9400 Via Circonvallazione, 10 13018 Valduggia (VC), Italy Tel: +39 0163 47891 Fax: +39 0163 47895 www.vironline.com DZR Brass Metering Station valvoindustria ing.Rizzio s.p.a. Description DZR brass metering station Threaded M/F ISO7/1 Rp (F side threaded ISO 228/1 on DN15 and DN20) Olive and nut kit for European copper tubing (EN1057, F side only) on request: ● DN15, kit for 15mm pipe ● DN20, kit for 22mm pipe Design according BS7350 Tolerance on nominal Kvs ±3% (test according BS7350) Gost compliant PN25 (Max 25bar up to 80°C, max 20bar at 100°C) Working conditions: ● Water: -10°C to +130°C below 0°C only for water with added antifreezing fluids over 100°C only for water with additives avoiding boiling Part List N. 1 2 3 4 Part Material Norm 4 Body Venturi insert Test point Tie DZR Brass DZR Brass DZR Brass Polyprop. (blue / red) EN12164 CW602N EN12165 CW602N EN12164 CW602N - 3 2 1 Dimensions DN G1 015ULF ½" 015LF ½" ½" 015 ¾" 020 1" 025 1¼" 032 1½" 040 2" 050 H L BF BM I (mm) (mm) (mm) (mm) (mm) 57,2 57,2 57,2 60,0 63,5 69,0 72,0 78,0 60,02 60,02 60,02 62,03 67,6 72,4 72,4 82,0 17,5 17,5 17,5 19,0 22,5 24,8 24,8 29,2 15,2 15,2 15,2 16,5 19,1 21,4 21,4 25,7 22 22 22 22 22 22 22 22 Weight (g) Flow (l/s) 2192 2172 2132 2543 353 463 531 755 0,017-0,045 0,031-0,074 0,062-0,1484 0,138-0,3254 0,258-0,6034 0,540-1,2504 0,810-1,8804 1,520-3,5104 H G 1 ISO7/1 Rp (F side threaded ISO 228/1 on DN15 and DN20) 2 For olive and nut version length 70,7mm, weight +31g 3 For olive and nut version length 73,7mm, weight +37g 4 Suggested flow range applicability (BS7350). BF BM L If used with measuring manometers different from those proposed by VIR please verify that sensibility of the measuring device is compatible with indicated minimum flow (see flow measurement paragraph) I 090610 Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice. 090610 Flow Measurement 100,00 DN15ULF, Kvs venturi 0,55 DN15LF, Kvs venturi 1,15 Kvs venturi 2,80 DN15, Kvs venturi 5,33 DN20, Kvs venturi 9,72 DN25, Kvs venturi 20,25 DN32, Kvs venturi 30,23 DN40, Kvs venturi 55,07 DN50, ∆p TP [kPa] 10,00 1,00 0,10 0,001 0,010 0,100 1,000 Portata [l/s] Formula linking flow Q (in l/s) and ∆p measured at test points (in kPa). Minimum flow that can be measured for each diameter may be calculated by using in the formula minimum ∆p that can be measured by used manometer. Valves are anyway designed for best performances when used on range previously suggested and as indicated by BS7350. 10,000 100,000 ∆pTP High pressure test point Low pressure test point Q= K vsventuri ⋅ ∆p TP 36 Q (flow) Headloss calculation DN 015ULF 015LF 015 020 025 032 040 050 Kv (m3/h) Formula linking flow Q (in l/s) and theoretical valve headloss ∆p (in kPa). 0,61 1,23 3,63 7,56 13,61 30,78 48,10 85,51 Q (flow) ∆p (headloss) 36 ⋅ Q ∆p = KV 2 Installation To obtain the best performances valve must be installed on a pipe with its same nominal size preceded and followed by straight pipe lengths as per figure indications. Min 5xDN (10xDN if installed on pump outlet) Min 2xDN Via Circonvallazione, 10 13018 Valduggia (VC), Italy Tel: +39 0163 47891 Fax: +39 0163 47895 www.vironline.com Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
© Copyright 2026 Paperzz