■ High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves EIC-H-1007-0 EH SERIES High response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVDT. Direct type ELDFG-01/03 and two stage type ELDFHG-04/06 (which use the ELDFG-01 as a pilot) are available. ■ Direct Operated Type Directional and Flow Control Valves This product can be interchanged with the simplified servo valve to perform position control and pressure control. Compared to nozzle flapper type of servo valve, this product has excellent contamination-related problems. ■ Specification Model Numbers Description Max. Operating Pressure Kgf/cm2 Max. Tank Line Pres. Kgf/cm2 ELDFG-01 315 210 10 : 10 20 : 20 35 : 35 Rated Flow L/min. [Valve ∆P : 150 Kgf/cm2] Hysteresis Repeatability 40 : 40 80 : 80 0.5% or less 0.5% or less 100 % 100 30 ms 0% 38 ms Phase -90 Degree Frequency Response (0 ±25 %V) 48 Hz 3C2, 3C40: 35 Hz 3C2P: 38 Hz [20 C] Max. 2.5 A 3.9 Ω Max. 3A 3Ω Kg. Max. 25 W 3.2 Max. 27 W 7.5 0 Approx. Mass Graphic Symbol 3C2, 3C40: 36 Hz 3C2P: 41 Hz 52 Hz Gain -3dB Rated Current Coil Resistance Power Input 3C2, 3C40: 29 ms 3C2P: 25 ms 3C2, 3C40: 26 ms 3C2P: 23 ms ■ A SOL a SOL b T Flow Rate 100 80 Rated Flow 40 20 100 200 T SOL b 3C2 3C2P 3C2 3C2P A B A B P T P T SOL b SOL a SOL b H 3C40 B A P T 35 L/min. 20 L/min. 10 L/min. 300 Kgf/cm² Valves Pressure Difference ∆P Rated Flow 150 100 80 L/min. 40 L/min. 50 0 SOL a SOL b SOL b P T L/min. 200 60 P Control Type 3 Port Valve L/min. L/min. 0 A SOL a SOL b P B SOL a SOL b Control Type 4 Port Valve 100 200 300 Kgf/cm² Valves Pressure Difference ∆P 200 Flow Rate T A ELDFG-03 Control Type 3 Port Valve Flow Rate P SOL a T 3C40 ELDFG-01 B P SOL a See “Valve Pres. Difference vs. Flow Rate” below characteristics for the appropriate range. A B SOL a Range of Flow Control Control Type 4 Port Valve Metre-Out Control A Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 0 Step Response (Typical Rating) ■ ELDFG-03 150 Rated Flow 100 80 L/min. 40 L/min. 50 0 100 200 300 Kgf/cm² Valves Pressure Difference ∆P * Valve pressure difference “ P” is reference by follows. In addition, “P”, “A”, “B”, “T” are pressure of each port. 4 Port Valve: P = [(P-A) + (B-T)] or [(P-B) + (A-T)] 3 Port Valve: P = (P-A) + (A-T) EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 1 EH SERIES ■ Model Number Designation F- ELDF G -01 Special Seals Series Number Type of Mounting Valve Size F: Special Seals For Phosphate Ester Type Fluid (Omit if not required) ELDF: Proportional ElectroHydraulic Direct Operated Type Directional and Flow Control Valves ■ 01 -35 Rated Flow L/min. -3C2 Spool *1 10:10 20:20 35:35 03 40:40 80:80 -10 Design Number 10 3C2 G: Sub-Plate Mounting -XY Direction of Flow 3C40 XY: Metreout Metre-in 10 Attachment Mounting Bolts Model number Socket Head Cap Screw Qty. ELDFG-01 M5x45Lg. 4 Bolt Kit Model Number BKELDFG-01-10 ELDFG-03 M6x35Lg. 4 BKELDFG-03-10 ■ Sub-Plate Valve Model No. ELDFG-01 ELDFG-03 Sub Plate Model No. Pipe Connection Thd. DSGM-01-3080 DSGM-01X-3080 DSGM-01Y-3080 DSGM-03-2180 1/8 1/4 3/8 3/8 DSGM-03X-2180 1/2 DSGM-03Y-2180 3/4 Mass Kg. 0.8 3 4.7 Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. The Sub-plates are those for 1/8 and 3/8 solenoid operated directional valves. For dimensions, see Page. No. 11 of both EIC-E-1001 and EIC-E-1002. ■ Applicable Power Amplifiers For stable performance, it is recommended that Yuken’s applicable power amplifiers be used (for details see page 16 of EIC-H-1008). Valve Model Numbers ※ 3C2 3C40 ELDFG-01-※-3C2P 3C2 ELDFG-03-※3C40 ELDFG-03-※-3C2P ELDFG-01- - 2 Power Amplifier Model Numbers AMN-L-01-1-10 AMN-L-01-3-2P-10 AMB-EL-03-1-10 AMB-EL-03-2P-1-10 EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve EH SERIES ■ ELDFG-01- - -XY-10/1090 5.5 Dia. x Thru. 9.5 Dia. Spotface 4 Places Pressure Port "P" 40.5 Cylinder Port "A" 0.75 The direction can be altered to every 90 degreee angles. Air Vent 3 Hex. 3 Places 32.5 31 1: SIG Air Vent 3 Hex. 3 Places 1,2: Power Supply Tank Port "T" Cylinder Port "B" 148.5 186.5 133 39 82 39 37 44 SOL b Cable Departure Cable Applicable: Outside Dia. 4.5-7 mm Conductor Area 0.5-0.75 mm² 38 58 2: CAR 3: COM 3: Earth Terminal SOL a 25 95 Cable Departure Cable Applicable: Outside Dia. 8-10 mm Conductor Area 0.75-1.5 mm² 48 27.5 Air Vent 2.5 Hex. 11 Manual Actuator 6 Dia. Mounting Surface (O-Rings Furnished) 65 335 Note : For valve mounting surface dimensions see the dimensional drawing of sub-plates page 11 od EIC-E-1001. - -XY-10/1090 7 Dia. x Thru. 10.5 Dia. Spotface 4 Places Air Vent 2.5 Hex. Cylinder Port "A" 54 Pressure Port "P" Cylinder Port "B" The direction can be altered to every 90 degree angles. 46 56 2: CAR 1: SIG 3: COM Tank Port "TA" * Tank Port "TB" * 3: Earth Terminal Cable Departue Cable Applicable: Outside Dia. 4.5-7 mm Conductor Area ... 0.5-0.75 mm² 192 138.1 39 91 70 27.5 37 SOL a 21 36 44 SOL b 16 Mounting Surface (O-Rings Furnished) H Air Vent 3 Hex. 2 Places 1, 2: Power Supply Terminal Cable Departue Cable Applicable: Outside Dia. 8-10 mm Conductor Area ... 0.75-1.5 mm² 173 72 37 DIMENSIONS IN MILLIMETRES Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve ELDFG-01- 86 120 ■ Manual Actuator 6 Dia. 365 Note : For valve mounting surface dimensions see the dimensional drawing of sub-plates page 11 od EIC-E-1002. EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 3 EH SERIES Input Voltage vs. Flow Rate -3C2/3C40 L/min. Flow Rate ELDFG-01- ELDFG-01- -3C2P L/min. 40 30 A B 20 P T 35 L/min. 20 L/min. 10 L/min. VDC Input Voltage 10 -10 -8 -4 -10 -8 4 10L/min. A B -20 P T -30 35 L/min. P T -30 -40 40 L/min. 100 80 VDC Input Voltage -10 -8 60 40 20 0 P T 40 L/min. 8 10 4 Input Voltage VDC -40 -60 -80 -100 P T -4 80 L/min. A B 40 L/min. 80 L/min. AB -40 P T -60 8 10 Input Voltage VDC -20 -80 L/min. L/min. -4 -1 -2 -0.5 A B -1.0 P T -1.5 -3 0 -10 -8 Input Voltage VDC 0 4 AB 8 P T 6 4 2 0 8 10 0 -4 -0.5 -1 A B -2 -1.0 P T -1.5 -3 -3C2P VDC mm Spool St. 10 Spool St. Spool St. Sensor Monitor Voltage 1 ELDFG-03- VDC mm VDC 0.5 -3C2/3C40 3.0 2.5 2.0 1.5 1.0 VDC Input Voltage 0.5 -10 -8 -4 0 0 -0.5 -2 -1.0 -4 -1.5 A B -6 -2.0 -8 P T -2.5 -3.0 -10 2 P T VDC Input Voltage Sensor Monitor Voltage ELDFG-03- 1.0 -10 -8 0 -2 -4 -6 -8 -10 -12 VDC -4 AB P T Sensor Monitor Voltage Input Voltage VDC 0 4 8 10 0 Sensor Monitor Voltage 0 -10 -8 1 3 A B 3.0 2.5 2.0 1.5 1.0 0.5 0 A B P T -0.5 -1.0 -1.5 -2.0 -2.5 -3.0 EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 12 10 8 6 4 2 0 Sensor Monitor Voltage 0.5 mm 1.5 Spool St. 2 P T Sensor Monitor Voltage 1.0 -3C2P Spool St. 3 A B ELDFG-01- VDC Spool St. mm 1.5 Spool St. Sensor Monitor Voltage -3C2/3C40 Sensor Monitor Voltage Input Voltage vs. Spool St. ELDFG-01VDC 4 -20 8 10 Input Voltage VDC L/min. ELDFG-03- -3C2P L/min. Spool St. ■ A B Flow Rate Flow Rate 80 L/min. 10 L/min. 10 L/min. 80 L/min. 4 20 L/min. 0 35 L/min. P T A B P T -4 20 L/min. A B 40 L/min. 20 35 L/min. 4 100 -20 A B -10 L/min. ELDFG-03- -3C2/3C40 L/min. 60 40 VDC Input Voltage 20 -4 -10 -8 0 30 8 10 Input Voltage VDC -40 80 40 VDC Input Voltage 10 0 -10 20 L/min. Flow Rate ■ EH SERIES Step Response Viscosity : 30 mm2/s The values were measured on independent valves. They vary by circuit. ELDFHG-01-35-3C2/3C40 Supply Pressure : 20 Kgf/cm Flow Rate : 35 L/min. AB ELDFHG-01-35-3C2P 2 AB P T Step Signal P T -100% 0 35 L/min. 100% Travel of Spool Step Signal 0 -100% 0 Supply Pressure : 20 Kgf/cm2 Flow Rate : 35 L/min. 0 Travel of Spool 0 0 AB P T P T 20 ms 100% Step Signal 20 ms A B 0 0 35 L/min. 100% 0 20 ms Travel of Spool 0 20 ms 0 Travel of Spool 0 0 100% 35 L/min. 0 -100% Step Signal 0 35 L/min. 0 -100% ELDFG-03-80-3C2/3C40 ELDFG-03-80-3C2P Supply Pressure : 40 Kgf/cm Flow Rate : 80 L/min. AB 2 Supply Pressure : 40 Kgf/cm2 Flow Rate : 80 L/min. AB P T P T 20 ms Travel of Spool 0 -100% Step Signal 20 ms 0 0 Travel of Spool 0 0 Step Signal 0 -100% -100% A B Travel of Spool ■ 80 L/min. 0 -100% AB P T Step Signal 0 80 L/min. P T +100% 0 80 L/min. 100% 0 20 ms 0 Step Signal 0 Travel of Spool +100% 0 80 L/min. 100% 0 0 H 0 20 ms Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve ■ Frequency Response Input Signal : 0±25 %V Primary Pressure : 140 Kgf/cm2 Viscosity : 30 mm2/s ELDFG-03-80-3C2/3C40 -5 -100 -150 -200 -10 -15 -20 5 7 10 20 Gain Phase 50 70100 0 0 -50 -5 -100 -150 2 5 7 10 20 Gain -10 -15 -20 Frequency (Hz) 50 70100 0 0 -50 -5 -100 Phase -150 Gain (dB) -50 2 Gain (dB) 0 Frequency (Hz) Phase (deg.) 0 Gain (dB) Phase (deg.) Frequency ELDFG-03-80-3C2P Phase (deg.) ELDFHG-01-35-3C2/3C40/3C2P 2 5 7 10 20 (Hz) 50 70100 Gain -10 Phase -15 -20 EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 5 EH SERIES ■ Spare Parts List List of Seals Name of Parts Part Numbers Qty. ELDFG-01- ELDFG-03- ELDFG-01- ELDFG-03- O-Ring Fastner Seal SO-NB-P18 SG-FCF-4 SO-NB-A128 SG-FCF-4 2 2 2 2 Fastner Seal O-Ring TK280152-0 SO-NB-P9 TK280152-0 SO-NB-A014 1 4 1 4 List of Seal Kits Model Numbers Seal Kit Number ELDFG-01ELDFG-03- KS-ELDFG-01-10 KS-ELDFG-03-10 ■ Solenoid Assembly Valve Model Number Solenoid Assy. ELDFG-01-※-※-XY-10 E318-Y06M2-14-5007 E318-Y06M2-14-L-5007 E324-Y12M2-28-10 E324-Y12M2-28-L-10 ELDFG-03-※-※-XY-10 6 Qty. 1 1 EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve EH SERIES Two Stage Type Directional and Flow Control Valves Specification Model Numbers ELDFHG-04 Description Max. Operating Pres. Kgf/cm2 ELDFHG-06 350: 350 500: 500 350: 350 500: 500 350 “T” Port : 350 “P” Port : 210 500 “T” Port : 250 “P” Port : 210 350 Rated Flow Valve L/min. Pres. Difference: 15 Kgf/cm2 280 Proof Pressure at Return Port *1 (External Drain) Kgf/cm2 “T” Port : 315 “Y” Port : 210 Proof Pressure at Return Port (Internal Drain) Kgf/cm2 2 Pilot Pressure * Kgf/cm2 210 15 - 315 350 : 16 L/min. or more 16 L/min. or more 500 : 19 L/min. or more Pilot Flow *3 Null Leakage *4 Ps = 140 Kgf/cm2 Pp = 140 Kgf/cm2 3C2: 3 L/min. or less 3C40: 4 L/min. or less 3C2P: 10 L/min. or less Step Response (Typical Rating) (0 100%) Pp = 140 Kgf/cm2 Frequency Response (0±25% V, Phase) Pp = 140 Kgf/cm2 Water - Proofness 350: 15 ms 500 : 18 ms 350: 66Hz 500: 39 Hz 13 ms 46 Hz (-90 degrees) IP64 Operating Temperature Type -15 to +60 °C Spool Type 3C2: 3C2P: Graphic Symbols 3C40: (Zero Rap) Approximate Spool Stroke to Stops Main Spool End Area ±5 mm cm2 7.1 Rated Current Coil Resistance 350: ±5 mm 500: ±5 mm 8 Approx. Mass T B P T Y B P T SOL a SOL b A A Y SOL b Internal Pilot / Internal Drain Type A B P T 350: 18 500: 19 10 SOL a *1 Return pressure should be less than the actual supply pressure. *2 Pilot pressure should be between 15 Kgf/cm2 and 35 Kgf/cm2 , and should exceed 60% of the actual supply pressure to main valve. *3 Pilot flow is calculated with the above step response time at pilot pressure 140 Kgf/cm2. *4 Added up leakage of main and pilot spools are stated. ■ P Internal Pilot / External Drain Type 3.9 Ω Kg. B SOL a Max. 2.5 A 20 °C A SOL a SOL b X External Pilot / External Drain Type SOL b X External Pilot / Internal Drain Type H Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve ■ ■ Model Number Designation F- ELDFH G Special Seals Series Number F: Special Seals for Phosphate Ester Type Fluids (Omit if not required) ELDFH: High Response (Two Stage) Type Proportional Electro-Hydraulic Directional and Flow Control Valves Type of Mounting -04 -280 -3C2P -XY -E T -10 Valve Size Rated Flow L/min. Spool Type*1 Direction of Flow Pilot Connection Drain Connection Design Number 04 280 : 280 None: Internal Pilot None: Internal Drain E: External Pilot T: External Drain 3C2 G: Sub-Plate Mounting 3C40 3C2P 06 350 : 350 500 : 500 XY: Meter-In Meter-Out 10 (Zero Lap) EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 7 EH SERIES ■ Applicable Power Amplifiers For stable performance, it is recommended that Yuken’s applicable power amplifiers be used (for details see page 16 of EIC-H-1008). ■ Attachment Installation condition Model Numbers Socket Head Cap Screw Qty. M6x55Lg. 2 ELDFHG-04 ELDFHG-06 M10x60Lg. 4 M12x85Lg. 6 ELDFHG-04-280- -XY- - -10 Connector The direction can be altered to every 90 degree angles. Pressure Port "P" Pilot Pressure Port "X" Tank Port "T" 341 77 101.6 10.5 Dia. x Thru. 17.5 Dia. Spotface 4 Places 35 DIMENSIONS IN MILLIMETRES 1,2: Power Supply Terminal 3: Earth Terminal Pilot Drain Port "Y" Cable Departure Cylinder Port "B" Cable Applicable: Outside Dia. 4.5-7 mm Conductor Area 0.5-0.75 mm² 6.4 Dia. x Thru. 11 Dia. Spotface Cable Departure 1: SIG 2 Places Cable Applicable: Cylinder Port "A" Air Vent 3 Hex. 2 Places 3: COM ... Outside Dia. 8-10 mm Conductor Area ... 0.75-1.5 mm² 2: CAR Position Sensor for Pilot Spool SOL a Air Vent 2.5 Hex. SOL b Position Sensor for Main Spool 13.5 1: SIG 130 3: CAR 8 Locating Pins 3 Dia. 2 Places 2: COM EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 4 38 46 45 82 136 Air Vent 3 Hex. 3 Places 180 194 206 50 10.5 69.9 91 34 Mounting Surface (O-Rings Furnished) EH SERIES - -XY- - -10 Connector The direction can be altered to every 90 degree angles. 55 53.2 DIMENSIONS IN MILLIMETRES Pressure Port "P" Cable Departure Cable Applicable: Outside Dia. ... 8-10 mm Conductor Area ... 0.75-1.5 mm² 92.1 Pilot Drain Port "Y" 46 13 118 13.5 Dia. x Thru. 20 Dia. Spotface 6 Places Tank Port "T" 350: 371 500: 375 130.2 1,2: Power Supply Terminal 3: Earth Terminal 77 Pilot Pressure Port "X" Cylinder Port "A" Cylinder Port "B" Air Vent 3 Hex. 3 Places Cable Departure Cable Applicable: Outside Dia. ... 4.5-7 mm Conductor Area ... 0.5-0.75 mm² 1: SIG 2: CAR 3: COM Position Sensor for Pilot spool SOL a Air Vent 2.5 Hex. Soc. SOL b 52 64 96 162 206 220 Air Vent 3 Hex. 3 Places 232 ELDFHG-06- Position Sensor for main spool Mounting 6 Dia. Surface (O-Rings Locating Pins 2 Places Furnished) 1: SIG 156 2: COM 3: CAR Dimensions of valve mounting surface ELDFHG-06 101.6 76.7 50 34 T 19.1 17.5 16 57.1 X 20 Dia. 4 Places (Port "P", "T", "A", "B") 65.8 88.1 3.6 Dia. x 20 Deep 2 Places Model Numbers “C” Thd. “D” Thd. “E” mm “F” mm ELDFHG-04 M6 M10 12 17 ELDFHG-06 ━ ━ ━ ━ "H" Thd. x "J" Deep 6 Places P Y 92.1 74.6 18.3 71.4 69.8 55.6 14.2 1.6 "C" Thd. x "E" Deep 2 Places "D" Thd. x "F" Deep 4 Places 29.4 A B 17.5 29.5 100.8 “H” Thd. “J” mm M12 24 ━ H Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve ELDFHG-04 7 Dia. x 8 Deep 2 Places 11 Dia. 2 Places (Port "X", "Y") 130.2 112.7 94.5 77 53.2 6 Dia. 2 Places (Port "X", "Y") 96.9 Prepare a mounting surface as shown to the below. Also finish it finely. 73.1 ■ 6 11.5 ELDFG-06-350 : 27 Dia. 4 Places ELDFHG-06-500 : 32 Dia. 4 Places (Port "P", "T", "A", "B") ━ EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 9 EH SERIES ■ 2 Input Voltage vs Flow Rate Valve Pres. Diff. : 10 Kgf/cm : 30 mm2/s Viscosity ELDFHG-04 ELDFHG-06 L/min. 400 Flow Rate AB 300 PT 200 Input Voltage VDC 100 700 600 AB 400 P T Input Voltage VDC 200 -12 -10 -8 -6 -4 -2 -12 -10 -8 -6 -4 -2 -200 AB -300 P T Flow Rate 0 2 4 6 8 10 12 -100 Input Voltage VDC -400 AB 500 L/min. -600 -700 PT L/min. Input Voltage VDC L/min. Viscosity : 30 mm /s ELDFHG-04 ELDFHG-06 L/min. 1800 1600 1400 1200 1000 800 600 400 200 2800 ELDFHG-06-500 Flow Rate Flow Rate 6 8 10 12 2 Load Flow Characteristics L/min. 350 L/min. 0 2 4 -200 350 L/min. -400 ■ 500 L/min. Flow Rate Flow Rate L/min. 2400 2000 1600 1200 ELDFHG-06-350 800 0 50 100 150 200 250 300 Kgf/cm² 350 400 Load Press. Diff. 0 50 100 150 200 250 300 350 Kgf/cm² Load Press. Diff. ■ Step Response (Example) Viscosity : 30 mm2/s ELDFHG-04 AB AB Step Signal +100% 0 0 0 10 ms 0 Travel of Spool 0 AB Step Signal Travel of Spool 10 ms 0 Travel of Spool 0 Step Signal PT -100% 0 0 Travel of Spool 0 0 10 ms 0 0 AB PT 0 Step Signal Travel of Spool 0 -100% 0 0 10 ms PT 0 -100% 0 0 0 10 ms -100% ■ +100% 0 +100% AB 0 PT +100% +100% Travel of Spool Step Signal +100% 0 ELDFHG-06-500 AB PT PT Step Signal ELDFHG-06-350 10 ms -100% -100% Frequency Response Input Signal : 0±25 % Hydraulic Circuit : Port A/B Closed Supply and Pilot Pressure : 140 Kgf/cm2 Viscosity : 30 mm2/s 10 80 120 160 200 20 Phase Gain Frequency Hz 50 70 100 0 0 40 -4 -8 80 120 160 200 2 5 7 10 20 Phase Gain ELDFHG-06-500 Frequency Hz 50 70 100 0 0 40 -4 -8 80 120 160 200 2 Gain (dB) -4 -8 5 7 10 Gain (dB) 40 2 Phase (deg.) 0 Gain (dB) Phase (deg.) Frequency 0 ELDFHG-06-350 Phase (deg.) ELDFHG-04 EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 5 7 10 20 Phase Gain Hz 50 70 100 EH SERIES ■ Spare Parts List List of Seals for ELDFHG-04 Name of Part Numbers Qty. Parts O-Ring SO-NB-P39 1 O-Ring SO-NB-P22 4 O-Ring O-Ring O-Ring SO-NB-P9 SO-NB-A029 SO-NB-A012 2 1 2 List of Seals for ELDFHG-06 Name of Parts Part Numbers ELDFHG-06-350- ELDFHG-06-500- Qty. O-Ring O-Ring SO-NB-P40 SO-NB-A135 SO-NB-P14 1 4 O-Ring O-Ring SO-NB-P10 SO-NB-A123 SO-NB-A126 2 1 O-Ring SO-NB-A030 2 SO-NB-A135 List of Seal Kits ELDFHG-04 ELDFHG-06-350ELDFHG-06-500- Seal Kit Number KS-ELDFHG-04-10 KS-ELDFHG-06-350-10 KS-ELDFHG-06-500-10 H Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve Model Numbers EH Series Proportional Electro-Hydraulic Direct Operated Type Directional and Flow Control Valve 11
© Copyright 2026 Paperzz