Metso MCA Measurement Display - 2 displays, toggle with Enter – Menu structure & key functions 3def 20.12.11 14:35 MCA = 0.00 %Cs Lab = 0.00 %Cs Filler = 0.00 % Kaolin = 0.0 % CaCO3 = 0.0 % Talc = 0.0 % TiO2 = 0.0 % Chem = 0.0 % MCA con = 0.0 % Lab con = 0.0 % Filler sens. = 0.0 % Offset Cum. Offset 1 2abc Lo Cs (4mA) Hi Cs (20mA) Filtering Fault sig = 0.00 % = 10.00 % =1s = 3.7 mA Trend Int: Position: Language: Temp unit: Password: Act siglev: 10 MIN POS-1234 ENGLISH DEG C N ON 3def 1 = Sensor Electronics 2 = TCU 4ghi Date Time = 0.0 % = 0.0 % 4ghi = 0.00 % = 0.0 % = 0.0 % = 0.0 % = 0.0 % = 1.00 5jkl 20.12.11 08:15:00 Lab = 3.08 % MCA = 3.00 Cum.offset = 0.00 %Cs T = 53.6 C Att = 45.2 dB 6mno 20.12.11 08:15:00 MCA = 3.00 %Cs Att = 45.2 dB T = 53.6 C ...ENTER Metso MCA Calibration Guide 20.12.11 19:17:24 Address = 0 5jkl 4ghi 3def 1 = Current output 2 = User settings 3 = Device info 4 = Set clock 5 = Address Enter to accept... Filler Kaolin CaCO3 Talc TiO2 Filler sens. = 53 % = 12.48 mA = 52.3 C = 45.6 dB 1 = Error log 2 = Diag. values 3 = Diag. alarms 1 2abc 3def - Shows error log - ENTER = scroll error log Cab temp Proc temp Mlev Rlev Mstab El drift VCO drift = 0.0 C = 0.0 C = 0.0 mV = 0.0 mV = 0.0 = 0.0 = 0.0 Ctmp max Ptemp max Ptmp min M.Lev min R.Lev min Mstab max Rstab max Eldr abs VCOdr abs = 90.0 / OFF = 100.0 / ON = 0.0 / ON = 10.0 / ON = 100.0 / ON = 20.0 / ON = 2.0 / ON = 80.0 / ON = 50.0 / ON 1 = Chemical comp 2 = Temperature comp 3 = Sensitivity corr 4 = Recipes 1 2abc 3def 4ghi Chem.comp. Comp.value MCA con Chem Lab.con = OFF = 0.00 % = 0.00 mS/cm = NaOH = 0.00 mS/cm Temp 1. 0.0 C 2. 0.0 C 3. 0.0 C 4. 0.0 C 5. 0.0 C 6. 0.0 C MCA 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % Input new sens. correction = 1.00 1 = Choose recipe 2 = Clear recipe K10953 V1.0 EN © Metso Automation, December 2011. Subject to change without prior notice 1 = Sample taking 2 = Enter lab 3 = Offset correction 4 = Filler 5 = Calib. history 6 = Sample history 2abc % Range mA Cabin T Meas Att 1 = Calibration 2 = Configuration 3 = Diagnostics 4 = Special functions 2abc 1 Press sample key to start sampling CS = 0.00 % Status: WAITING Enter Esc Main Menu 1 MCA FT 200 QT-1234 Cs = 3.12 % T = 56.7 C Status = OK Calibrating: General: MCA FT 200 QT-1234 Cs = 3.12 % T = 56.7 C = OK Status Esc 1 = Calibration 2 = Configuration 3 = Diagnostics 4 = Special functions Measurement display Main Menu 1 1 = Calibration 2 = Configuration 3 = Diagnostics 4 = Special functions Main Menu 1 = Sample taking 2 = Enter lab 3 = Offset correction 4 = Filler Calibration Menu Basic Settings: 1 = Calibration 2 = Configuration 3 = Diagnostics 4 = Special functions 2abc 1 2abc 4ghi 1 = Current output 2 = User settings 3 = Device info 4 = Set clock 5 = Address Lo Cs (4mA) Hi Cs (20mA) Filtering Fault sig = 0.00 % = 10.00 % =1s = 3.7 mA Trend Int: Position: Language: Temp unit: Password: Act siglev: 10 MIN POS-1234 ENGLISH DEG C N ON Date Time 20.12.11 19:17:24 Enter to accept... Address = 0 5jkl A - Collect lab. sample Main Menu 1 = Sample taking 2 = Enter lab 3 = Offset correction 4 = Filler Configuration Menu Press sample key to start sampling CS = 0.00 % Status: WAITING - Waiting for sampling - Sample = start sampling Press sample key to stop sampling CS = 3.37 % Status: SAMPLING - Collect samples for lab. evaluation - Sample = stop sampling Sampling ready Average Cs = 3.34 % Min: 3.30 Max: 3.38 T = 55.3 C - Stores average values during sampling - Exit sampling result: Esc 1 Sample - Set 4mA & 20mA output signal limits - Set filtering time Edit - Save to change value, move to next value with Enter Edit - To save: Save , Esc Sample B - Enter lab. values to sensor Set position (tag no.) Set date and time: Edit - Save to change value, move to next value with Enter Edit - To save: Save , Esc Change HART address if other than 0 Documentation: - Always document all basic settings, calibration data and compensations/adjustments that have been entered to the transmitter. Calibration Menu - Sample taking 1 = Sample taking 2 = Enter lab 3 = Offset correction 4 = Filler 2abc 20.12.11 14:35 MCA = 0.00 %Cs Lab = 0.00 %Cs Filler = 0.00 % Kaolin CaCO3 Talc TiO2 Chem MCA con Lab con Filler sens. = 0.0 % = 0.0 % = 0.0 % = 0.0 % = 0.0 % = 0.0 % = 0.0 % = 0.0 % Offset adjustment: 1 = Sample taking 2 = Enter lab 3 = Offset correction 4 = Filler 3def Offset Cum.offset Calibration Menu - Offset correction = 0.00 % = 0.00 % Edit to change value - Save Edit - To save: Save , Esc - Offset = Lab. – MCA Compensations / adjustments: 1 = Chemical comp 2 = Temperature comp 3 = Sensitivity corr 4 = Recipes Special functions menu - Chemical compensation Compensates for conductivity variations in the pulp suspension - Temperature compensation Included from factory, but can be fine tuned if necessary - Sensitivity correction Set for wood fibers, can be tuned for other materials - Recipes If one calibration cannot cover the entire consistency span, up to 4 recipes can be used For more detailed information refer to Metso MCA manuals! Calibration Menu - Enter lab - Enter lab. value Edit - Save to change value Edit - To save: Save If pulp contains fillers: - Enter amount of filler as a percentage of total cons. - Also enter the proportional amount of each filler type For chemical compensation: - Enter conductivity of lab. sample to calibrate MCA conductivity measurement Start editing, change values, save changes Edit Save Move to next value, scroll function Enter Move up in menu structure Esc Scroll in display, change values Sample Store values for calibration 0 ... 9wxyz Select menus, edit values
© Copyright 2025 Paperzz