Technical Release Note RN 14-02 Agility 3 V 3.84H Date: Originator: Product Line Component Software Release Distribution: March 11, 2014 RISCO Service Group Agility 3 Agility 3 Panel V 3.84H RISCO Customers System Details: A. Version: V3.84H B. Date: 11/03/2014 C. Checksum: 0xAA36 D. Software label: Agility_Wicomm_CPCP_V3.84H_11_03_14 E. Languages: Customer Default Text Language 0EU,0EN, 3SC, 0CN En SFI, 0FI Fi 0IT IT 0UK, 1UK UK 0SP, 1SP SP, CATALAN 0FR, 2FR, 3FR, 4FR, 5FR FR 0SE , 1SE SE , SE_1 0NL,1NL ,2NL,3NL,4NL NL 0CZ CZ 0DE DE 0PL, 2PL PL 0AR SP 0BR, 0PR PR 0DK, 1DK, 2DK DK, DK_1 0NO, 1NO NO, NO_1 0TH EN(TH) 0AU AU 8SP, 8PR, 8PE, 8AR, For prosegure 8CL, 8UR, 8CO, 8BR, 8PY, 8CN F. Components version Component Software Version Checksum PIC V 1.79 0xC08D GSM V 2.22 0xC6D1 IPC V 2.10 0x2C2D Voice V 1.26 0XDF3A ALTERA Agility V 61 NA ALTERA Wicomm V 74 NA DTR V 1.39 0x07ED RF Stamp V 1.22A NA G. Keypad compatibility Software version V4.15 and above DB version V4/18 and above 1. Introduction RISCO Group has released a new firmware version for the Agility 3 panel, with improvements. 2. New Features & Changes 2.1 Integration with CLOUD a. b. c. d. Partitions - Adding support for partitions Zone Label - Support for zone labels update via CLOUD Code Length - Adding support in working with Code Length of 6 Digits Channels connection to Cloud - New channels definition for connecting to Cloud in addition to ‘IP Only’ and ‘GSM Only’ options. Add internal backup mechanisem: i. IP / GPRS ii. GPRS / IP e. f. g. h. i. j. k. Note: In this case the ‘MS Call all’ and ‘FM Call all’ is disabled. MS and FM Call All – This function not available when system defined connect to Cloud with internal Backup (IP / GPRS or GPRS / IP). ARM & Disarm Via Cloud and APP - Adding option to disable ARM and Disarm functions in Cloud and Applications by panel definition. Pre Arm Image - Pre Arm image sent to Cloud with fixed number. Timeout for panel back to Cloud from Back up Mode - Backup mode timeout changed from 10 minutes to 3 minutes (need to default the system in order to take effect). I'm Alive Message - I am alive message is running also when panel is in installation Pass Code - Changing confirmation logic in panel to WEB Interface so Panel will let WEB login without User code only with hide special code. SIA IP - Adding the panel Serial ID to SIA IP transmitting in the VTAG part. Cancel alarm report – Adding support in cancel alarm report from panel to cloud. In this way, the operator will be aware that the system has been disarmed after alarm. 2.2 CID and Translations Updating Translations and CID Defaults Values: a. Updated Defaults and Translation for Italy b. Updated Defaults for Thailand c. Updated Defaults for New Zeeland d. Update Defaults for the next CID: 0SE, 2NO, 1DK, DD243 and EN50131 for UK, UK, 4FR. 2.3 Default Year - Change default year to 2014 – when panel reboots it will present the year as 2014. 2.4 Silent Upgrade - Remote upgrade process by panel will be silence: a. Beep follow Resets will be off. b. Power-on Announcement message is off in case of power-on follow upgrade 2.5 Default Voice - When initialize panel the Default Voice that will hear in system is English Voice in case that it include in the Voice Module. 2.6 MS Voice GSM – MS VIA GSM Voice was enhanced to achive better performance from the GSP provider network (Integration withNEW GSM Module version 2.16B and up). 2.7 Support In WL Curtain Detector 1W and 2W a. Parameters – Support with WL Curtain Parameters. b. RF Serial Numbers - Low temperature detector serial numbers were changed to Curtain detector. Note: Low temperature detector RF Serial Number were removed from system DB. 2.8 PIR Camera a. PIR Camera Images Folder - When panel is working in NON Cloud connection, the panel transfers the images events to the same as the path in the images server. b. PIR Camera Video Frequency – PIR Camera video frequency is set by panel via DTR software layer follow CID definitions. c. Images Transfer – Improving Images transfer time to Cloud / HTTP by changing mechanism. DTR (a component in the RF Head) add ability to read images from camera in parallel to transfer process to Cloud Server or HTTP Server. d. Recover Scenarios i. Reset Camera By Panel - Adding support in reset Camera by panel in case of lost communication with Video Chanel. ii. Arming Camera via Security – In case that camera not armed by panel via Video channel, panel will arm it via Security Chanel in the next camera Supervision transmitting. e. Adding support in Camera Trigger: Add the ability to activate PIR camera in the system follow additional events other than its own inspection as follow: i. PIR Camera>Advanced> Camera Trigger 1. Follow System • Duress Y/N 2. Follow Partition (Relates to the PIR camera partitions) 2.1 Panic Y/N 2.2 Fire Y/N 2.3 Emergency /Medical Y/N 2.4 Intruder Y/N 2.5 Tamper Y/N 2.6 No activity Y/N 2.7 Confirmed alarm Y/N 3. Follow Zone (Alarm + Tamper) 3.1 Zone 01 3.2 Zone 02 3.3 Zone xx Y/N (List on zones in the system) Notes: 1. Follow partition: Refers to the partitions of the current PIR camera. There is no need to select which partition to assign. A partition that is no part of the PIR camera cannot be used for that camera. 2. Follow zone: Need to show list of available zone in the system Each zone can be assigned with Y/N 3. PIR camera can follow more than a single selection (It can follow system duress, and Follow partition panic and fire and Follow zones 1, 2, 3). 4. Snapshot parameters - When an event is trigger the camera, the camera will take snapshot as it defined in the PIR Camera itself. 2.9 Transmitting events to MS a. SIA IP: i. Adding support in transmit events to MS via SIA IP Protocol in parallel to Cloud. ii. Adding the panel Serial ID to SIA IP transmitting in the Vtag part accordingly to definition in panel. b. SIA: i. Adding support for partition ID to MS Events when panel transmit over SIA protocol via PSTN Only according to panel definition. 2.10 RF Levels - Adjust the RF Panel RSSI level and Accessories Com Test results to be similar levels as AgilityV2 system. 2.11 WLKP2W and SLIM Keypad - Adding support in Supervision mechanism to accordingly to definition and follow RX timer. 2.12 X73MB - Adding support for the X73M (B) Magnets with shutter functionality 2.13 SMS in Parallel to GPRS - support for Panel sending and receiving incoming SMS in parallel to panel communication with Cloud VIA GPRS. 2.14 Battery Saving - In case panel include full system setup: IP Module, GSM and Fast modem, when the panel lost his AC Power and the panel defined to work with standards, the panel managed the voltage for saving battery to work up to 12H. 2.15 Delete Accessory by menu - Adding new option for delete RF accessory by WLKP2W. 2.16 Cancel Report - Adding cancel report notification follow Disarm by Keyfob operation in case that system CID is for Prossegure CID – (8XX). 3. Updated modules 3.1 GSM - V2.22 a. In case that the GSM stays in TX not ready for 30 minutes the panel will close the connection b. Improving communication mechanism between GSM and Cinterion module with recover scenarios in Communication faults states. c. Support in SMS in parallel to GPRS communication. 3.2 IP Module V2.10 The IP Module new version is for solving recovering lost IP Address follow few Routers types. 3.3 WLKP2W a. Adding support in all new panels features to all languages. b. Adding support in SV (Supervision) mechanism accordingly to panel TX timer. 3.4 Slim Keypad V1.08 a. Adding support for SV (Supervision) mechanism accordingly to panel TX timer. b. Improving the Wake up mechanism 3.5 Voice V1.26 The voice module resolves loosing voice problems (stop answering in SPI). 3.6 Portuguese Audio Replace the word "Esta" with another word accordingly to Procegure customer request 3.7 DTR 1.39 a. Fault in Upgrade Stamp - In case of fail during Upgrade Stamp the DTR not stuck and skip the upgrade. b. Video RF multi frequency support - Adding Support for multi Video frequency support by Panel definition accordingly to CID. 3.8 Stamp 1.22 Improving al RF Communication and care in fail and recovery scenarios when working with Video Chanel. 3.9 PIC 1.79 Support in Silent Upgrade 4. Improvements 4.1 Improving SIA IP Protocol (On top of item # 2.8 - Transmitting events to MS) 4.2 Improving Integration with Risco Cloud (item #2.1 - Integration with CLOUD) 4.3 Get Snapshot Via SMS - Panel should reject Get Snapshot Request from User without common Partition with PIR Camera Partitions 4.4 MS SIA listen in - Fixing MS SIA Listen IN 5. Fixes 1 2 3 4 5 Header GSM - Reset during Upgrade (Not power Up) - In case that GSM not answer to panel after reset not after power up, The Panel should not auto remove the GSM from allocation - Panel should relate to it as exist no comm. until it answer CS - Zones - X73F - Universal Shutter - Input2- The panel should save the inputs definitions depending detector Serial ID - Serial ID 1 = Input 1and Serial ID 2 use Input 2 - for ignoring from overriding input 1 parameter correct value Cloud - Parallel communication - MS - SIA IP - When panel connected to Cloud and it defined reporting MS In parallel to Cloud, The panel not transmit events to MS in case it defined as SIA IP other MS Types transmitting well GSM PIN Code - Upgrade: The upgrade process stuck in the burning GSM step as the Panel with PIN code in GSM Failed in Upgrade process between versions that Panel should set to default MS - Listen in function - SIA - Listen In follow MS Code report LF - When panel send LF to MS the panel not react to It and not open a Listen In timer window for getting Listen IN - as results there is no ability to perform Listen in a 6 7 8 9 10 11 12 13 14 15 Header Arm Pre Warning=Y - There is no automatic Arming by 45 minutes despite the fact that perform Disarm during countdown of 4.25 minutes with valid User Code from WLKP2W (not from WLKF1W or WLKF2W) PIR Camera - It is required that panel will Relate partition status with camera communication, and it will be a condition for arm. In case of disconnection between panel &PIR Camera the arming will failed (Must by Italy) Entry Time of Exit Open / Entry 2 zone is wrongly - It work as Ex/En 1 time instead of Ex/En 2 time Area = Y - FM - The FM Message on alarmed common zone when zone gaurd because of one partition send to all the Zone's partition instead to one partition only WLKP2W - Codes/Tags - Authority Level - Cleaner - The Cleaner Code is a temporary code, which is to be immediately deleted from the system as soon as it is used to set. Smoke detector - Fire Alarms - When a smoke detector is transmit a fire alarm, The panel generates and two events - a regular alarm (BA) and a fire alarm (FA) instead just Fire Alarm Stamp - RF - Calibration - The Calibration result has growth to 70 - 90 follow enlarging the Zones Com Test Silent Programming - Remote upgrade - Requested that panel will silent the PIC Buzzer Beeps in Panel reset and Audio Voice Message in Reset after Upgrade process (Function available from Upgrade Panel from version 3.84 and UP) Cloud - GSM - When system is connecting to Cloud via GPRS, when performing the remote upgrade via GPRS activating by panel or CS, the upgrade not performed until GSM not Busy (Disconnect from Cloud for any reason) Digital Voice - After panel power up, if we change panel text to language that is not valid in the voice, the voice language is changed to the 1st language in the voice package instead of not changing at all 6. Limitations: 6.1 IP Module new version limitation: The New IP Module network restores will perform 4 minutes after trouble event even in case that the IP Network cable connected to system before this time. The delay is required for over on some Routers types after restart. 6.2 New IP module resolves several communication problems with specific routers such as BTrouter, MicroTech. Fritzbox router communication problems are under investigation. 7. Upgrade Process The upgrade firmware can be performed via the remote upgrade server of RISCO. For any queries or additional information regarding this issue contact Guy Amrani from RISCO Service Group. Notice This document contains proprietary and confidential material of Risco Group, Ltd. Any unauthorized reproduction, use, or disclosure of this material, or any part thereof, is strictly prohibited. This document is solely for the use of Risco Group, Ltd. employees and authorized Risco Group, Ltd. customers. The material furnished in this document is believed to be accurate and reliable. However, no responsibility is assumed Risco Group, Ltd. for the use of this material. Risco Group, Ltd. reserves the right to make changes to the material at any time and without notice. Copyright © 2010 Risco Group, Ltd. All rights reserved. Products and company names mentioned herein may be trademarks and/or registered trademarks of their respective companies.
© Copyright 2026 Paperzz