO-14532 Regulator 230 V, with 2 relés 8 A, SPDT AKO-14534 Regulator 120 V, with 2 relés 8 A, SPDT AKO-80013 Humidity probe, 10 to 95%, with box and 4-20 mA converter 70,5x28,5 mm panel cut-out CAT. Ref. Description AKO-14540 Regulator 12 V, with 4 control stages + 1 alarm relay 351400151 REV.00 The two relay outputs allows controller configuration as: - Two independent stage. - Two related stage. - Neutral zone. - One stage + alarm. 2006 Av. Roquetes, 30-38 08812 Sant Pere de Ribes (Barcelona) Tel. (34) 938 142 700 Fax (34) 938 934 054 e-mail: [email protected] www.ako.com Apartado (P.O. Box), 5 08800 Vilanova i la Geltrú (Spain) AKO ELECTROMECÀNICA, S.A.L. Electronic controllers for indication, regulation and data acquisition COLD CONTROL Dealer: www.ako.com MENUS AND USUAL PARAMETERS DESCRIPTION MENUS DISPLAYING AKOTIM INFORMATION MENUS AND VALUES ALS Alarm menu (if any is activated) PARAMETERS Description Description Values AE Extern alarm of the digital input (If it is activated) rE REFRIGERATION control (compressor) AH The Sensor 1 temperature exceeds that programmed in A1 C0 Sensor 1 calibration (Offset) ºC/ºF AL The Sensor 1 temperature is lower than that programmed in A2 C1 Sensor 1 differential (Hysteresis) C/ºF of low-charge clock battery or non-programmed clock Ar Alarm C2 Set Point upper limit (It cannot be set above this value) ºC/ºF If the unit is over 36 h disconnected the clock needs to be programmed again C3 Set Point lower limit (It cannot be set below this value) ºC/ºF Ad Alarm activated if defrost ends by maximum time and A8 = 1 Compressor protection delay type: tid AKOTIM information menu (if programmed in P2 and not limited by L5) C4 0 = OFF/ON (From the last switch-off) 1 = ON (At switch-on) Hd1 Cycle 1 Information, last complete C5 Protection delay time (Value for the option selected in parameter C4) min Values of each cycle (flashing with concept) “COOL” (Compressor) relay status with faulty sensor 1: tHP Maximum temperature reached during refrigeration period ºC/ºF C6 0 = OFF 1 = ON 2 = OFF/ON (Programmed in C7 and C8) tLP Minimum temperature reached during refrigeration period ºC/ºF Pco Percentage time of the control relay (compressor) in ON % “COOL” (Compressor) relay time in ON in case of faulty sensor 1 C7 min nAC Number of control relay (compressor) connections per hour núm. (If C7 = 0 and C8 ≠ 0, the relay will always be OFF disconnected) PrE Percentage time within rating conditions % C8 “COOL” (Compressor) relay time in OFF in case of faulty sensor 1 min tFd Final defrost temperature ºC/ºF (If C8 = 0 and C7 ≠ 0, the relay will always be ON connected) tod Defrost duration time min. C9 “COOL” (Compressor) relay time in ON during continuos cycle (Uninterrup. operation) h tor Time to recover temperature after the defrost min. C10 Stop compressor if the door opens?: 0 = NO 1 = YES EP Level 3 exit dEF DEFROST control (electric heat / hot gas bypass) Hd2 Cycle 2 Information, prior to 1 Hd3 Cycle 3 Information, prior to 2 d0 Defrost frequency (Elapsed time between 2 starts) h Hd4 Cycle 4 Information, prior to 3 d1 Defrost maximum duration (If it does not end due to temperature, it will end due to time)min tot Time elapsed from the last defrost h Type of message during defrost: 0 = Display current temp. d2 toP Time to go for the next defrost h 1 = Display start temp. 2 = Display dF or dEF message EP Level 2 exit d3 Message maximum duration (Time added at the end of defrost) min Pb1 Sensor 1 value (S1-TEM of control) during 25 seconds Pb2 Sensor 2 value (S2-DEF of evaporator) during 25 seconds (if programmed, P4) d4 Defrost final temperature by sensor 2 (If programmed in P4) ºC/ºF In 2 relay versions, it operates if P6=0 Pb3 Sensor 3 value (S3 Independent of control) during 25 seconds (if programmed, P4) EP Level 1 exit Defrost start-up on equipment switch-on: d5 0 = NO, first defrost according to d0 1 = YES, first defrost according to d6 USUAL MESSAGES d6 Defrost start-up delay on equipment switch-on if d5 = 1 min dF It indicates defrosting is being carried out. In order to display “dF” or "dEF" Defrost type: 0 = Electric heat 1 = Hot gas by-pass dEF during defrosting, it is essential that parameter d2 is set to option 2 d7 To defrost by air in 2 relays, parameters F3 and P6 should be programmed AE Flashing with temperature - External alarm if it is programmed in digital inputs AES Flashing with temperature - Sever external alarm (Stop operations) d8 Time calculation between defrost periods: 0 = Total real time 1 = Compressor operation sum AH Flashing with temperature - Sensor 1 temp. exceeds the parameter programmed in A1 AL Flashing with temperature - Sensor 1 temp. is lower than parameter programmed in A2 d9 Drip time, compressor stop and FAN / R2 relay off when defrost ends min Ar Flashing with temperature - Low-charge clock battery or non-programmed clock alarm In 2 relay versions, R2 operates in any case of P6 E1 Sensor 1 failure (Open circuit, crossed, temp.> 110ºC or temp.<-55ºC) d10 Defrost 1 start-up time E2 Sensor 2 failure (Open circuit, crossed, temp.> 110ºC or temp.<-55ºC) d11 Defrost 2 start-up time E3 Sensor 3 failure (Open circuit, crossed, temp.> 110ºC or temp.<-55ºC) d12 Defrost 3 start-up time ES Incorrect sensor configuration (See P4, P8) d13 Defrost 4 start-up time - - Temperature > 99 ºC/ºF d14 Defrost 5 start-up time EE Memory failure d15 Defrost 6 start-up time PA Password request to enter programming parameters or SET POINT UP Flashing with temperature - Temp. out of AKOTIM rating conditions and increasing FAn FANS control (evaporator) (In 2 relay versions, R2 operates if P6 = 1 and sensor 2 connected) dn Flashing with temperature - Temp. out of AKOTIM rating conditions and decreasing F0 Fans stop temperature by sensor 2 ºC/ºF F1 Sensor differential ºC/ºF ADJUSTMENT AND CONFIGURATION F2 Stop fans, when compressor stops?: 0 = NO 1 = YES It should only be programmed or modified by personnel who are fully conversant with the equipment F3 Fans status during defrost: 0 = Off 1 = On operation and possibilities. F4 Start-up delay after defrost (Operates if it is higher than d9) min Set Point temperature F5 Stop fans if the door opens?: 0 = NO 1 = YES If P2=0 or L5=0 AL ALARMS control (visual, acoustic or relay) A0 A1 and A2 temperature alarms configuration: SIMULTANEOUSLY SIMULTANEOUSLY SIMULTANEOUSLY 0 = In related values to de Set Point 1 = In absolute values 5 Sec. A1 Maximum alarm in sensor 1 ºC/ºF A2 Minimum alarm in sensor 1 ºC/ºF A3 Temperature alarm delay in the start-up min A4 Temperature alarm delay from the end of a defrost min A5 Temp. alarm delay from the moment at which they should operate due to temp. min A6 Temperature alarm delay from digital input disabling of the door min PASSWORD CURRENT ENTER DISPLAY CURRENT NEW REQUEST TEMPERATURE PASSWORD PASSWORD SET POINT SET POINT A7 Temperature alarm delay from digital input enabling of the door min A8 Warning if defrost ends due to maximum time: 0 = NO 1 = YES The factory SET POINT default value is 0 ºC A9 Polarity configuration of alarm relay: - Press keys for at least 5 seconds to DISPLAY SET POINT. It displays the CURRENT SET POINT value and programming LED 0 = In the event of an alarm, relay ON 1 = In the event of an alarm, relay OFF starts flashing. A10 A1 and A2 alarms temperature differential (Some versions were regulated by F1) ºC/ºF - Press or keys to CHANGE SET POINT into the required value. inP DIGITAL INPUTS parameters (In some versions were in P9 and P10) - Press keys to ACCEPT THE NEW SET POINT. The display returns to the CURRENT TEMPERATURE display status and programming LED stops flashing. Digital input num. 1 configuration: When PA is displayed, PASSWORD programmed in L5 parameter should be entered to access the CURRENT SET POINT. 0 = Disabled 3 = Sever external alarm (Stop operations) i1C - Press keys. 0 will be displayed to ENTER PASSWORD. 1 = Door contact 4 = Remote defrost - Press or keys to CHANGE NUMBER and DISPLAY PASSWORD programmed. 2 = External alarm 5 = Change Set Point iS1 + it1 - Press keys to ACCEPT PASSWORD. The CURRENT SET POINT value will be displayed and it can be already modified. i1d Digital input num. 1 delay action min Menus, parameters and values configuration i1P Digital input num. 1 polarity 0 = Activation, when close contact 1 = Activation, when open contact CURRENT PASSWORD LEVEL 1 LEVEL 2 LEVEL 3 IF PROGRAMMED MENUS PARAMETERS VALUES TEMPERATURE i2C Digital input num. 2 configuration (The same as for input num. 1) i2d Digital input num. 2 delay action min SIMULTANEOUSLY SIMULTANEOUSLY SIMULTANEOUSLY SIMULTANEOUSLY SIMULTANEOUSLY SIMULTANEOUSLY 10 Sec. i2P Digital input num. 2 polarity 0 = Activation, when close contact 1 = Activation, when open contact SIMULTANEOUSLY iS1 Num. 1 secondary Set Point value, of COOL relay (Compressor) ºC/ºF it1 Num. 1 secondary Set Point length time min IF L5=0 CnF GENERAL STATUS parameters CURRENT NEW P0 Type of operation: 0 = Cold 1 = Heat VALUE VALUE P1 Delay of all functions on power supply switch on min Programmed parameters blocking or the Set Point: 0 = NO, unblocked or non allocation in AKOTIM disabled information P2 1 = YES, blocked or with L5 allocated in AKOTIM disabled information 2 = NO, unblocked or non allocation in AKOTIM enabled information PASSWORD ENTER DISPLAY 3 = YES, blocked or with L5 allocated in AKOTIM enabled information REQUEST PASSWORD PASSWORD Initial parameters: P3 EXIT (1 = YES, configure to “Def” and exit programming) MENU P4 Connected sensors: (1 = Sensor 1) (2 = Sensor 1 + 2) (3 = Sensor 1 + 2 + 3) (4 = Sensor 1 + 3) EXIT P5 Address for units with communication PROGRAMMING Relay 2 (F2) function in 2 relay versions: P6 0 = Defrost 1 = Fans control Menus - Press + keys simultaneously for at least 10 seconds. The programming LED will be flashing, we are in the programTemperature display mode: P7 ming LEVEL 1 MENUS and the first menu “rE” is displayed. 0 = Integers in ºC 1 = One decimal in ºC 2 = Integers in ºF 3 = One decimal in ºF - Press key to access the next menu and key to return to the previous one. P8 Sensor to be displayed: 1 = Sensor 1 2 = Sensor 2 3 = Sensor 3 - Pressing the key in the last menu EP, the controller returns to the CURRENT TEMPERATURE display status and programming LED will stop flashing. rtC REAL TIME CLOCK parameters When PA is displayed, PASSWORD programmed in L5 parameter should be entered to access programming LEVEL 1 MENUS. r1 Hours configuration h - Press keys. 0 will be displayed to ENTER PASSWORD. r2 Minutes configuration min - Press or keys to CHANGE NUMBER and DISPLAY PASSWORD programmed. - Press keys to ACCEPT PASSWORD. The first menu “rE” will be displayed. tid ACCESS AND INFORMATION control Parameters L1 Maximum temperature admitted during refrigeration period ºC/ºF Once you are in programming, proceed similar as for menus. In the units without menus you access directly to the parameters, L2 Minimum temperature admitted during refrigeration period ºC/ºF in such case they have only 2 levels. L3 Maximum partial time admitted out of rating conditions min Values L4 Maximum time admitted to recover temperature after a defrost min - To DISPLAY CURRENT VALUE of any parameter, select the required one and press keys. Once it is displayed, you can CHANGE VALUE pressing or keys. L5 Access password to parameters and information núm - Press the keys to ACCEPT THE NEW VALUE. The programming returns to LEVEL 2 PARAMETERS L6 Parameters transfer: (In some versions were in P11) 0 = Disabled 1 = Send 2 = Receive REMARK: If no key is pressed for 25 seconds in either of the previous steps, the controller will automatically return to the CURRENT TEMPERATURE display status without modifying any of the parameters values. PU Program version (Information) in some versions were in L7 or in P12 The menus, parameters, messages and adjustments in the list, are the more usual and generals, the particular ones for each model are described in the instructions included in each unit. Several models are different or do not have some menus, parameters or messages. ºC ACCEPT THE NEW CHANGE SET POINT CHANGE NUMBER DISPLAY SET POINT SET ACCEPT PASSWORD ºF ºC ºF ACCEPT PASSWORD CHANGE NUMBER ACCEPT THE NEW CHANGE VALUE DISPLAY VALUE ACCEPT SET
© Copyright 2025 Paperzz