Indoor unit(s) : Outdoor unit : Brand : Item symbol value unit

Information requirements
This information includes the results of calculation of the seasonal energy consumption and efficiency for air conditioner
in regards to ErP pursuant to the Commission Regulation(EU) No.206/2012 and No.626/2011. Information to identify the
model(s) to which the information relates to:
AIR CONDITIONER
TYPE
: LCAC
Indoor unit(s)
: JTKE12BXEEBM-RX
Outdoor unit
: JUKE12BYEEBMO-X
Brand
: MIDEA
if fuction includes heating : Indicate the heating season
the information relates to. Indicated values should relate to one
heating season at a time. Include at least the heating season
'Average'.
Average
Y
(mandatory)
Warmer
Y
(if designated)
Function (indicate if present)
cooling
Y
heating
Y
Colder
(if designated)
Item
symbol
value
unit
Design load
Item
N
symbol
value
unit
Seasonal efficiency
cooling
Pdesignc
3.5
kW cooling
SEER
6.1
-
heating/Average
Pdesignh
3.6
kW heating/Average
SCOP/A
4.0
-
heating/Warmer
Pdesignh
3.5
kW heating/Warmer
SCOP/W
5.1
-
heating/Colder
Pdesignh
x,x
kW heating/Colder
SCOP/C
x,x
-
Declared capacity(*) for cooling, at indoor
temperature
27(19)℃ and outdoor temperature Tj
Item
Declared energy efficiency ratio(*), at indoor temperature
27(19)℃ and outdoor temperature Tj
symbol
value
unit
Tj = 35℃
Pdc
3.500
Tj = 30℃
Pdc
Tj = 25℃
Tj = 20℃
Item
symbol
value
unit
kW Tj = 35℃
EERd
3.76
-
2.629
kW Tj = 30℃
EERd
5.60
-
Pdc
1.761
kW Tj = 25℃
EERd
7.71
-
Pdc
1.042
kW Tj = 20℃
EERd
9.39
-
Declared capacity(*) for heating/Average season, at Declared coefficient of performance(*)/Average season, at indoor
indoor temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Item
symbol
value
unit
Tj = -7℃
Pdh
3.185
Tj = 2℃
Pdh
2.009
Tj = 7℃
Pdh
1.278
Tj = 12℃
Pdh
1.272
Tj = bivalent
temperature
Tj = operating limit
Pdh
3.185
Pdh
2.743
Item
symbol
value
unit
kW Tj = -7℃
kW Tj = 2℃
COPd
2.81
-
COPd
3.89
-
kW Tj = 7℃
kW Tj = 12℃
COPd
5.07
-
COPd
6.17
-
COPd
2.81
-
COPd
2.33
-
Tj = bivalent
kW
temperature
kW Tj = operating limit
Declared capacity(*) for heating/Warmer season, at
Declared coefficient of performance(*)/Warmer season, at indoor
indoor temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Item
Tj = 2℃
Tj = 7℃
Tj = 12℃
symbol
value
unit
symbol
value
unit
Pdh
3.500
COPd
3.32
-
Pdh
2.328
kW Tj = 2℃
kW Tj = 7℃
Item
COPd
4.80
-
Pdh
1.285
kW Tj = 12℃
COPd
6.12
-
Tj = bivalent
temperature
Tj = operating limit
Pdh
3.500
Pdh
3.500
Tj = bivalent
temperature
kW Tj = operating limit
kW
COPd
3.32
-
COPd
3.32
-
Declared capacity(*) for heating/Colder season, at
Declared coefficient of performance(*)/Colder season, at indoor
indoor temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Item
symbol
value
Tj = -7℃
Pdh
x,x
Tj = 2℃
Pdh
x,x
Tj = 7℃
Pdh
x,x
Tj = 12℃
Pdh
Tj = bivalent
temperature
Tj = operating limit
Tj = -15℃
unit
symbol
value
unit
kW Tj = -7℃
kW Tj = 2℃
COPd
x,x
-
COPd
x,x
-
COPd
x,x
-
x,x
kW Tj = 7℃
kW Tj = 12℃
COPd
x,x
-
Pdh
x,x
kW
COPd
x,x
-
Pdh
x,x
COPd
x,x
-
Pdh
x,x
kW Tj = operating limit
kW Tj = -15℃
COPd
x,x
-
Bivalent temperature
Item
Tj = bivalent
temperature
Operating limit temperature
heating/Average
Tbiv
-7
℃
heating/Average
Tol
-15
℃
heating/Warmer
Tbiv
x
℃
heating/Warmer
Tol
x
℃
℃
heating/Colder
Tol
x
℃
kW heating/Average
EERcyc
x,x
-
Pcych
x,x
for heating
Degradation
Cdc
0.25
co-efficient cooling
Electric power input in power modes other than
'active
mode'
off mode
Poff
0.009
kW heating/Warmer
Degradation
co-efficient heating
COPcyc
x,x
-
Cdc
0.25
-
kW cooling
QCE
201
kWh/a
standby mode
kW heating/Average
Qhe
1260
kWh/a
kW heating/Warmer
Qhe
x
kWh/a
kW heating/Colder
Qhe
x
kWh/a
heating/Colder
Tbiv
x
Cycling interval capacity
for cooling
Cycling interval efficiency
Pcycc
x,x
Psb
0.009
thermostat-off
Pto
0.051
mode
crankcase heater
Pck
0
mode
Capacity control(indicate one of the options)
Item
fixed
staged
variable
Contact details for
obtaining more
information
symbol
value
Annual electricity consumption
Other items
unit
Item
symbol
value
unit
Sound power level
Y/N
LWA
57/60
dB(A)
(indoor/outdoor)
Global warning
Y/N
GWP
2088 kgCO2 eq
potential
Rated air flow
Y
x
m3/h
(indoor/outdoor)
Address: No. 6 Midea Avenue, Beijiao, Shunde, Foshan City, Guangdong Province,
P.R. China 528311
Telephone: +86 (0757)26338888