C L I N I C A L chem istry RE AG ENTS www.sekisuidiagnostics.com CO2 measurements are used as an aid in the diagnosis and treatment of an acid-base imbalance. METHOD: ENZYMATIC (PHOSPHOENOLPYRUVATE CARBOXYLASE); RATE features: FOR THE QUANTITATIVE MEASUREMENT OF CARBON DIOXIDE 4 One part stable liquid reagent, 5X concentrate Carbon Dioxide (CO2) L3K® - C 4 Applicable to multiple chemistry platforms 4 Serum and plasma are acceptable sample types Sekisui’s Carbon Dioxide (CO2) L3K® - Concentrate Reagent uses an enzymatic procedure which is easy to use and applicable to routine laboratory instrumentation. It is intended for the measurement of carbon dioxide in serum and plasma. benefits: 4 Accommodates most testing requirements regardless of laboratory size or workload 4 Laboratory flexibility 4 Flexible sample types to meet different laboratory needs o rdering inf o r m at i o n C on f i g u r at ion cata log n u m ber C A R B O N D I O X I DE ( C o2 ) L 3 K ® - C R1 3 X 60 mL 288-36 C A RB O N D I O X I DE ( Co 2 ) L 3 K ® - C R1 1 X 1000 mL 288-80 D C - C A L C A L I BR AT OR 5 X 3 mL SE -035 D C -TR O L LEV E L 1 10 X 5 mL SM -052 D C - TRO L LEV E L 2 10 X 5 mL SM -056 C 0 2 STA N D AR D * 1 X 15 mL DIAGNOSTI C S The Americas international Sekisui Diagnostics, LLC 4 Hartwell Place Lexington, MA 02421 Phone: 800 332 1042 Fax: 800 762 6311 Email: [email protected] Sekisui Diagnostics (UK) Limited 50 Gibson Drive Kings Hill, West Malling, Kent, ME19 4AF, UK Phone: +44 (0) 1732 220022 Fax: +44 (0) 1732 220024 Email: [email protected] ©2013 Sekisui Diagnostics, LLC – All rights reserved. 9217 *Not available in Canada and Europe 80-7457-00-02 03/13 C L I N I C A L chem istry RE AG ENTS Carbon Dioxide L3K®- C www.sekisuidiagnostics.com Perf orman ce C h a r ac t e r i s t ics Pre cis ion Within-Run: <1.3% (serum) Within-Run: <1.9% (plasma) Total Precision: <4.6% Accur ac y SERUM Slope: 1.014 Intercept: 0.50 mmol/L (0.50 mEq/L) Correlation Coefficient: 0.9944 PLASMA Slope: 0.973 The performance of this method (y) was compared with the performance Intercept: 0.89 mmol/L (0.89 mEq/L) of another carbon dioxide method (x) on a Hitachi 717 analyzer. Correlation Coefficient: 0.9907 ® Line a r i t y 1.0 - 50.0 mmol/L (1.0 - 50.0 mEq/L) N o s igni f ican t int e r f e r ence s up to l e ve l s indicat e d Hemoglobin: 1000 mg/dL (155 μmol/L) Ascorbic Acid: 3000 μg/dL (170 μmol/L) Bilirubin: 40 mg/dL (684 μmol/L) Intralipid: 1000 mg/dL (3000 mg/dL [34 mmol/L] Simulated Triglycerides) Ref e r enc e rang e (1) 22 - 29 mmol/L (22 - 29 mEq/L) (1) Burtis, C.A., Ashwood, E.R.T., (Editors), Tietz Textbook of Clinical Chemistry, 3rd Edition, W.B. Saunders Company, Philadelphia (1999). NOTES: DIAGNOSTI C S The Americas international Sekisui Diagnostics, LLC 4 Hartwell Place Lexington, MA 02421 Phone: 800 332 1042 Fax: 800 762 6311 Email: [email protected] Sekisui Diagnostics (UK) Limited 50 Gibson Drive Kings Hill, West Malling, Kent, ME19 4AF, UK Phone: +44 (0) 1732 220022 Fax: +44 (0) 1732 220024 Email: [email protected] ©2013 Sekisui Diagnostics, LLC – All rights reserved.
© Copyright 2026 Paperzz