Vallox 1993A YK Control centre • 1.09.342 E • 24.10.2011 © VALLOX 255 Ventilation switch The ventilation switch is a rocker switch. • In position 1 ventilation is on 180 • In position 0 ventilation is off. 100 INSTRUCTIONS FOR INSTALLATION AND USE Use of the control centre WARNING If ventilation of a room is closed, it also prevents new, clean outdoor air from coming in to the house and dirty air from going out. Impurities emanating from human bodies, structures and the soil, such as carbon dioxide, humidity, smells, formaldehyde, dust and radon, quickly spoil indoor air and cause health damage. Too high a humidity may destroy the building structures and cause mould and fungus growth. Therefore, the building regulations require ventilation to be continually in operation and the level of ventilation to be adjusted as needed by the user. Installation Choosing control voltage 1. Open the fixing screws of the control centre cover. • You can choose maximum control voltage by moving the conductor between the transformer and relay R2 / connector 5 to the desired voltage option. Factory setting is 230 V. 2. Mark the locations for the fixing screws. 3. Fasten the control panel to the wall with the fixing accessories provided in the kit. (Fixing screws are suitable for wooden, chipboard, concrete and masonry walls; for other surfaces, use appropriate fixing accessories.) • You can choose minimum control voltage by moving the conductor between the transformer and relay R1 / connector 5 to the desired voltage option. Factory setting is 90 V. NOTE! Electrical connections must be carried out by an authorised person only. In case of failure with the control centre, contact the seller or manufacturer of the device. NOTE! In fans that are controlled with the control panel, a motor protector is needed. The maximum output of the fan is 600 W. © VALLOX • We reserve the right to make changes without prior notification. • You can choose half control voltage by moving the conductor between the transformer and relay R3 / connector 6 to the desired voltage option. Factory setting is 140 V. www.vallox.com CONTROL CENTRE 1993A YK ELECTRICAL CONNECTIONS Internal electrical connection / Control centre VALLOX 1993A YK L N M A X. N L2 L3 1 / 2 M I N. OPERATING STATUS DATA MAX. MAX. MIN. MIN. 1/2 1/2 I 0 4 4 12 8 8 MINIMUM VOLTAGE 3 7 11 10 3 7 11 2 2 10 6 100 V 90 V 130 V 110 V 160 V 140 V 230 V 5 200 V 6 1 9 MAXIMUM VOLTAGE 12 1 9 5 M 13 14 14 9 10 14 HALF VOLTAGE R1 11 13 R2 12 R3 5 13 1 6 2 8 3 7 4 Control centre VALLOX 1993A YK – VALLOX 70 Compact ventilation unit DISTRIBUTION PANEL N MAX. (230 V) 1/2 (230 V) MIN. (230 V) N 10A L REMOTE MONITORING 5 x 1.5 S OPERATION STATUS INDICATION (POTENTIAL-FREE) 6 x 0.5 3 x 1.5 S VALLOX 70 Compact N L N L1 I I I III 4 x 1.5 S L N N L2 L3 M A X. 1 / 2 M I N. OPERATING STATUS DATA MAX MAX MIN MIN 1/2 1/2 CONTROL CENTRE 1993A YK 8095703A © VALLOX • We reserve the right to make changes without prior notification. CONTROL CENTRE 1993A YK ELECTRICAL CONNECTIONS Control centre VALLOX 1993A YK – VALLOX 95/75 ventilation unit DISTRIBUTION PANEL REMOTE MONITORING 5 x 1.5 S N MAX. (230 V) 1/2 (230 V) MIN. (230 V) L 10A N OPERATION STATUS INDICATION (POTENTIAL-FREE) 3 x 1.5 S 6 x 0.5 VALLOX 95/75 N L L N N L2 M A X. L3 MAX MAX MIN MIN L 1 L1 N 2 L1 3 5 x 1.5 S OPERATING STATUS DATA M I N. 1 / 2 N 1/2 1/2 CONTROL CENTRE 1993A YK 8095704 Control centre VALLOX 1993A YK – VALLOX 132 E ventilation unit DISTRIBUTION PANEL L 5 x 1.5 S REMOTE MONITORING N N MAX. (230 V) 10A 1/2 (230 V) MIN. (230 V) OPERATION STATUS INDICATION (POTENTIAL-FREE) 6 x 0.5 3 x 1.5 S VALLOX 132 E N L 4 3 2 1 5 6 ... 4 x 1.5 S L N N L2 L3 M A X. 1 / 2 M I N. CONTROL CENTRE 1993A YK OPERATING STATUS DATA MAX MAX MIN MIN 1/2 1/2 7021300A © VALLOX • We reserve the right to make changes without prior notification. CONTROL CENTRE 1993A YK ELECTRICAL CONNECTIONS Remote monitoring control with control centre VALLOX 1993A YK – VALLOX roof ventilators DISTRIBUTION PANEL VALLOX ROOF VENTILATORS 15P-2-1, 20P-2-1 22P-2-1 N MAX. (230 V) 1/2 (230 V) MIN. (230 V) N 10A L REMOTE MONITORING 5 x 1.5 S N L N OPERATION STATUS INDICATION (POTENTIAL-FREE) L2 N 3 x 1.5 S L2 6 x 0.5 N W1 V1 U1 V2 U2 W2 VALLOX ROOF VENTILATOR 25P-4-1 L2 VALLOX ROOF VENTILATOR 31P-4-1 3 x 1.5 S W1 U1 L N N L2 L3 M A X. 1 / 2 M I N. U2 V1 V2 W1 OPERATING STATUS DATA MAX CONTROL CENTRE 1993A YK MAX MIN MIN 1/2 1/2 N L2 Vallox Oy FIN-32200 Loimaa Finland Telephone +358 10 7732 200 www.vallox.com www.vallox.com © VALLOX • We reserve the right to make changes without prior notification. 1.09342E/24.10.2011 PDF/Premedia Focus 8095705B
© Copyright 2026 Paperzz