XT546-246-346 selec TERMINAL CONNECTIONS LOAD CONNECTIONS XT546 OP288-V03 Operating Instructions For load current less than 0.5A XT246 L L + - N NO1 6 COM 2 7 RST 3 8 11 - N START COM1 72x72 : Dual, 3 digit seven segment LED display : 85 to 270V AC, 50/60 Hz 24V AC / DC (Optional) Operating : On Delay, Interval, Cyclic On first & Modes Cyclic Off first Time Ranges : 9.99 / 99.9 / 999sec 9.59 min:sec, 99.9 / 999 min, 9.59 hour:min, 99.9 / 999 hour Counting : Down Direction Relay Rating : 5A@250V AC / 28V DC Start Input : Pulse, Gate (Programmable) Reset : On interruption of power, front panel reset & Outputs Memory Retention Accuracy 5 10 12 NC2 N COM RST 4 11 XT XT C 12 13 NC1 7 14 terminal reset : 2 ; 1 C/O (SPDT) : 10 years XT346 COM MOV C R C MOV C Snubber NO2 NO2 RST 11 1 2 LOAD FRONT PANEL DESCRIPTION NC2 13 14 15 16 17 18 4 3 4 5 6 7 8 9 3 On line For installing the Timer 1. Prepare the panel cutout with proper dimensions as shown below : Outline Panel cutout Dimensions (in mm) Dimensions (in mm) D F B (Whichever is greater) MODELS XT546 DIM C E PROG 2 LCK RST Config Lock Parameter name Parameter setting 2 Set Time 3 O/P Status ( Lit when O/P is ON ) 4 Time Range ( Blink in online mode ) For Reset NOTE : Press + (LCK) key together continuously for 3sec. to enter into protection level. Panel Cutout : Setting : ± 0.05% of set time or 50 msec Repeat : ± 0.05% Temperature : Operating : 0 to 50OC Storage : -20 to 75OC Humidity : 95% RH Housing : PC tinted black Weight : XT546 : 140 gms XT246 : 190 gms XT346 : 240 gms R Process Time PROTECTION LEVEL Side view H M S SET MECHANICAL INSTALLATION Front bezel XT546 NC1 NO1 COM1 A C Snubber COM2 NC2 12 N L NO COM2 START 10 Contactor XT LOAD NO selec SPECIFICATIONS Display Supply 9 10 6 96x96 NC1 2 3 5 9 L XT COM1 COM2 4 For bigger loads, use interposing relay / contactor N R NO2 NO1 48x48 START 8 1 + 1 L G A B C D E F G 48 48 94 45 4 46 46 XT246 72 72 83.7 67 10 69 69 XT346 96 96 73 90.5 10 92 92 2. Remove the clamp from the controller and push the controller into the panel cutout. Insert the clamp from the rear side until the main is securely fit into the panel. Set time Lock Use (any of 3) to select set time LOCK & UNLOCK Default : UNLOCK Config. Lock Use (any of 3) to select config. LOCK & UNLOCK Default : UNLOCK The unit will auto exit lock mode after 30sec. of key inactivity or by pressing + ( LCK ) keys continuously for 3sec. to exit the function. Doc. Name : Operating/1112/XT546/246/346 OP288-V03 (Page 1 of 2) Set key Output Modes Time Range Note : The decimal Point of 3rd digit blinks till correct Lock code entered. Use key [any of 3] to scroll through the various modes. Default : ON Delay Use key [any of 3] to scroll through the various time range. Default : 99.9sec The unit will auto exit reset mode after 1sec. TO PROGRAM SET VALUE Note : Press key to change the set value. The corresponding digit will increment from 0 to 9 and then will roll over back to 0. Press key to store set value Only if mode selected is on delay / Interval NOTE : Press key to store set value. Decimal point of 3rd digit blink still the storage of set value Set 3rd digit Set 2nd digit t t t t Start Reset Output Cyclic ON t1 t2 t1 t2 t1 t2 t2 t1 t2 t1 t2 t1 Typical application of Continuous start and reset in On delay mode : t : Set time Supply Start Reset Output On delay Use key [any of 3] to select yes or no Default : Yes NOTE : Press key to store set value. Decimal point of 3 digit blinks till the storage of set value Power on reset Use key [any of 3] to select yes or no Default : NO Set 3rd digit Front panel reset t t Typical application of Gate start Supply rd NOTE : If the set value is 000 then timer must hold (not work). All indications will be OFF. The unit will auto exit set value mode after 30sec. of key inactivity USER GUIDE t Output Cyclic OFF keys to register and move to next parameter Set 2nd digit Set 1st digit NOTE : Press t Output Interval Supply Start Use key [any of 3] to select yes or no Default : NO Start Output ON Delay t1 : ON time ; t2 : OFF time Use key [any of 3] to select gate or pulse. Default : Gate Default Supply t : Set time 2. Cyclic ON first, Cyclic OFF first modes : Set 1st digit ! Use key [any of 3] to scroll through the various ranges. ! In Cyclic ON function, also first OFF time is set and then ON time is set. ! H, M, S indication will indicate the time range. 1. On delay, Interval modes : Reset Only if mode selected is cyclic NOTE : This parameter is prompted only if mode selected is cyclic. MODE OF OPERATION Reset Set 3rd digit Prompt only if configuration Lock enabled in PROTECTION LEVEL Lock code = 85 [Fixed] NOTE : Press + (RST) key together continuously for 5sec. to enter into function. Set 2nd digit The unit will auto exit program mode after 30sec. of key inactivity or by pressing + (PROG) key together continuously for 3sec. RESET METHOD Set 1st digit CONFIGURATION INSTRUCTION 1. Enter configuration by pressing the key + (PROG) key together for 3 sec. 2. Scroll various function ranges by pressing key(any of 3) 3. Scroll various parameter by pressing the key. START : Pulse / Gate A) Pulse : Timing starts on momentary closure of switch connected between START and COMMON terminals. B) Gate : Timing starts at power on. When the START and COMMON terminal is closed timing freezes and it resumes only when the shorting is opened. Gate th = hold time ; t1 + t2 = t Reset (set time) Output On delay t t1 th t2 ( Specifications are subject to change, since development is a continuous process ) Selec Controls Pvt. Ltd. Tel. No. : +91-22-40394200 / 40394202 Fax No. : +91-22-28471733 I Toll free : 1800 227 353 Website: www.selec.com I Email : [email protected] Doc. Name : Operating/1112/XT546/246/346 OP288-V03 (Page 2 of 2)
© Copyright 2026 Paperzz