05029 TENDER PACKAGES POST TENDER ADDENDUM NO. 1 10 MARCH 2008 NORTH TORONTO COLLEGIATE INSTITUTE 17 BROADWAY AVENUE TORONTO, ONTARIO C. S. & P. Architects Inc. 2345 Yonge Street, Suite 200 Toronto, Ontario M4P 2E5 This Addendum forms part of the Bid Documents and is to be read, interpreted and coordinated with all other parts. The cost of all work contained herein is to be included in the bid sum. The Specifications and Drawings are complementary. Items listed under the Specifications in this Addendum and having influence on the Drawings are so deemed to alter the Drawings. Items listed under the Drawings in the Addendum and having influence on the Specifications are so deemed to alter the Specifications. This Addendum contains the following: 4 typewritten pages Structural Addendum S-04, dated March 10, 2008 (11 pages) Mechanical and Electrical Addendum P.T.A. #1, dated March 10, 2008 (15 pages) Architectural Detail Drawings: AD-50, AD-51, 3057, 3058 TENDER PACKAGES ADDENDUM NO. 1: Architectural Drawings: Revise sheet title reference from Drawing A7.9 to A7.4 TENDER PACKAGES ADDENDUM NO. 2: Architectural Detail Drawings: Item 9: Revise Detail reference from 4021 to 4020. SPECIFICATIONS: SECTION 05500 – MISCELLANEOUS METAL 3.2 SCHEDULE OF COMPONENTS Delete paragraph: .2.13 Elevator hoist beams SECTION 06410 – CABINETWORK 1.2 RELATED WORK Revise paragraph: .6 Display Case Light Lens Section 10950 Add paragraph: .10 Aluminum Grilles Section 10950 1 05029 TENDER PACKAGES POST TENDER ADDENDUM NO. 1 10 MARCH 2008 SECTION 09250 – GYPSUM BOARD 2.2 GYPSUM BOARD Revise paragraph: .6 Exterior Sheathing: Dens Glass Gold by Georgia Pacific, Aqua Tough by CGC, or Glasroc by CertainTeed. SECTION 09310 – CERAMIC TILE 2.1 MATERIALS .15 TILE Revise paragraph: .1 3.4 CT.1: 300 x 600 mm porcelain floor tile; include in Contract an allowance of $40.00/m² for supply only of CT.1 tile. GROUTING Revise paragraph: .5 Provide latex grout at all locations. SECTION 09690 – CARPET TILE 2.1 MATERIALS Revise paragraph: .1 Carpet tile: 610 x 610 mm, ¼ Turn, “Level Two” Series by Interface Floor, colours selected by Consultant. Provide ALTERNATIVE PRICE for “repartee” (style number 59387) by Shaw Contract Group, colours selected by Consultant. SECTION 10500 – METAL LOCKERS 1.3 DESCRIPTION .1 Type 1 lockers: Revise width from 305 mm wide to 254 mm wide. SECTION 10950 - MISCELLANEOUS SPECIALTIES Add sections: 2.3 DISPLAY CASE LIGHT LENS 1. Display Case Light lens: prismatic clear acrylic sheet, pattern selected by Consultant, cut to size required, by A.L.P. Lighting Components Inc, or other manufacturer approved by Consultant. Locations: Display Case millwork, under lights. 2 05029 2.4 TENDER PACKAGES POST TENDER ADDENDUM NO. 1 10 MARCH 2008 ALUMINUM GRILLES 1. Aluminum Grilles: Product LBP Series Linear Bar Grille by E.H. Price; Core 25C (pencil proof); Border 750; Fastening Type A countersunk screws; Finish: clear anodized. Locations: top of millwork in front of heating units, as shown on Drawings. SECTION 11600 - LABORATORY EQUIPMENT 2.2 FUME HOODS Revise paragraph: .2.5 Motor start switch with pilot light, prep room side. ARCHITECTURAL DRAWINGS A2.12 1. A2.18 1. A2.20 GROUND FLOOR PLAN NORTH Student Commons 1007: Delete reference to Detail 5055 south of Grid S8. FOURTH FLOOR PLAN NORTH Electrical Room 4009: add note to east block wall: ‘1100 mm high partial concrete wall over block- refer to Structural’. Add the same note at block wall along Grid S13, between SY and Swx. ROOF PLAN NORTH 1. Indicate all mechanical devices (fans, cooling units etc) on roof as shown on Mechanical Drawing M-53. A2.21 ROOF PLAN SOUTH 1. Indicate all mechanical devices (fans, cooling units etc) on low roof and upper roof as shown on Mechanical Drawings M-40 and M-54. A3.1 WEST AND NORTH BUILDING ELEVATIONS 1. Drawing 1/A3.1: At Grid S11, at Datestone: revise reference from Detail 3003 to Detail AD-51. A5.10 1. A5.13 1. INTERIOR ELEVATIONS Drawing 4/A5.10: Elevation C: Add upper cupboards over desk, Detail 5022. INTERIOR ELEVATIONS Drawing 8/A5.13: Add note: ‘1 Nitric Acid Isolator Compartment located inside Acid Storage Cabinet’. ARCHITECTURAL DETAILS 1. 2. 3. 4. 5. Detail 2112: Revise note ‘solid wood sill’ to ‘plam sill’ Details 2040, 2098, 4095, 4117, 4118, 4119, 4120, 4121, 4122, 4123: Not used Detail 3010: Add clarification note to drawing: ‘51 x 51 x 6 steel angle is miscellaneous metal’. Detail 3065: Revise ‘PLAM sill’ to ‘solid hardwood sill.’ Detail 4043: Revise door frame to indicate wood instead of HM. 3 05029 TENDER PACKAGES POST TENDER ADDENDUM NO. 1 10 MARCH 2008 ROOM FINISH SCHEDULE 1. 2. 3. West Corridor 2064: Revise finishes as follows: Wall finish CB/CS, Floor finish VCT, ceiling GB/P 2700. Staff Lounge 2069: Revise floor finish from VCT to CPT. Corridor 3024, 4016: Revise floor finish from CT.1 to VCT DOOR SCHEDULE 1. Door XB033: Revise door height from 2250 mm to 2350 mm END 4 Post-Tender Addendum Date: March 10, 2008 Project Name: North Toronto Collegiate Institute Client: CS&P Architects 156 Front Street West, Suite 600 Toronto, Ontario M5J 2L6 Phone (416) 598-2920 Fax (416) 598-5394 www.mcw.com To: CS&P Architects Attention: Susan Lewin Fax number: 416-482-5040 Distribution: [email protected] Project No.: 6830 ADD No.: P.T.A.# 1-for Package 1 & 2 Page No.: 1 of 6 + 9 attached Office: Toronto From: Stephen Lau Karin Schembri In accordance with the drawings and specifications, provide in the tender all costs required to complete the work including items as listed below : MECHANCIAL Specification 1.1 Section 15050 Mechanical Basic Materials And Methods .1 1.2 Article 3.28 Detail Drawing .1 Delete Detail Drawing V-31Lab. Desk Exhaust Opening. Section 15100 Vibration Isolation .1 Article 1.02 Work Preformed By This Section .1 Add the following sentence .2 to article 1.02: “.2 Provide acoustical panels for the construction of the Outside Air Intake Plenum and the Exhaust Air Discharge Plenum for the 3rd Floor Mechanical Room.” .2 Delete article 2.04 Floating Floor and article 3.03 Floating Floor from Section 15100. .3 Add the following new article 2.07 Acoustical Panels: “2.07 Acoustical Panels: Project Name: To: 1.3 North Toronto Collegiate Institute CS&P Architects Project No.: PTA No.: Page No.: 6830 001 2 of 6 .1 Provide acoustical panels for the construction of the Outside Air Intake Plenum and the Exhaust Air Discharge Plenum for the 3rd Floor Mechanical Room or any other areas as shown on the drawings. .2 Construction: .1 RECTANGULAR: 18 ga. galvanized steel outer shell with lock formed mastic filled seams pre-fabricated, with 40 kg/m3 (2 1/2 lb/ft3) density acoustic media packed under 10% compression and protection from air erosion by 20 ga. interior galvanized steel liner. .2 Joints between panels to be sealed with approved type water proofing materials.” Section 15400 Plumbing .1 Article 2.01 Plumbing Fixtures and Brass. .1 Add the following new paragraphs to article 2.01: “.35 Mixing Valve (MV-3): Provide tempered water mixing valve –Symmons Model 5-110 PRV, capacity 2 gpm (7.5 LPM) at 10 psi pressure drop, suitable for 29 C to 71 C water temperature, thermostatic temperature control valve with liquid filled motor, check stops, safety shut-off, volume control valve, rough bronze, ball valves, dial thermometer, in a stainless steel cabinet, top supplies, top outlet. .36 Mixing Valve (MV-3A): Provide tempered water mixing valve –Symmons Model 5-140 PRV, capacity 12 gpm (45 LPM) at 10 psi pressure drop, suitable for 29 C to 71 C water temperature, thermostatic temperature control valve with liquid filled motor, check stops, safety shut-off, volume control valve, rough bronze, ball valves, dial thermometer, in a stainless steel cabinet, top supplies, top outlet.” 1.4 Section 15725 Variable Frequency Drives .1 Article 2.01.17 Variable Frequency Capacity Chart: .1 Motor horse powers indicated in the capacity chart for Pumps P-6 & P-7, P-10 & P-11 and P-15 & P-16 are for each pump. Add the word “each” to 2 Project Name: To: North Toronto Collegiate Institute CS&P Architects Project No.: PTA No.: Page No.: 6830 001 3 of 6 the HP column. Drawings 2.1 Drawing M-4, Parking Level P-3 South– Plumbing .1 2.2 Drawing M-8, Basement Plan P-1 South– Plumbing .1 .2 2.3 .2 .2 In Corridor ‘1052’ & Ceiling of Gymnasium. Reroute 100ø Sanitary going north and delete 75ø Sanitary line from funnel floor drain and provide new 100ø Sanitary and 50ø Condensate Drain from above and drop down in mechanical Shaft as shown on Sketch RM-M10-1. In Mechanical Rooms ‘1037’ & ‘1062’, provide new Mixing Valve c/w Hot & Cold water connections to Emergency Equipment ‘EW-3’. Drawing M-11, Second Floor Plan North – Plumbing .1 .2 2.6 In Music Storage Room ‘1042’ & Drama Room ‘1030’. Reroute Condensate Drain from Fan Coils Units and relocate 20ø cold water line to exterior Hose Bibb as shown on Sketch RM-M9-1. IN Washroom ‘1019’, provide new Mixing Valve ‘MV-3’ located in ceiling space and connect to Hot & Cold water lines servicing lavatory. Drawing M-10, Ground Floor Plan South – Plumbing .1 2.5 Provide structural box out in 1200mm beam and bring new 50ø Condensate Drain from above at grid lines ‘S21’ & ‘SZ’. Provide new 100ø Sanitary Drain from above at grid lines ‘S29’ & ‘SX’ and run along beam new 100ø Sanitary line and connect to new 100ø Sanitary line (previously sized 50ø) as shown on Sketch RM-M8-1. Drawing M-9, Ground Floor Plan North – Plumbing .1 2.4 In Mechanical Room, provide new Mixing Valve c/w Hot & Cold water connections to Emergency Equipment ‘EW-3’. In Data Room ‘2022’, Archive Room ‘2023’ , Seminar Room 3 Heritage ‘2024’ and Storage Room ‘2026’’, reroute Condensate Drains from Fan Coils Units and drop down in plumbing wall as shown on Sketch RM-M11-1. In Washroom ‘2017’, provide new Mixing Valve ‘MV-3’ located in ceiling space and connect to Hot & Cold water lines servicing lavatory. Drawing M-12, Second Floor Plan South – Plumbing .1 In Seminar Room 2 – Media – ‘2041’. Reroute Condensate Drains from Fan Coils Units and drop down inside plumbing shaft as shown on Sketch RM-M12-1. 3 Project Name: To: .2 2.7 .2 In Washroom ‘3014’, provide new Mixing Valve ‘MV-3’ located in ceiling space and connect to Hot & Cold water lines servicing lavatory. In Washroom ‘3014’, provide new Mixing Valve ‘MV-3’ located in ceiling space and connect to Hot & Cold water lines servicing lavatory. In Washroom ‘4003A’, provide new Mixing Valve ‘MV-3’ located in ceiling space and connect to Hot & Cold water lines servicing lavatory. Provide new Mixing Valve c/w Hot & Cold water connections to Emergency Equipment ‘EW-1’ & ‘EW-2’ in the following Rooms: Physics Preparation ‘4013’ General Science ‘4044’ General Preparation ‘4045’ Drawing M-16, Fourth Floor Plan South – Plumbing .1 2.11 In Storage Room ‘2044’, provide new Mixing Valve c/w Hot & Cold water connections to Emergency Equipment ‘EW-2’. Drawing M-15, Fourth Floor Plan North – Plumbing .1 2.10 6830 001 4 of 6 Drawing M-13, Third Floor Plan North – Plumbing .1 2.9 Project No.: PTA No.: Page No.: Drawing M-13, Third Floor Plan North – Plumbing .1 2.8 North Toronto Collegiate Institute CS&P Architects Provide new Mixing Valve c/w Hot & Cold water connections to Emergency Equipment ‘EW-1’ & ‘EW-2’ in the following Rooms: Physics 9 - ‘4014’ Physics 15 - ‘4015’ General 7 – ‘4029’, General 6 - ‘4030’ Biology 5 – ‘4036’ Biology 4 – ‘4037’ Science Preparation ‘4038’ Chemistry 1 – ‘4043’ Chemistry 2 – ‘4044’ Drawing M-62, Domestic Water Schematics .1 Provide new Mixing Valve ‘MV-3A’ located in ceiling space and connect to Hot & Cold water lines servicing lavatories as shown on schematic Water riser ‘WR # 2’ servicing Female and Male Public Washrooms on four (4) typical stacked floors and also provide Mixing Valve ‘MV-3’ in the following Washrooms: ‘1019’ ‘2017’ 4 Project Name: To: North Toronto Collegiate Institute CS&P Architects Project No.: PTA No.: Page No.: 6830 001 5 of 6 ‘3014’ ‘4003A’ As shown on sketch RM-M62-1. 2.12 Drawing ME-2, Mechanical Equipment Schedule 2 .1 Revise the following equipment schedules: - Heat Recovery Unit Schedule - AHU and HRU Fan Schedule - Enthalpy Wheel Schedule Refer to attached sketches: RM-ME2-1, RM-ME2-2 and RM-ME2-3. ELECTRICAL 1.0 Specification 1.1 Section 16778 – Local Sound System .1 Paragraph 2.02 Suppliers and Systems .1 Add Baldwin Sound Systems Ltd. as acceptable manufacturer. 2.0 Drawings 2.1 Drawing E-6, Ground Floor Plan North - Lighting .1 2.2 Provide 3 type ‘F9’ surface mounted fixtures with 120V ballast. Connect 2 fixtures to circuit TH-8 and one fixture in centre to circuit 2EG-10. .3 Provide two 3-way switches at south door and connect to light fixtures. Mechanical Rooms, Garbage Room and Sprinkler Room .1 Provide one type 5 PA speaker in each room (total of 5) and locate adjacent to entry door of each room. Drawing E-15, Basement Plan P1 Level South – Power and Systems .1 2.4 .2 Drawing E-13, Parking Levels P2 and P3 Part Plans – Power and Systems .1 2.3 Control Room M2002 .1 Delete 5 type ‘C7’ light fixtures Gymnasium B035 and B036 .1 Provide a total of three 15” clocks c/w wire guard. Mount one over each of three double doors exiting into Corridor B031. Drawing E-17, Ground Floor Plan South – Power and Systems 5 Project Name: To: 2.5 .2 Keyboard Seminar 1050 .1 Provide 12” clock and type 3 PA speaker, mount on south wall. Drawing E-19, Second Floor Plan South – Power and Systems 2.9 Electrical Room 2020 .1 Delete lighting distribution panel ‘2DPL’. .2 Revise designation for distribution panel ‘2DP2’ to read ‘DP2B’. .3 Revise designation for lighting panel LP-‘2L2’ to read LP-‘6L2’ .4 Locate emergency lighting panel LP-‘6E2’ in this room. Drawing E-21, Third Floor Plan South – Power and Systems Revise designation for distribution panel DP-‘2DP3’ to read ‘DP2C’. Drawing E-22, Fourth Floor Plan – Power and Systems .1 2.8 6830 001 6 of 6 Administration 1069 .1 Provide 12” clock on east wall north of grid line S22. .1 2.7 Project No.: PTA No.: Page No.: .1 .1 2.6 North Toronto Collegiate Institute CS&P Architects Revise designation for distribution panel ‘2DP’ to read ‘DP2D’. Drawing E-24, Single Line Diagram – Electrical .1 Transformer ‘TXE’ .1 Run 4-F12 feeder to distribution panel ‘DP2E’ .2 Automatic Transfer Switch ATS-1 .1 Run 4-F-16 feeder from ATS-1 to distribution panel ‘DP6E’ and connect. Drawing E-25, Schedules – Electrical .1 Occupancy Sensor Schedule .1 Revise type 1 occupancy sensor to model number PW-100-24, low voltage. End of addendum ADD PT-001 6
© Copyright 2026 Paperzz