HVTECK SPECIFICATIONS CSA HVTECK CU 1/C 420EPR TS PVC 35KV 133% PRODUCT HIGHLIGHTS Southwire's 35KV HVTECK is a CSA copper tape shielded cable for industrial and commercial medium voltage applications. FT4, -40C, HL and 105°C rated for use in harsh Canadian environments. Rated for installation in cable trays, duct banks, direct burial, troughs, continuous rigid cable supports, and concrete encaseable. CONSTRUCTION Conductor: • Class B stranded copper - compressed or compact - in accordance with ASTM B3 and ASTM B8 Insulation Shield: • Extruded semi-conducting thermosetting polymeric layer • CSA 68.10 - Shield removal/termination requirements are printed on the surface Conductor Shield: • Extruded semi-conducting thermosetting polymeric layer • Meets requirement of ICEA, but built to CSA standards Insulation: • No-Lead EPR (ethylene propylene rubber) • Thickness: 0.420" (10.7mm) - nominal • Insulation Level: 133% - ungrounded system • 105°C rated • Helically wrapped 5 mil copper tape with 25% overlap Overall Jacket: • Black PVC (optional colours available) • Thickness: - No. 1/0 AWG to to 350 kcmil = 0.060" (1.5 mm) - 500 kcmil to 1000 kcmil = 0.075" (1.9mm) Print Legend: Copper Tape Shield: • SOUTHWIRE [symbol - lightning bolt] #P# CSA 1/C [#AWG or #kcmil] 750 kcmil] CPT CU 420EPR AIA 35kV 133% INS LEVEL 25%TS SUN RES 105°C FT4 HL LTGG [-40°C] RoHS YEAR (NESC) [SEQUENTIAL METER MARKS] Inner Jacket: • Black PVC • Thickness: - No. 1/0 AWG to No. 4/0 AWG = 0.080" (2.0 mm) - 250 kcmil to 1000 kcmil = 0.110" (2.8 mm) Armour: • Aluminum Interlocked Armour (AIA) TABLE 1 - WEIGHTS & MEASUREMENTS Diameter Over Insulation Diameter Over Insulation Shield inches 1.23 1.28 1.33 1.38 1.44 1.54 1.67 1.86 2.01 inches 1.31 1.36 1.41 1.46 1.52 1.64 1.77 1.96 2.11 mm 31.3 32.4 33.7 35.1 36.5 39.1 42.4 47.2 51.0 mm 33.3 34.4 35.7 37.1 38.6 41.7 45.0 49.7 53.5 Inner Jacket Diameter inches 1.51 1.56 1.59 1.64 1.76 1.90 2.03 2.21 2.36 mm 38.4 39.5 40.3 41.7 44.7 48.3 51.6 56.1 59.9 Armour Diameter inches 1.82 1.90 1.94 1.99 2.11 2.51 2.38 2.56 2.71 mm 46.2 48.1 49.2 50.6 53.5 63.8 60.5 65.0 68.8 Approx. Overall Diameter inches 1.94 2.02 2.06 2.11 2.23 2.37 2.53 2.71 2.86 mm 49.3 51.2 52.2 53.6 56.6 60.2 64.3 68.8 72.6 Approx. Weight of Cable lbs/ 1000ft kg/km 1764 2626 1948 2898 2122 3158 2331 3469 3928 2639 4655 3128 5713 3839 7249 4871 8709 5852 Max. Reel Weight (reel and cable)** lbs 11,259 11,293 11,741 12,045 12,112 12,502 13,072 13,732 14,430 kg 5107 5122 5326 5463 5494 5671 5929 6229 6545 Max. Reel Diameter** inches 108 108 108 108 108 108 108 108 108 m 2.74 2.74 2.74 2.74 2.74 2.74 2.74 2.74 2.74 NOTE: These are minimum dimensions as per CSA Standards. * Other conductor sizes and outer jacket colours are available upon request. (#s in brackets represent # of strands / conductor) ** These are maximum reel sizes and cable lengths. Standard sizes and lengths will be supplied. Reel sizes are not guaranteed. The factory reserves the right to make changes as necessary to optimize manufacturing requirements. © 2013 Southwire Company, All Rights Reserved. Max. Reel Width** inches 70.5 70.5 70.5 70.5 70.5 70.5 70.5 70.5 70.5 m 1.79 1.79 1.79 1.79 1.79 1.79 1.79 1.79 1.79 Max. Length of Cable on Reel** feet 5500 5000 4800 4500 4000 3500 3000 2500 2200 m 1676 1524 1463 1372 1219 1067 914 762 671 SPS_R41_INDUSTRIAL-E(13-11) HVTECK Product Code CU135R41-010 CU135R41-020 CU135R41-030 CU135R41-040 CU135R41-250 CU135R41-350 CU135R41-500 CU135R41-750 CU135R41-1000 Conductor Conductor Size* Diameter AWG or Kcmil inches mm 1/0 (19) 0.362 9.2 2/0 (19) 0.405 10.3 3/0 (19) 0.456 11.6 4/0 (19) 0.512 13.0 250 (37) 0.558 14.2 350 (37) 0.661 16.8 500 (37) 0.790 20.1 750 (61) 0.968 24.6 1000 (58) 1.117 28.4 HVTECK SPECIFICATIONS CSA HVTECK CU 1/C 420EPR TS PVC 35KV 133% DESIGN Qualification Standards: • CSA C68.10 - Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV • CSA C68.3 - Shielded & Concentric Neutral Power Cable 5 to 46 kV • CSA C22.2 No. 174 - Cables in Hazardous Locations • ICEA S-93-639 (NEMA WC 74) 5 to 46 kV - Shielded Power Cable • AEIC CS-8 - Qualification Testing Requirements Product Ratings: • CSA C22.2 No. 2556 & No. 0.3. - Wire and Cable Test Methods • CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating • CSA HL - for Hazardous Locations rating • CSA FT4 - for Flame Retardancy rating • CSA SUN RES - for Sunlight Resistant rating Flame Test Ratings: • FT1 - Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test) • FT4 - Flame Test (70,000 BTU/Hr - Vertical Tray Flame Test) • IEEE 1202 - Flame Test (70,000 BTU/Hr - Vertical Tray Test) • IEEE 383 - Flame Test (70,000 BTU/Hr) • ICEA T-29-520 - Vertical Cable Tray Flame Test (210,000 BTU/Hr) • -40°C - CSA Cold Bend and Impact Temperature Operating Temperatures: COPPER CONDUCTOR • -25°C - Min. Installation Temperature CONDUCTOR SHIELD • 105°C - Max. Continuous Operating Temperature INSULATION • 140°C for Emergency Overload Temperature INSULATION SHIELD • 250°C for Short Circuit Temperature COPPER TAPE SHIELD INNER JACKET ALUMINUM INTERLOCK ARMOUR OVERALL PVC JACKET End View TABLE 2 - ENGINEERING SPECIFICATIONS HVTECK Product Code CU135R41-010 CU135R41-020 CU135R41-030 CU135R41-040 CU135R41-250 CU135R41-350 CU135R41-500 CU135R41-750 CU135R41-1000 Minimum Bend Radius AWG or Kcmil inches 1/0 (19) 23.3 2/0 (19) 24.2 3/0 (19) 24.7 4/0 (19) 25.3 250 (37) 26.7 350 (37) 28.5 500 (37) 30.4 750 (61) 32.5 1000 (58) 34.3 mm 591 614 627 644 679 723 771 825 871 Maximum Pulling Tension Ω/ lbs Newtons 1000ft 845 3758 0.1020 1065 4736 0.0810 1342 5971 0.0642 1693 7530 0.0510 8896 0.0431 2000 2800 12455 0.0308 4000 17793 0.0216 6000 26689 0.0144 8000 35586 0.0108 Ω/ km 0.3347 0.2658 0.2106 0.1673 0.1414 0.1011 0.0709 0.0472 0.0354 Ω/ 1000ft 0.1280 0.1020 0.0807 0.0639 0.0543 0.0390 0.0275 0.0188 0.0144 Ω/ km 0.4200 0.3347 0.2648 0.2097 0.1782 0.1280 0.0902 0.0617 0.0472 * Other conductor sizes and outer jacket colours are available upon request. (#s in brackets represent # of strands / conductor) † Ampacities are based on Table 1 of the 2012 Canadian Electrical Code Part I - 90°C column ‡ Ampacities are based on Table D8A and Detail 1 of Diagram B4-1 of the 2012 Canadian Electrical Code Part I © 2013 Southwire Company, All Rights Reserved. Inductance L (triplexed) mH/ 1000ft 0.1599 0.1554 0.1494 0.1440 0.1420 0.1354 0.1285 0.1203 0.1148 mH/ km 0.5247 0.5099 0.4902 0.4724 0.4659 0.4444 0.4217 0.3947 0.3767 Capacitance C µF/ 1000ft 0.0401 0.0429 0.0460 0.0495 0.0519 0.0581 0.0657 0.0754 0.0839 µF/ km 0.1317 0.1406 0.1511 0.1624 0.1703 0.1905 0.2154 0.2473 0.2752 Inductive Reactance Capacitive Reactance XL XC Short Circuit Current @60Hz @60Hz @60Hz (triplexed) (wrt grounded shield) MΩ• MΩ• Ω/ Ω/ 1000ft km kAmps 1000ft km 0.0661 0.0201 7 0.0603 0.1978 0.0619 0.0189 10 0.0586 0.1922 0.0576 0.0176 13 0.0563 0.1848 0.0536 0.0163 14 0.0543 0.1781 0.0511 0.0156 17 0.0535 0.1756 0.0457 0.0139 25 0.0511 0.1675 0.0404 0.0123 35 0.0485 0.1590 0.0352 0.0107 51 0.0453 0.1488 0.0316 0.0096 70 0.0433 0.1420 Allowable Allowable Ampacities in Ampacities Free Air Direct Buried (30°C ambient)† (20°C ambient)‡ Amps 260 300 350 405 455 570 700 885 1055 Amps 245 285 330 385 425 530 660 845 980 SPS_R41_INDUSTRIAL-E(13-11) Conductor Size* AC Resistance Rac DC Resistance Rdc Ratios @ 90°C & 60Hz @ 25°C (each conductor)
© Copyright 2024 Paperzz