RFA-HF (i) Collectively and individually screened instrumentation and communication cable 250 V DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Twisted pair & individual screen - two insulated cores twisted together to form a pair - plastic coated aluminium tape and a tinned copper drain wire 4. Bedding - separator tape 5. Collective screen - drain wire tinned copper IEC 60092-350 - aluminium polyester tape, coverage 100% 6. Sheath - polyolefine plastic, SHF1 EC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2 ) Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission Oil resistance (only SHF2) 150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series IEC 60811-404 conditions according to 60092-360/SHF2 Electrical data Loop resistance of pair, max. / +20°C Pair capacitance, nom. Loop inductance, nom. Insulation resistance / +20°C 0,5mm 2 0,75mm 2 80 52 55 70 0,6 0,6 ≥1500 ≥1500 1,5mm 2 24,4 90 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, manufacturer's name, production month and meter marking printed on the sheath Tel. +31 (0) 183 - 617 109, Fax +31 (0) 183 - 614 087, www.helmacab.nl Technische wijzigingen voorbehouden | Aan deze informatie kunnen geen rechten worden ontleend Subject to technicaI modifications I No rights can be derived from this information RFA-HF(i) 250V Part number 20940 20942 20944 20946 20948 20950 20952 20954 20956 20958 20960 20962 21058 21059 21100 21061 21115 21063 21065 21067 21069 21071 21073 21075 21077 21375 21377 21378 21379 21380 21381 21382 21383 21384 21385 21386 21387 21388 21389 21390 21391 21392 Number of conductors & cross-section n x mm 2 2x2x0,5 4x2x0,5 7x2x0,5 8x2x0,5 10x2x0,5 12x2x0,5 14x2x0,5 16x2x0,5 19x2x0,5 24x2x0,5 32x2x0,5 37x2x0,5 1x2x0,75 2x2x0,75 3x2x0,75 4x2x0,75 5x2x0,75 7x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 14x2x0,75 16x2x0,75 19x2x0,75 24x2x0,75 1x2x1,5 2x2x1,5 Quad 2x2x1,5 3x2x1,5 4x2x1,5 7x2x1,5 8x2x1,5 10x2x1,5 12x2x1,5 14x2x1,5 16x2x1,5 19x2x1,5 24x2x1,5 27x2x1,5 30x2x1,5 32x2x1,5 37x2x1,5 Nominal outer diameter mm Approximate weight kg/km 8,5 10,0 12,0 12,5 14,5 15,0 16,0 17,0 18,5 20,5 23,5 25,0 6,5 10,0 10,5 11,5 13,0 14,0 15,0 17,0 18,0 19,0 20,5 22,0 24,5 8,5 10,0 13,5 14,0 16,0 19,0 20,5 23,5 25,0 26,5 28,5 30,5 34,5 36,5 38,0 39,5 42,0 80 130 200 225 280 320 360 405 475 600 775 880 60 110 140 170 205 260 300 370 425 485 560 645 800 95 155 190 240 310 485 565 695 805 915 1045 1210 1535 1715 1885 2030 2305 Min. bending radius fixed installation mm 50 60 70 75 85 90 95 100 110 125 140 150 40 60 65 70 75 85 90 105 110 115 125 135 150 50 60 80 85 95 115 125 140 150 160 170 185 205 220 230 235 250 Other sizes on request. Core identification Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.... The pairs are covered by a numbered tape (1, 2, 3, 4, 5....) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Tel. +31 (0) 183 - 617 109, Fax +31 (0) 183 - 614 087, www.helmacab.nl Technische wijzigingen voorbehouden | Aan deze informatie kunnen geen rechten worden ontleend Subject to technicaI modifications I No rights can be derived from this information
© Copyright 2026 Paperzz