Oregon Construction Contractor Board #151216 1567 Happy Lane, Eugene, OR 97401 (541)302-0879 Home Inspection Report Prepared for: John Smith Property location 1234 Sample Street Eugene, Oregon The Home Report ©2006 1 1234 Sample Street This report contains confidential information and is for the exclusive use of the client, John Smith. Distribution to other parties is prohibited by contractual agreement. Date of Inspection: September 9th, 2006 THR File #60909S Paul Daniel, Oregon Certified Home Inspector #507 About This Report This inspection report is a result of a visual inspection of the subject property and while not technically exhaustive, includes all structural and service components readily observable. The inspection is visual only and there has been no destructive testing or disassembly of components, other than removal of cover plates. Furniture, carpets, insulation or other materials that may prevent inspection have not been moved or removed. The inspection does not include examination for hazardous materials. All conclusions are the professional opinion of the inspector and are not a guarantee or warranty of the performance of the structure, systems, or components. Please note that this is not a code inspection and as such does not indicate the compliance or lack of compliance with local building codes. Any estimates of remaining serviceable life, repair costs, etc. are advisory only. Individual units or systems vary widely in their performance. We encourage you to conduct a pre-settlement walk through to confirm conditions just prior to closing. Damage or failure of components may occur between the time of inspection and your occupancy of the property. Property Description 1.1 The subject structure is a two level house built approximately four years ago. The house is located on a slightly elevated lot in a suburban area. The home faces Sample Street to the west. The property includes a covered patio and garage. The house has in general been adequately maintained. The Home Report ©2006 2 1234 Sample Street Lot & Grounds 2.1 Driveway: Poured concrete. 2.2 Walkways: Poured concrete. 2.3 Patio: There is a poured concrete patio which is covered by the main roof. 2.4 Porch: The porch is set under the main part of the roof. The roof extension is supported by wood posts and is in good condition. 2.5 Site grading/drainage: The house sits on a slightly elevated site which should provide generally good drainage. There is a slope/swale on the east boundary which appears likely to have been created to divert water away from the property on the east side. 2.6 Site grading/clearance: Clearance between soil and siding is generally good around the home. 2.7 Fence: There is a vertical board fence which has been installed using pressure treated posts, an advantage. 2.8 Gates: The gates function adequately. 2.9 Hose bibbs: Two hose bibbs installed. Staining suggests minor leaks may exist during use, but were not evident during testing. I recommend monitoring. The Home Report ©2006 3 1234 Sample Street Exterior 3.1 Roof water control: There is a continuous ‘K’ style aluminum gutter system installed on the house. Aluminum downspouts are used also. This is a good quality system. The downspouts connect to an underground drainage system, an advantage. Confirmation of drain function and outlet are not a part of this inspection. 3.2 Siding: The house is mainly covered with an engineered product known as fiber cement board. It is manufactured from wood fibers and cement, a component of concrete. The version of the product installed is manufactured to look like horizontally installed board siding. To date this siding material has shown good durability. The installation and condition of the siding is generally good. Maintain a good caulk seal at joints, and intersections with windows, doors, etc. There are some locations where movement has opened up joints, and recaulking is needed in these areas at this time. There are small areas of brick veneer installed on the lower parts of the west side. There are gaps at the junction of the brick and fiber cement siding. I recommend the gaps are sealed to prevent possible water entry. Sample views. The Home Report ©2006 4 1234 Sample Street 3.3 Fascia: A fascia board is not installed with this design. The barge boards on the gables are composite wood boards. The lower edge of one board on the east side appears cracked. I recommend the crack is sealed. Composite wood is vulnerable to moisture damage and decay if not adequately protected from adverse conditions. I recommend the barge boards are monitored and maintained as required. 3.4 Soffits (eaves overhang): There are gaps around the soffit blocking between truss tails. The largest gaps are on the porch area and south side. See locating diagram. These gaps may allow insect entry to the attic. I recommend any gap one quarter inch or wider is sealed. Sample views. 3.5 Trim: Wood, good condition. 3.6 Paint: Generally good. 3.7 Windows: Vinyl frame windows with insulating glass are used throughout the house. The west window in the living room does not slide easily and may require adjustment. The window screen is slightly bent creating gaps. The Home Report ©2006 5 1234 Sample Street 3.8 Patio door: This is a vinyl frame sliding door, with insulating safety glass. There is no screen door installed. 3.9 Front door: Wood. Roof 4.1 Observation method: Walked on roof. 4.2 Description: This is a gable style roof of moderate pitch. The roofing material is laminated architectural composition shingles; a good quality material. 4.3 Installation: The quality of installation is generally good. 4.4 Condition: The shingles are approximately two years old, and are in good condition. This type of roof is typically warranted for twenty-five years or more. 4.5 Roof deck: Oriented strand board panels. 4.6 Flashing: The metal flashing is generally well installed and in good condition. The lower flange of a vent jack is not flush with the roof surface. See locating diagram. The gap was occupied by wasps on the day of inspection. I recommend the wasps are removed and flange is secured with fastener; the fasteners should be sealed with mastic. Several live wasp nests were observed, mainly under the roof overhang. I suggest the nests are removed to prevent potential sting hazard. See sample view on the following page. The Home Report ©2006 6 1234 Sample Street A fastener securing a roof jack flange is exposed and should be sealed with mastic. See locating diagram. 4.7 Vents: Metal. 4.8 Moss: There is no significant moss growth on the roof. Structure 5.1 Foundation: The foundation walls are poured concrete, with footings. 5.2 Framing/walls: Typical wood frame construction. Though structural components were generally concealed and not visible for inspection, no signs of failure were evident. 5.3 Floor structure: Concrete piers, wood posts, and 4x8 beams set at thirty-two inch intervals comprise the floor support system. A board subfloor is installed. One support post close to the west side is loose. See locating diagram. I recommend shims are installed to restore load. See photographs on the following page. The Home Report ©2006 7 1234 Sample Street 5.4 Roof structure: 2x4 prefabricated trusses set on twenty-four inch centers. 5.5 Roof deck: Oriented strand board panels. 5.6 Ceiling joists: Lower truss chords. Crawlspace 6.1 Access: There is a scuttlehole in the hall closet. 6.2 Vapor barrier: Plastic sheet installed. 6.3 Debris: There is no significant debris present. 6.4 Underfloor insulation: Fiberglass batt insulation installed. 6.5 Ventilation: Ventilation is provided by screened vents in the foundation walls. Several vent openings are at grade level, (due partly to the recent installation of barkdust). This could allow water to flow into the vents. Debris may also accumulate and block the vents. I recommend soil is removed from the area around the vents to provide a minimum of two inches clearance below the vent opening. Alternatively vent wells could be installed. See sample view on the following page. The Home Report ©2006 8 1234 Sample Street 6.6: Moisture: The crawlspace was dry on the day of inspection. However, staining on the vapor barrier suggests water infiltration has occurred previously. The staining indicates the water has been approximately one inch deep covering more than half of the crawlspace floor. It is possible this water infiltration occurred during construction. However, water staining may also have been caused by water intrusion since construction. This type of water intrusion can be caused by soil type, exterior grade, and drainage dynamics around the house. As exterior soil becomes saturated, water seeps under the foundation wall and into the foundation grade, which is lower than the exterior grade. Water passes on to the top of the vapor barrier at the edges and seams. I recommend the crawlspace is monitored for water following periods of prolonged or heavy rainfall. If water is found to accumulate the crawlspace floor should be re-graded and trenched to direct water to the crawlspace drain in the SW part of the crawlspace and piped off site. The installation of a few inches of gravel would facilitate water movement under the vapor barrier and to raise the vapor barrier out of any puddles. See sample views of water staining on the following page. The Home Report ©2006 9 1234 Sample Street Attic 7.1 Access: Scuttle holes located in the garage and NW bedroom closet. Insulation appears to have been installed on top of the scutlehole in the NW bedroom closet; no baffles appear to have been installed to hold insulation away. A large volume of loosefill fiberglass is likely to fall into the closet if this scutlehole is removed. All parts of the attic can be accessed from the garage scuttlehole. 7.2 Roof ventilation: Provided by soffit vents and roof vents. 7.3 Roof deck: Oriented strand board. 7.4 Room exhaust fans: Ducted to roof vent and soffit vent. 7.5 Insulation: Loosefill fiberglass. 7.6 Birds, insects, rodents: None noted. Heating System 8.1 Furnace: This house’s heating system consists of a natural gas forced air furnace. The furnace is manufactured by Coleman. This is a conventional, mid-efficiency unit, 57 KBTU input. The interior of the cabinet is dusty suggesting the furnace has not been serviced recently. I recommend cleaning and servicing. 8.2 Heat Exchanger: The small portions visible are in adequate condition. The Home Report ©2006 10 1234 Sample Street 8.3 Exhaust flue: Gases are fan forced and vented via a flexible and sheet metal manufactured flue. The flexible portion of duct is in contact with the insulation on the return air duct. This type of vent normally requires a one inch clearance. Although there is no scorching at the contact points this vent should ideally be repositioned to create adequate clearance. 8.4 Combustion air: From garage. 8.5 Air filter: The disposable filter is situated in the return air duct in the hallway ceiling. The filter is dirty and should be replaced. A second filter is installed in the bottom of the air module and was also dirty and requires cleaning. I suggest a heating engineer is consulted regarding the necessity of two filters. 8.6 Thermostat: Electronic programmable thermostat. The Home Report ©2006 11 1234 Sample Street 8.7 Carbon monoxide detector: None noted. Fuel burning appliances can produce deadly carbon monoxide gas if malfunctioning. I recommend the installation of a CO detector in the home. 8.8 Ducts: Heated air is supplied to the registers through insulated ceiling ducts. The duct work appeared to be in generally good order. However, the insulation is loose creating small gaps in the insulation of the duct in the attic. I recommend insulation is re-installed. Cooling System 9.1 Overview: The system consists of an exterior compressor, and interior coils installed with the furnace. The unit was tested and functioned well. 9.2 Exterior unit: Installed on a pad south of the home. There is long grass around the unit which should be trimmed to ensure adequate air movement. The Home Report ©2006 12 1234 Sample Street 9.3 Interior coils: Not visible for inspection. 9.4 Control: Shares a thermostat with the heating system. 9.5 Ducts: In common with heating system. 9.6 Condensate: Piped to the exterior of the home. 9.7 Refrigerant line insulation: Slightly torn/deteriorated exterior section close to exterior unit. I recommend insulation be repaired or replaced. Electrical System 10.1 Service: The service entrance is via underground lines. 120, 240 volts. 200 amp capacity cable. 10.2 Main panel: A medium size, single main distribution panel with circuit breaker protection is located in the garage. There are twelve 120 volt breakers and three 240 volt breakers. Defects: There is an open cable knock out in the top of the panel which should be plugged. The Home Report ©2006 13 1234 Sample Street One 240 volt breaker is not labeled but is likely to be for the air conditioner. I recommend confirmation and labeling. There is paint overspray on some breakers including the main breaker. Although unlikely, the paint may prevent breakers tripping. I suggest evaluation by an electrician, or at minimum physically switching breakers a few times to eliminate any potential paint seal. 10.3 Distribution: The house is served by copper two wire with ground cable. The pond pump appears to be powered by a permanently installed extension lead to an exterior outlet. This is potentially hazardous; ideally a conventionally installed circuit with a cable protected by conduit and buried underground would be installed. 10.4 Outlets: Three prong grounding type. 10.5 Lights: A light switch to control the kitchen lights was not identified. I recommend consulting homeowner. 10.6 Ground Fault Circuit Interrupters (GFCIs): These are safety devices to prevent electric shock. They are now recommended for use in all areas where water is likely to be encountered (kitchen, bath, garage, outdoors). This house is likely to have ground fault interrupters in all these location. However, not all GFCIs were accessible for testing or were in use. I recommend testing when all GFCIs are accessible and not in use. 10.7 Smoke detector: The smoke detectors installed have the hush button feature as required by state law. The smoke detector had been removed from the master bedroom and should be replaced. Plumbing System 11.1 Water supply: PVC. 11.2 Distribution: PVC. 11.3 Drain and waste: ABS plastic pipe is used in this system. 11.4 Water heater: Hot water is provided by a natural gas forty gallon tank. The temperature and pressure relief valve is in place with the The Home Report ©2006 14 1234 Sample Street overflow pipe as required. The tank is strapped for safety in the event of an earthquake. 11.5 Dryer duct: The termination hood is missing. I recommend the installation of a termination hood with backdraft damper. Flexible duct is used in the crawlspace. This is a potential fire hazard and should be replaced with sheet metal duct. 11.6 Gas supply: There is a gas shut off at the meter on the south exterior of the home. Insulation 12.1 Attic: Well insulated with loosefill fiberglass and fiberglass batts. 12.2 Wall: Wall insulation was not confirmed but it is likely to have R15 fiberglass batts installed. The Home Report ©2006 15 1234 Sample Street 12.3 Underfloor: Fiberglass batts to approximately R-25. Interior 13.1 Walls: There is a small area of repair a close to the patio door likely caused by a pet. 13.2 Ceiling: There are moderately large settlement cracks in the ceiling of the living room/kitchen area. These cracks do not appear to signify any unusual movement or failure. I recommend monitoring. 13.3 Doors: The door stop in the NW bedroom is broken. 13.4 Dishwasher: Cycled satisfactorily. 13.5 Bathroom: The main bathroom tub drained slowly. Garage 14.1 Type: This is a two car, one door, built-in garage. A large volume of stored items obscured some area. 14.2 Slab: Poured concrete with typical minor settlement cracks. 14.3 Car doors: Sectional metal overhead doors. 14.4 Door operation: The door operates easily when disconnected from the opened. 14.5 Door opener: The door opener operates well and is fitted with both pressure resistance and infra-red safety reversing systems, an advantage. 14.6 Personnel door: Good. 14.7 Walls/ceiling: Finished, an advantage. The Home Report ©2006 16 1234 Sample Street Diagram N Air conditioner line insulation damaged Air conditioner Gap under roof jack Soffit gap Loose support post in crawlspace STREET CRAWLSPACE Location of crawlspace drain Loose insulation on heating duct in attic GARAGE Lower edge of bargeboard cracked Roof jack fastener exposed Dryer duct Gaps at the upper edge of brick veneer at junction with board siding The Home Report ©2006 Main gas shut-off Crawlspace vents at grade 17 Area of soffit gaps 1234 Sample Street
© Copyright 2025 Paperzz