DS-W-PRP-00-00-0612-03-A Mainline Propeller Meters Models 111/112 — Plain End Tube Type Description 150 psi (10 bar) Working Pressure, 300 psi (20 bar) Working Pressure, Magnetic Drive Sealed Gear Housing, Sizes 4” through 36” (DN 100mm—DN 900mm) Sensus Propeller Meters are intended for accountability measurement of potable or non-potable cold (to 100°F/38°C) water where flow is in only one direction. The meters can be installed at any convenient angle from horizontal to vertical; in discharge, suction or pressurized lines; within stated pressure ratings. For accurate measurement, a full flow of water through the meter and stated minimum flow rates are required. Because all appropriate parts are sealed for protection, the meters can be used with water containing particulate solids (as sand), without causing undue wear. Model 111 Standard Sealed Register E-ROFI Register Features CONSTRUCTION REGISTERS The meters are produced of fabricated steel and protected internally by an epoxy paint. Sensus Propeller Meters are available with a standard sealed mechanical register (Model 111) or a sealed Electronic Rate of Flow Instrument and Transmitter—EROFI (Model 112). MAGNETIC DRIVE Eliminates mechanical packings and stuffing boxes. A sleeve-type ceramic magnet in the propeller assembly drives a follower magnet located within the sealed gear box. RIGHT ANGLE GEARING The brass bevel gears, which drive the register shaft, operate within a factorysealed, oil-filled, one-piece cast bronze gear box, providing lubrication for the life of the meter. CERAMIC BEARING AND SHAFT The double land ceramic bearing retained in the propeller assembly rotates on a ceramic sleeved shaft. The high purity ceramic provides exceptionally good wear characteristics, even in water containing entrained solids. INSTRUMENTATION CAPABILITIES The E-ROFI or High-Speed Pickup Registers are available for interfacing with Sensus Act-Pak Instruments. Refer to Bulletin E-1116 for HSPU and Bulletin E-1110 for E-ROFI Register. INSTALLATION The meter is installed in the pipeline similar to placing a short length of plain end pipe in the line either by welding, brazing or using pipe couplings, such as Smith-Blair #411 flexible couplings. The meter must have a full flow of liquid to assure proper registration. Valves, fittings and other equipment which may create a flow disturbance, should be positioned at least five pipe diameters upstream, and three to five diameters downstream from the meter. GASKETS A flat gasket is used at the connection of the meter head to the body on 4” (DN 100mm) through 8” (DN 200mm). An “O” ring is used on 10” (DN 250mm) and larger sizes. MAINTENANCE Should maintenance or testing be eeded, the meter head can be removed without disturbing the tube body in the pipeline. Cover plates are available for maintaining service or flushing of lines when the meter head is removed. DS-W-PRP-00-00-0612-03-A Page 2 of 2 A K D Model 112 Model 111 3.50" 4.25" H B Meter Size 4” DN 100mm 6” DN 150mm 8” DN 200mm 1 Low Flow GPM m3/h Normal Range GPM m3/h 1 2 82 125-500 18.2 28-114 160 220-1200 36.3 50-273 190 250-1650 43.2 57-375 10” DN 250mm 260 330-2500 59.0 75-568 12” DN 300mm 257 350-3500 62.4 80-795 14” DN 350mm 350 450-4500 79.5 102-1022 16” DN 400mm 450 550-5500 102.2 125-1249 18” DN 450mm 550 725-7250 124.9 165-1647 20” DN 500mm 700 850-9000 159.0 193-2044 24” DN 600mm 1000 1300-1300 227.1 295-2952 30” DN 750mm 1600 2100-18600 363.4 477-4224 36” DN 900mm 2400 3000-2400 545.0 681-5450 A in mm B in mm D in mm H in mm K in mm Shipping Weight Pounds kg 17” 432mm 4-1/2” 114mm 6-1/2” 165mm 3-7/8” 99mm 7-1/2” 190mm 45 lbs. 20 kg 21” 533mm 6-1/2” 168mm 8” 203mm 5” 127mm 9” 229mm 75 lbs. 34 kg 23” 584mm 8-5/8” 219mm 8” 203mm 6” 152mm 9” 229mm 100 lbs. 45 kg 25” 635mm 10-3/4” 273mm 9-1/2” 241mm 7-3/8” 187mm 11” 279mm 120 lbs. 54 kg 27” 686mm 12-3/4” 324mm 9-1/2” 241mm 8-3/8” 213mm 11” 279mm 160 lbs. 73 kg 41” 1041mm 14” 356mm 11-1/2” 292mm 9-1/4” 235mm 13-1/2” 343mm 275 lbs. 125 kg 47” 1194mm 16” 406mm 11-1/2” 292mm 10-1/4” 260mm 13-1/2” 343mm 340 lbs. 154 kg 53” 1346mm 18” 457mm 14-1/2” 368mm 11-5/8” 295mm 13-1/2” 343mm 400 lbs. 181 kg 59” 1499mm 20” 508mm 14-1/2” 368mm 12-5/8” 321mm 13-1/2” 343mm 500 lbs. 227 kg 71” 1803mm 24” 610mm 17-1/2” 445mm 12-5/8” 321mm 13-1/2” 343mm 675 lbs. 306 kg 83” 2108mm 30” 762mm 17-1/2” 445mm 12-5/8” 321mm 13-1/2” 343mm 950 lbs. 431 kg 95” 2413mm 36” 914mm 19-1/2” 495mm 12-5/8” 321mm 13-1/2” 343mm 1250 lbs. 567 kg SPECIFICATIONS SERVICE Where fluid flow is in one direction only. ACCURACY 100 ± 2% of actual flow within specified normal and intermittent flow ranges. 95% minimum at low flow rate. PRESSURE RATING 9150 psi (10 bar) maximum working pressure; 300 psi (20 bar) maximum working pressure. TEMPERATURE 100°F (38°C) maximum. MAXIMUM FLOW Maximum normal flow rates listed are for continuous service. See bulletin PM-725 for details. INTERMITTENT FLOW 25% overrated capacity for 10% to 15% of the total operating time of the meter. STANDARD REGISTER Six-digit straight reading type with full 3” (75mm) diameter, 100-division dial and center sweep test hand. Registration available in gallons, cubic feet, acre feet, litres, cubic meters, miners inch hours, barrels and other standard units. ELECTRONIC RATE OF FLOW INSTRUMENT/ TRANSMITTER The electronic rate of flow instrument (E-ROFI) registers are used to display and transmit volume and flow rate data from a Sensus Propeller Meter to various Sensus Act-Pak Electronic Instruments which are used to monitor, control, record volume, and rate of flow. ActPaks are normally located apart from the meter. The instrument is mounted on Sensus Propeller Meter Head Assemblies using the sealed register type adapter plate assemblies. MATERIALS Tube Bodies: 4” (DN 100mm) through 36” (DN 900mm) Sizes: Fabricated steel body and straightening vanes coated internally and externally with epoxy paint. Meter Head: Ductile Iron Propeller and Nut: Polypropylene Propeller Spindle: Ceramic-Coated Stainless Steel Rotor Bearings: Ceramic Magnets: Permanent, Ceramic Sleeve Type Gear Housing: One-Piece Cast Bronze Shafts and Bolts: Stainless Steel OPTIONAL EQUIPMENT Blank covers, E-ROFI Registers and HSPU for use with Sensus Act-Pak Instruments. Low Flow — 95% minimum accuracy 2 Intermittent Flow — 25% over maximum rated capacity © All products purchased and services performed are subject to Sensus’ terms of sale, available at either; http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Road, Suite 700 Raleigh, NC 27615 1-800-638-3748 www.sensus.com/water
© Copyright 2026 Paperzz