Look at molecules with a new twist of light CHIRALIR-2X TM VCD Spectrometer Characterization Experts: Chirality & Biologics Vibrational Circular Dichroism Chiral IR -2X VCD Spectrometer V I B R AT I O N A L C I R C U L A R D I C H R O I S M ( V C D ) W A S F I R S T M E A S U R E D I N 1 9 7 3 Unique Advantages of the CHIRALIR-2X™ VCD Spectrometer TM In 1997, BioTools commercialized the technology extends the functionality of electronic Circular by introducing the ChiralIR™. We are proud to Dichroism (CD) into the infrared spectral region be the first company to present a stand-alone where vibrational tranisitions in molecules are dedicated VCD spectrometer and its powerful observed. applications in the fields of chemistry and VCD combines the structural specificity of biology. Dual Source increases signal-to-noise ratio (S/N) of approximately 3.6 times over any single-source system FT-IR spectroscopy with the stereo-sensitivity of 30-48 hour hold detector time circular dichroism. This gives access to multiple, VCD is defined as the difference in the Exclusive stage for elimination of cell artifacts with SyncRoCell™ well-defined bands that provide molecular absorbance (A) of left minus right circularly quantitative information. Measurements can be polarized infrared radiation, A=AL-AR. VCD done in solids and solutions. Simultaneous collection of IR & VCD spectra (AC & DC) Complete spectral range of -1 measurement 4000-850 cm (no change of filters required) ONE MEASUREMENT GIVES TWO SPECTRA: FT-IR AND VCD A X 105 10 h Sample spectrum in full range (1S,2S)-( )-Pseudoephedrine VCD 5 0 -5 A = AL - AR Absorbance 1.0 H IR H3C H3C N H 0.5 H OH 0.0 1500 1400 1300 1200 1100 Wavenumber (cm -1) • Upgrade availability to patented DualPEM™ technology which allows artifact-free measurement of solids E N A N T I O M E R I C PA I R S O F C H I R A L M O L E C U L E S 15 AX 105 10 • Factory aligned baseline resulting in immediate and routine operation • Digital signal processing — no lock-in or electronic filter needed (1R, 2R)-(+)-Pseudoephedrine • Permanently aligned - Lifetime warranty on scan mechanism 5 • Training and support by the experts with unprecedented knowledge in design and applications of VCD 0 • Micro measurements with new VCDμSamplIR™ -5 -10 -15 1000 • ChiralIR-2X™ comes with standard IR cells (optional BioCell™ and TempCon available) • ChiralIR-2X™ is also available in the Near-IR region. (1S,2 S)-( )-Pseudoephedrine 1500 14001 -1 -1 The instrument can also be configured for coverage from 2000 to 4000 cm or from 4000 to 10000 cm 300 1200 Wavenumber (cm-1) -2- 1100 1000 Standard IR Cell -3- DualPEM Accessory (internal) MANTIS DualPEM Accessory (external) TM TM DualPEM™ provides significant improvement in baseline position and stability over single PEM systems. TM MANTISTM — External DualPEM™ Option The second PEM subtracts birefringence from optics in real-time thus providing a significant reduction in artifacts, improved stability and is a requirement for measuring VCD of solid samples. • Now available as an internal or external accessory 2 • DualPEM™ is a patented technology of BioTools 1 DualPEM™inside the CHIRALIR-2X™ VCD Spectrometer (R- S)/2 0 -2 Δ A x10 4 -1 Dual Modulation -3 Single Modulation -4 ChiralIR-2X ™ Instrument -5 -6 1650 1550 1450 1350 1250 1150 -1 W avenumber (cm ) 1050 950 MANTISTM DualPEM™ Accessory (connects seamlessly to side of ChiralIR-2X ™ ) External DualPEM™ Applications • Reaction Monitoring • Micro Measurements – VCDμSamplIR™ Sampling of solid samples at 1mm2 spatial resolution • Magnetic VCD (MVCD) • Matrix Isolation Look at molecules with a new twist of light • Gas Sampling ...any other accessory that needs more space than a standard sample or compartment MANTISTM DualPEM™ To upgrade your existing FT-IR Spectrometer to VCD capability, please contact us -4- -5- VCD Accessories Award Winning Patented Technology ChiralIR-2X ™ Technology • Thousands of molecules measured using the ChiralIR platform SyncRoCell™ • Hundreds of patents on new compounds Rotating stage for elimination of cell artifacts • Hundreds of customer scientific papers using the ChiralIR series • Used for submissions to regulatory agencies • Articles in U.S. Pharmacopoeia Te m p C o n ™ Award Winning Features & Technology Te m p Con™ temperature controller unit is designed for Peltier based temperature controller use in FT-IR spectrometers with two types of windows: large circular B i o Cell™ windows and rectangular windows. The controller can be controlled either manually or through computer input. The Ramp-Soak Control Interface allows for temperature studies that can be aligned with FT-IR scanning software and can be used in applications such as effect of temperature on protein conformation. BioTools U.S. Patents W E P R O U D LY S E R V E H U N D R E D S O F C O M PA N I E S , U N I V E R S I T I E S A N D G O V E R N M E N T A G E N C I E S AMGEN • Astellas • Astra-Zeneca • GlaxoSmithKline • Bristol-Myers Squibb Eli Lilly • Janssen • Lupin • Merck • Pfizer • Takeda • and others... W H AT O U R C U S T O M E R S A R E S AY I N G BioCell™ The CaF2 cell for IR/UV-CD spectroscopy is created between a perfectly flat, optically clear plate and another plate, the center of which is deepened to form a recessed parallel surface surrounded by a groove. The cells are very easily assembled and disassembled, filled with solution, and washed between measurements. “Over the last several years, the Vibrational Circular Dichroism (VCD) technique has dramatically revitalized the utility and visibility of vibrational spectroscopy within pharmaceutical drug discovery. The ability of VCD to deliver absolute chiral assignments without the need for standards or crystallizations, renders the technology a vital complement to traditional pharmaceutical analytical technologies. “ Dr. Don Pivonka, AstraZeneca “As a long-standing analytical chemist in pharmaceutical research with a focus on vibrational spectroscopy, I recognized the potential impact VCD could have on many aspects of big pharma. With the ChiralIR I have successfully assigned the configurations of more than 600 exploratory drug molecules, providing an international service to research facilities in Europe and the United States.I consider this instrument to be world-class and a bargain for the price given its state-of-the art technology and incredible level of reliability. “ Wide range of available path lengths: ~5-10, ~20, ~40, ~80 and ~120 mm 5 mm thickness x 50 mm diameter standard size. Cells with 4 mm x 40 mm dimensions and other custom sizes are also available Dr. Douglas James Minick, Senior Research Investigator, GlaxoSmithKline -6- -7- Software ComputeVOA™ Software An all inclusive package for calculation of VCD spectra. Combines: structure building, extensive conformational search, easy integration with Gaussian09 and plotting of calculated spectra. CompareVOA™ Software Confidence level algorithm for comparing VCD (and ROA) experimental and theoretical spectra; the output generates two plots: IR and VCD comparisons of measured and calculated spectra, and statistical plot against a database of prior comparisons. Screen Shot Coming ComputeVOA orchestrates a complex molecular dance. Data enters the stream through a molecule builder/ structure importer then moves into a robust molecular mechanics conformational search algorithm. The results then pass through a transparent handshake to Gaussian 09 (Gaussian, Inc. Pittsburgh,PA) where quantum mechanics determines the molecule’s structure and properties. It then returns seamlessly to ComputeVOA for a Boltzmann-averaging of conformers and plotting of the IR and VCD spectra. The final output: The specific stereo isomers’ 3D structure and accompanying InfraRed and Vibrational Circular Dichroism spectra. -8- ChiralIR-2X ™ Software Included with the CHIRALIR-2XTM. Easy to use, no learning curve. -9- Application Examples Chiral Drugs Chiral Drugs Quality Control Since commercial introduction of VCD by BioTools thousands of compounds have been determined using VCD can be used as a chiral measure for characterization of raw materials for process analytical technology (PAT) during development, synthesis, formulation, and final production of drug substances and drug products. VCD also can be used to test the interaction between formulated chiral drug substances and excipients. this technology. It has become the-must-have-tool in the pharmaceutical and other industries. A B S O L U T E C O N F I G U R AT I O N D E T E R M I N AT I O N S Step 1: Choose Configuration e.g. (R) - Mirtazapine Configuration Step 3: measure IR (bottom) and VCD (top) spectra Step 2: Calculate IR (bottom) and VCD of available enantiomer, e.g. (-) -Mirtazapine (top) spectra of (R) - Mirtazapine 1.0 200 A 0.5 100 H3C N H N N “The absolute configuration of chiral compounds is critical in understanding structure-activity relationships, and in developing appropriate chiral separation, resolutions, or synthesis.” “Vibrational Circular Dichroism (VCD) data are now being used to support New Drug Applications and patents.” Comparison of observed VCD spectra (right) with calculated VCD spectra (left) unambiguously determines absolute configuration (-)-(R)-Mirtazapine and conformation in solution as shown above. “The bottom line with VCD or any new analytical method is if the data are convincing to the scientists developing the drug, then that data should be convincing to the scientists here at the FDA.” Stephen P. Miller, Office of New Drug Chemistry,FDA’s Center for Drug Evaluations & Research Chemical & Engineering News - 7/18/05 - 10 - - 11 - VCD Application Examples Proteins - Peptides - Carbohydrates - Nucleic Acids Reaction Monitoring PROTEIN / PEPTIDE STRUCTURAL STUDIES ASYMMETRIC REACTION MONITORING b) Characterization of Fibrils a) Secondary Structure AX 105 VCD SHOWS A HIGH SENSITIVITY TO 24 G 20 F 16 E 12 D 8 C 4 B 0 A -4 STRUCTURE OF FIBRILS H + O O H C CF3COOH OH + CF3COOH O OH HO H O HO O H + H 100 VCD IR 1.2 CCl4 MCH 80 G: Concanavalin A F: -Chymotrypsin Formative Stages of Amyloid Fibrils 60 0.8 D: Lysozyme 40 C: Cytochrome c 0.4 Predicted EE% Absorbance E: Ovalbumin B: BSA 20 A: Myoglobin 0.0 1800 1600 Wavenumber (cm -1) 1400 Proto-Filament/ Filament Proto-Fibril/ Fibril Mature Fibril VCD provides an enhanced sensitivity to secondary structure of proteins and peptides. The changes in VCD spectra are observed in both the Amide I and II regions. The VCD sign of Amide I band changes for proteins with the two most common motifs - α-helical protein myoglobin (lower spectra) and a primarily β-sheet containing proteins concanavalin A and chymotrypsin (upper spectra). F E AT U R E S : 0 02 02 04 04 06 06 Time (hr) During the course of a chemical stereospecific reaction, the combination of IR, for detection of changes in mole fraction composition, and VCD, for combined mole fraction composition and enantiomeric excess (%EE), enables one to follow %EE of each chiral species as a function of time. The figure above shows epimerization versus time of DDM with trifluoroacetic acid in two different solvents. • The largest FT-VCD protein database available • Dedicated software for protein data analysis - 12 - 080 - 13 - Lab Services Customer Support CHIRALIR-2X ™ Installation • Installation and training on measurement and interpretation of VCD spectroscopy of small molecules by experienced scientists CHIRAL MOLECULES • Absolute Configuration • VCD Measurements • Qualification provided (IQ/OQ/PQ) • ab initio calculations (VCD, ECD, ROA) • BioTools’ combined service and application knowledge • VCD Consulting & Training Technical Support and Maintenance BioTools provides users of CHIRALIR-2XTM with complete maintenance and technical support. Each instrument sold comes with a full one year warranty. Additional maintenance contracts can be purchased. • Chiral Methods Development PROTEINS / PEPTIDES • % Enantiomeric Excess • Secondary Structure • Small Scale (~1g) Purifications E-mail based help desk is open 365/24/7 at [email protected] • Formulation of Biologics Consulting • Effect of Environmental Changes - temperature, pH, storage BioTools offers consulting services that bring our expertise on spectroscopy of chiral molecules to bear on your applications and needs. Costs depend on the extent of the study and degree of urgency. • Structural comparison of production lots • Comparability Vibrational Optical Activity: Principles and Applications by Laurence A. Nafie This unique book stands as the only comprehensive introduction to vibrational optical activity (VOA) and is the first single book that serves as a complete reference for this relatively new, but increasingly important area of molecular spectroscopy. “Vibrational Optical Activity: Principles and Applications” will take the reader from the basic theory through the practical and instrumental approaches, providing a unified, comprehensive description to the field of VOA that gives both introductory and in-depth coverage to VCD and ROA. Applications include the analysis of all classes of chiral molecules, including organic and inorganic molecules, metal complexes, pharmaceutical and natural product molecules, and the full range of biological molecules such as amino acids, peptides, sugars, proteins, protein fibrils, carbohydrates, nucleic acids, viruses and bacteria. Written in a thorough and progressive style, it will appeal to advanced undergraduates, graduates and research groups in academia as well as researchers and technicians in the pharmaceutical and biotechnology industries. Signed Copies Available ChiralIR-2X ™ - 14 - - 15 - Characterization Experts: Chirality & Biologics Prota-3STM FT-IR ChiralRAMAN-2XTM (ROA, Now with AFM / TERS) µBioRAMANTM MantisTM (DualPEM VCD accessory) ComputeVOATM CompareVOATM BioTools Worldwide Corporate Headquarters North America 17546 Bee Line Highway Jupiter, Florida 33458 USA Phone: 561.625.0133 Fax: 561.625.0717 [email protected] • www.btools.com Europe • Asia • Middle East • South America IF-720-MCI-0001 • REV. 2.0 • 092014
© Copyright 2026 Paperzz