ETHIL ACETATE in urine by GC-FID Code GC01510 BIOCHEMISTRY The ethyl acetate at room temperature is presented as a volatile liquid, colorless and with a pleasant fruity smell, a compound is highly flammable and irritating. Is widely used as a solvent for paints, resins and glues and it is relatively less toxic than other chlorinated solvents. The proposed method determines the ethyl acetate inject in GC / FID a rate of urine sample previously treated in an appropriate solvent. EUREKA srl – LAB DIVISION VAT N° 01547310423 E-mail:[email protected] www.eurekaone.com Head Quarter: Via Enrico Fermi 25 60033 Chiaravalle (AN) ITALY Tel. +39 071 7450790 Fax + 39 071 7496579 This product fulfills all the requirements of Directive 98/79/EC on in vitro diagnostic medical devices (IVD). The declaration of conformity is available upon request. Release N° 001 Ethyl Acetate in urine by GC/FID 1 March 2011 TECHNICAL FEATURES Principle of the Method : This method allows to determine the urinary ethyl acetate by GC-FID. The ethyl acetate is first diluted and then is directly injected into GC. aliquot of urine sample previously treated in an appropriate solvent. Recovery: >95% Sensitivity: 30 mg/l Dynamic Range of the Method: 30 – 15.000 mg/l Reference Values: n.d. Components of the kit : All Reagents are ready to use and stable 3 years at ≤ 20°C. Reagent A – Stabilization Solution, 1 x 150 ml Reagent B – Test Solution / Chemical Standard, 1 x 5 ml Store at 2-8 °C Minimum Instrumental equipment required: GC/FID Operational Computer Optional Equipment: Autosampler Urine Collection Procedure: After work shift, collect 10 ml of urine in a suitable test tube. Stable 4 weeks at –20 °C. 2 IMPORTANT: USE ONLY IN GLASS TUBE EVERY STEP - DO NOT USE PLASTIC TUBES PREANALYTICAL PROCEDURE Preparation of Test Solution. Dispense in a 10ml glass tube: • • 450 µl of Reagent A – Stabilization Solution 50 µl of Reagent B – Test Solution Vortex for 10 sec. The samples are injected directly transferring the supernatant into vials for GC Inject 2 µl of solution into gas chromatograph GC. Verify that the Test solution has retention time similar to fig. 1. If the Test is all right you can start with the analytical procedure; if not, check the functionality of the analytical system. ANALYTICAL PROCEDURE STEP 1: Preparation of Calibration Standard at 450 mg/l Dispense in a glass tube of 10ml: • • 200 µl of Water 200 µl of Reagent B – Test Solution Mix at Vortex Dispense in a glass tube: • • 900 µl of Urine without Ethyl Acetate 100 µl of Test Solution previously diluted IMPORTANT: This Calibration Standard Solution is prepared from time to time To verify that the urine is effectively free from Ethyl Acetate, to prepare a Blank: • • 900 µl of Urine 100 µl of H2O HPLC grade If the Blank urine presented the peak of Ethyl Acetate, proceed to identify the quantitative difference between the areas / heights of the peaks of Ethyl Acetate in urine enriched and blank. Release N° 001 Ethyl Acetate in urine by GC/FID 3 March 2011 Dispense in a glass tube: Calibration Standard 100 µl Calibration Standard Control Sample Blenck Reagent A – Stabilization Solution Control Sample Blanck 100 µl 100 µl 900 µl 900 µl 900 µl 100 µl 900 µl Close vials hermetically • Centrifuge 2 minutes at 5000 rpm • Put all the surnatant in vials for GC-FID. Inject 2 µl in GC-FID. Prepare work list and start the serie according to the system’s specifications. Release N° 001 Ethyl Acetate in urine by GC/FID 4 March 2011 ETHYL ACETATE - Warnings REAGENT B : TEST SOLUTION / CHEMICAL STANDARD ETHYL ACETATE 9000 mg/l SET OF GAS-CROMATOGRAPH: • • • • • • • Factor Four VF- 624 ms Column 30 m x 0,32 mm x 1,80 µm (conditioned) Injector Temperature 280 °C Splitting Ratio: In: OFF 0’ ON:10 Temperature 40 °C x 3,9 minutes + 20 °C/min till up 150 °C x 0 minutes + 50 °C/min till up 280 °C x 0 minutes (run 12 minutes) Column Flow: 1 ml/min Detector Temperature (FID): 240 °C Range (sensitivity) Detector: 12 (max) CONDITIONING OF FACTOR FOUR VF-624 MS COLUMN: Follow the manufacturer prescription. CLEANING OF THE COLUMN ANF SYRINGE: Before injection wash the syringe with ACETONE. Disconnect the detector. Keep the column at the highest temperature for the recommended time. (See the manufacturer ’s instructions) OPERATIONAL COMPUTER PARAMETERS: IN CONFORMITY WITH THE SPECIFICATION OF OPERATIONAL COMPUTER SOFTWARE 5 ETHYL ACETATE IN URINE (Reference Chromatograms) µV 145.000 10.000 9.800 µV 9.600 9.400 9.200 9.000 8.800 8.600 8.400 8.200 8.000 7.800 7.600 7.400 7.200 7.000 6.800 6.600 6.400 6.200 6.000 5.800 5.600 5.400 5.200 5.000 4.800 4.600 4.400 4.200 4.000 3.800 3.600 3.400 3.200 3.000 2.800 2.600 2.400 2.200 2.000 1.800 1.600 1.400 1.200 1.000 800 600 400 200 0 -200 08 T Acet ETILE 9000mgL new prep1.DATA 140.000 135.000 E LI T E i d O T A T E C A 130.000 125.000 120.000 115.000 110.000 105.000 100.000 95.000 90.000 85.000 80.000 75.000 70.000 65.000 60.000 55.000 50.000 45.000 40.000 35.000 30.000 25.000 20.000 15.000 10.000 5.000 0 -5.000 RT [min] 0 0,5 1 1,5 2 Fig. 1 : 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 10 10,5 11 11,5 2 12 Test Solution R.T. 4.9 ETHYL ACETATE 28 Ur Cert Acet ETILE 450mgL new prep1.DATA E LI T E ot at e c A RT [min] 2,2 2,4 2,6 2,8 Fig. 2 : 7 3 3,2 3,4 3,6 3,8 4 4,2 4,4 4,6 4,8 5 5,2 5,4 5,6 5,8 6 Calibration Standard R.T. 4.9 ETHYL ACETATE 6,2 6,4 6,6 6,8 7 7,2 450 mg/l 7,4 7,6 7,8 8 ETHYL ACETATE IN URINE (Reference Chromatograms) 10.000 9.800 µV 9.600 9.400 9.200 9.000 8.800 8.600 8.400 8.200 8.000 7.800 7.600 7.400 7.200 7.000 6.800 6.600 6.400 6.200 6.000 5.800 5.600 5.400 5.200 5.000 4.800 4.600 4.400 4.200 4.000 3.800 3.600 3.400 3.200 3.000 2.800 2.600 2.400 2.200 2.000 1.800 1.600 1.400 1.200 1.000 800 600 400 200 0 -200 2 27 Ur Cert Acet ETILE 225mgL new prep1.DATA E LI T E ot at e c A RT [min] 2,2 2,4 2,6 Fig. 3 : 2,8 3 3,2 3,4 3,6 3,8 4 4,2 4,4 4,6 4,8 5 5,2 5,4 5,6 Urine Sample R.T. 4.9 ETHYL ACETATE 8 5,8 6 6,2 6,4 6,6 225 mg/l 6,8 7 7,2 7,4 7,6 7,8 8
© Copyright 2026 Paperzz