Water Activity Science DA7200 for Water Activity New NIR approach to fast water activity measurement. DA7200 utilizes NIR spectroscopy to determine the activity of the water in the sample. D A7200 measures water activity by shining a bright light on a sample and collecting the reflected spectrum of light. Reflected light from a sample is characteristic of the composition of that sample. In other words, a sample with a water activity of 0.300 will reflect light differently than a sample with a water activity of 0.320. DA7200 measures this reflected light and converts it to water activity values using specialized software. Since there is no measurement of the air above the sample, no equilibration time is needed. In addition, because the method of detection travels at the speed of light along a fiber-optic cable, the time for a water activity measurement is almost instantaneous. DA7200 requires a product specific calibration. Once programed, the water activity of your product is measured with the touch of a button. No equilibration necessary. Call Now. DECAGON DEVICES 950 NE Nelson Court Pullman, Washington 99163 800-755-2751 fax 509/332-5158 [email protected] www.aqualab.com DA7200 Specifications Water Activity Science Accuracy ±0.02 aw Reference Ceramic Automatic Range 0.100 to 1.000 aw Internal Computer 1 GHz, 256 MB RAM, 20 GB HDD Rapid Analysis of Water Activity Operating Platform Windows XP, Touch Screen Easy Sample Presentation Wavelength Stability < 0.2 nm/year Communication Ports 2 x USB, 1 x Parallel, 1 x LAN, 1 x Keybord, 1 x Mouse, 1 x External Monitor Non-Contact and Non-Destructive Analysis Resolution 3.125 nm/diode Power Requirement 115/230 V, 50/60 Hz, 115 W Non-Moving Optics. Detector T.E. cooled 256 elements InGaAs. Internal Line Source Reference Humidity 35 – 80 % non condensing Wavelength Range 950 – 1650 nm Wavelength Accuracy < 0.3 nm Data/Spectral Collection Rate Approx. 100 spectra/second Noise < 0.00006 AU over 3s measuring time Optics F/3 Dimensions (HxDxW) 556x375x370 mm with Touch Screen in upright position Net Weight 21 kg Sample Presentation Non-contact, down view, rotating sample dish SAMPLE MEASURING AREA Ambient Temperature 5 – 35 °C Grating Gold-coated ruled stationary grating Lamp lifetime Approx. 5000 hrs, operator exchangeable Large sample cup Ø 140 mm. Area: 154 cm2 (measured 108 cm2) Small sample cup Ø 75 mm. Area 44 cm2 (measured 44 cm2) DECAGON DEVICES 950 NE Nelson Court Pullman, Washington 99163 800-755-2751 ©2005 Decagon Devices, Inc. Printed in USA. fax 509/332-5158 [email protected] www.aqualab.com
© Copyright 2026 Paperzz