ANALYSIS OF CORROSION FATIGUE FOR COMMERCIALLY PURE TITANIUM USING NITROGEN ION IMPLANTATION NURDIN ALI A thesis submitted in fulfillment of the requirement for the award of the Doctor of Philosophy Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia APRIL 2014 v ABSTRACT The objective of this research is to determine the corrosion fatigue behaviours for commercially pure titanium (CpTi) using nitrogen ion implantation. A series of studies was conducted to obtain the mechanical properties, corrosion resistance and fatigue and corrosion fatigue behaviours and to develop model prediction of corrosion fatigue life of nitrogen ion implanted CpTi (Nii-Ti). Initially, nine specimens of CpTi were implanted nitrogen ion with the energy of 80, 100 and 115 keV and dose of 0.5x1017, 1.0x1017 and 2.0x1017ions/cm2 to characterize its surface properties and to obtain corrosion resistance. The result shows that energy of 100 keV and dose of 2.0x1017ions/cm2 was the optimal implanted parameter. In the second study, fatigue and corrosion fatigue test were performed to investigate the fatigue and corrosion fatigue behaviours. The fatigue specimens were implanted with the energy of 100 keV and dose of 2.0x1017ions/cm2. The fatigue tests were carried out for Nii-Ti specimens in saline solution and for CpTi and Nii-Ti specimens in laboratory air by means of axial loading condition at stress level between 240 and 320 MPa. The results were nitrogen ion implantation improved slightly the fatigue life of CpTi and Nii-Ti with the fatigue strength of 250 MPa and 260 MPa, respectively. Finally, the prediction of corrosion fatigue life was developed based on corrosion pit growth law. The stress amplitudes of 250, 260 and 280 MPa were selected to measure penetration rate of specimens at various elapsed times using electrochemical method in saline solution, then established the empirical model. The result shows that the expression fits the experimental data well. In conclusion, the effects of nitrogen ion implantation on surface properties and adhesion strength of nitride layers improved the fatigue and corrosion fatigue life of Nii-Ti. vi ABSTRAK Objektif kajian ini ialah untuk menentukan tingkah laku lesu kakisan untuk titanium komersil murni (CpTi) menggunakan nitrogen ion implantasi. Satu siri kajian telah dijalankan untuk menentukan sifat-sifat mekanikal, rintangan kakisan, kelesuan dan tingkah laku lesu kakisan dan membangunkan pengiraan daripada model hayat lesu kakisan CpTi setelah ditanamkan ion nitrogen (Nii-Ti) Dalam kajian awal, sembilan spesimen CpTi yang telah ditanamkan ion nitrogen dengan tenaga 80, 100 dan 115 keV dan dose 0.5x1017, 1.0x1017 dan 2.0x1017ions/cm2 untuk ciri-ciri sifat permukaan dan rintangan kakisan. Hasil kajian menunjukkan bahawa tenaga 100 keV dan dose 2.0x1017ions/cm2 adalah parameter optimum penanaman itu. Dalam kajian kedua , ujian lesu dan kakisan lesu telah dijalankan untuk melihat lesu dan hayat lesu kakisan. Spesimen lesu telah pun ditanam ion nitrogen dengan tenaga 100 keV dan dose 2.0x1017ions/cm2. Ujian lesu dengan dijalankan bagi spesimen CpTi dan Nii-Ti dalam persekitaran makmal dan ujian lesu kikisan untuk spesimen Nii-Ti dalam larutan masin dengan keadaan beban paksi dalam julat tegasan antara 240 MPa. dan 320 MPa. Berdasarkan kajian ini didapati bahawa penanaman ion nitrogen meningkat sedikit hayat lesu CpTi dan Nii-Ti dengan kekuatan lesu masing-masing iaitu pada 250 MPa dan 260 MPa. Dalam kajian akhir terhadap angaran hayat kakisan lesu telah dibangunkan berdasarkan hukum pertumbuhan kakisan lubang. Amplitud tegasan 250 MPa, 260 MPa dan 280 MPa telah dipilih untuk melihat kadar penusukan yang terjadi terhadap specimen Nii-Ti pada pelbagai masa berlaku mengunakan kaedah elektrkoimia dalam larutan masin; kemudian menubuhkan model empirik bagi anggaran hayat kakisan lesu. Keputusan kajian menunjukkan, pengiraan dan ujikaji boleh dibandingkan dan bersesuian juga. Sebagai kesimpulan, kesan penanaman ion nitrogen pada sifat-sifat permukaan dan ketegasan lekatan lapisan nitrida boleh meningkatkan hayat lesu dan hayat lesu kakisan Nii-Ti. vii TABLE OF CONTENTS TITLE DECLARATION DEDICATION CHAPTER 1 ACKNOWLEDGEMENT iv ABSTRACT v ABSTRAK vi TABLE OF CONTENTS vii LIST OF FIGURES xii LIST OF TABLES xvi LIST OF SYMBOLS AND ABBREVIATIONS xvii LIST OF APPENDICES xx INTRODUCTION 1 1.1. Background of research 1 1.2. Problem statements 2 1.3. Objective 3 1.4. Scope of research 3 viii CHAPTER 2 1.5. Contributions of research 4 1.6. Thesis organization 4 LITERATURE REVIEW 6 2.1 Titanium in biomedical applications 6 2.2 Mechanical Loading imposed on an implant device 2.3 in human body 9 Ion implantation technique for surface modification 11 2.3.1 Review of ion implantation technique 12 2.3.2 Theoretical prediction of penetration depth 15 2.3.3 Surface modification of CpTi by nitrogen ion implantation 2.4 2.5 2.6 15 Corrosion effects associated with biological environment 17 2.4.1 Corrosion forms of pure titanium 17 2.4.2 Effect of nitrogen ion implantation on corrosion resistance of titanium 19 Fatigue and corrosion fatigue of metals 20 2.5.1 Mechanism of corrosion-fatigue 23 2.5.2 Stress -life approach in corrosion fatigue 23 2.5.3 Crack initiation in corrosion fatigue 25 2.5.4 Crack propagation in corrosion fatigue 28 Trends in fatigue of titanium in various environment 31 2.6.1 32 Fatigue of titanium in laboratory air ix 2.6.2 Corrosion fatigue of titanium in SBF environment 2.7 Trends in corrosion fatigue modeling 34 2.8 Fatigue life prediction under various environment 35 2.8.1 Prediction of fatigue life under laboratory air environment 2.8.2 2.9 36 Prediction of crack initiation life under corrosion fatigue CHAPTER 3 33 Summary of literature review 37 38 METHODOLOGY OF RESEARCH 39 3.1 Materials 39 3.2 Experimental procedures 41 3.2.1 Preparation of specimen for ion implantation 41 3.2.2 Nitrogen ion implantation process 43 3.2.3 Nitride phase observation 44 3.2.4 Surface hardness evaluation 45 3.2.5 47 Electrochemical studies 3.3 Tensile properties test and wear resistance evaluation 51 3.4 Fatigue testing in laboratory air and in saline solution 53 3.5 Prediction of corrosion fatigue life 58 3.6 Development of corrosion fatigue testing method 61 3.6.1 Corrosion chamber 3.6.2 Justification of fatigue test specimen 62 dimension 64 3.7 Summary of research methodology 66 x CHAPTER 4 RESULTS AND DISCUSSION 67 4.1 67 4.2 Analysis of surface properties 4.1.1 Formation of nitride phase 67 4.1.2 Surface hardness assessment 74 4.1.3 Corrosion behaviour of Nii-Ti 77 4.1.4 Assessment of Nii-Ti surface properties 85 4.1.5 Tensile properties and wear resistance 87 Fatigue and corrosion fatigue of CpTi and Nii-Ti 4.2.1 Fatigue of CpTi and Nii-Ti 4.2.2 S-N curve of Nii-Ti in laboratory air and in 93 4.2.3 Formulation of stress-cycle relationship 95 4.2.4 Fracture surface analysis of failure specimen 96 4.2.5 Scheme of crack geometry at fracture Corrosion fatigue behaviour of Nii-Ti 4.3.1 4.3.2 100 100 Corrosion behaviour of Nii-Ti during corrosion fatigue 4.5 99 Characteristics of corrosion rate during corrosion fatigue 4.4 92 saline solution surface 4.3 92 Fatigue life prediction 105 108 4.4.1 Fatigue life prediction of Nii-Ti 108 4.4.2 Prediction of corrosion fatigue life of Nii-Ti 109 Summary of results and discussion 112 xi CHAPTER 5 CONCLUSIONS AND RECOMMENDATIONS 114 5.1 Conclusions 114 5.2 Recommendations 116 REFERENCES 117 APPENDICES 129 VITA 156 xii LIST OF FIGURES FIGURE 2.1 TITLE PAGE Examples of titanium application: (a) artificial hip joint (b) bone plate implant and (c) hip replacement 2.2 8 Schematic illustration of a cross-section of a deformed metallic biomaterial surface showing the complex interactions between the material’s surface and the physiologic environment 11 2.3 Schematic of an ion implantation system 13 2.4 Schematic of the ion implantation process 13 2.5 Schematic view of the path of an individual ion in process of ion implantation 2.6 Cross-sectional illustration of thin film and surface-modified layer formation 2.7 14 17 Theoretical conditions of corrosion, immunity and passivation of titanium 18 2.8 Schematic illustration of cyclic loading parameters 21 2.9 Schematic description of total fatigue life and its relevant factors 22 2.10 Schematic description of total corrosion fatigue life 26 2.11 Corrosion pit formation mechanism and fatigue crack initiation of CpTi in saline solution 27 2.12 Typical fatigue crack growth rate behaviour 30 2.13 S-N curve of CpTi of untreated and sandblasted samples 33 3.1 Flow chart of research methodology 40 3.2 Grinding and polishing machine for sample preparation 42 3.3 Form and shape of the specimen prior to preparation process 43 xiii 3.4 Cockcroft-Walton accelerator Type 200 keV/200 μA 44 3.5 X-Ray diffraction-BRUKER D8 ADVANCE 45 3.6 Vickers hardness test procedure 46 3.7 Hardness testing repetitions 47 3.8 Shimadzu Hardness Micro Vickers tester 47 3.9 Shape and form of specimen for electrochemical study 48 3.10 Electrochemical test set up 49 3.11 Apparatus of corrosion test WPG 100, WonATech 50 3.12 Dimension of wear test specimen 52 3.13 Pin-on Disc wear tester 20LE 53 3.14 Shape and dimension of the fatigue specimen according to ASTM 1801-97 54 3.15 Machining procedure of fatigue specimen 55 3.16 Flow chart of the machining process of fatigue specimen. 56 3.17 Shimadzu SERVOPULSER 100 kN fatigue machine 57 3.18 Set up of corrosion fatigue testing 58 3.19 Apparatus set up for corrosion test of corrosion fatigue specimen 59 3.20 Flowchart of corrosion fatigue behaviour modeling 60 3.21 Scanning Electron Microscope (SEM) JSM-61180LA 61 3.22 Drawing of the corrosion chamber 62 3.23 Corrosion chamber for current test (a) before installed position and (b) in loading condition 3.24 Specimen with the diameter gage of 7 mm failed at the grid section 3.25 63 64 Specimen failure due to buckling for stress amplitude of 280 MPa and 300 MPa. 65 3.26 An example of the specimen used for current study 65 3.27 Specimen of fatigue failure 65 xiv 4.1 Spectrograph for Nii-Ti with (a) 0.5x1017 ions/cm2 dose and (b) 2.0x1017 ions/cm2 dose 4.2 69 XRD patterns for the original and implanted CpTi (a) at different energies, (b) at different doses and (c) the verification of unit cell formation 4.3 71 The projected range (Ri) of nitrogen ion implantation with different energy: (a) energy of 80 keV (b) energy of 100 keV, and (c) energy of 115 keV 73 4.4 Effect of beam energy on penetration depth 73 4.5 Surface hardness of CpTi and Nii-Ti, (a) effect of dose; and (b) effect of energy on surface micro-hardness 4.6 Tafel polarization curves of CpTi and Nii-Ti in 3.5% NaCl at (a) different doses and (b) different energies 4.7 80 Potentiodynamic polarization curves of CpTi and Nii-Ti in saline solution at different energies and doses 4.8 77 84 Curve of hardness vs corrosion rate (a) in 3.5% NaCl (b) in SBF solution 86 4.9 Microstructure of CpTi in original condition 88 4.10 Stress-strain relationships of CpTi and Nii-Ti 90 4.11 Wear resistance surface of CpTi and Nii-Ti with energy of 100 keV and dose 2.0x1017ions/cm2 4.12 S-N curves of CpTi and Nii-Ti in compare with the work of Fleck & Eifler 4.13 94 Log-log plot of S-N curve for obtaining the Wöhler’s and Basquin’s formula 4.15 93 S-N curve of CpTi and Nii-Ti in laboratory air and in saline solution 4.14 91 96 SEM image of CpTi specimen tested at 260 MPa in laboratory air showing (a) overview of the fracture surface, (b) specimen surface crack initiation, (c) transgranular crack initiation and propagation 97 xv 4.16 SEM image of Nii-Ti specimen tested at 280 MPa in laboratory air showing (a) overview of the fracture surface (b) fatigue-crack and propagation (c) transgranural crack initiation and granular crack propagation 4.17 98 SEM image of Nii-Ti specimen tested at 280 MPa in saline solution showing (a) overview of the fracture surface (b) corrosion pit formation, fatigue-crack and propagation (c) specimen surface corrosion 4.18 Scheme of the crack geometry at surface of Nii-Ti 4.19 Polarization curves of corrosion fatigue specimen tested at the 99 100 stress, (a) 250 MPa (b) 260 MPa and (c) 280 MPa. 102 4.20 Penetration rate as a function of time. 104 4.21 Variation of experimental constant as a function of stress amplitude 105 4.22 Corrosion rate versus elapsed time in saline solution 106 4.23 Variation of Ecorr as a function of elapsed time 107 4.24 Variation of current density (icorr) as a function of elapsed time 107 4.25 S-N curves of experimental and analytical data for Nii-Ti 108 4.26 S-N curves of corrosion fatigue initiation life of model and corrosion fatigue life obtained by experimental work 4.27 111 S-N curves of predicted corrosion fatigue life (Nf) of model and corrosion fatigue life (Nf) obtained by experimental work 112 xvi LIST OF TABLES TABLE TITLE PAGE 2.1 Physical properties of unalloyed titanium 9 3.1 Chemical composition of CpTi 41 3.2 Mechanical properties of CpTi 41 3.3 Experimental design of nitrogen ion implantation process 42 3.4 Simulated body fluid solution reagent 48 3.5 Comparison of mpy unit with equivalent metric-rate expressions 51 3.6 Experimental design for fatigue and corrosion fatigue test 54 4.1 Width and peak of intensity XRD pattern for CpTi, TiN and Ti2N 4.2 72 The projected range (Ri) and longitudinal straggle Ri at different energies 74 4.3 Comparison of different method of hardness test 74 4.4 Micro-hardness distribution at different energies and doses 75 4.5 Corrosion behaviour of Nii-Ti in 3.5% NaCl 81 4.6 Corrosion behaviour of Nii-Ti in SBF solution 85 4.7 Material properties of CpTi and Nii-Ti 90 4.8 Fatigue life and corrosion fatigue life of CpTi and Nii-Ti in the averaged number of cycles 95 4.9 The electrochemical properties of corrosion fatigue 103 4.10 Critical size of initiation crack 109 xvii LIST OF SYMBOLS AND ABBREVIATIONS A - Area ASTM - American Society for Testing and Materials Al - Aluminium Al2O3 - Aluminium Oxide/ Alumina At% - Atomic Percentage a.u. - Auxiliary unit BATAN - Badan Tenaga Nuklir Nasional (National Nuclear Energy Agency of Indonesia) bcc - Body centred cubic cm - Centimetre C - Paris’s material constant CE - Counter Electrode CpTi - Commercially pure titanium , - Fatigue crack growth rate EW - Equivalent weight Ecorr - Corrosion potential f - Frequency F - Corrosion degradation factor fcc - Face-centred cubic h - Hour Hz - Hertz HF - Hydrofluoric acid HNO3 - Nitric acid H2O - Water Icorr - Total anodic current xviii icorr - Corrosion current density K - Stress Intensity Factor k - Strength coefficient Kc - Critical stress intensity factor KIC - Fracture toughness Kpc - Stress intensity factor at instance of crack initiation Kt - Stress concentration factor keV - Kilo electro Volt K - Stress intensity factor range ΔΚth - Fatigue threshold stress intensity factor range l - Liter m - Paris’s material constant mV/s - Milivolt per second mg - Miligram mm - Milimetre MPa - Mega Pascal mpy - Mil per year mV - Milivolt n - Number of element N - Number of cycle 2Nf - Reversals to failure nA - nanoampere NaCl - Sodium chloride N2 - Nitrogen Nii-Ti - Nitrogen ion implanted Cp Ti O2 - Oxygen / Air R - Stress ratio, ( RE - Reference Electrode Sa - Stress amplitude Scf - Fatigue strength in corrosive medium Sf - Fatigue strength in laboratory air Sm - Mean stress S’f - Fatigue strength coefficient xix SBF - SEM/EDS Simulated Body Fluid Scanning Electron Microscopy/Energy Dispersion Spectroscopic - Stress range ( Ti - Titanium TiO2 - Titanium Dioxide TixN - Titanium Nitride WE - Working Electrode - Plastic strain - Elastic strain - Epsilon - Fatigue strength κ - Kappa ϴ - Theta α - Alpha ρ - Rho (density) γ - Gamma - Chi μA - Microampere μm - Micrometer W - Atomic weight of the element XRD - X Ray Diffraction - Geometry correction factor ɛ ) xx LIST OF APPENDICES APPENDIX TITLE PAGE A Quality Certificate Sample 129 B Calculation of Wear Resistance 130 C Phase Diagram of Titanium (Ti) – Nitrogen (N) 133 D X-ray Diffraction Patterns of CpTi and TiN 134 E Calculation of Material Behaviour 140 F Calculation of Material Exponents 149 G Prediction of Corrosion Fatigue Life 151 H Certificate of Nitrogen Ion Implantation 152 I Nitrogen Ion Implantation of Fatigue Specimens 153 J List of Publications 154 CHAPTER 1 INTRODUCTION This chapter begins with the background of the research and important elaboration, followed by problem statements, objective, scope, contributions of the research and organization of the thesis. 1.1 Background of research Metallic biomaterials are the most appropriate implant materials to replace failed hard tissue at present. Stainless steels, cobalt based alloys, titanium and its alloys are the three most used metals for biomaterials in fabrication of medical devices. Recently, titanium and titanium alloys are getting much more attention as biomaterials because they have high specific strength, low density, good resistance to corrosion, moderate elastic module of 100-110 GPa (Leyens & Peters, 2003; Majumda et al., 2008), no allergic problems and good biocompatibility (non-toxic and not rejected by the human body) among other metallic biomaterials. They exhibit a high corrosion resistance due to the formation of a stable passive layer (TiO2) on its surface. Therefore, they have been extensively used in the last several decades as materials for dental implants, and medical devices. Nowadays, they are also considered by medical engineering as the material of choice for medical application (Elias et al., 2008; Niinomi, 1998; Van Noort, 1987), i.e. the prosthetics, internal fixation, inner body devices and instrumentation. Since significant benefit of titanium for patients, surgeons and engineers, the use of the titanium would steadily increase in the near future. Besides the increasing 2 of titanium used as implant materials are due to the increase in the olders generation or aging population worldwide, the trend toward more active lifestyles, and the ability to control health care cost. The population ratio of the aged people has grown rapidly, so the number of the elder demanding and replacing failed tissue with artificial devices from biomaterials is also increasing, particularly, the amount of usage of instruments for replacing failed hard tissues such as artificial hip joints, and dental implants. Pure titanium and Ti–6Al–4V are still the most widely used among the titanium alloys where they meet a demand almost the market of titanium biomaterials. Basically, they are developed as structural materials particularly for aerospace structures (Niinomi, 2003; Luetjering & Williams, 2003). Therefore, the development of titanium targeted for biomedical applications are highly required. Accordingly, the research and development on titanium composed of non-toxic elements were started (Silvaa et al., 2004), and are under development which increase continuously. Although commercially pure titanium (CpTi) exhibit several advantages as biomaterial, but its resistance to wear is lower than Ti alloy. It is therefore necessary of surface treatment of commercially pure Titanium (CpTi) to enhance the resistance to wear by ensuring no decline in corrosion resistance. Some surface processing, such as sandblasting, induces rough and contaminated surfaces and it might be an increasing in risk to failure due to this surface condition results in higher corrosion susceptibility. Electrochemical investigations of the corrosion behaviour of CpTi and Ti alloys have always demonstrated very good passivity condition of the surface. However, the study about ensuring reliability of medical implant is still insufficient. Therefore, the prediction of the corrosion fatigue life of pure titanium with nitrogen ion implanted surface as the implant material would be a valuable contribution on ensuring the sustainability of the implant devices. 1.2 Problem statements Nitrogen ion implantation was introduced onto CpTi to modify the surface condition for more reliable performance and to increase its surface resistance to wear and corrosion. However, the problem with ion implantation is crystallographic damage, 3 produces implantation damage on the surface (Rautray et al., 2011) and point defect in target crystal on impact resulting imperfection in lattice crystal such as vacancies and interstitials known as point defects. Ion implantation introduces both a chemical change in the target surface and a structure change in the crystal structure that could be surface defect in the form of a void or micro crack those can cause premature failure of the implanted device. Several research works studied on corrosion behaviour of CpTi and Titanium alloys (Fukumoto et al., 1999; Sundararajan, & Praunseis, 2004; Raman et al., 2005), however more work are necessary in the area of fatigue as well as corrosion fatigue for the nitrogen ion implanted CpTi (Vardiman & Kant, 1982). This study focuses more comprehensive on the analysis of corrosion fatigue for commercially pure titanium using nitrogen ion implantation. The nitrogen ion implantation might create surface damage and lattice disorder in the near surface of the material. Therefore, the nitrogen ion implanted CpTi, with surface damage, when it is applied a cyclic stress in body fluid or saline solution environment could be the potential factors caused the corrosion fatigue failure for the proposed biomedical material. Intensive research is needed to prove the fatigue behaviour of CpTi after implantation with nitrogen ion. 1.3 Objective The objective of this research is to analyze corrosion fatigue behaviours for commercially pure Titanium using nitrogen ion implantation. A series of studies was conducted to achieve specific objectives as follows: 1. To obtain the optimum parameter of CpTi after nitrogen ion implantation. 2. To investigate the influence of the nitrogen ions implantation on fatigue and corrosion fatigue properties. 3. To develop an empirical model based on experimental data for corrosion fatigue life prediction. 1.4 Scope of research The scopes of this research are as follow: 4 1. Introducing the nitrogen ion onto surface of CpTi by ion implantation method to modify the surface hardness that can improve the wear and corrosion resistance. Beam energy of 80, 100 and 115 keV and dose of 0.5x1017, 1.0x1017 and 2.0x1017 ions/cm2 are used as the variables proposed for nitrogen ion implantation process. 2. Specimens that had been implanted with nitrogen ion were analyzed for the formation of nitride phase. Surface hardness and corrosion rate of the Nii-Ti specimens were tested to verify the optimal parameter of implantation process. In addition, the tensile and wear resistance tests were also to be carried out on the nitrogen ion implantation specimens. 3. The nitrogen ion implanted specimens were tested the fatigue in laboratory air and in saline solution with the frequency of 10 or 20 Hertz and stress ratio, R, of -1. 4. Based on the experimental results, the empirical model was developed for estimation of corrosion fatigue life for CpTi using nitrogen ion implantation. 1.5 Contributions of research Corresponding to the above objective, some important points could be expressed as contribution to the knowledge and professional usage as well as industrial application. There are three prominent contributions that can be provided from the result of this research. 1. Improvements in corrosion resistance and mechanical properties for Ti used biomedical applications have practical importance. Different energies at different doses for implanting nitrogen ion are a good approach. 2. The use of nitrogen ion implantation is a good technique for the improvement of fatigue strength of Ti base materials. 3. The penetration growth law for Nii-Ti was established for contribution to the service life estimation of Ti base materials in acidic environments. 1.6 Thesis organization The present thesis comprised of five chapters that were organized in order to address the objectives referred to in section 1.3 which are: 5 • Chapter 1: The description of research overview was discussed and the investigations performed in this area was briefly reviewed. The knowledge gap for significant corrosion behaviour and mechanical properties of CpTi with surface modification is extracted from the state-of-art to define the research objectives. The problem statements, research objective, scope of the research and the research contributions are described. The overall contents of the thesis are also summarized in this chapter. • Chapter 2: The basic theory to support the implementation of the whole research is discussed in this chapter. • Chapter 3: The details of the experimental investigations are presented. The properties of the CpTi, the fabrication process and equipment used in the research activities are described. The loading set-up, experimental conditions and measuring systems employed to collect the experimental data are explained. • Chapter 4: The achieved results of the research are presented and discussed following the objective of the research. The most important findings are also described. • Chapter 5: The conclusions derived from experimental and theoretical investigations are presented. The future works as recomendations are also stated in this chapter. 6 CHAPTER 2 LITERATURE REVIEW The current research on the effect associated with nitrogen ion implanted commercially pure titanium (Nii-Ti) in body fluid environment are important to understand and keep up to date as it changes with the latest technology and materials. Establishing a framework for the present study, the basic concept involved in surface modification, corrosion and corrosion-fatigue are reviewed. Later, specific examples are outlined to show basic trends found in the literature. Finally, empirical model of fatigue-life time prediction was briefly described. 2.1 Titanium in biomedical applications Titanium is found in the earth‟s crust at the level of about 0.63% by mass and it is the seventh-most abundant element metal (73.8%) (Barksdale, 1968; Barbalace, 2006). It is recovered from TiO2 which is rich with deposits of rutile and ilmenite, FeTiO3, that are found on every continent (Luetjering & Williams, 2003). Since its discovery in 1791, and up until Kroll‟s innovative process development in 1932, there had been no practical methods to recover titanium metal from these ores because of its prominent affinity for oxygen. Since the modern ore extraction, beneficiation and chemical processes are discovered, then it is enabled the large-volume manufacturing of high-grade TiO2. This compound became an important pigment for paints and commercial products, and of titanium metal for the production of the CpTi grades, titanium-based alloys and other alloys systems. The Dupont Company was the first to produce titanium commercially in 1948. Today, the primary consumer of titanium is 7 the aerospace field, whereas the other market such as medicine, automotive are gaining increased acceptance (Leyens & Peters, 2003). Commercially pure titanium is unalloyed titanium. At service temperatures it consists of 100% -hcp phase. As a single-phase material, its properties are controlled by chemical elements (iron, oxygen and interstitial impurity elements) and grain size. It is classified into Grades 1 through 4 depending on strength and allowable levels of the chemical elements i.e. iron, carbon, nitrogen, and oxygen. CpTi ASTM Grade 2 has the yield strength of 275 MPa. (Luetjering & Williams, 2003 and Niinomi, 1998). In the galvanic series of metals, titanium has a standard reduction potential of -1.63 Volts which is close to aluminum of -1.662 Volts. Therefore, titanium is very active in Electro-motif force (Emf) series about 1.2 V more active than iron with standard electro potential of -0.44 (Winston & Uhlig, 2008). The excellent resistance of titanium to general corrosion in most environments is well-known. This is the result of stable protective surface film, which basically consists of TiO2. This thin oxide film makes the titanium passive as long as the integrity of film is continuously formed and maintained, generally caused by which most oxidizing environment. On the other hand, titanium is not corrosion resistant under reducing condition, where the protective nature of oxide film breaks down such as in sulfuric, hydrochloric and phosphoric acid is not good (Luetjering & Williams, 2003). Titanium (Ti) and its alloy have been widely used for medical implants or fixtures, owing to their superior specific strength, corrosion resistance, and biocompatibility. The use of such materials can be proposed in response to a need for artificial hard tissue, because they have characteristics that are advantageous to biomedical engineering purposes (Balazic et al., 2007; Jagielski et al., 2006; Liu et al., 2004; Fukumoto et al., 2000; Niinomi, 1998). Figure 2.1(a)-(c) show examples on usage of Titanium for artificial hip joint bone plate implant and hip replacement, respectively. 8 (a) (b) Figure 2.1 Examples of titanium application: (a) artificial hip joint (Liu et.al. 2004), (b) bone plate implant and (c) hip replacement (source: http://www.supraalloys.com/medical-titanium.php) The material properties of Ti and its alloy have been proven to be well accepted by human tissues, compared to other metallic biomaterials (Liu et al., 2004; Jagielski et al., 2006). Table 2.1 shows the physical properties of unalloyed titanium (Liu et al., 2004). The unalloyed titanium presented in Table 2.1 is classified as high grade titanium. Its ultimate strength and yield strength are almost equal to the titanium alloys with ultimate strength of 860-965 MPa (Sun et al., 2001; Geetha et al., 2009). The performance of biomedical implants relies on the biocompatibility, corrosion behaviour, mechanical properties, formability, and availability of the materials (Liu et al., 2004; Balazic et al., 2007). CpTi is now widely used for hard 9 tissue replacement due to the fact that its properties are suited for the needs of medical applications, except wear resistance when used for artificial hip joints. Table 2.1 Physical properties of unalloyed titanium (Liu et al., 2004) Properties Atomic number Number of electrons Atomic weight (g/mol) Equivalent Weight (EW) Crystal structure Alpha, hexagonal closely packed (hcp) c(Ǻ) a(Ǻ) Beta, body centered cubic (bcc) a(Ǻ) Density (g/cm3) Coefficient of thermal expansion, α, at 20°C (K-1) Thermal conductivity (W/(mK)) Melting temperature (°C) Boiling temperature (estimated) (°C) Transformation temperature (°C) Electrical resistivity High purity (μΩCm) Commercial purity (μΩCm) Values 22 2 47.90 23.95 4.6832±0.0004 2.9504±0.0004 3.28±0.003 4.54 8.4×10-6 19.2 1668 3260 882.5 42 55 The nature of CpTi is its inherent corrosion resistance, which is attributed to the spontaneous formation of a strong passivation oxide layer. The extent of this corrosion resistance dictates its biocompatibility and is suitable to be used in a physiological saline solution (Pompe et al., 2004). The nature of CpTi is also sufficient elasticity, which has become necessary for apt design of hip joint replacements; elasticity is a decisive factor for hard tissue replacement. The characteristics of Ti and its alloy are characterized by the inert nature within the human body: immune from the attack of bodily fluids, compatible with bone growth, strong, and flexible. 2.2 Mechanical loading imposed on an implant device in human body An implant is often subjected to cyclic loading during daily activity of the human body. It can also be chemically attacked by the body fluid medium, under certain conditions. Among the mechanical and chemical parameters that can influence the 10 corrosion-fatigue behaviour of such material, cyclic stress's parameter in body fluid (saline solution) is need to be highlighted and verified its effect on stress cycles before the final failure of implant devices. Another factor that also assists the fatigue failure is crack length of material implant. Therefore, fatigue and other mechanical properties such as toughness and wear resistant of biomaterial structure in a living environment need to be evaluated and improved in order to confidently use the implants for a long period of time. The complexity of the service conditions and loads encountered on devices implanted in the human body is generally quite high. Depending on the activities of the patient, implanted device experiences of both static loading in the form of body weight and also dynamic in the form of cyclic stress during walking or running. These stresses are actually far under fatigue limit of the material implanted, however, the implanted device can fail before its life time due to the mechanical and chemical loading of implanted device. Figure 2.2 shows a schematic picture of the crosssection of a deformed metallic biomaterial surface, surrounded in a physiological environment (Teoh, 2000). The Figure 2.2 illustrates three distinguishable layers, namely (1) the molecular absorbed layer, (2) the passive oxide film, and (3) the deformed layer. The molecular absorbed layer is an aqueous sandwich layer of biological components to establish a good bond between the host tissue and the biomaterial. The passive oxide film is protective passive film consist of either metal oxides or hydroxides and act as a burrier protecting the metal surface from the corrosive environment (Kim, J. J. & Young, Y. M., 2013), and deformed layer is surface and subsurface damage arising from a spherical indentor. The implant device is introduced into a patient must have sufficient strength to sustain and transmit the load actions resulting from joint and muscular forces. The actual stress working on the material implant in human body depends on the body weight where a value of 2.5 BW (Body Weight) seems to be reasonable in hip implants design. Peak forces are considered to be equal to 2.5 BW. While for loading frequency is taken 0.5 Hz with an assumption that we could walk 2 h per day with a pace of one step per second. (Cicero et al., 2007). 11 Physiological environment Cells Damage zone Cyclic stress Contact body Molecular absorbed Layers Passive oxide layer Deformed layer Intrinsic microstruture Figure 2.2 Schematic illustration of a cross-section of a deformed metallic biomaterial surface showing the complex interactions between the material‟s surface and the physiologic environment (Teoh, 2000) Another researcher (Mudali et.al. 2003) argued that mechanical forces imposed on the implant as follows: (1) the load varies with the position in the walking cycle and reaches a peak of about four times of body weight at hip and three times the body weight at the knee. The frequency of loading and load cycles encountered over a specific time period are also important. A past rate of walking corresponds to one to two million steps per year. For an active person, the number of steps taken may be two or three times more taken by a normal person (2) the human body is a harsh environment for metals and alloys having to be in an oxygenated saline solution with salt content of about 0.9%, at pH 7.4 and temperature of 37+/-1 (Mudali et al., 2003) 2.3 Ion implantation technique for surface modification Surface modification is a technique used to change the physical, chemical, electrical or mechanical properties of metallic material surface such as wear resistant, corrosion behaviour, fatigue properties and of enhancement of biocompatibility particularly subjected to medical application. Several established methods of surface modification are employed: shot peening, plasma nitriding, plasma immersion ion implantation (PIII), magnetoelectopolishing, chemical etching, anodizing, ion implantation etc. Ion implantation technique will be discussed in detail in this section. 12 2.3.1 Review of ion implantation technique Ion Implantation is a potential enhancement method for modifying the surface properties of materials by insertion of accelerated atoms, within the first atomic layers of the component using a high technology approach. It is similar to a coating process, but it does not involve the addition of a layer on the surface. Originally, this technique was developed to produce controlled doping of semiconductors, and still used extensively in that capacity today and now it had being used to modify or change the material‟s near-surface chemical composition or defect state. Consequently, there can be a distinct modifications to the near-surface microstructure and chemical, physical and mechanical properties which for example can appear as changes in corrosion behaviour, electronic properties, stiffness, hardness, wear resistance, friction response (Al Jabbari et al., 2012), or other surface-regionsensitive mechanical properties such as fatigue and contact fracture toughness (Tanaka et al., 1996; Nastasi & Mayer, 2006). Using highly energetic beams of ions (positively charged atoms), this technique is used to modify surface structure and chemistry of materials at low temperature. The moderate heating associated with the process virtually eliminates any risks of distortion or oxidation effects and mostly the operating process is between 150oC and 200oC which depend on the level of the ion beam flux (Woolley, 1997). The process does not adversely affect component dimensions or bulk material properties. It has been used extensively and successfully for studying the mechanism under-laying the so called reactive element effect. In general it is found that influence of the implanted element is applied as a coating or present as an alloy or oxide dispersed addition. on implantation is also a powerful method for modifying the near surface properties of material. To cater for diverse research and application, the implanting facilities must be flexible. For example, ion beams of elements are desirable, dose can cover the range from 109 ions cm-2 to 1018 ions cm-2, In ion implantation, high energy ions are generated in an ion accelerator and implanted into the alloy surface. The penetration depths are typically in the order of 1-100 nm while the concentration distribution has a maximum value of up to several tens of percent (Stroosnijder, 1998; Nastasi & Mayer, 2006). In addition, more recent investigations have reported that ion implantation had improved fatigue and corrosion resistance in metallic 13 alloys, polymers and ceramics. Currently, the technique is most commonly employed to treat the surface of cutting and machining tools, moulds, casting dies, alloys for nuclear reactors containers, food packaging materials, medical implants, biocompatible materials, etc (Agarwal & Sahoo, 2000). Figure 2.3 and Figure 2.4 show schematic of an ion implantation system and ion implantation process, respectively. Figure 2.3 Schematic of an ion implantation system (Nastasi & Mayer, 2006) Figure 2.4 Schematic of the ion implantation process (Denison et al., 2004) Improvement of the surface hardness as well as corrosion resistance that yielded by ion implantation technique is influenced by the implantation parameters involve 14 energy, dose or time. The two key parameters defining the final-implantation profile are dose D (in ions/cm2) and energy, E, (in kilo electro Volt, keV). The dose is related to the beam current, I, expressed by the following formula (Equation 2.1): (Spitzlsperger, 2003; Nastasi & Mayer, 2006; Wen & Lo, 2007). D(dose) I (nA)t ( s) 1.6 x10 19 qA(cm 2 ) (2.1) where D denotes implantation dose, I represent the beam current (nA), t is beam time (s), q is charge state of the ion, and A is defined as the striking area (cm2). A significant advantage of ion implantation is that the treated surface is an integral part of the work piece and does not suffer from possible adhesion problems associated with coatings. The moderate heating associated with the process virtually eliminates any risks of distortion or oxidation effects. The process does not adversely affect component dimensions or bulk material properties. Ion implantation produces no dimensional changes in the work piece (Woolley, 1997). Figure 2.5 illustrates the path of an individual ion in ion implantation process. Modified region Figure 2.5 Schematic view of the path of an individual ion in process of ion implantation (Hirvonen & Sartwell, 1994). 15 2.3.2 Theoretical prediction of penetration depth The penetration depth of the implanted ions depends on the ion weight or mass, energy and on material substrate (Hunsperger, 2009). As the ions penetrate into substrate of the specimen, they lose their energy due to the interaction with the electrons and the atoms of the specimen. Their energy continuously decreases when the ion is traveling deeper into the substrate. The energies of ion implantation range from several hundred to several million kilo electrons volt (keV), yielding in ion distributions with average depths from < 10 nm to 10 µm. Doses range from 1011 ions/cm2 for threshold adjustment to 1018 ions/cm2 for buried dielectric formation. Theoretical calculation was made using the simulation program Transport of ions in matter (TRIM)-Stopping and Range of Ions in Matter (SRIM) simulation software providing an approach of the penetration depth penetration. SRIM is a computer program used to calculate interaction of ions with matter and the core of SRIM is a program Transport of ions in matter (TRIM). This open source computer programs were developed by Ziegler et al., 1985 and are being continuously upgraded with the major changes occurring approximately every five years. SRIM is based on a Monte Carlo simulation method, namely the binary collision approximation with a random selection of the impact parameter of the next colliding ion. It needs the ion type and energy (in the range 10 keV - 2 GeV) and the material of one or several target layers as the input parameters. The predictions of the implantation depth in the near surface of specimens were provided from that software, and calculated the depth of implanted ions using following equation: 𝑥𝑖 = 𝑅𝑖 + 𝛿𝑅𝑖 (2.2) where, 𝑥𝑖 is penetration depth of implanted ions, Ri is ion range and 𝜹Ri is the longitudinal straggling (Nastasi & Mayer, 2006; Saryanto et al., 2009; Suzuki, 2010). 2.3.3 Surface modification of CpTi by nitrogen ion implantation Surface modification methods such as anodic oxidation treatment, (Song et al., 2007) sandblasting, (Jiang et al., 2006) carbide coating, (Velten et al., 2002) plasma 16 nitriding, (Kapczinski et al., 2003) electrochemical treatment (Guilherme, 2005) and nitrogen ion implantation (Jagielski et al., 2006; Fukumoto et al., 2000; Shikha et al., 2008; Arenas et al., 2000) have been proposed to increase corrosion-resistant and wear-resistant of material. CpTi with modified surface has good mechanical and chemical properties as well as biocompatibility in human body environment. The most common ion used for application in metallurgical surface treatment is nitrogen. When the nitrogen ions penetrate and diffuse the surface of the specimen, some of them wedge micro cracks, some occupy lattice spaces in crystalline structures, and some form compounds through the chemical reaction (i.e.; titanium nitride: TiN; Ti2N), resulting a new lattice properties as inherent of face center cubic (fcc) and tretragonal space lattice. It has been established that nitrogen implantation into metals can alter their surface properties such as hardness, friction, wear and corrosion resistant, etc. Among the treatment options, as mentioned previously, the nitrogen ion implantation technique is a good method to enhance passivity and to reduce the corrosion rate. This is due to the fact that the formation of TiN and Ti2N phases elude the migration of ions and stabilize the TiO2 film growth on the surface of titanium (Arenas et al., 2000; Mudali et al., 2003). Nitrogen ion implantation can modify the Ti surface to produce wear-resistant species such as nitrides (TiN; Ti2N) other than TiO2 from the surface. The surface of nitrogen ions implanted Cp Ti appeared to consist of a mixture of TiO2 and TiN/Ti2N or a Ti oxynitride as shown in Figure 2.6 (Liu et al., 2004). Figure 2.6 illustrates the cross-sectional view of thin film and surface-modified layer formation for surface modification of titanium by ion implantation technique. Surface modification had been performed at specific energies to assess the formation of the nitride phase, surface hardness, wear resistance, and corrosion behaviour in various doses (Sundararajan, & Praunseis, 2004; Arenas et al., 2000; Fukumoto et al., 1999). Still, the mechanical properties, chemical composition, and corrosion resistance for CpTi surface implanted nitrogen ions in various doses and energy need to be verified for achieving good result from combining parameter between energy and dose as optimal parameter of the ion implantation process. 17 Figure 2.6 Cross-sectional illustrations of thin film and surface-modified layer formation (Liu et al., 2004) 2.4 Corrosion effects associated with biological environment A multidisciplinary approach is necessary in studying corrosion-fatigue that involves chemistry, electrochemistry, mechanics and metallurgy. In this section, the chemistry, electrochemistry and mechanics that cause corrosion related failures are described. First, it reviewed the various forms of corrosion that lead to failure in pure titanium related with chemistry or electrochemistry that caused them. Then, the mechanisms responsible for the effects of corrosion fatigue are discussed. 2.4.1 Corrosion forms of pure titanium Pourbaix (1966; 1974) demonstrated that a metal could react in one of four ways when exposed to a corrosive solution. He proposed the diagrams which are called Pourbaix Diagram by varying the electrode potential and pH of the solution. The diagrams demonstrate the corrosion activity that is thermodynamically favored in a given system. A Pourbaix diagram for titanium in water at 25oC is shown in Figure 2.7. The diagram shows conditions of corrosion, immunity and passivation of titanium in dependency of oxidizing potential and pH. The diagram consists of four areas that represent the ways that a metal can react to a corrosive solution. He demonstrated that a metal could be immune (passive TiH2 region) from chemical reaction (passive TiH2 region), shown active corrosion (Ti+2region) displayed passivity due to formation of a protective oxide film (Ti02 18 region), or suffered from pitting corrosion due to localize breakdown of a passive film. If the protective oxide film breaks down locally, then the surface metal is exposed to the solution and released its ion forming the pit. Figure 2.7 Theoretical conditions of corrosion, immunity and passivation of titanium (Pourbaix (1966; 1974) The above diagram shows the significant differences in corrosion behaviour resulting from different properties of TiO2 film. This film is very chemically resistant and is attacked by very few substances. The following reactions are the basic corrosion of Titanium in aqueous environment (Equation 2.3 – 2.4): Ti Ti 2 2e E o 1.63V (2.3) 2 H 2e H 2 and H 2O O2 4e 4OH (2.4) 19 The basic reaction of Titanium in water is (Equation 2.5 – 2.6): Ti 2 H Ti 2 H 2 (2.5) Ti 4 H 2 O Ti (OH ) 4 2 H 2 (2.6) Ti (OH ) 4 is a passive film of Titanium by a direct electrochemical reaction. Balakrishnan et al., (2008) observed the formation of passive film on titanium surface in SBF solution with the presence of Ca, P, Ti and O elements. The surface passive TiO2 layer reacts with SBF solution which can be illustrated in Equations 2.7 – 2.11 as follows (Liu et al., 2004): TiO 2 OH HTiO 3 (2.7) Ti 3OH Ti (OH ) 4e (2.8) Ti (OH ) 3 e TiO2 .H 2O 1 / 2 H 2 (2.9) Ti (OH )3 OH Ti (OH ) 4 (2.10) TiO2 .nH 2O OH HTiO 3 .nH 2O (2.11) The Ti–OH groups formed on the surface from the above reaction are negatively charged and have a chemical affinity for Ca2+ and Na+ ions in the Simulated Body Fluid (SBF) solution. 2.4.2 Effect of nitrogen ion implantation on corrosion resistance of titanium Besides the design of the joint replacement, material selection plays an important role. Materials for human body implants must be biocompatible, corrosion resistant, and strong and have sufficient elasticity (Pompe et al., 2004). Because it is absolutely inert in the human body, immune to attack from bodily fluids, compatible with bone growth and strong, and flexible, titanium is most biocompatible of all metallic implant, i.e. Stainless Steel 316L, cobalt alloys (Nasab & Hassan, 2010; Niinomi, 2008) . Biocompatibility and corrosion resistance of the Ti metal are the result of passive TiO2 film of 2 to 6 nm thickness formed on the surface of Ti (Balakrisnan et.al., 2008; Tamilselvi & Rajendra, 2006; Raman et al., 2005; Dearnley et al., 2004; Arenas et al., 2000). The corrosion behaviour of Ti and its 20 alloys has been studied using certain types of biological media (Tamilselvi & Rajendra, 2006; Raman et al., 2005; Dearnley et al., 2004). The implantation of nitrogen ion can enhance the passivability and reduce the corrosion kinetics of the alloy surface with increasing tendency for repassivation and with a significant decrease in ion release rates (Gordin et.al., 2013), and thus can enhance corrosion resistance. This improvement arises from the formation of precipitates of TiN and Ti2N, which screen underlying titanium atoms, avoiding their migration and stabilizing the growth of the oxide film (Arenas et al., 2000). Introducing to commercially pure titanium, Nitrogen-ion implantation showed an improvement in the electrochemical behaviour of the passive film. Doses between 4x1016 and 7x1016 ion/cm2 is recommended for orthopedic applications. A detrimental effect is shown by implantation with higher doses due to the formation of nitride phases (Sundararajan & Praunseis, 2004; Kapczinski et al., 2003) that can accumulate surface damage, thus leading to increasing the corrosion resistance and nanohardness (Shikha et al., 2008). 2.5 Fatigue and corrosion fatigue of metals Fatigue is a process of progressive localized permanent structure change occurring in a material subjected to condition that produce fluctuating stress and strain at point that may culminate in crack or complete fracture after a sufficient number of fluctuations. The load histories for a real components, structures and vehicle are quite diverse, at one extreme, they may be rather simple and repetitive, at the other extreme, may be completely random. The constant amplitude loading is used to obtain material fatigue behaviours/properties for used in fatigue design. Figure 2.8 illustrates schematically the basic fatigue loading for constant amplitude loading pattern. The load ration (R-ratio) is defined as the ratio of minimum to maximum stress amplitude as shown in Equation 2.12. 𝑅 = 𝑆𝑎 𝑚𝑖𝑛 /𝑆𝑎 𝑚𝑎𝑥 (2.12) Where: 𝑆𝑎 , 𝑆𝑚 𝑎𝑛𝑑 ∆𝑆 (𝑆𝑚𝑎𝑥 − 𝑆𝑚𝑖𝑛 ) denote stress amplitude, mean load and stress range respectively and f denote the frequency of the cycle stress. The R-ratio value of fully reversals is -1 (R=-1) which means that the mean stress, 𝑆𝑚 = 0 and 𝑆𝑎 = -𝑆𝑎 . 21 +𝑆𝑎 𝑁 −𝑆𝑎 Cycle (2 reversals) 𝑅= 𝑆𝑎 −𝑆𝑎 𝑆𝑚 = 0 =−1→Fully reversed Figure 2.8 Schematic illustration of cyclic loading parameters Most mechanical components and structures made of metal and alloy are subjected to cyclic loading. Some those machine components such as super-heaters, propeller shafts, turbines and pump elements, drilling equipment in petroleum industry severely suffer from corrosion fatigue problem. Once cyclic loading occur in inert environment, the structures or components suffer to fatigue failure. However, when the components and structures subjected to cyclic loading and corrosive environment even fresh water or atmospheric air, the Corrosion Fatigue “C-F” can occur (Ebara, 2007; Genel et al., 2000; Murtaza & Akid, 1996). The first study of metal fatigue is believed to occur around 1829 by German mining engineer Albert. The detailed research effort into metal fatigue was initiated in 1842 following the railway accident in France. The cause of this accident was traced to fatigue failure. A systematic investigation of fatigue failure was conducted by Wöhler, during the period 1852-1869 in Berlin. His work led to characterization of fatigue in term of Stress-life (S-N) curves and to the concept of fatigue „endurance limit‟. Another well known fatigue researcher of this era was Fairbairn, (1864), Geber, (1872), Goodman (1899), Ewing & Rosenhain (1900), Ewing and Humfrey (1903). The development of metal fatigue research came in new era was begun by Griffith (1921) and Paris et al., (1961). They applied the fracture mechanic concept to solve fatigue problem of notch specimen. Later it will be described some detail concepts of development in fatigue as well in corrosion fatigue. In order to understand the fatigue mechanism, it is important to consider various technical conditions that influence fatigue life and fatigue crack growth. There are three technical conditions involved (a) material surface quality, (b) residual 22 stress and (c) environment effect. This understanding is necessary to analyze fatigue properties of engineering structure in term of fatigue as a crack initiation process (crack initiation period) followed by a crack growth period as shown in Figure 2.9. Figure 2.9 Schematic description of total fatigue life and its relevant factors (Schijve, 2009) Corrosion fatigue is the metal cracking caused by combined action of a cyclic loading and a corrosive environment. The severity of the action depends on the range and frequency of the stress, the nature of the corroding condition and the time under stress (Murtaza & Akid, 1996; Sivaprasad et al., 2006). So, corrosion fatigue is influenced by various mechanical, chemical and structural parameters that interact locally. Corrosion fatigue is similar to stress corrosion cracking in many aspects. The principal difference between these two types of environment enhanced cracking is in the character of loading, which is static in stress corrosion cracking and repeated loading in corrosion fatigue. Both fatigue life and fatigue limit are reduced in the presence of corrosive environment as compared to the fatigue in neutral environment. These are caused by interaction of electrochemical, metallurgical and mechanical processes at the crack tip (Ramsamooj & Shugar, 2001a). The aim of the above review is to describe some phenomenological observation of corrosion fatigue failure of mechanical components and structures and method of evaluation. In addition, some results proposed by previous researcher in term of stress-life, strain-life and crack initiation and crack growth rate-stress intensity range will be presented. 23 2.5.1 Mechanism of corrosion-fatigue Under cyclic loading conditions, the embrittling environment can accelerate the initiation of a surface flaw in an initially crack-free material and propagate the flaw to certain critical size. Corrosion fatigue is a term which is commonly used to denote the damage and failure of material under the combination action of cyclic stress and any embrittling medium, although most wide spread adaptation is in the context of aqueous environments. The corrosive environment produces corrosion products. Corrosion fatigue is associated with two different mechanisms: Anodic dissolution mechanism of corrosion fatigue and hydrogen assisted corrosion fatigue (Ramsamooj & Shugar, 2001a; Marcus, 2002). The mechanism of anodic dissolution cracks initiate at the surface sites of localized concentration of tensile strength. A crack progresses along a specific path which is composed of specific crystal planes within the grains. The mechanism of anodic dissolution is mainly referred to as corrosion fatigue of carbon steels and Stainless steels (Makhlouf et al., 2003) in water and also corrosion fatigue of Aluminum alloys (Chlistovsky et al., 2007) and Titanium alloys in aqueous chloride solutions. Genel et al., (2000) reported that cathodic polarization suppressed the metal dissolution and pit formation, resulting in a noticeable increase in corrosion fatigue strength up to 2.6 times that of free corrosion fatigue. In contrast to anodic dissolution mechanism, hydrogen assisted corrosion fatigue is enhanced by cathodic reaction: 2H+ + 2e- = H2 occurring on the crack tip surface. The atomic hydrogen dissolves in the metal where its ions interact with the dislocations of the crystal lattice causing decrease of the metal ductility (Suresh, 1998). 2.5.2 Stress -life approach in corrosion fatigue Corrosion fatigue in aqueous media is an electrochemical behaviour. Cracks are initiated either by pitting or at persistent slip bands “PSB” (Xie et al., 2002). Corrosion fatigue can hence be reduced by alloy additions, inhibition, and cathodic protection all of which reduce pitting (Congleton & Craig, 1982). Since corrosion fatigue cracks initiate at the metal surface, surface treatments like plating, cladding, nitriding (Genel et al., 2000) and shot-peening or sandblasting (Jiang et al., 2006) were found to improve the materials' resistance to this phenomenon. 24 The important concept of stress-life was proposed by Wöhler. The method characterizes the total fatigue life in terms of nominal stress amplitude and cyclic number (S-N) curve (Stephens et al., 2001). The total fatigue is defined as accumulation crack initiation, short crack, long crack and critical fracture or final failure (Kaynak et al., 1996; De-Guang et al., 1998). The fatigue life equation is written as follows (Equation 2.13): S a log N f (2.13) where Sa is stress amplitude, α and β are constants and Nf is number of cycle. Basquin modified Wöhler‟s formula in term of correlation log-log scale, a linear and power law relationship are commonly observed, as shown in Equation 2.14 and Equation 2.15. The stress-life curve characterizes the contribution of crack initiation and crack propagation processes to total fatigue life in nominally smooth specimen. ln S a ln N f (2.14) S a S a S ' f (2 N f ) b 2 (2.15) or where 𝑆𝑎 is stress amplitude, 𝑁𝑓 is number of cycle and α and β are constants, 𝑆′𝑓 is fatigue strength coefficient and 2𝑁𝑓 is reversals to failure and b is fatigue strength exponent (Basquin‟s exponent). A new approach on the study of early stages of corrosion fatigue cracking was proposed by Acun‟a-Gonza‟lez et al., (2008). A visual recurrence analysis applied to the electrochemical current oscillations registered during corrosion fatigue tests allowed us to characterize the electrochemical dynamics on stainless steel samples surface showing clearly the dynamics of localized corrosion, as well as the formation and initial growth of short corrosion fatigue cracks. Experimental study of corrosion fatigue behaviour welded steel structures has found that the fatigue crack propagation in the corrosive medium is influenced strongly by important weld-geometry parameter and accordingly, Paris‟s material constant need to be determine experimentally to evaluate the corrosion fatigue life (Wahab & Sakano, 2001). Ramsamooj & Shugar (2001b) proposed a new model for 117 REFERENCES Acuña-González, N., García-Ochoa, E., & González-Sánchez, J. (2008). Assessment of the dynamics of corrosion fatigue crack initiation applying recurrence plots to the analysis of electrochemical noise data. International Journal of Fatigue 30 (7), pp. 1211-1219. Agarwal, R., & Sahoo, L. (2000). VLSI Technology and Design: Ion Implantation Chapter 5, 1st Edition. Technical Publications Pune, India (Google book ISBN 9788184324069). Agung, I., Syarif, J., Ghazali, M.J. & Sajuri, Z. (2011). Effect of Cu particels precipitation on wear behaviour of Fe-3mass%Cu under dry sliding condition. Key Engineering Materials, 462-463, pp. 1224-1229. Al Jabbari, Y. S., Fehrman, J., Barnes, A. C., Zapf, A. M., Zinelis, S., & Berzins, D. W. (2012). Titanium Nitride and Nitrogen Ion Implanted Coated Dental Materials. Coatings, 2, pp. 160-178. Arenas, M.A., Tate, T.J., Conde, A. & De Damborenea, J. (2000). Corrosion behaviour of nitrogen implanted titanium in simulated body fluid. British Corrosion Journal, 35(3) pp. 1-5. ASTM Standard, ASTM. (2008). Standard practice for corrosion fatigue testing of metallic implant materials. Annual Book of ASTM Standard. ASTM Standard F1801-97, ASTM International. ASTM Standard, ASTM. (2010). Standard practice for conducting force controlled constant amplitude axial fatigue tests of metallic materials. Annual Book of ASTM Standard. ASTM Standard E466-98, ASTM International, pp 471-477. ASTM Standard, ASTM. (2010). Standard practice for verification of constant amplitude dynamic forces in an axial fatigue testing. Annual Book of ASTM Standard, ASTM Standard E468-97, ASTM International. 118 ASTM Standard, ASTM. (2008). Standard test methods for tension testing of metallic materials. Annual Book of ASTM Standard. ASTM E8M-04, ASTM International. ASTM Standard, ASTM. (1999). Standard practice for calculation of corrosion Rates and related information from electrochemical measurements. Annual Book of ASTM Standard. ASTM G102, ASTM International. Bahmanpour, H., Youssef, K. M., Scattergood, R. O., & Koch, C. C. (2011). Mechanical behaviour of bulk nanocrystalline copper alloys produced by high energy ball milling, Journal of Materials Science. doi:10.1007/s10853-0115312-3. Balakrishnan A., Lee, B. C., Kim, T.N., & Panigrahi, B. B. (2008). Corrosion behaviour of ultra fine grained titanium in simulated body fluid for implant Application. Trends in Biomaterials and Artificial Organs, 22(1), pp. 58-64. Balazic, M., Kopacpp, J., Jackson, M. J., & Ahmed, W. (2007). Review: titanium and titanium alloy applications in medicine. International Journal of Nano and Biomaterials, 1(1), pp. 3-34. Bannantine, J.A. Comer, J.J. & Handrock, J.L. (1990). Fundamentals of Metal Fatique Analysis. NJ: Prentice Hall, Englewood Cliffs. Barbalace, K. L. (2006). Periodic Table of Elements: Ti – Titanium. Retrieved 12-26. Barksdale, J. (1968). Titanium. in Clifford A., Hampel (editor). The Encyclopedia of the Chemical Elements, New York: Reinhold Book Corporation. pp. 732– 738. LCCN 68-29938. Brooks, C. L., Prost-Domasky, S. A., Honeycutt, K. T., & Mills, T. B. (2003). Predictive modeling of structure service life. In ASM Handbook Volume 13A, Corrosion, Fundamental, Testing and Protection, pp. 946-958. Carlson, R. L., & Cardomateas, G. A. (1996). An Introduction to Fatigue in Metals and Composites. London: Chaman & Hall. Carpinteri, A. & Paggi, M. (2007). Self-similarity and crack growth instability in the correlation between the Paris‟ constants. Engineering Fracture Mechanics, 74, pp. 1041–1053. Cassar, G., Banfield, S., Avelar-Batista Wilson, J. C., Housden, J., Matthews, A., & Leyland, A. (2012). Impact wear resistance of plasma diffusion treated and duplex treated/PVD-coated Ti-6Al-4V Technology 206, pp. 2645–2654. alloy. Surface and Coating 119 Chlistovsky, R.M, Heffernan, P.J. DuQuesnay, D.I. (2007). Corrosion fatigue behavior of7075-T651 aluminum alloy subjected to periodic overloads, International Journal of Fatigue 29, pp. 1941-1949. Cicero, S., Gutierrez-Solana, F., Allvarez, J. A., & Sanchez, L.(2007). Failure analysis of a hip implant by using the FITNET fitness for service procedure, Engineering Fracture Mechanics 74, pp. 688-702. Congleton, J. & Craig, I.H. (1982) in Corrosion Processes, Parkins, R.N (ed.). Applied Science Publishers, London, pp. 209-269. Dearnley, P. A., Dahm, K. L. & Cimenoglu, H. (2004). The corrosion–wear behaviour of thermally oxidised CP-Ti and Ti–6Al–4V. Wear, 256, pp. 469479. De-Guang, S., Wei-Xing, Y., & De-Jun, W. (1998). A new approach to the determination of fatigue crack initiation size. International Journal of Fatigue, 20 (9), pp. 683-687. Denison, A. B., Hope-Weeks, L. J., Meulenberg, R. W., & Terminello, L. J. (2004). Quantum Dots, in Introduction to Nanoscale Science and Technology. In Di Ventra, M, Evoy, S, and Heflin, J.R (Eds.). Springer Science & Business Media Inc.: pp. 183-198. Ebara, R. (2007). Corrosion fatigue crack initiation in 12 % chromium stainless steel. Materials Science & Engineering A 468-470, pp 109-113. Ebara, R. (2010). Corrosion fatigue crack initiation behaviour of stainless steels. Procedia Engineering 2, pp 1297–1306. El Haddad, M. H., Topper, T. H., & Smith, K. N.(1979). Prediction of non propagation crack. Engineering Fracture Mechanics 11(3), pp. 573-584. Elias, C. N., Lima, J. H. C., Valiev, R., & Meyers, M. A. (2008). Biomedical applications of titanium and its alloys. Biological Materials Science, JOM, pp. 46-49. Forman, R. G. Kearney, V. E., & Engle, R. M. (1967). Numerical analysis of crack propagation in cyclic-loaded structure,. Transactions ASME. Journal of Basic Engineering, 89(3), pp. 459-464. Fukumoto, S., Tsubakino, H., Inoue, S., Liu, L. T., Erasawa, M., & Mitamura, T. (1999). Surface modification of titanium by nitrogen ion implantation. Materials Science and Engineering A, 263, pp. 205-209. 120 Fukumoto, S., Tsubakino, H., & Terasawa, M. (2000). Corrosion resistance of nitrogen ion implanted titanium alloy for medical implants in physiological saline solution. Paper presented at the IEEE Xplore. Fleck, C., & Eifler, D. (2010). Corrosion, fatigue and corrosion fatigue behaviour of metal implant materials, especially titanium alloys. International Journal of Fatigue 32, pp. 929-935. Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009). Ti based biomaterials, the ultimate choice for orthopaedic implants: a review. Progress in Materials Science, 54(3), 397-425. Genel, K., Demirkol, M., & Guemez, T. (2000). Corrosion fatigue behaviour of ion nitrided AISI 4140 steel. Materials Science and Engineering A288, pp. 91100. Gordin, D. M., Busardo, D., Cimpean, A., Vasilescu, C., Hӧ che, D., Drob, S. I., Mitran, V., Cornen, M., & Gloriant, T. (2013). Design of a nitrogenimplanted titanium-based superelastic alloy with optimized properties for biomedical applications. Materials Science and Engineering C, 33(7), pp. 4173-4182. Guilherme, A. S. (2005). Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols. The Journal of Prosthesis Dental 93, pp. 378-385. Harlow, D. G. & Wei, R. P. (2001). Probability modelling and statistical analysis of damage in the lower wing skins of two retired B-707 aircraft. Fatigue & Fracture of Engineering Materials and Structures. 24, pp 523–535. Hieda, J., Niinomi, M., Nakai, M., Cho, K., Gozawa, T., Katsui, H., Tu, R., Goto, T. (2013). Enhancement of adhesive strength of hydroxyapatite films on Ti– 29Nb–13Ta–4.6Zr by surface morphology control. Journal of the Mechanical Behaviour of Biomedical Materials 18, pp. 232–239. Hirvonen, J. K., & Sartwell, B.D. (1994). Ion Implantation. ASM Handbook, Vol. 5 pp 1680-1690. Hoeppner, D.W. (1978) Corrosion fatigue: chemistry, mechanics and microstructure. NACE-2, National Association Corrosion Engineers, pp. 3-11. http://www.supraalloys.com/medical-titanium.php February 25th, 2013. Hunsperger, R. G. (Ed) (2009). Integrated optics theory and technology (6th ed.). New York, USA: Springer Science & Bussiness Media. LLC. 121 Ishihara, S., Saka, S., Nan, Z.Y., Goshima, T., & Sunada, S. (2006). Prediction of corrosion fatigue lives of aluminum alloy on basis of corrosion pit growth law. Fracture of Engineering Materials and Structures 29, pp. 472-480. Jagielski, J., Piatkowska, A., Aubert, P., Thome, L., Turos, A., & Abdul Kader, A. (2006). Ion implantation for surface modification of biomaterials. Surface & Coatings Technology, 200(22-23), pp. 6355–6361. Janssen, M., J., Zuidema, J., & Wanhillet. R.J . H. (2004). Fracture Mechanics (2nd ed.), London: Spon Press. Jiang, X. P., Wang, X. Y., Li, J.X., Man, C.-S., Shepard, M. J., & Zhai, T. (2006). Enhancement of fatigue and corrosion properties of pure Ti by sandblasting. Materials Science and Engineering A 429, pp. 30–35. Jones, D. A. (1992). Principles and Prevention of Corrosion. New York: Macmillian Publishing Company. Kabadayi, Ö. (2004). The channeled stopping powers of boron ions and range calculations in Si. Czechoslovak Journal of Physics, 54(4), pp. 461-468. Kapczinski, M. P., Carlos Gil, C., Kinast, E.J ., & Alberto dos Santos, C. (2003). Surface modification of titanium by plasma nitriding. Materials Research, 6(2), pp 265-271. Kaynak, C., Ankara, A., & Baker, T. J. (1996). Effects of short cracks on fatigue life calculations. International Journal of Fatigue 18(1), pp. 25-31. Khan, Z., & Younas, M. (1996). Corrosion fatigue life prediction for notched elastic fracture mechanics concepts. International Journal of Fatigue 18(7), pp.491498. Kim, J. J. & Young, Y. M. (2013). Study on the passive film of type 316 stainless steel, International Journal Electrochemcal Science 8, pp. 11847 – 11859. Kim J. H., Semiatin S. L., Lee, Y. H. & Lee, C. S. (2011) A self-consistent approach for modeling the flow behaviour of the alpha and beta phases in Ti-6Al-4V. Metallurgical and Materials Transaction A. 42, pp 1805-1814. Kitegava, H. (1972) in Corrosion fatigue, chemistry, mechanics and microstructure, O. Devereux eds. NACE, Houston, p.521. Kokubo, T. H., Kushitani, H., Sakka, S., Kitsugi. T., & Yamamuro, T. (1990), Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W. Journal of Biomedical Materials Research, 24, pp.721734. 122 Krupp, W. E., & Hoeppner, D. W. (1973). Fracture mechanics application in materials selection, fabrication sequencing and Inspection, Journal of Aircraft, 10(11), pp. 682-688. Leyens, C., & Peters, M. (2003). Titanium and titanium alloy: Fundamentals and Applications. Weinheim, Jermany: Weley-VCH Verlag GmbH &Co KGaA Lee, Y-L., Pan, J., Hathaway, R., & Barkey, M. (2005). Fatigue Testing and Analaysis. Theory and Practice, New York: Elsevier. Liu, Y., & Mahadevan, S. (2009). Probabilistics fatigue life prediction using an equivalent initial flaw size distribution. International Journal of Fatigue (31), pp. 476-487. Liu, X., Chu, P. K., & Ding, C. (2004). Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Materials Science and Engineering R, 47, 49-121. Luetjering, G., & Williams, J. C. (2003). Titanium. Berlin, Heidelberg: SpringerVerlag. Majumda, P., Singh, S. B. & Chakraborty, M. (2008). Elastic modulus of biomedical titanium alloys by nano-indentation and ultrasonic techniques - A comparative study. Materials Science and Engineering A 489, pp 419–425. Makhlouf, K., Sidhom, H.,. Triguia, I., & Braham, C. (2003). Corrosion fatigue crack propagation of a duplex stainless steel X6 Cr Ni Mo Cu 25-6 in air and in artificial sea water. International Journal of Fatigue 25, pp. 167-179. Marcus P. (ed.). (2002). Corrosion Mechanisms in Theory and Practice (2nd Ed.). Revised and Expanded, New York: Marcel Dekker, Inc. Mudali, U. K., Sridhar, T. M., & Raj, B. (2003). Corrosion in bio implants. Sadhana-Academy Proceeding Engineering Science 28 (3- 4), pp. 601–637. Mueller, M. (1982). Theoretical consideration on corrosion fatigue crack initiation. Metallurgical and materials Transactions A 13A, pp. 649-655. Murakami, Y., Endo, M. (1992). Experimental evidence and application. In: Proceeding of the theoretical concepts and numerical analysis of fatigue. Birmingham, (UK). Warley: Engineering Materials analysis Advisory service Ltd., Cradley Health, pp. 51-57. Murtaza, G., & Akid, R. (1996). Corrosion fatigue short crack growth behaviour in a high strength steel. International Journal of Fatigue 18, pp. 557-566. 123 Murtaza, G., & Akid, R. (2000). Empirical corrosion fatigue life prediction models of a high strength steel. Engineering Fracture Mechanics 67, pp. 461-474. Nan, Z. Y., Ishihara, S., & Goshima, T. (2008). Corrosion fatigue bihaviour of extruded magnesium alloy AZ31 in sodium chloride solution. International Journal of Fatigue 30, pp. 1181-1188. Nasab, M. B., & Hassan, M. R. (2010). Metallic Biomaterials of knee and hip-a review. Trend in Biomaterial Artificial Organs, 24(1), pp 69-82. Nastasi, M., & Mayer, M. (2006). Ion Implantation and Synthesis of Materials. Berlin, Germany: Springer. Niinomi, M. (1998). Mechanical properties of biomedical titanium alloys. Materials Science and Engineering A, 243, pp 231–236. Niinomi, M. (2003). Recent research and development in titanium alloys for biomedical applications and healthcare goods. Science and Technology of Advanced Materials, 4, Pp. 445–454. Niinomi, M.(2008). Metallic biomaterials, Journal of Artificial Organs 11, pp. 105110. Oyane, A., Kim, H.-M., Furuya, T., Kokubo, T., Miyazaki, T., & Nakamura, T. (2003). Preparation and assessment of revised simulated body fluid. Journal of Biomedical Materials Research 65A, pp. 188-195. Palmquist, A., Omar, O. M., Esposito, M., Lausmaa, J., & Thomsen, P. (2010). Titanium oral implants: surface characteristics, interface biology and clinical outcome. Journal of the Royal Society Interface 7(5), pp. 515-527. Papakyriacou, M., Mayer, H., Pypen, C., Plenk Jr, H., & Stanzl-Tschegg, S. (2000). Effects of surface treatment on high cycle corrosion fatigue of metallic implant materials. International Journal of Fatigue 22, pp. 873-886. Paris, P. C., Gomez, M. P., & Anderson, W. E. (1961). A rational analytic theory of fatigue. The Trend in Engineering 13, pp. 9-14. Pompe, W., Worch, H., Epple, M., Friess, W., Gelinsky, M., & Greil, P. (2004). Functionally graded materials for biomedical applications. Materials Science and Engineering A362, pp. 40–60. Pourbaix, M. (1966). Atlas of electrochemical equilibria in aqueous solutions. New York: Pergamon Press, pp. 307-321. Pourbaix, M., (1974) Atlas of electrochemical equilibria in aqueous solutions. 2nd English ed., Houston. 124 Raman, V., Tamilselvi, S., Nanjundan, S., & Rajendran, N. (2005). Electrochemical behaviour of titanium and titanium alloy in artificial saliva. Trends in Biomaterials Artificial Organs, 18(12), pp. 137-140. Ramsamooj, D. V., & Shugar, T.A. (2001a). Modeling of corrosion fatigue in metals in an aggressive environment. International Journal of Fatigue 23(1), pp. 301-309. Ramsamooj, D. V., & Shugar, T.A. (2001b). Model predicting of fatigue crack propagation in metal alloys in laboratory air. International Journal of Fatigue 23(1), pp. 287-300. Rautray, T. R., Narayana, R., & Kim, K.-H. (2011). Ion implantation of titanium based biomaterials. Progress in Materials Science, 56, pp. 1137-1177. Razavi, R. S, Gordani, G. R, & Man, H. C. ( 2011). A review of the corrosion of laser nitrided Ti-6Al-4V. Anti-Corrosion Methods and Materials 58, pp. 140154. Rezaie, A., Fahrenholtz, W. G., & Hilma, G.E. (2007). Effect of hot pressing time and temperature on the microstructure and mechanical properties of ZrB2– SiC. Journal of Materials Science 42, pp. 2735-2744. Ritchie, R.O. (1999). Mechanisms of fatigue-crack propagation in ductile and brittle solids. International Journal of Fracture 100, pp 55–83. Sajuri, Z. B., Miyashita, Y., & Mutoh, Y. (2005). Effect of humidity and temperature on fatigue behaviour of an extruded AZ61 magnesium alloy. Fracture of Engineering Materials and Structures 28, pp. 373-379. Sajuri, Z. B. (2005). Study on Fatigue Behaviour of Magnesium Alloy. Unpublished PhD Thesis, Nagaoka University of Technology, Nagaoka, Japan. Salazar, J. M., & Calleja, F. J. B. (1983). Correlation of hardness and microstructure in unoriented lamellar polyethylene. Journal of Materials Science 18, pp. 1077-1082. Saryanto, H., Sebayang, D., Untoro, P., & Sujitno, T. (2009). Ion implantation process of lanthanum and titanium dopants into a substrate of Fe80Cr20 alloys. Proceedings of the Malaysian Metallurgical Conference '09 (MMC'09) UNIMEP, Perlis. Schijve, J. (2009). Fatigue of Structure and Materials. Chapter 2, pp. 13-57. http://www.springer.com/ISBN:978-1-4020-6807-2. 125 Shikha, D., Jha, U., Sinha, S. K., Barhai, P. K., Kalavathy, S., Nair, K. G. M., Dash, S., Tyagi, A. K., & Kothari, D. C. (2008), Improvement in Corrosion Resistance of Biomaterial Alumina after 60 keV Nitrogen Ion Implantation, International Journal of Applied Ceramic Technology, 5(1), pp. 44-48. Shivaee, H. A., Golikand, A. N., Hosseini, H. R. M., & Asgari, M. (2010). Influence of annealing on the electrochemical behaviour of finemet amorphous and nanocrystalline alloy. Journal Materials Science 45, pp. 546-551. Silvaa, H. M., Schneiderb, S. G., & Moura N. C. (2004) Study of nontoxic aluminum and vanadium-free titanium alloys for biomedical applications. Materials Science and Engineering C 24, pp. 679–682. Sirimamilla, A. Furmanski, J. & Rimnac, C. (2013) Peak stress intensity factor governs crack propagation velocity in crosslinked ultrahigh-molecular-weight polyethylene, Journal of Biomedical Materials Research 101B (3), pp. 430435. Sriraman, M. R., & Pidaparti, R. M. (2010). Crack initiation life of materials under pitting corrosion and cyclic loading. Journal of Materials Engineering and Performance 19(1), pp.7-12. Sivakumar, M., K Mudali, U. K., & Rajeswari, S. (1994). Investigation of failures in stainless steel orthopaedic implant devices: Fatigue failure due to improper fixation of a compression bone plate. Journal Mater. Sci. Lett. 13 (2), pp. 142–145. Sivaprasad, S., Tarafder, S., Ranganath,V. R., Tarafder, M., & Ray, K. K. (2006). Corrosion fatigue crack growth behaviour of naval steels. Corrosion science 48, pp 1996-2013. Spitzlsperger, G,. (2003). Very brief introduction to ion implantation for semiconductor manufacturing. http://www.gs68.de/tutorials, May, 2003. Son, C-Y, Yoon, T. S, & Lee, S. (2009). Correlation of microstructure with hardness, wear resistance, and corrosion resistance of powder-injection-molded specimens of Fe-alloy powders. Metallurgical and Materials Transaction A. 40, pp. 1110-1117. Song, H.-J. Kim, M.-K. Jung, G.-C. Vang, M.-S. & Park, Y.-J. (2007). The effect of spark anodizing treatment of pure titanium metals and titanium alloys on corrosion characteristics. Surface & Coating Technology 201, pp. 8738-8745. 126 Stephens, R. I., Fatemi, A., Stephens, R., & Fuchs, H. O. (2001). Metal Fatigue in Engineering. (2nd Ed.), New York: John Wiley & Sons, Inc. Stroosnijder, M. F. (1998). Ion implantation for high temperature corrosion protection. Surface and Coatings Technology, 100-101, pp. 196-201. Sun, Q. Y., Song, X. P. & Gu, H. C. (2001). Cyaclic deformation behaviour of commercially pore titanium at cryogenic temperature. International Journal of Fatigue, 32, pp. 187-191. Sundararajan, T., & Praunseis, Z. (2004). The effect of nitrogen-ion implantation on the corrosion resistance of titanium comparison with oxygen- and argon-ion implantations. Materiali in Technologije, 38(1-2), pp. 19 – 24. Suresh, S. (1998). Fatigue of Materials, 2nd edition, Cambridge Univ. Press,UK. Suzuki, K. (2010). Analysis of ion implantation profiles for accurate process/device Simulation: Ion implantation profile data based on tail function. FUJITSU Science and Technology Journal 46(3), pp. 307-317. Tam, B., Khan, M. I., & Zhou, Y. (2011). Mechanical and functional properties of laser-welded Ti-55.8 Wt pct. Ni Nitinol wires. Metallurgical and Materials Transactions A 42, pp. 2166-2175. Tamilselvi, S., & Rajendra, N. (2006). Electrochemical studies on the stability and corrosion resistance of Ti-5Al-2Nb-1Ta alloy for biomedical applications. Trends in Biomaterials Artificial Organs 20(1), pp. 49-52. Tanaka, T., Hakayama, H. & Kato, M (1996) Improvement of fatigue properties by ion implantation method, Paper presented at the Fatigigue'96: Proceeding of the Sixth International Fatigue Congress, Berlin.Germany. Teoh, S. H. (2000). Fatigue of biomaterials: a review. International Journal of Fatigue 22, pp. 825-837. Upadhyaya, Y. S., & Sridhara, B. K. (2012) Fatigue life prediction: A continuum damage mechanics and fracture mechanics approach.. Materials and Design, 35. pp. 220-224. Vadiraj, A., & Kamaraj, M. (2007). Effect of surface treatments on fretting fatigue damage of biomedical titanium alloys. Tribology International 40, pp. 82–88. Van Noort, R. (1987). Titanium: the implant material for today. Journal of Material Science 22, pp. 3801-3811. Vardiman, R. G., & Kant, R. A. (1982). The improvement of fatigue life in TI6Al4V by ion implantation. Applied Physics, 53, pp. 690-694. 127 Velten, D., Biehl, V., Aubertin, F., Valeske, B., W. Possart, W., & Breme, J. (2002). Preparation of TiO2 layers on cp-Ti and Ti6Al4V by thermal and anodic oxidation and by sol-gel coating techniques and their characterization. Journal Biomedical Materials Research, A59(1), pp. 18-28. Vera, R., Rosales, B. M., & Tapia, C. (2003). Effect of the exposure angle in the corrosion rate of plain carbon steel in a marine atmosphere. Corrosion Science, 45: pp. 321-337. Wahab, M. A., & Sakano, M. (2001). Experimental study of corrosion fatigue behaviour of welded steel structures. Journal of Materials Processing Technology 118, PP. 117-122. Wen, F. L., & Lo, Y.-L. (2007). Surface modification of SKD-61 steel by ion implantation technique. Journal of Vacuum Science and Technology 25(4), pp. 1137-1142. Williams, D. F. (2008). On the mechanisms of biocompatibility. Biomaterials 29, pp. 2941–2953. Winston, R. R., & Uhlig, H. H. (2008). Corrosion and Corrosion Control: An Introduction to Corrosion Science and Engineering (4th ed.). Canada: John Wiley. Woolley, E. (1997). Surface hardening by ion implantation, Materials World 5(10), pp. 515-516. Xie, J., Alpas, A. T., & Northwood D. O. (2002). A mechanism for the crack initiation fatigue of Type 316L stainless steel in Hank‟s solution. Materials Characterization 48, pp. 271-277. Xiang, Y., Lu, Z., & Liu, Y. (2010). Crack growth-based fatigue life prediction using an equivalent initial flaw model. Part I: uniaxial loading. International Journal of Fatigue, 32(2) pp. 341–349. Xu, W., Liu, J., & Zhu, H. (2011). A study on the hardness and elastic modulus of friction stir welded aluminum alloy thick plate joints using microindentation. Journal of Materials Science,46(5), pp. 1161–1166. Yu, J., Zhao, Z.J., & Li, L.X. (1993). Corrosion fatigue resistance of surgical implant stainless steels and titanium alloys. Corrosion Science 35 (1-4), pp.587–597. Zavanelli, R. A., Guilherme, E. P. H., Ferreira, I., & de Alamida Rollo, J. M. D. (2000). Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V 128 alloys in different storage environments. Journal of Prosthetic Dentistry 84, pp. 274-279. Zhang, Y., Bae, I- T., Sun, K., Wang, C., Ishimaru, M., Zhu, Z., Jiang, W., & Weber, W. J. (2009). Damage profile and ion distribution of slow heavy ions in compounds. Journal Applied Physics 105(10)104901.doi:10.1063/1.3118582. Ziegler, J. F., Biersack, J. P., & Littmark, U. (1985 ). The Stopping and Range of Ions in Solids. New York: Pergamon Press.
© Copyright 2026 Paperzz