NATIONAL STANDARDS WEIGHTS 6, MEASURES (PATTERNS COMMISSION DF INSTRUMENTS) REGULATIONS REGULATION9 CERTIFICATEOF APPROVAL No 6/14B/12 This is to certify pattern and,variant Mercury that an of the Model HSD Automatic approval Hopper has been Weighing granted for use South are suitable for The approval is subject Comnission that the Pty Ltd SO31 trade. to Instruments purporting 6/l 48/l Australia, the Instrument submitted by Mercury Weighing And Control Systems 32 Dew Street Thebarton, by review an or after l/9/88. to camply with this approval shall be marked RSC No 2. Relevant drawings specificationsare lodged with and the CUIWSS~O~. Condition of Approval (Variant1) Only one method of mass indication (either the primary digital indicator or the the other indicator shall be dial indicator) may be in use at any one time; rendered inoperative. Signed v DescriptiveAdvice Pattern: approved l/8/83 model HSD automatic hopper capacity and with up to 1SOO scale Mercury . Variant: approved weighing instrument 15 DOD kg maximum l/8/83 With a dial indicatoradded and displaying750 scale intervals. 1. TechnicalSchedule No 61148112 &ted 23/8/83 describes the Filing Advice The of intervals. docunentatianfar this approval comprises: Certificateof Approval No 61148112 dated 23/8/83 TechnicalSchedule No 6/148/12,dated2318183 Test Procedure Figures 1 and P/8/83 No 6/148/12 dated 2 dated P/8/83. 2318183 pattern and variant. NATIONAL - STANDARDS COMMISSION TECHNICALSCHEDULE No 6/148/l Model HSD Automatic Hopper Pattern: Mercury Submittor: Mercury Weighing And Control Systems 32 Dew Street Thebarton, South Australia, 5031. 2 Weighing Instrument Pty Ltd Descriptionof Pattern 1. A self-indicatingautomatic hopper weighing system of 15 000 kg maximum capacity and up to 1500 verificationscale intervals,using an HBM model Z3H3 500 kg lead cell (NSC approval No Sl53) and a Mercury model 900 digital indicator (NSC approval No S132). Figure 1 is a schematic diagram of mechanism approved in Variant 1. A low pressure cut-out the air-supply pressure the system, including the dial indicating switch causes the computer to revert to manual operation if drops below 375 kPa. Markings 1.1 Instrumentsare marked Manufacturerls with following data: the name or mark Model number Serial number NSC approval numbers NSC No 6/148/l 2 IndicatorNSC No L d Cell NSC No class capacity Minimum capacity Verificationscale interval S132 Sl53 I 0 ox 15 000 kg* Accuracy Maximum Min end 500 kg* = 10 kg* VerificationProvision 1.2 Provision is made for a verificationmark to be applied. Descriptionof Variant 1 2. With a Mercury model 522 AL dial indicator (Figure 2) added to the subject to the Condition of Approval stated in the Certificate. instrument dial indicating mechanism is isolated from the lever mechanism by a pneumatic ram which locks the intermediateheackrork lever in a fixed position whenever the primary (digital) indicator is in use. The ram is autcmatically operated by a solenoid valve which responds to a signal from the computer (refer Figure 1) whenever an wauto-batching"sequence is canmenced. The 2.1 The Markings instrument is marked as per the pattern, and in addition: Minimum capacity (dial) Verificationscale intervals (dial) *These there. NW33 markings are repeated in the vicinity of each Min 1000 kg e=d * = 20 kg+ reading face if not already TEST PROCEDURE No 6/148/l 2 All lead applications to the instrument should be in accordance with the Cam& ssion's recomnended testing procedure for the eliminationof rounding error as set out in Document 104. The maximum permissibleerrors are: loads between 0 and 5OOe; loads between ,501e and 15OOe. 20.5e for t 1 ,Oe for 1. Zero Range that the range of the zero adjustment is not more than 4% of the maximum capacity (+-2% approximately). With zero balance indicated,apply a load of, say, 2.5% of maximum capacity to the instrument,and adjust the zero control; the instrument should not rezero. Check 2. (0) Zero Test Check by (Digitalindicatoronly) means of Docunent 104, that when the zero light is lit, zero is set within 0.25e. the automatic zero tracking device resets zero when the weighing mechanism is in equilibriumwithin 0.5 scale interval of zero, zero should be checked, with a load equal to, say, 10 scale intervals on the load receptor. The indicationswith 0.25e and 0.75e additionalmass on the load receptor will then be 1Oe and lie respectively. (b) As 3. Range 3.1 Digital Indicator (al maximum mass indicatedshould not exceed the maximum capacity (Max) by above this indicated mass the indicator than 10 scale intervals; should be blank. lb1 of Indication The more Below zero the indicationmay blank or the mass will be indicated, prefixed a minus sign. by 3.2 There 4. Dial Indicator shall be no stole marks below Test zero and above maximum capacity. Loads loads are to be applied to the complete weighing instrumentincreasing in not 5 approximatelyequal steps to maximum capacity, followed by decreasing loads in not less than 5 approximatelyequal steps to zero load. Test less 5. than Multiple Indicators one indicator is used, the variation between indications or same load shall not be greater than the absolute value of the maximum permissibleerror for that load on the device with the largest verification scale interval. Where more than printings for the Note: Condition of Approval stated in the Certificate. 25/3/88 NATIONAL - STANDARDS NOTIFICATION VARIOUS The following changes listed overleaf submitted - by CERTIFICATES OF APPROVAL are made to the approval and Technical The submittor should be changed A & D Mercury Pty Ltd (the address 2) OF CHANGE Mercury Weighing and Control 32 Dew Street SA 5031. Thebarton In the Certificates should be made: 1) COMMISSION remains documentation Systems Schedules for the approvals Pty Ltd listed, the following changes to read; unchanged) approved Mercury instrument or component of an instrument Any documentation, may now also be known as "AND Mercuryl or similar. in the Signed Executive Director ..../2 25/3/88 Paqe 2 Chanqe Notice APPROVAL PATTERN TYPE: weighing instruments Model 92 b/3/007 b/3/008 Model 131 counter scales TYPE: counter machines semi-self-indicating 6/4A/012 Model 304A TYPE: counter machines freely-suspended b/5/011 Model 211 DA TYPE: weighing 6/9~/001 6/9A/004 6/9A/007 6/9A/008 < 30 kg (spring scales) instruments non-self-indicating Models 692 and 682 Model 522D Model 211 Model 600 TYPE: weighing instruments self-indicating 6/9c/OO5 node1 211D 6/9c/O13 up to 2500 lb or 1200 kg 6/9C/O66 node1 522 AL node1 SM100/479/522D b/96/061 6/9C/O81 Model SE-LP 1200 6/9c/O88 Model 522D LT-1OK TYPE: Weighbridges self-indicating 6/10B/040 Model WB-LT 6/100/045A Model RVB-HZ0 TYPE: automatic weighing instruments (except belt conveyors) 6/14B/012 Model HSD automatic hopper TYPE: overhead b/18/005 b/18/017 TYPE : s114 siza S132 S161 s199 TYPE: s117 S163 s221 digital weighing instrument With 211DA headwork Model OHT 500 (suspended load or receptor) indicators Model 579 Model 1300 Model 900 Model AD4316 Model AD-4321 load cells Interface model SM25-12 kg Transducers model B5112.1K HBM model TRT-50 (Mercury model TRT3K-50)
© Copyright 2026 Paperzz