Validation of diagnosis capabilities of a pocket echoscopic device’s for heart investigations Nazim Alimazighi, 1 MD , Patricia Reant, MD 1 PhD Marina Dijos, 1 MD , Amira Zaroui, 1 MD , Aude Mignot, 1 MD , Marianne Lafitte, 1 MD , Xavier Pillois, MD1, Raymond Roudaut, MD1, Anthony DeMaria, MD PhD2, and Stephane Lafitte, MD PhD1 1 Hopital Cardiologique Haut-Leveque, CHU de Bordeaux, Universite Bordeaux II, CIC-0005, Bordeaux-Pessac, France; 2 University of California at San Diego (UCSD), CA, USA INTRODUCTION Recently, progressive electronic and computer miniaturization has succeeded in creating an ultrasmall echocardiograph which can be fully contained in the pocket of a laboratory coat. We hypothesized that, based on greyscale imaging and color Doppler capabilities, this new pocket ultrasound device (PUD) (Figure 1) could accurately record diagnostic findings. Ultrasound windows quality Left ventricular (LV) function OBJECTIVES This study was designed to investigate the feasibility and comparative accuracy of this ultrasmall device to evaluate the cardiac structure and function by ultrasound. good normal average moderate EF>60% 35%≤EF<60% Segmental LV function LV morphology LV thickness METHODS A total of 100 patients referred for conventional clinical indications underwent a standard echocardiographic examination performed by a physician specialized in echocardiography. Subsequently, a second physician blinded to the results obtained by the first observer performed an evaluation using the PUD (Vscan, GE Medical Systems) on the same patients. Study end-points were echocardiographic window quality, left ventricular (LV) morphology, function, hypertrophy, right ventricular (RV), atrial and vena caval morphologies, aortic and mitral valvular disorders, and pericardial structure. Results were assessed using a scale consisting of 3 grades (Table 1). Concordances were calculated using the Cohen-Kappa test. WT<12mm insufficient severe dysfunction EF<35% normal normal abnormal dilated EDD<58mm EDD≥58mm normal hypertrophy asym. hypertrophy normal normal normal normal normal lack lack normal dilated dilated dilated abnormal abnormal slight slight slight normal normal dilated dilated Ø ≤ 25mm Ø > 25mm WT≥12mm Right ventricular (RV) Left atrium (LA) Right atrium (RA) Aortic valve Mitral valve Aortic regurgitation Mitral regurgitation Pericardium effusion Vena cava Abdominal Aorta moderate severe moderate severe moderate severe dilated + no resp. var. (EF: LV ejection fraction, EDD: LV end-diastolic diameter, WT: LV Wall thickness) Table 1: List of parameters obtained in the evaluation RESULTS Table 2 presents concordances between PUD and standard echocardiographic machines. Concordance in image quality proved good with a kappa coefficient (K) of 0.71. LV function and morphology were normal in 68% and 81% of cases, respectively. Concordances between systems were excellent for these parameters (K 0.91 and 0.96). (Figure 2) Concordance for LV hypertrophy was good (K 0.74). Fifteen patients exhibited RV dilation by full feature exam, which was detected by PUD in 93% of cases. Concordances for mitral regurgitation grades were 0.90, 0.95, and 1.00, respectively. Of our patients, 18 and 19 presented pericardial effusion when using standard and PUD and respectively. Figure 3 depicts concordances for quantitative abdominal aorta measurements. 20 y = 0,90x + 6,04 70 r = 0,84 p<0,001 15 2 11,96 10 5 Differences VSCAN EF 60 50 40 30 0 0 10 20 30 40 50 60 70 80 -5 -10 20 -14,06 -15 10 -20 0 0 20 40 60 80 -25 Linéaire (TTE EF = f(VSCAN EF)) 50 40 Bias = -1,05 4 3,775 3 30 20 2 1 0 -1 0 10 Lim of agreement (95%) Figure 2 : Correlation (Figure 2a) and Bland-Altman analysis (Figure 2b) between qualitative ejection fraction (EF) obtained with conventional TTE and PUD 20 30 40 50 60 -2 10 -3 -3,042 -4 0 20 40 60 -5 Means Aorta Diameter TTE (mm) Means Differences 5 y = 0,96x + 0,29 r2 = 0,94 p<0,001 0 TTE EF TTE EF = f(VSCAN EF) Aorta Diameter VSCAN (mm) 80 6 60 Differences 90 Figure 1 : Vscan pocket ultrasound device TTE = f(VSCAN) Linéaire (TTE = f(VSCAN)) Differences Bias = 0,3663 Lim of agreement (95%) Figure 3 : Correlation (Figure 3a) and Bland-Altman analysis (Figure 3b) between quantitative abdominal aorta measurements obtained with conventional TTE and PUD Table 2: Results of the concordance analysis between conventional echocardiographic evaluation and PUD, and between the two observers using PUD. Results for each diagnostic target are displayed with the concordance value and the Kappa coefficient parameters CONCLUSION This new pocket sized ultrasound device enabled scanning examinations which showed good concordance of diagnostic capability to standard full feature echocardiographic instruments. This study validated the smallest pocket echoscopic device VSCAN, first ultraportable TTE with 2D black and white and color Doppler mode, which is easy to use and transport, providing accurate measurements when operated by an experienced physician who wishes to complement patient evaluation in clinical practice.
© Copyright 2026 Paperzz