ISO-9001:2000 certified SC Series Tuning Fork Liquid Level Switch More than just another level measurement company …. Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE FEATURES The SC series tuning fork level switch is suitable for detecting the presence and absence of liquids and solutions of a wide range of fluid materials. The principle of operation is based on changes in vibration frequency of the tuning fork when it comes in contact with the target fluid. The SC unit contains piezoelectric crystals to produce a vibration of the probe structure at its resonant frequency when free of the target material. When the fork probe comes into contact with the material the vibration is weakened/dampened and the frequency changes, which is detected by the SC unit's electronics and the switch electric output changes state. Ÿ Reliable and maintenance free solidstate technology with no moving parts Ÿ No calibration required unlike RF and capacitance based level switches Ÿ Fail-safe on power failure Ÿ Compact and standard versions with a choice of outputs for a wide range of applications and use Ÿ Universal 20-250VAC/VDC power supply available Ÿ Use with liquids have S.G. ³0.7 and up to 10,000cSt viscosity Ÿ Can be used for some dry freely flowing powders and small granular materials with bulk densities ≥ 4.4lbs/ft3 (0.07g/cm3) APPLICATIONS INDUSTRY USE Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ For material presence detection: Water/wastewater Food and ingredients Beverages Feed milling Chemical Petrochem Plastic production and processing Many others Ÿ Trigger an alarm or illuminate an indicating light Ÿ Close a valve to shutoff the filling of a vessel Ÿ Open a valve to discharge material from a temporary storage vessel For material absence detection: Ÿ Trigger an alarm or illuminate an indicating light Ÿ Close a valve to stop the discharge of material Ÿ Open a valve to begin filling vessel with material CONSTRUCTION FOR STANDARD TYPE (SC1400) Vibrating Fork Process Connection 1 Housing TYPES & SPECIFICATIONS COMPACT TYPE / STANDARD FORK Inch Inch Inch (mm) (mm) (mm) 4.49 (114) 0.984 (25) 0.984 (25) HEX38 1PT Max. ø1.06 9.84 (ø27) (250) 10.75 (273) 0.984 ø1.14 (25) (ø29) Non-extended Probe Extended Probe 10.16 (258) 0.984 (25) 1PT ø1.06 (ø27) Max. 0.906 (23) 0.787 (20) Model No. HEX38 4.13 (105) 4.13 (105) Type 4.49 (114) 4.49 (114) 10.67 (271) Dimensions ø1.50 (ø38) ø1.50 (ø38) ø1.50 (ø38) 0.984 (25) ø1.14 (ø29) 1PT ø1.06 Max. (ø27) 9.84 (250) 4.13 (105) 9.84 (250) 0.906 (23) 0.787 (20) Non-extended Probee 0.984 (25) HEX38 Extended Probe 0.906 (23) 0.787 (20) Non-extended Probe Extended Probe Compact / DIN Connector Compact / M12 Connector Compact / Prewired Cable SC2400/2410 SC2400/2410 SC2400/2410 Ambient temp. -40⁰F~140⁰F (-40⁰C~60⁰C) Process temp. -40⁰F~212⁰F (-40⁰C~100⁰C) or -40⁰F~302⁰F (-40⁰C~150⁰C) optional Wetted material 304SS, 316SS or 316LSS Pressure 580psi (40bar) Housing material 304SS Protection IP65 Conduit/ elec. conn. DIN 43650 Connector IP67 M12 Connector Prewired Cable(2m length, PVC jacket, 24AWG Vibrating frequency Supplyvoltage & output SC240: 20~250VAC/VDC with 2-wire (500mA Load Max.) SC241: 12~55VDC 3-wire (350mA Load Max.) Function test Output function test performed by applying magnet to test point on housing Minimum density 350~370Hz Liquids: S.G. ³ 0.7 / Solids: ³ 4.14lbs/ft 3 (0.07g/cm 3 ) £ 10,000cSt Liquid viscosity Indicators ø1.14 (ø29) Green LED: power on indication Red LED: On = switch closed / Off = switch open 2 TYPES & SPECIFICATIONS – COMPACT TYPE / MINI FORK Inch Inch Inch (mm) (mm) (mm) ø1.50 (ø38) ø1.50 (ø38) 4.37 (111) Dimensions 4.37 (111) 8.46 (215) 1.57 (40) HEX38 3/4PT Max. ø0.827 9.84 (ø21) (250) ø0.905 (ø23) 0.67 (17) 0.67 (17) Non-extended Probe 4.37 (111) 8.46 (215) 1.02 (26) 1.42 (36) ø1.50 (ø38) 1.42 (36) 1.57 (40) Extended Probe 7.99 (203) 1.02 (26) HEX38 3/4PT Max. ø0.827 9.84 (250) (ø21) 0.67 (17) Non-extended Probe ø0.905 (ø23) 1.02 (26) HEX38 3/4PT Max. ø0.827 9.84 (250) (ø21) 1.42 (36) 1.57 (40) 0.67 (17) Extended Probe 0.67 (17) 0.67 (17) Non-extended Probe Extended Probe Type Compact / DIN Connector Compact / M12 Connector Compact / Prewired Cable Model no. SC2800/2810 SC2800/2810 SC2800/2810 Ambient temp. -40⁰F~140⁰F (-40⁰C~60⁰C) Process temp -40⁰F~212⁰F (-40⁰C~100⁰C) or -40⁰F~302⁰F (-40⁰C~150⁰C) optional 304SS, 316SS or 316LSS Wetted material Pressure 580psi (40bar) Housing material 304SS Protection Conduit/ elec. conn. IP65 IP67 DIN 43650 Connector M12 Connector Prewired Cable(2m length, PVC jacket, 24AWG Vibrating frequency Supplyvoltage & output SC280: 20~250VAC/VDC with 2-wire (500mA Load Max.) SC281: 12~55VDC 3-wire (350mA Load Max.) Function test Output function test performed by applying magnet to test point on housing Minimum density 350~370Hz Liquids: S.G. ³ 0.7 / Solids: ³ 4.14lbs/ft3 (0.07g/cm3) £ 10,000cSt Liquid Viscosity Indicators Green LED: power on indication Red LED: On = switch closed / Off = switch open 3 ø0.905 (ø23) TYPES & SPECIFICATIONS – STANDARD TYPE Inch Inch ø4.45 (ø113) (mm) 4.25 (108) ø4.45 (ø113) Inch (mm) 1/2"NPTx2 (mm) ø4.45 (ø113) 4.25 (108) 1/2"NPTx2 0.787 (20) 4.25 (108) Dimensions 0.787 (20) 1"PT 1/2"NPTx2 1"PT 0.787 (20) 0.984 (25) 1" PT ø1.06 (ø27) 4.13 (105) ø1.14 (ø29) ø1.07 (ø27.2) 9.84~118.1 (250~3000) 5.12~9.84 (130~250) ø1.06 (ø27) ø1.06 (ø27) 4.13 (105) 4.13 (105) Type Standard Standard Ultra Extended Standard Extended Model no. SC1400 SC1410 SC1420 Ambient temp. 40⁰F~140⁰F (-40⁰C~60⁰C) Process temp. -40⁰F~266⁰F (-40⁰C~130⁰C) Wetted material 304SS, 316SS or 316LSS Pressure Housing material 580psi (40bar) Powder Coated Diecast Aluminum Protection IP65 Conduit/ elec. conn. Vibrating frequency Two (2) ½”NPT Conduit Entrances Supply voltage 350~370Hz 20~250VAC/VDC 50/60Hz Output Relay: One (1) or Two (2) SPDT 5A@250VAC/28VDC SSR (MOSFET): One (1) or Two (2) 400mA@60VAC/VDC Fail-safe Selectable High or Low Time delay Fixed: 0.6s to operate, 1~3s to reset Minimum density Liquids: S.G. ³ 0.7 / Solids: ³ 4.14lbs/ft3 (0.07g/cm3) Liquid Viscosity £ 10,000 cSt Sensitivity Adjustable Hi-Lo Potentiometer 4 Inch Inch (mm) (mm) ø4.45 (ø113) ø4.45 (ø113) 4.25 (108) 4.25 (108) 1/2"NPTx2 1/2"NPTx2 Dimensions 4.13 (105) Type Model no. 4.13 (105) Standard Corrosion Proof Standard Sanitary SC1540 SC1600 Ambient temp. -40⁰F~140⁰F (-40⁰C~60⁰C) Process temp. -40⁰F~266⁰F (-40⁰C~130⁰C) Wetted material Teflon Coated 316LSS 304SS, 316SS or 316LSS Mounting typel Flange Tri-Clamp 580psi (40bar) Pressure Housing material Powder Coated Diecast Aluminum IP65 Protection Conduit/elec. conn. Two (2) 1/2”NPT Conduit Entrances Vibrating frequency 350~370Hz Supply voltage 20~250VAC/VDC 50/60Hz Output Relay: One (1) or Two (2) SPDT 5A@250VAC/28VDC SSR (MOSFET): One (1) or Two (2) 400mA@60VAC/VDC Fail-safe Selectable High or Low Time delay Minimum density Fixed: 0.6s to operate, 1~3s to reset Liquids: S.G. ³ 0.7 / Solids: ³ 4.14lbs/ft3 (0.07g/cm3) £ 10,000 cSt Liquid Viscosity Sensitivity Adjustable Hi-Lo Potentiometer 5 TYPES & SPECIFICATIONS – EXPLOSIONPROOF TYPE NEPSI PROOF No.GYJ111212 Ex d IIC T3~T6 PTB PROOF No. 05 ATEX 1058 II 2G Ex d IIB T4 Gb II 2D Ex tb IIIC T80⁰C ~ T130⁰C Db IP65 Inch (mm) ø4.45 (ø113) 4.25 (108) 1/2"NPTx2 Dimensions 0.787 (20) 1" PT 4.13 (105) Type Model no. Ambient temp. Standard Ultra Extended Explosionproof Standard Explosionproof SC1740 SC1741 -40⁰F~140⁰F (-40⁰C~60⁰C) Process temp. -40⁰F~266⁰F (-40⁰C~130⁰C) Wetted material 304SS, 316SS or 316LSS 580psi (40bar) Pressure Housing material Powder Coated Diecast Aluminum Explosionproof / IP65 Protection Conduit/elec. conn. Two (2) 1/2”NPT Conduit Entrances Vibrating frequency 350~370Hz Supply voltage 20~250VAC/VDC 50/60Hz Output Relay: One (1) or Two (2) SPDT 5A@250VAC/28VDC SSR (MOSFET): One (1) or Two (2) 400mA@60VAC/VDC Fail-safe Selectable High or Low Time delay Minimum density Fixed: 0.6s to operate, 1~3s to reset Liquids: S.G. ³ 0.7 / Solids: ³ 4.14lbs/ft3 (0.07g/cm3) £ 10,000 cSt Liquid Viscosity Sensitivity Adjustable Hi-Lo Potentiometer 6 TERMINAL CONNECTIONS/ SENSITIVITY ADJUSTMENT – STANDARD TYPE SC1400X, SC1410X, SC1420X, SC1540X,SC1600X, SC1740X, SC1741X ONE SPDT Relay Output TWO SPDT Relay Outputs SENSITIVITY SENSITIVITY PWR SIGNAL FSL FSH L PWR H SIGNAL FSL FSH L H 20~250VAC 20~250VDC 20~250VAC 20~250VDC SPDT Type N- L+ Relay output type (DPDT) SSR(MOSFET) output type Relay output type(SPDT) RT2 RT1 NC COM NO DPDT Type RT2 RT1 N- L+ RT2 RT1 COM2 NC2 NO2 COM1 NC1 NO1 N- SSR(MOSFET) output type L+ RT2 RT1 2 2 1 1 N- L+ COM2 NC2 NO2 terminals not provided if ONE SPDT Relay is provided 2 _ 2 SSR (MOSFET) terminals not provided if ONE SSR (MOSFET) is provided TERMINAL FUNCTION PANEL FUNCTION L+, N-: Power Supply PWR: Power is on when illuminated (Green) SIGNAL: Output indication - Normal condition when illuminated (Red), Alarm condition exists when extinguished FSH: Fail-Safe High (refer to FAIL-SAFE HIGH / LOW PROTECTION Section for further information). FSL: Fail-Safe Low (refer to FAIL-SAFE HIGH / LOW PROTECTION Section for further information). SENSITIVITY L/H: Adjust sensitivity of sensing element using this potentiometer. Counterclockwise adjustment will DECREASE the sensitivity, Clockwise adjustment will INCREASE the sensitivity. NC1, COM1, NO1: Relay Output * NC2, COM2, NO2: Relay Output ** RT1, RT2: Remote Test :Ground Connection :1st SSR (MOSFET) Output :2nd SSR (MOSFET) Output† * If only one relay output is provided designation will be NC, COM, NO. ** Terminals exist only if the unit is specified and provided with two relay outputs. † Terminals exist only if the unit is specified and provided with two SSR (MOSFET) outputs. FAIL-SAFE HIGH / LOW PROTECTION (refer to illustrated table on page 8) FSH (Fail-Safe High) Protection: With the fail-safe switch in the FSH position: Normal condition: The SIGNAL LED is on, unit is NOT SENSING the target material, relay is energized and the output condition is opposite that shown in the terminal labels, i.e. NC is open, NO is closed. Power failure condition: When power to the sensor fails the SIGNAL LED is off, relay is de-energized and the output condition is as shown on the terminal labels, i.e. NC is closed, NO is open. This duplicates an Alarm condition for High level application where the SC unit is sensing the target material. FSL (Fail-Safe Low) Protection: With the fail-safe switch in the FSL position: Normal condition: The SIGNAL LED is on, unit IS SENSING the target material, relay is energized and the output condition is opposite that shown in the terminal labels, i.e. NC is open, NO is closed. Power failure condition: When power to the sensor fails the SIGNAL LED is off, relay is de-energized and the output condition is as shown on the terminal labels, i.e. NC is closed, NO is open. This duplicates an Alarm condition for Low level application where the SC unit is not sensing the target material. 7 SENSITIVITY ADJUSTMENT The SENSITIVITY adjustment potentiometer is located on the upper sight side of the panel inside the SC standard type enclosure. In general there is no need to adjust the SC sensitivity. However, if required during setup it is possible to make adjustments to the sensor sensitivity using a simple instrument screwdriver. The SC sensitivity is factory set at the maximum value. The switching point is approximately 0.591” (15mm) from the tip of the fork (vertical/top mounting orientation) based on an S.G. of 1.0. If desired, the switching point can be changed by adjusting the sensitivity of the SC. If you reduce the sensitivity by turning the potentiometer counterclockwise, the switching point will move further away from the tip of the fork (closer to the process connection, based on a vertical/top mounting orientation). If the sensitivity is increased by turning the potentiometer clockwise, the switching point will move closer to the tip of the fork (based on vertical/top mounting orientation). The maximum adjustment of the switching point, based on an S.G. of 1.0, will be approximately 2.36” (60mm). Example: based on a fluid with an S.G. = 1.0 and vertical / top mount orientation, if the switching point is 15mm based on the factory setting and it needs to be located 30mm further away from the tip of the fork, then the potentiometer is to be turned counterclockwise by about 10 full rotations or turns. Refer to page 9 for more information. FSL FSH Level Contact form NO COM NC NO COM NC NO COM NC NO COM Indication Status Fail Normal 8 Normal Fail NC WIRING CONNECTIONS – COMPACT TYPE SC240/280 2-WIRE AC/DC Min. 1 2 Max. 3 Brown Black Power Supply Wiring: Power supply is 20-250VAC/VDC connected to terminals/wires labeled L+ (Black wire for M12/Cable) and N- (Brown wire) as shown in Figure 1. PE shown in DIN and M12/Cable wiring diagram is “earth ground”. 4 Blue 1 Yellow Green 2 3 Brown Black N- L+ Min. (low): In the Min. / Low mode of operation the switch will be open when fluid is ABSENT at the sensor fork and closed when the fluid is PRESENT at the fork. Pin 1 (Brown wire in M12/cable) is connected to N-, and Pin 2 (Black wire) is connected to the N+ through the Load as shown. Pin 4 (Yellow/Green) is connected to the tank or earth ground (PE). 4 Blue Yellow Green N- L+ Figure 1 Two wires wiring Max. Min. Yellow Green Brown 1 Max. Min. Yellow Green Black 2 Brown 1 3 2 Black Blue Black Blue Black Brown Yellow Green Brown Yellow Green 3 Blue Blue PE N - L + PE N - L + PE N- Max. (high): In the Max. / high mode of operation the switch will be closed when fluid is ABSENT at the sensor fork and open when the fluid is PRESENT at the fork. Pin 1 (Brown) is connected to N-, and Pin 3 (Blue) is connected to Pin 2 (Black), which is then connected to N+ through the Load as shown. Pin 4 (Yellow/Green) is connected to the tank or earth ground (PE). L+ PE N- L+ DIN Wiring Diagram M12x1、Cable Wiring Diagram SC241/281 3-WIRE DC PNP Max. Min. 1 3 2 Blue Black Brown 1 3 2 Black 1 3 2 Black Yellow Green Brown 1 3 2 PNP Min. Black Blue Brown Yellow Green Black Blue Brown Yellow Green Black Blue Blue Blue R Brown Max. Min. Yellow Green Yellow Green Yellow Green Brown NPN Max. Max. NPN Black Blue Brown Yellow Green Min. Black Blue Brown Yellow Green R R PE N- L+ PE N- L+ PE L+ N- PE L+ N- PE N- L+ PE N- L+ PE L+ N- PE L+ N- M12x1、Cable Wiring Diagram Figure 2 PNP / NPN Output Wiring Diagram DIN Wiring Diagram Power Supply Wiring: Power supply is 12-55VDC connected to terminals/wires labeled L+ (Black wire for M12/Cable) and N- (Brown wire) as shown in Figure 2. PE shown in the DIN and M12/Cable wiring diagrams is “earth ground”. PNP Wiring: Min. (low): In the Min. / Low mode of operation the switch will be open when fluid is ABSENT at the sensor fork and closed when the fluid is PRESENT at the fork. Pin 1 (Brown wire in M12/cable) is connected to N-, and Pin 2 (Black wire) is connected to the N+. Pin 3 (Blue wire) is connected to N- through the Load as shown. Pin 4 (Yellow/Green) is connected to the tank or earth ground (PE). Max. (high): In the Max. / high mode of operation the switch will be closed when fluid is ABSENT at the sensor fork and open when the fluid is PRESENT at the fork. Pin 1 (Brown) is connected to N–, and Pin 3 (Blue) is connected to L+. Pin 2 (Black), which is then connected to N- through the Load as shown. Pin 4 (Yellow/Green) is connected to the tank or earth ground (PE). NPN Wiring: Min. (low): In the Min. / Low mode of operation the switch will be open when fluid is ABSENT at the sensor fork and closed when the fluid is PRESENT at the fork. Pin 1 (Brown wire in M12/cable) is connected to N+, and Pin 2 (Black wire) is connected to the N-. Pin 3 (Blue wire) is connected to N+ through the Load as shown. Pin 4 (Yellow/Green) is connected to the tank or earth ground (PE). Max. (high): In the Max. / high mode of operation the switch will be closed when fluid is ABSENT at the sensor fork and open when the fluid is PRESENT at the fork. Pin 1 (Brown) is connected to N+, and Pin 3 (Blue) is connected to L-. Pin 2 (Black), which is then connected to N+ through the Load as shown. Pin 4 (Yellow/Green) is connected to the tank or earth ground (PE). 9 ADJUSTMENTS/INDICATIONS – COMPACT TYPE SWITCHING POINT MAGNETIC TEST The switching point for the SC24 compact tuning fork level switch with the 105mm fork length is as shown in Figure 3. In a vertical orientation (top mounting), with a fluid having an S.G. = 1.0 (62.4lbs/ft3) the switching point is approximately 0.905”(23mm) from the tip of the fork. For fluid with an S.G. <1.0 (62.4lbs/ft3) the switching point distance from the tip of the fork will increase. Conversely, for a fluid with an S.G. > 1.0 (62.4lbs/ft3) the switching point distance from the fork tip will increase. The switching point for the SC28 compact tuning fork level switch with 40mm fork is 12mm (based on vertical orientation and fluid with S.G. = 1.0(62.4lbs/ft3), as shown in Figure 3. After the switch has installed and power tested, magnetic switch can be performed accordingly. Output status will switch from status of NO. to NC. or NC to NO. and red LED would indicate the vibration status by on / off. When magnet is pulled away from the housing, red LED would return as default while fork continues to vibrate. By this verification, user can confirm the wiring and function are correct or not. Testing point Magnet 3 S.G.< 1.0 (62.4lbs/ft ) Trigger Point moves upward S.G.<1.0 (62.4lbs/ft3) Trigger Point moves upward Sensing spot 10 mm Trigger point 3 S.G.> 1.0 (62.4lbs/ft ) Trigger Point moves downward 23mm S.G.>1.0 (62.4lbs/ft3) Trigger Point moves downward Figure 3 SC240/280 - Output/LED Status SC241/281 - Output/LED Status Min. (low) Mode: The SC240/280 is equipped with an AC/DC power supply and solidstate relay output that can be either open or closed. There is a 3 second delay in the activation of the SC unit when the power is initially applied, subsequent to this the relay switch is open and the red LED off. When the target material covers the fork, the vibration stops and the relay switch becomes closed and red LED is illuminated. Min. (low) Mode: The SC241/281 is equipped with a solidstate 3-wire DC PNP/NPN transistor output whose switch can be either open or closed. There is a 3 second delay in the activation of the SC unit when the power is initially applied, subsequent to this the transistor switch is open and the red LED off. When the target material covers the fork, the vibration stops and the transistor switch becomes closed and the red LED is illuminated. Max. (high) Mode: The SC240/280 is equipped with an AC/DC power supply and solidstate relay output that can be either open or closed. There is a 3 second delay in the activation of the SC unit when the power is initially applied, subsequent to this the relay switch is closed and the red LED is illuminated. When the target material covers the fork, the vibration stops and the relay switch becomes open and the red LED is off. Max. (high) Mode: The SC241/281 is equipped with a solidstate 3-wire DC PNP/NPN transistor output whose switch can be either open or closed. There is a 3 second delay in the activation of the SC unit when the power is initially applied, subsequent to this the transistor switch is closed and the red LED is illuminated. When the target material covers the fork, the vibration stops and the transistor switch becomes open and the red LED is off. Min. Mode Max.Mode Min. Mode Level Contactless electronic switch Max.Mode Level 1 2 Switch open 1 2 Switch closed 1 2 Switch closed 1 PNP/ NPN Output 2 Switch open Red LED Red LED 10 1 2 Switch open 1 2 Switch closed 1 2 Switch closed 1 2 Switch open INSTALLATION Horizontal Installation 1. Do not locate the SC series unit where the fork will be in the flow stream (Figures 1 and 3). 2. Keep the SC series fork protected to eliminate damage from falling material (Figure 1). 3. When installing the SC series unit to detect dry free flowing powder or small granular materials, always take into account the angle of repose of the material surface (Figure 1). 4. Do not install SC series unit near fluid flow inlet (Figure 1, 2 and 3). Vertical Installation 1. Based on the factory setting of the SC unit sensitivity, and a target fluid with an S.G. = 1.0, the switching point will be approximately 15mm from the tip for all Standard units (23mm for all SC24 Compact units, 12mm For all SC28 Compact units). 2. When installing in a horizontal pipe or other conduit, fork orientation should be such to allow the fluid to flow between the forks as shown below (Figure 4). 3. Do not install near or under material inlet flow (Figure 5). inlet inlet 20B 12 0m m Figure 1 Figure 2 Position hole inlet Position hole Position hole Figure 3 Figure 4 inlet Figure 5 11 ORDER INFORMATION – STANDARD TYPES SC Model No. 1400: 1410: 1420: 1540: 1600: 1740: 1741: Standard Ultra Extended (3000mm max.) Extended (250mm max.) Corrosion Proof Sanitary* Explosionproof Standard Explosionproof Ultra Extended * For Ultra Extended or Extended versions of Sanitary design, select Model 1410 or 1420 along with the Tri-Clamp process connection. Power & Output R: N: Q: M: One SPDT Relay, 20-250VAC/VDC One SSR (MOSFET), 20-250VAC/VDC Two SPDT Relays, 20-250VAC/VDC Two SSR (MOSFET), 20-250VAC/VDC Material (wetted parts) 0: 304SS 6: 316SS L: 316LSS Process connection Dimension C---3/4" D---1") E---1-1/2" F---2" G---2-1/2" H---3" I ---4" J ---5" K---6" S---Special Specification M---5kg/cm2 N---10kg/cm2 O---150 Lbs P---300 Lbs Q---PT R---PF(G) T---BSP U---NPT W---PN 10 X---PN 16 Y---PN 25 Z---PN 40 S---Special 9---Tri-Clamp* * 1-1/2” and 2” sizes only for Tri-Clamp sanitary type connection Length (unit:mm)* 0500: < 500 1000: 500~1000 1500: 1001~1500 2000: 1501~2000 2500: 2001~2500 3000: 2501~3000 * Manufactured Length will be ±0.197” (5mm) Preorder considerations 1. Please confirm your power supply voltage. 2. Please confirm your mounting orientation and location. 3. Please confirm the target material density, S.G or other units. 4. Do not install near any industrial vibrator mounted on wall of vessel. 5. Ensure material flow problems do not exist.. 12 ORDER INFORMATION – COMPACT TYPES SC (T) Model No. 24: Standard Fork (100mm) 28: Mini Fork (40mm) Power & Output 0: 2-Wire Solidstate Switch, 20-250VAC/VDC 1: 3-Wire PNP/NPN Switch, 12-55VDC Material (wetted parts) 0: 304SS 6: 316SS L: 316LSS Type 0: Non-extended Probe 1: Extended Probe High Operating Temperature (302⁰F/150⁰C) Electrical connection A: M12x1(180B) B: M12x1(90B) C: CABLE D: Valve plug DIN43650 (M12x1/ CABLE Wire length are 2M,PVC 24AWG) Process connection Dimension C---3/4" D---1" E---1-1/2" F---2" G---2-1/2" H---3" I ---4" J ---5" K---6" S---Special Specification M---5kg/cm2 N---10kg/cm2 O---150 Lbs P---300 Lbs Q---PT R---PF(G) T---BSP U---NPT W---PN 10 X---PN 16 Y---PN 25 Z---PN 40 S---Special 9---Tri-Clamp* * 1” and 1-1/2” sizes only for Tri-Clamp sanitary type connection Length (unit:mm)* Up to 0250 * Manufactured Length will be ±0.197” (5mm) Preorder considerations 1. Please confirm your power supply voltage. 2. Please confirm your mounting orientation and location. 3. Please confirm the target material density, S.G or other units. 4. Do not install near any industrial vibrator mounted on wall of vessel. 5. Ensure material flow problems do not exist.. 13 Global Network Germany China U.S. Taiwan U.S. Singapore Represented by: Aplus Finetek Sensor, Inc. 08-SC-B0-AP, 05/24/2016
© Copyright 2026 Paperzz