Presence detector OPP-PIR-2 • Ceiling installation 360° range • 24 V AC/DC connection • Shutoff lag: 10s – 30 min, selectable • Switch-on lag: 0 – 10 min, selectable • Relay output: one changeover contact Technical Data Infrared sensor:Omni-directional Power supply: 24 ± 2 V AC/DC Sensor range: Height x 2.5 at 25 °C Power consumption: 5 mA Response velocity: 0.1 bis 3 m/s Output signal: 1 changeover contact, 24 V AC/DC; 0.2 A Protection type: IP 41 Ambient conditions: -20 °C – + 60 °C, max. 95 % RH Weight: 85 g Dimensions (Ø x H): 110 x 44 mm Installation height: 2.4 – 4.2 m Cable bushing: From rear with punch out for cable IY(ST)Y4x2x0,8 Color:white Product description OPP-PIR-2 is a presence detector specifically designed for HVAC applications in a visually appealing, white housing. The lens has a detection angle of 360° to reliably detect motion. Detection range Front view Side view 0 s 10 s 30 s 1 min 5 min 10 min Installation height 2.4 m 3.0 m 3.6 m 4.2 m Sensor range 7.5 m 9.0 m 10.5 m 6.0 m 10 s 1 min 5 min 10 min 20 min 30 min Attention Disconnect the detector from power before repositioning the jumper! Sensor ventilation air conditioning | Data sheet No. 15601 | Version 05-2015 | 1 | 2 Presence detector OPP-PIR-2 Connecting diagram Function check Turn on the power supply to the detector. Wait 30 seconds to complete the warmup phase. Enter the detection space and walk around at normal speed. The LED lights up as soon as the sensor is triggered. Contacts are shown disconnected from power. The relay is energized on motion. Contact COM - NO is then closed. Circuit board view Installation All work (such as installation, electrical connection, startup, operation, and maintenance) must only be performed by sufficiently qualified tradesmen. The respectively applicable local rules and regulations (e.g. national building codes, electrical/VDE regulations, etc.) must be observed. Installers and operating entities are required to sufficiently familiarize themselves before startup. Read the product description before operating the equipment. Verify that the product can be used for the relevant application without restrictions. We are not liable for printing errors and changes after printing. Appropriate use implies compliance with operating and installation instructions. We are not liable for losses due to inappropriate use. Unauthorized or inappropriate manipulations or modifications of the device render the operating permit, the product warranty and warranty claims null and void. Do not expose the sensor to direct sun irradiation or high heat. Do not obstruct the detection range with flowers, furniture, or other objects. Dimensions 1. Open front cover by loosening the captive screw. Remove the electronic circuit board from the base plate. 2. Now punch out the appropriate perforated holes. Then insert the cable and mount the detector to the ceiling with screws and dowels. 3. Reinsert the electronic circuit board back into the bracket. The cables now need to be connected correctly. 4. Seal any unused holes with putty to prevent insects from entering the sensor cavity. This can result in erroneous triggering. 5. Verify that both jumpers are inserted properly. Finally, secure the front cover with screws. 44 mm Oppermann Regelgeräte GmbH | Im Spitzhau 1 | 70771 Leinfelden-Echterdingen, Germany Phone +49 711 72723560 | Fax +49 711 7280527 | [email protected] | www.oppermann-regelgeraete.de 2 | 2 | Sensor ventilation air conditioning | Data sheet No. 15601 | Version 05-2015 Specifications subject to change.
© Copyright 2026 Paperzz