Litpak 369270 J-TB-095AB April 2014 Using the 500-mL Adapter for the JLA-8.1000 and JLA-9.1000 Rotors KIT CONTENTS 500-mL Adapter Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363683 contains Adapter, PET (polyethylene teraphthalate), qty/1 Adapter cap, polycarbonate, qty/1 Adapter O-rings, silicone, qty/2 (replacement part number 970883) DESCRIPTION The patented* 500-mL adapter (see Figure 1) for the Beckman Coulter JLA-8.1000 and JLA-9.1000 rotors enables the use of 500-mL, 250-mL, 50-mL, and 15-mL bottles and tubes, and Bio-Vials, in these rotors. Labware smaller than 500 mL must be placed in another adapter, or more than one other adapter, before being placed in the 500-mL adapter. See Table 1 for a list of bottles, tubes, and adapters that can be used. Adapter Cap Adapter O-rings (970883) Adapter Body Figure 1. The 500-mL Adapter for the JLA-8.1000 and JLA-9.1000 Rotors * U.S. patent no. 5,901,873 © 2002—2014 Beckman Coulter, Inc. INSTRUCTIONS These instructions describe use of the 500-mL adapter assembly only. For complete information on use and care of the JLA-8.1000 and JLA-9.1000 rotors, see the rotor manual (publication J-TB-073). 1. Prepare the 500-mL adapter by making sure that the two O-rings are in place as shown in Figure 1. Do not lubricate the O-rings. 2. Fill and seal the bottles or tubes to be used in the 500-mL adapters. 3. If 500-mL bottles are used, place each bottle directly into a 500-mL adapter. For bottles of different sizes, first load the bottles into the adapters listed in Table 1 and then place the filled bottle/adapter assembly into the 500-mL adapters. Do not load sample directly into the 500-mL adapter. 4. Place the adapter cap on the adapter, push down, and twist. The bottom edge of the adapter cap will not touch the top of the adapter, but the assembly is sealed by the O-rings and will seal completely during centrifugation. 5. Hold the adapter by the adapter body, not by the adapter cap, and place the filled adapter into a JLA-8.1000/JLA-9.1000 rotor cannister. No special orientation of the adapter in the cannister is required. Make sure that six filled cannisters are loaded in the JLA-8.1000 rotor, or four cannisters in the JLA-9.1000 rotor, prior to centrifugation. 6. After centrifugation, remove the 500-mL adapters from the cannisters by grasping each adapter cap top and pulling up until you can grasp the adapter body. Then, holding the adapter body, remove the adapter completely and set it on a flat surface. 7. To remove the adapter cap, hold the adapter firmly in one hand and, with the other hand, twist and lift off the cap. Placing your fingers in the indentations in the adapter may help you to grip the adapter tightly. Some users may find the adapter caps difficult to remove. To facilitate removal, a rubber gripping tool is available. This tool holds the adapter in place on a flat surface, leaving both of the user’s hands free to remove the cap. The grip is contained in Tool Kit 366770, which may be ordered from Beckman Coulter. MAINTENANCE Cleaning Clean the adapters and adapter caps using a mild detergent, such as Beckman Solution 555. Rinse and dry thoroughly. The O-rings may be left in place during cleaning unless leakage has occurred, in which case you should remove the O-rings with a hemostat or similar instrument and thoroughly wash and dry them before replacing them on the adapter. Do not lubricate the O-rings. Decontamination If components are contaminated with radioactive, toxic, or pathogenic materials, follow appropriate decontamination procedures as outlined by your laboratory safety officer. 2 Table 1. Available Tubes and Bottles for Use in the 500-mL Adapter for the JLA-8.1000 and JLA-9.1000 Rotors. Use only the items listed here and observe fill volumes and maximum run speeds. Tube Dimensions and Volume a Description Required Accessory Part Number Max Fill Vol a (mL) Description Part Number Max Speed b/ RCFc 69 × 160 mm 500 mL polycarbonate bottle w/cap assy 355605 465 none — 9 000 rpm 15 900 × g 69 × 160 mm 500 mL polypropylene bottle w/cap assy 355607 445 none — 8 000 rpm (both rotors) 15 200 × g 69 × 160 mm 500 mL polycarbonate bottle w/screw-cap 355664 465 none — 9 000 rpm 15 900 × g 69 × 160 mm 500 mL polypropylene bottle w/screw-cap 355665 445 none — 5 000 rpm (both rotors) 5 900 × g (JLA-8.1000) 4 900 × g (JLA-9.1000) 62 × 120 mm 250 mL polypropylene wide mouth bottle w/cap assy 356011 250 adapter 362750 (PET) 9 000 rpm 16 800 × g 62 × 120 mm 250 mL polycarbonate wide mouth bottle w/cap assy 356013 250 adapter 362750 (PET) 9 000 rpm 16 800 × g 29 × 104 mm 50 mL polycarbonate bottle assy w/liquidtight cap assy 357000 45 adapter 356996 (polypropylene) 9 000 rpm — 29 × 104 mm 50 mL polycarbonate bottle w/screw cap 357002 40 adapter 356996 (polypropylene) 9 000 rpm — 29 × 104 mm 50 mL polypropylene bottle assy w/liquid-tight cap assy 357001 45 adapter 356996 (polypropylene) 9 000 rpm — 29 × 104 mm 50 mL polypropylene bottle w/screw cap 357003 40 adapter 356996 (polypropylene) 9 000 rpm — 29 × 104 mm 50 mL polypropylene thickwall tube w/snap-on cap 357005 36.5 adapter 356996 (polypropylene) 9 000 rpm — natural 29-mm cap red 29-mm cap green 29-mm cap yellow 29-mm cap blue 29-mm cap 356264 d 357359 d 357360 d 357361 d 357362 d Above 20°C fill polypropylene tubes at least half full. Continued — b Maximum speeds listed are guidelines only. These speeds have been achieved in reliability tests at Beckman Coulter, but, because of manufacturing variances, no guarantee of performance or fit is expressed or implied. c Maximum speeds and g-forces listed are for the JLA-9.1000 rotor except as noted. The maximum speed of all components in the JLA-8.1000 rotor is 8000 rpm except as noted. d Polypropylene; package of 25. 3 Table 1. Available Tubes and Bottles for Use in the 500-mL Adapter for the JLA-8.1000 and JLA-9.1000 Rotors (continued) Tube Dimensions and Volume a Description Part Number Max Fill Vol a (mL) Required Accessory Description Part Number Max Speed b/ RCF 29 × 104 mm 50 mL polypropylene thickwall tube, no cap 357007 50 adapter 356996 (polypropylene) 9 000 rpm — 29 × 104 mm 50 mL polycarbonate open-top tube 363647 40 adapter 356996 (polypropylene) 9 000 rpm — 29 × 104 mm 50 mL polycarbonate tube w/snap-on cap 363664 40 adapter 356996 (polypropylene) 9 000 rpm — 17 × 119 mm 15 mL conical polypropylene open-top tube 355663 15 adapter 356960 (polypropylene) 6 500 rpm (both rotors) — Bio-Vials 14 × 55 mm 4 mL polypropylene, capped 566353 4 adapter 342098 (delrin) and 362750 (PET) 9 000 rpm — Above 20°C fill polypropylene tubes at least half full. b Maximum speeds listed are guidelines only. These speeds have been achieved in reliability tests at Beckman Coulter, but, because of manufacturing variances, no guarantee of performance or fit is expressed or implied. c Maximum speeds and g-forces listed are for the JLA-9.1000 rotor except as noted. The maximum speed of all components in the JLA-8.1000 rotor is 8000 rpm except as noted. d Polypropylene; package of 25. Sterilization and Disinfection • Ethanol (70%)† may be used on all components. See Appendix A in Rotors and Tubes for Beckman Coulter Avanti J, J2, and J6 Series Centrifuges (publication JR-IM), or publication IN-175, for more information regarding chemical resistances of rotors and accessories. • The adapter, adapter cap, and O-rings can be autoclaved at 121°C for 15 minutes. Repeated autoclaving will reduce the life of these components. For this reason, cold sterilization methods are recommended. While Beckman Coulter has tested these methods, no guarantee of sterility or disinfection is expressed or implied. When sterilization or disinfection is a concern, consult your laboratory safety officer. † Flammability 4 hazard. Do not use in or near operating centrifuges. Trademarks Beckman Coulter, the stylized logo, and Avanti are trademarks of Beckman Coulter, Inc. and are registered in the USPTO. All other trademarks, service marks, products, or services are trademarks of their respective holders. 5 Beckman Coulter, Inc. • 250 S. Kraemer Blvd. • Brea, California 92821 U.S.A. Sales and Service: 1-800-742-2345 • Internet: www.beckmancoulter.com • Printed in U.S.A. © 2014 Beckman Coulter, Inc. All rights reserved
© Copyright 2026 Paperzz