Page 1 of 3 IMPORTANT: SIGN MUST BE REGISTERED BY THE INSTALLER TO BE OPERATIONAL Handset Software Version: C03.03 Installer Instructions Release: 2/16/2015 PN: INS0303 1a Gather the information and complete the product registration form. 1b Locate the handset and plug it into a 120V outlet for a minimum of 1 hour before calling for registration. You need to be at the sign when you call. 1h Note: If you have multiple signs each sign will need to be registered individually. The sign being registered will need to be turned on while all other signs must be off. This process will need repeated for each sign. If the handset displays POS: Disabled The handset POS functionality has not been enabled. If you do not wish to enable this functionality press the key twice and proceed to step 1l. To purchase this functionality you will need to call 614-388-8866 option #3 After the POS function has been purchased, you will be shipped a special POS cable and instructions. Upon reciept of the cable you will need to return to the Installer Setup Mode 5 screen by repeating steps 1c to 1h. To start the activation press the key while the cursor is on the POS function 1c Press the 1d Press the then press the 1i Enter the activation code then press key. 1j Use the and keys to select the appropriate POS protocol. key twice to display the home screen. (Both screens are valid home screens) Each Sign and Handset must be registered to work. Call Able with Serial Numbers to get Registration # Unleaded Premium x.xxx x.xxx Then press 1k Use the and keys to select the appropriate POS Baudrate Gilbarco: 1200 Verifone: 9600 Dresser Wayne: 38400 Able Protocol: 1200 Radiant - NCR: 19200 Installer Setup Mode 1 Access Code: 4159 Then press 1e Call 614-388-8866 option #1 for service to get your permanent registration code. Using the keypad enter the registration code then press the key to save. For testing or temporary use you can use the code: 9999999999 If you use the temporary code and the sign looses power the sign will also loose communication with the handset and need to be registered again. If the sign registration number does not appear on this screen power cycle the sign (the sign only broadcast its registration number for 5 minutes) If you entered the temporary code 9999999999 on the previous screen and the site ID is 999999 then select Yes using the key then press If you received your permanent registration number and entered the number while on the Installer Setup Mode 2 screen the number shown in the Site ID, verified by the Able Technician will reflect the registration was entered correctly. If the SiteID is correct select the Yes by pressing the key then the key. If the ID is incorrect select No then the key and you will return to step 1e. 1m Example: 2.95 109 = 4 digits 1n 1o Press to save and proceed. Setup Modes The following screens send values to signs Please register all signs before continuing. 1p Installer Setup Mode 5 POS: Gilbarco TS-1000 POS Baudrate: XXXX Sign Count: X Digit Count: 4 Decimal Point: X.XXX Uses 9/10's: Yes Installer Setup Mode 5 POS: Gilbarco TS-1000 POS Baudrate: XXXX Sign Count: X Digit Count: 4 Decimal Point: X.XXX Uses 9/10's: Yes Installer Setup Mode 5 POS: Gilbarco TS-1000 XXXX Baud Sign Count: X Digit Count: 4 Decimal Point: X.XXX Uses 9/10's: Yes to save and proceed. If you want the priceline to turn off if a predetermined number of LED's fail (not supported on all signs) Use the and keys to select Yes or No. Then press Installer Setup Mode 5 POS: Gilbarco TS-1000 POS Baudrate: XXXX Sign Count: X Digit Count: X Decimal Point: X.XXX Uses 9/10's: Yes to save and proceed. If the sign has stacked 9/10 use the and keys to select Yes or No. Then press 1g Installer Setup Mode 5 POS: Gilbarco TS-1000 POS Baudrate: XXXX Sign Count: X Digit Count: X Decimal Point: X.XXX Uses 9/10's: Yes to save and proceed. Use the and key to select the location of the decimal point. Then press Installer Setup Mode 5 POS: Gilbarco TS-1000 POS Baudrate: XXXX Sign Count: X Digit Count: X Decimal Point: X.XXX Uses 9/10's: Yes to save and proceed. Use the keypad to select the number of digits in a grade. Then press Installer Setup Mode 5 POS: Disabled XXXX Baud Sign Count: X Digit Count: X Decimal Point: X.XXX Uses 9/10's: Yes to save and proceed. Use the keypad to select the number of signs. The handset supports up to 4 signs. Note: Generally a sign consist of multiple grades/pricelines and is two sided. 1l Then press 1f to save and proceed. Defaults: key then type in 4159 key. Installer Setup Mode 5 POS: Disabled XXXX Baud Sign Count: X Digit Count: X Decimal Point: X.XXX Uses 9/10's: Yes to save and proceed. Installer Setup Mode 6 Error Blanking: No Cash/Credit: Off Sign Lite Kit: No Use POS Names: No PATH: Internal Modem Page 2 of 3 Handset Software Version: C03.03 Installer Instructions Release: 2/16/2015 1q To activate the Able Price Alternator use the the appropriate setting. Options Off = Off 4 - 24 Seconds between alternating prices Multi = Select this on alternators that display more messages than just Cash & Credit Cash = Displays Cash price only Credit = Displays Credit price only Then press keys to select Installer Setup Mode 6 Error Blanking: No Cash/Credit: Off Sign Lite Kit: No Use POS Names: No PATH: Internal Modem To activate the Sign Light Kit use the and the appropriate setting. Sign Light Kit: Installed inside the sign the Sign Light Kit allows the handset to remotely turn off and on the interior lighting of the sign as defined in step 1w. No = No Kit Installed Yes = Kit is Installed Then press To activate the POS Names Function use the the appropriate setting. POS Names Function: Used with the NCR protocol this allows the POS to name the grades displayed on the handset No = disables this function Yes = enables this function Then press Installer Setup Mode 6 Error Blanking: No Cash/Credit: Off Sign Lite Kit: No Use POS Names: No PATH: Internal Modem and to save and proceed. If the Sign Light Kit was installed and activated in step 1r. Use the the and keys to select the appropriate settings. Options Customer Setup Mode Day Brightness: 99 Night Brightness: 20 Sign Lights: PhotoEye PhotoEye = The photoeye on the priceline will automatically turn the sign on when its dark and off when its light Timed = Requires you to define the on and off time On = Turns the lights on Off = Turns the lights off Then press to save and proceed. 1x If the Sign Lights setting was set to Timed The additional setting Lights On & Lights Off will become available. Time is displayed in military format. Use the keypad, and keys to set the time then press 1y Set the date and time using the keypad, and keys then press keys to select Installer Setup Mode 6 Error Blanking: No Cash/Credit: Off Sign Lite Kit: No Use POS Names: No PATH: Internal Modem Customer Setup Mode Day Brightness: 99 Night Brightness: 20 Sign Lights: Internal Modem: Uses the handsets own antenna and internal circuitry for communication Customer Setup Mode Day Brightness: 99 Night Brightness: 20 Sign Lights: Timed Lights On: 00:00 Lights Off: 00:00 0000-01-19 03:31:41 Then press year month day hour minute second Installer Setup Mode 6 Error Blanking: No Cash/Credit: Off Sign Lite Kit: No Use POS Names: No PATH: Internal Modem Aercomm Modem: Press the key once. Disables the internal modem. Used for external long range radios. 0000-01-19 03:31:41 Customer Setup Mode Day Brightness: 99 Night Brightness: 20 Sign Lights: Timed Lights On: 16:00 Lights Off: 07:00 0000-01-19 03:31:41 to save and proceed. Use the and keys to select the appropriate method of communication. 1z Press 2a This screen displays the wireless signal strength. to proceed. Communication Errors to save and proceed. Use the and keys to navigate through the pricelines To enable or disable a priceline/grade align the arrow " " with the priceline then press the x key. Use the key to select a priceline and the following predefined keys to define it 1 Unleaded 6 Plus Installer Setup Mode 8 2 Diesel 7 V-Power ----- CASH PRICES ----A: Unleaded 3 Regular 8 Super-Unleaded -DisabledB: -DisabledC: 4 Mid-Grade 9 Ultra -DisabledD: 5 Premium 0 __________ Cash Or use the and Then press 1w keys to select Use the and keys to navigate through the settings and the number keys to change them. (default day/night brightness shown) 0000-01-19 03:31:41 to save and proceed. 1s 1u 1v to save and proceed. 1r 1t and and keys to select an individual digit and the keys to modify the digit. Then press key bad good sign number If you encounter poor signal strength try moving the handset to another location. Locating the handset in the line of sight with the sign is the best practice. To prevent decreased signal strength avoid locating the handset behind metal surfaces and make sure the antenna does not come in contact with metal. Radio waves have the ability to bend around and bounce off objects (buildings, trucks, cars etc.) Radio waves can also pass through most common building products (glass, wood, tile, masonry, drywall). Monitor the signal strength for a few minutes non stationary objects may move potentially decreasing or increasing signal strength. to save and proceed. If the Able Price Alternator is enabled the handset the will support 4 grades 2 prices per grade (otherwise 8 grades 1 price per grade). Example: (Alternator Enabled) Shortcut to get to this screen: Press the key 3 times then the Range Test Mode 1 2 3 4 5 6 7 8 9 1 Installer Setup Mode 8 ----- CASH PRICES ----A: Unleaded Cash B: Premium Cash -DisabledC: -DisabledD: Installer Setup Mode 9 ----- CASH PRICES ----A: Unleaded Credit B: Premium Credit -DisabledC: -DisabledD: Then press 2b to save and proceed. To start diagnostics press the key that corresponds to the sign to be tested. (in this example you would press 1 or 2) You can press the key at any time to exit diagnostics Sign Diagnostics Keys 1 - Sign 1 2 - Sign 2 Page 3 of 3 Handset Software Version: C03.03 Installer Instructions Release: 2/16/2015 2c (1 minute timeout) The sign will turn on all the LED's in all the pricelines. 2h Inspect all the pricelines on both sides of the sign If any of the LED's are out document the position (grade, digit, row, column and quantity) The sign will now display the jumper settings and voltage applied to each priceline. Verify the settings are correct. L.b_ = nighttime dim mode L.C_ = nighttime dim mode L.d_ = nighttime dim mode L.E_ = nighttime dim mode L.F_ = nighttime dim mode Note: If in dim mode during the day contact customer support. Grade of Fuel A=top priceline B=next priceline down C=next priceline down continuing to grade H (15 second timeout) USE A FLASH LIGHT TO SIMULATE DAYTIME MODE SIGN SHOULD CHANGE STATE IN 30 SECONDS Side of Sign pricelines on same side of sign will have same numeric value If not then the sign is wired incorrectly. (15 second timeout) Number in hexadecimal L.A_ = daytime bright mode L.9_ = daytime bright mode L.8_ = daytime bright mode L.7_ = daytime bright mode L.6_ = daytime bright mode Press the same key as you did in step 1w to continue. 2d The sign will now display the photoeye diagnostics u=Unleaded red LED's (15V DC) d=Diesel green LED's (19V DC) Generic Priceline Control Card (PCC) located on the back side of the priceline photoeye (covered with green film) NOTE: IF IT DOES NOT PASS FUNCTIONAL TEST DO NOT SHIP CONTACT AAT SUPPORT Press the same key as you did in step 1w to continue. 2i The sign will cycle through the 6 digit site ID, displaying 2 digits at. a time. to priceline Data lines from master control card and to other pricelines Press the same key as you did in step 1w to continue. Site ID 2e The sign will now display the priceline firmware version. (Earlier firmware versions may not support all functions shown in this document) Latest Multisegment firmware or Seven Segment firmware All grades, both sides must be the same. Press the same key as you did in step 1w to continue. 2f The sign will now display the master controller firmware version. (15 second timeout) Latest MCC2 firmware: Press the same key as you did in step 1w to continue. 2g The sign will now display the temperature inside the sign in Celsius. (Note: the F diagnostic will display shortly before (15 second timeout) automatically switching to the T diagnostic) If the sign is hotter than t.60 the sign will appear dimmer. If the sign is hotter than t.70 additional venting is required. Press the same key as you did in step 1w to continue. Note: If a priceline digit is faulting an E code will also apear on this screen The error will only show on the pricelines that have a faulting digit. Digit with error (1=dollar, 2=dime, 3=penny, 4=9/10) Number of Errors 2j Upon completion of the diagnostics. If the Able Price Alternator is activated you will need to power cycle the sign to initiate the function. Plug the handset back into a 120v outlet. This will keep the handset charged and in the case the POS is activated the handset will be in constant communication with the sign. Locate the handset away from water and excessive heat or cold.
© Copyright 2026 Paperzz