BU LLETI N QD / SI L.000 CERTI FI ED PERFO RMAN CE DATA SDS 3.6 QUIET-DUCT SILENCERS TYPE: ML with FORWAR D and R EVE R S E FLOW Ratings IAC has produced Quiet-Duct HVAC silencers for more than 50 years, and has developed many of the terms and test standards for rating silencer performance that are used today. These standards are dynamic documents that continue to change based on new developments and discoveries in the field of acoustic engineering. Today we continue our involvement in several of the industry’s governing agencies, and we remain committed to ensuring that we are always providing product that is in accordance with all of the latest standards. All published acoustic and aerodynamic performance results are based on tests conducted in strict accordance with ASTM E477-99 in IAC America's NVLAP-Accredited laboratory. H DESIGNATING A SILENCER L W Model: 5 ML 36 x 18 Length: 5' Type: ML Width: 36" Height: 18" Table I. Dynamic Insertion Loss (DIL) Ratings: Forward (+) / Reverse (-) Flow IAC MODEL Octave Band Hz Face Velocity, fpm 1 63 2 125 3 250 4 500 5 1K 6 2K 7 4K 8 8K 3ML -5000 -2000 0 2000 5000 4 3 3 3 2 5 5 5 4 4 12 10 10 9 8 20 19 19 18 16 18 18 18 17 17 11 12 12 12 13 7 8 9 9 10 5 6 7 8 9 5ML -5000 -2000 0 2000 5000 6 5 5 4 3 9 8 8 7 6 18 16 15 14 14 32 31 31 30 28 32 31 31 30 29 17 17 19 20 22 9 10 12 13 13 6 7 9 10 11 7ML -5000 -2000 0 2000 5000 6 6 6 5 5 12 11 11 10 9 22 21 20 19 17 42 41 39 37 36 43 40 40 39 38 24 23 25 26 28 14 15 16 16 16 10 10 11 12 12 10ML -5000 -2000 0 2000 5000 9 8 8 7 7 18 17 16 15 15 28 27 26 25 23 46 47 46 45 44 47 50 50 49 50 34 33 35 36 36 19 20 20 20 21 11 12 12 12 14 (+) Forward Flow / (-) Reverse Flow. Aero-acoustic performance data based on NVLAP accredited laboratory tests conducted in strict accordance with ASTM E477-99. Contact IAC if attenuation in excess of 50 dB is required. IAC: MAKING THE WORLD A QUIETER PLACE 69 Table II: Weights and Measures Nominal Length W/ In H/ In 9 18 9 24 9 30 9 36 9 42 9 48 18 18 18 24 18 30 18 36 18 42 18 48 36 18 36 24 36 30 3 feet 5 feet 7 feet 10 feet Wt/ lb. 35 60 84 118 41 71 100 141 52 82 116 167 57 95 133 190 65 107 150 240 73 119 167 215 52 87 122 174 61 103 144 205 71 121 168 239 84 142 200 284 94 158 223 - 104 175 247 - 69 119.5 168.5 237.5 103 175 246 349 120 201 283 403 Nominal Length W/ In H/ In 36 36 36 42 36 48 54 18 54 24 54 30 54 36 54 42 54 48 72 18 72 24 72 30 72 36 72 42 72 48 3 feet 5 feet 7 feet 10 feet Wt/ lb. 138 239 337 475 153 265 374 - 168 291 411 - 121 206.5 290.5 411.5 164 278 390 554 191 322 451 642 222 381 537 759 247 423 597 - 272 466 658 - 138 239 337 475 206 350 492 698 240 402 566 806 276 478 674 950 306 530 748 - 336 582 822 - 0.24 0.28 0.36 0.44 0.28 0.34 0.42 0.52 0.33 0.40 0.50 0.61 0.38 0.46 0.58 0.71 0.44 0.53 0.66 0.82 0.50 0.60 0.75 0.93 0.57 0.68 0.85 1.05 0.64 0.76 0.95 1.18 0.71 0.85 1.06 1.31 0.78 0.94 1.18 1.45 Table III: Aerodynamic Performance Model L/ Ft 3 5 ML 7 10 Static Pressure Drop, i.w.g. 0.05 0.07 0.10 0.13 0.16 0.06 0.08 0.12 0.15 0.19 0.07 0.11 0.14 0.19 0.24 0.09 0.13 0.18 0.23 0.29 0.20 0.24 0.29 0.36 Silencer Face 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 Velocity, fpm Table IV: Self-Noise Power Levels, dB re: 10-12 Watts IAC Model Octave Band Hz Silencer Face Velocity, fpm 1 63 2 125 3 250 4 500 5 1K 6 2K 7 4K 8 8K -3,000 -2,000 -1,000 1,000 2,000 3,000 64 56 42 39 58 71 59 53 42 35 52 61 59 52 41 30 46 55 63 53 38 27 43 53 60 56 49 26 42 51 62 58 50 28 45 55 63 52 37 28 45 56 59 44 20 20 39 52 ML All Sizes (+) Forward Flow / (-) Reverse Flow. Aero-acoustic performance data based on NVLAP accredited laboratory tests conducted in strict accordance with ASTM E477-99. TAKE NOTE! THE IAC SNAP FORM • Silencer Face Area is the cross-sectional area at the silencer entrance. The IAC Snap Form helps evaluate the entire HVAC system and is now available on CD. The analysis starts with the acoustic criterion for the occupied space and then accounts for the system effects of each component such as terminals, mixing boxes, branch take-offs, elbows, ductwork, fan sources, plus room characteristics. Request a copy of the CD at [email protected] • Face Velocity is the CFM of airflow divided by the Face Area (in sq. ft.) • Pressure Drop for any velocity can be calculated from this equation: PD = (Actual FV/Catalog FV)2 x (Catalog PD) • Self Noise values shown are for a three-square-foot face area silencer. • For each doubling of the face area add 3 dB to the self-noise values listed. • For each halving of the face area subtract 3 dB from the self-noise values listed. • Weights and measures are listed for limited number of available sizes. 70 IAC America 1160 Commerce Avenue Bronx, New York 10462-5599 Tel: (718) 931-8000 Fax: (718) 863-1138 E-mail: [email protected] Web: www.IACsilencers.com Specially designed silencers and full-scale or model testing is available on request.
© Copyright 2026 Paperzz