Triaxial Electrogoniometer for Knee Motion R. Mulligan, N. Alexiades, C. Navickas, J. C. Cao Yao Dept. of Biomedical Engineering, Chemistry and Biological Sciences Stevens Institute of Technology Hoboken, New Jersey 07030 Abstract— There are approximately 1,000,000 total knee replacements conducted annually in the United States. The electrogoniometer provides a unique alternative to current postoperative kinematic analysis techniques through a wearable device that dynamically measures the rotation of the knee in three dimensions during walking. This will replace plastic goniometers that measure ROM statically, and also reduce the need for expensive, off-site gait analysis per patient post-operative rehabilitation, saving time, energy, and money. I. INTRODUCTION Knee pain is one of the most prominent causes of discomfort in an aging population. Total knee replacement surgeries cost about $30,000 and the rehabilitation process takes at least 6 weeks and costs about $1500, depending on the physical therapy program and insurance coverage [1]. If complications occur during the recovery process, a revision surgery would be required to remedy any problems adding to the cost of treatment. Currently, the gold standard device for easily and cheaply measuring the range of motion (ROM) of the knee is a plastic goniometer. This device measures static range of motion measurements while the patient lays in supine and prone positions. A major pitfall of this device is its inability to account for the changes in kinematics due to the kinetics of gait. If additional clinical information is required, the gold standard for accurate and in-depth analysis of the joint is through gait analysis using motion capture technology. While this method is accurate, it is expensive for the patient, costing upwards of $200 per visit, and requires complex and expensive hardware and software to calculate the desired measurements [1]. The innovative design of KNE3-D allows for intra-office monitoring of knee kinematic measurements that are accurate and clinically relevant. The device is easy to use, requires minimal training, and produces immediate results. II. MATERIALS AND METHODS A. Design Parameters Due to the increasing need for knee replacements, the device will be essential for collecting normal walking data from the patient allowing for an in depth comparison between pre and postoperative knee joint kinematics. The use of the device The normal ROM for the knee is 0° to 140° in flexion/extension, -6° to 6° in varus/valgus, and -10° to 30° in internal/external rotation. To accommodate these ranges of motion the device is capable of rotating 180° in each plane. The rotary potentiometers are capable of accurately measuring a range of 270°. B. Prototype Design The electrogoniometer utilizes three rotary potentiometers as depicted in green in Fig. 1. Each potentiometer will measure the rotations in the three axes of flexion/extension, varus/valgus, and internal/external rotation to determine the rotations about the knee center. Fig. 1. Axial Alignment of Potentiometers C. Hardware In order to determine the angular displacement from the change in resistance of the potentiometers, a wheatstone bridge will be constructed. The voltage change across the wheatstone bridge will be measured using a data acquisition system (DATAQ, DATAQ Instruments, Inc., Akron, OH) that connects to a computer where software (WinDAQ, DATAQ Instruments, Inc., Akron, OH) converts the voltage output to the respective angle measurements using prior calibration parameters. clinician may observe flexion-extension while simultaneously observing internal/external rotation and varus/valgus angles. D. Device Fixation The patient will have the device secured to their leg by straps for the superior and inferior components. The inferior portion is secured to the patient using velcro strapping around the lower leg. The goniometer is then aligned with the knee and secured in position by strapping the superior component to the thigh. The potentiometers will be aligned prior to fixation to set an initial reading of zero from all sensors. III. RESULTS A. Anticipated Results The wheatstone bridges will output a voltage reading which will be converted to an angle through a calibration curve. Using these values, a plot of angle versus time will be created in order to provide kinematic data. The flexion/extension plot will show a curve between 0° and 60°, and the other two plots will show a curve with the same period (gait cycle) however with much lower extremes around +10°, the typical values for normal gait. These graphs will be useful in diagnosing knee problems and also keeping track of recovery in a more complete method than traditional goniometers (expected waveforms shown in Fig. 2). IV. DISCUSSION The triaxial electrogoniometer can be worn during normal walking motion and allow for the physician to monitor the knee kinematics in real time under normal loading. This provides an advantage for therapists who can subsequently tailor customized rehabilitation programs based on kinematic functional data. Furthermore, rehabilitation regimens can be adjusted according to patient progress. With respect to postoperative implantation, another advantage of the device is that is could aid in early detection of implant loosening as evidenced by altered kinematic patterns, Conclusion KNE3-D is a low-cost inter-office electronic load bearing kinematic knee goniometer providing 3D range of motion during nonoperative or postoperative rehabilitation. The device is targeted for therapeutic caregivers, insurance companies, and athletic trainers of sports teams to further optimize rehabilitation time. ACKNOWLEDGEMENT We would like to offer our most sincere appreciation to our advisors, Antonio Valdevit, Ph.D. and Dr. John Capo, M.D., for their assistance, guidance, and encouragement throughout this project. REFERENCES Fig. 2: Typical knee angles during gait cycle The design possesses advantages over the traditional goniometric technique. The data provided will be dynamic, load-bearing, and accessible in-office for the physician. Traditional methods do not record load bearing or dynamic data, and the use of such data is limited. Traditional plastic goniometers are accurate, but can be adversely affected by poor user alignment upon the knee. Traditional goniometers are affected by the fact that they are static and, only measure one kinematic plane. The KNE3-D goniometer will provide dynamic data under load bearing conditions and output graphically the angles on a computer screen where the [1] BlueCross Blue Shield, “Cost Estimator” 25 Jan. 2017. [2] Chao, E. Y. (1980). Justification of triaxial goniometer for the measurement of joint rotation. Journal of Biomechanics, 13(12), 989-1006. doi:10.1016/0021-9290(80)90044-5 [3] Lavernia, Carlos, MD, et al. "The Increasing Financial Burden of Knee Revision Surgery in the United States." Clinical Orthopaedics and Related Research (2008): n. pag. The-Increasing-Financial-Burden-of-Knee-Revision-in-the-United-St ates1.pdf. Larkin Hospital, 2006. Web. 26 Oct. 2016. . [4] Losina, Elena, et al. "The Dramatic Increase in Total Knee Replacement Utilization Rates in the United States Cannot Be Fully Explained by Growth in Population Size and the Obesity Epidemic" J Bone Joint Surg., 1 Feb. 2012. Web. 10 Oct. 2016.
© Copyright 2026 Paperzz