Technical information for cylindrical curved glass Cylindrical curved float glass Cylindrical curved insulating glass Min. radius 50 mm 100 mm Max. angle 180° 150° Max. dimensions girth x height/width 3210 x 6000 * girth x height/width 3210 x 6000 * * The table shows the max. theoretically possible dimensions. Sizes can vary depending on used glass (thickness/function) and shape. Min. dimensions on request on request Max. pitch 1200 mm moreover on request 1200 mm moreover on request Max. weight 2000 kg 2000 kg Glass thickness 2–19 mm 4–34 mm moreover on request Bendable glass types* • Low-iron extra-clear glass, e.g. Diamant (Saint-Gobain), Optiwhite (Pilkington) • Tinted float glass (e.g. Parsol) • Anti-reflective glass e.g. Amiran®, Conturan® (Schott AG) • Mirror with chrome coating MIRASTAR® (Saint-Gobain) • Self-cleaning glass: Bioclean® (Saint-Gobain) • Cast glass and rolled glass (with some limitations) • Antique sheet glass • Wired glass • Screen printed glass (screen print on the inside) • Decoration glass • Frosted glass • Mattfinished glass (partial or completely) • Etched and sandblasted glass, also with CLEAR-SHIELD® • Bevelled glass • Enamelled float glass • Shatter-resistant with security window films • Partial or complete coverage with coloured glass painting. Powder coating is also available. see float glass The following glass types can be used for the production of curved double glazed units: • Solar control glass with hard coatings, e.g. ANTELIO, COOL-LITE® ST, STOPSOL, Sunergy, Silverstar Sunstop T or with combined solar and thermal control coatings e.g. COOL-LITE®SKN*, SunGuard® HS, SunGuard® HP, SunGuard® Solar • Heat protection glass Planitherm Ultra N II (soft coating), K-Glass (hard coating) • Acoustic protection glass compositions with "Stadip Silence" (sound insulation interlayer) are also available • Safety termal insulating glass in connection with heat protection, acoustic protection, sun protection and special laminated safety glass combinations with different resistance class according to DIN EN 356 *Notice: The values listed under Technical Data are only for guidance. The geometrical parameters of a curved glass pane, the min./max. values of the parameters as well as the requested glass assembly are closely linked and influence the corresponding limiting values of each other. Limits of size, dimensions, possible glass thickness and bending angles are determined according to individual arrangement and thorough technical examination. Restrictions in the form of shape must be expected. Dimensional tolerances For all curved glass products manufactured in our company, the general tolerance and conditions in accordance to "Guideline for thermal bend architectural glass products ", BF-datasheet 009/2011 from Bundesverband Flachglas e.V. and the "Guideline to Assess the Visible Quality of Glass in Buildings." are valid (unless otherwise agreed in writing). Technical feasibility Remark: technical modifications and errors excepted! • Cavity width range: preferably 6–14 mm, max. 20 mm • Insulating glass gas filling: Argon, Krypton • Production with Super Spacer® TriSeal • Warm-edge-technology, thereby excellence features in thermal isolation • Glass compositions are depending on geometry • Special insulating glass for stepped-units with UVresistant edge seal • The closer radius, smaller dimensions, the higher load on the edge seal because bending stiffness (less pumpable) • Performance data of glass compositions (light transmission, light reflection, energy transmission, energy reflection, UV-transmission and g-value) can only be mentioned according to values of comparable planar glass compositions (calculation with CALUMEN software) At the moment we are able to achieve a Ug-Value up to 1,0 W/m2 K for double-glazed units in accordance with DIN EN 673. With an curved triple-glazed unit, even a Ug-value up to 0,5 W/m2 K in accordance with DIN EN 673 is possible. We produce insulating glass units in accordance with EN 1279. For more information of marking products please contact us. Site 1/2 Technical information for cylindrical curved glass Cylindrical curved laminated glass Cylindrical curved toughened glass/heat-strengthened glass Min. radius 100 mm 550 mm depending on thickness, size, shape, and function (coating etc.), moreover on request Max. angle 150° 90°, moreover on request Max. dimensions girth x height/width 3210 x 6000 mm * ≥ 550 mm min. radius** ≥ 1100 mm ≥ 1300 mm ≥ 2000 mm girth x height/width 1200 mm 2000 mm* 2400 mm 4200 mm* 2850 mm 5500 mm* 4300 mm 2800 mm* * The table shows the max. theoretically possible dimensions. The sizes can vary depending on used glass (thickness and function) and the shape. **Depending on thickness, size, shape and function (coating) etc. Min. dimensions on request 300 x 400 mm Max. pitch 1200 mm, moreover on request 400 mm Max. weight 2000 kg 2000 kg Glass thickness maximum glass size thickness according to clients request Toughened glass 4–12 mm (15 and 19 mm on request) Heat strengthened glass 4 –10 mm Bendable glass types* see float glass • Clear- and tinted float glass (Parsol) • Low-iron extra-clear glass • Anti-reflective glass • Satined glass • Patterned glass • Screen-printed and enamelled glass (print only on concave side) • Heat protection glass (hard coating) K-Glass • Heat protection glass (soft coating) SGG Planitherm Ultra N II • Solar control glass (hard coating): SGG Antelio®, Resistance class approved safety features GLABIE laminated glass (related to planar superstructures PVB-AF-Trosifol) • impact-resistance (P1A–P5A)** • manuel attack-resistance (P6B–P8B)** • bullet resistance (BR1S–BR4S)** • explosion resistance • laminated glass with built in alarm-wire • coloured laminated glass is also available • SentryGlas®interlayer ** in reference to safety glazing standard DIN EN 356 Laminated glass with SI foil achieve good sound insulation performance data, even as monolithic composition e.g. laminated glass 44.2 = 37 dB With laminated glass and 0,76 mm PVB foil edge shift be expected max. 1,5 mm/meter edge (max. 5 mm) • Solar control combined with thermal insulation in one coating: Range: SGG COOL-LITE® SKN, SunGuard® HS, SunGuard® HP, SunGuard® Solar *Notice: The values listed under Technical Data are only for guidance. The geometrical parameters of a curved glass pane, the min./max. values of the parameters as well as the requested glass assembly are closely linked and influence the corresponding limiting values of each other. Limits of size, dimensions, possible glass thickness and bending angles are determined according to individual arrangement and thorough technical examination. Restrictions in the form of shape must be expected. Dimensional tolerances For all curved glass products manufactured in our company, the general tolerance and conditions in accordance to "Guideline for thermal bend architectural glass products ", BF-datasheet 009/2011 from Bundesverband Flachglas e.V. and the "Guideline to Assess the Visible Quality of Glass in Buildings." are valid (unless otherwise agreed in writing). Technical feasibility For our standard laminated glass as safety glass, we use clear foil with a thickness of 0.76 mm. Also multiple layers of Polyvinylbutyral (PVB)-foil and glass are available. On request, we can also process coloured laminated safety glass. • Heat-soak tested fully tempered (toughened) safety glass • Fire resistant glass (in cooperation) • Alarm Securit® • Thermovit – heatable glass It's possible to manufacture curved tempered glass, curved tempered glass with heat-soak test and curved heat-strengthened glass into laminated safety glass and insulated glass to meet every safety and security specification. Site 2/2 05.2016 • Remark: technical modifications and errors excepted!
© Copyright 2025 Paperzz