PINNACLE REVISION CUP SYSTEM ® A new vision in revision acetabular reconstruction DESIGN RATIONALE FLEXIBILITY. PRECISION. CONFIDENCE. ePuy Synthes Joint Reconstruction is proud to offer the PINNACLE® D Revision Acetabular Cup System to address the need for enhanced stability and biomechanical optimization while providing immediate and long-term fixation. The PINNACLE Revision Acetabular Cup System was designed to deliver intraoperative flexibility with precision-crafted components to address the unique challenges of revision acetabular surgery. The PINNACLE Revision Acetabular Cup System consists of the Standard Profile, Deep Profile (DPx) and a Multi-hole shell that feature: • A llowance for mechanical fixation in the rim or dome • D ome screw holes that can angulate up to 34 degrees designed for intraoperative flexibility and optimal bony purchase • T he patented VIP taper that accommodates multiple bearing options to address a wide array of patients, activity levels and demand requirements • Available sizes ranging from 38 to 80 mm Designed in consultation with: William Barrett, MD, Seattle WA Associate Clinical Professor University of Washington Daniel Berry, MD, Rochester MN Associate Professor of Orthopedics Mayo Medical Center Gregory Brick, MD, Boston MA Assistant Clinical Professor Harvard Medical School John Callaghan, MD, Iowa City IA Professor, Dept of Orthopaedics University of Iowa Michael Christie, MD, Nashville TN Co-director, Southern Joint Replacement Institute Charles Engh, MD, Alexandria VA Clinical Associate Professor University of Maryland School of Medicine Thomas Fehring, MD, Charlotte NC Co-director, Charlotte Hip & Knee Center Charlotte Orthopedic William Griffin, MD, Charlotte NC Co-director, Charlotte Hip & Knee Center Charlotte Orthopedic 2 DePuy Synthes Joint Reconstruction PINNACLE Revision Cup System Design Rationale FIXATION: IMMEDIATE & LONG-TERM Standard and Deep Profile (DPx) shells feature: • A full 180-degree hemisphere for rim friction fit designed to enhance immediate cup stability • Deep Profile (DPx) shells with variable, progressive lateralization that increases with shell size to provide proper medial defect fill in a graduated proportional manner • Multiple peripheral and dome screw holes for immediate fixation • Superiorly clustered dome screw holes for precise bone screw positioning into the best quality host bone • Peripheral screw holes for fixation while complementing the natural compressive loading of the acetabulum GRIPTION® Porous Coating GRIPTION is specifically engineered to maintain mechanical integrity under shear, compression, torsion and tension forces. This advanced, three-dimensional fixation is designed to maximize initial stability, which leads to long-term biologic fixation.1 GRIPTION further enhances the solid foundation of DePuy Synthes Joint Reconstruction POROCOAT® Porous Coating, which has more than 30 years of clinical heritage. OPTIONS FOR MODULARITY & BIOMECHANICS: INTRAOPERATIVE FLEXIBILITY TO MATCH YOUR PATIENT’S NEED Neutral ALTRX® ALTRA-LINKED™ Polyethylene Liners are designed to optimize the range of motion by its wide face chamfer while keeping the femoral heads center of rotation concentric with the outer diameter of the shell. +4 Neutral ALTRX ALTRA-LINKED Polyethylene Liners are designed to enhance hip stability, by lateralizing the femoral head’s center of rotation by 4mm. +4 10 Degree ALTRX ALTRA-LINKED Polyethylene Liners are designed to re-direct the available range of motion and optimize positioning to allow the cup, screw holes and GRIPTION Porous Coating to come into contact with the most optimal surface area of the acetabulum. Lipped ALTRX ALTRA-LINKED Polyethylene Liners are designed to provide a high wall along one side of the liner to increase the jump distance in the specific area that the head must travel before dislocation can occur. 4mm of additional lateralization Apex Peak of Angle Face (Not Lipped) Changes Cup inclination/version by 10 degrees dependent on placement of liner Apex Lip to be positioned superior/posterior PINNACLE DPX SHELLS Providing the ability to reproduce the correct center of rotation The ability to reproduce the center of rotation is further enhanced with the deep profile cup. The PINNACLE deep profile shells allow the surgeon to address soft tissue laxity through a proportionally variable offset DPx cup. DPx Cup Size (mm) Lateralization (mm) 54-58 4 60-66 5 6 68-72 Standard Profile 4 DePuy Synthes Joint Reconstruction PINNACLE Revision Cup System Design Rationale Deep Profile ENHANCED STABILITY LINERS DePuy Synthes Joint Reconstruction PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and mechanical fixation alternatives and advanced bearing technologies. The PINNACLE ESC™ Constrained Liner system addresses hip instability and dislocation through dislocation resistance and high range of motion with simple, reproducible insertion instruments. Our unique approach to modularity gives you many ways to bring together components and materials for optimized performance. The ESC liner uniquely addresses these concerns by maximizing the head size for each shell size, offering the patient enhanced range of motion, while maintaining polyethylene thickness for implant survivability. The large femoral head coupled with the titanium constraining ring help to minimize potential lever out. Additional features of the ESC Constrained Liner includes: • High strength head capture • Compatible with bi-polar or modular heads • +4 Neutral and +4 10° options • Up to 113° range of motion2 The ESC liner provides another option with the PINNACLE Revision cup system. • GVF polyethylene for enhanced mechanical integrity ARD (anti-rotational device) tabs for rotational stability. Chamfered titanium constraining ring provides ease of assembly and increased stability. Titanium locking ring securely holds the ESC liner into the Pinnacle shell to minimize potential disassembly. Ridge to aid in preventing constraining ring slippage. Progressively larger ID sizes provide up to a 113-degree range of motion.2 GVF polyethylene for enhanced mechanical integrity. Poly slits and a flex groove for ease of head insertion. Design Rationale PINNACLE Revision Cup System DePuy Synthes Joint Reconstruction 5 ORDERING INFORMATION ESC CONSTRAINED LINER ACETABULAR CUP STYLE Cat. No. Outer Diameter (mm) Acetabular Liner Size Required (mm) Dome Screw Hole Qty. Peripheral Screw Hole Qty. 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 5 6 6 6 6 8 10 10 12 12 12 12 12 12 12 12 12 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 5 5 5 5 9 9 9 9 9 9 9 9 9 8 8 8 8 8 8 8 8 8 8 8 8 8 8 GRIPTION Standard Profile 1217-16-05454 1217-16-056 56 1217-16-058 58 1217-16-060 60 1217-16-062 62 1217-16-06464 1217-16-066 66 1217-16-068 68 1217-16-070 70 1217-16-072 72 1217-16-074 74 1217-16-076 76 1217-16-07878 1217-16-080 80 48 50 52 54 56 58 60 62 64 66 70 72 74 76 GRIPTION Deep Profile DPx 1217-17-054 1217-17-056 1217-17-058 1217-17-060 1217-17-062 1217-17-064 1217-17-066 1217-17-068 1217-17-070 1217-17-072 54 56 58 60 62 64 66 68 70 72 Description Neutral+4 GRIPTION Multi-hole II 1217-30-03838 1217-30-04040 1217-30-04242 1217-30-04444 1217-30-04646 1217-30-04848 1217-30-05050 1217-30-05252 1217-30-05454 1217-30-05656 1217-30-05858 1217-30-06060 1217-30-06262 1217-30-06464 1217-30-06666 1217-30-06868 1217-30-07070 1217-30-07272 Cat. No. 48 50 52 54 56 58 60 62 64 66 5 5 5 5 5 9 9 9 9 9 8 8 8 8 8 8 8 8 8 8 1218-28-648 1218-28-650 1218-32-652 1218-32-654 1218-32-656 1218-32-658 1218-32-660 1218-32-662 1218-32-664 1218-32-666 1218-32-668 1218-32-670 1218-32-672 1218-36-656 1218-36-658 1218-36-660 1218-40-662 1218-40-664 1218-40-666 1218-40-668 1218-44-670 1218-44-672 1218-44-674 1218-44-676 Cat. No. Description 10 Degree+4 28ID 48OD 28ID 50OD 32ID 52OD 32ID 54OD 32ID 56OD 32ID 58OD 32ID 60OD 32ID 62OD 32ID 64OD 32ID 66OD 32ID 68OD 32ID 70OD 32ID 72OD 36ID 56OD 36ID 58OD 36ID 60OD 40ID 62OD 40ID 64OD 40ID 66OD 40ID 68OD 44ID 70OD 44ID 72OD 44ID 74OD 44ID 76OD 1218-28-748 1218-28-750 1218-32-752 1218-32-754 1218-36-756 1218-36-758 1218-36-760 1218-40-762 1218-40-764 1218-40-766 1218-40-768 1218-44-770 1218-44-772 1218-44-774 1218-44-776 28ID 48OD 28ID 50OD 32ID 52OD 32ID 54OD 36ID 56OD 36ID 58OD 36ID 60OD 40ID 62OD 40ID 64OD 40ID 66OD 40ID 68OD 44ID 70OD 44ID 72OD 44ID 74OD 44ID 76OD 5.0 MM PERIPHERAL CORTICAL BONE SCREW 6.5 MM CANCELLOUS DOME SCREW Cat. No. Cat. No. Length (mm) Length (mm) 1257-25-00025 1217-08-5008 1257-30-00030 1217-15-50015 1257-35-00035 1217-20-50020 1257-40-00040 1217-25-50025 1257-45-00045 1217-30-50030 1257-50-00050 1217-35-50035 1257-55-00055 1217-40-50040 1257-60-00060 1217-45-50045 1257-65-00065 1217-50-50050 6 DePuy Synthes Joint Reconstruction PINNACLE Revision Cup System Design Rationale 1217-55-50055 1217-60-50060 1217-65-50065 1217-70-50070 References 1. Jasty M, et al. “In Vivo Skeletal Responses to Porous-Surfaced Implants Subjected to Small Induced Motions.” J Bone Joint Surg Am. 1997;79(5):707-714. 2. Data on file at DePuy Orthopaedics, Inc. WARNING: In the USA, this product has labeling limitations. See package insert for complete information. CAUTION: USA Law restricts these devices to sale by or on the order of a physician. Not all products are currently available in all markets. DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46582 T. +1 (800) 366-8143 www.depuysynthes.com © DePuy Synthes Joint Reconstruction, a division of DOI 2013. All rights reserved. 0612-03-503 (Rev. 2) 11/13 1M
© Copyright 2026 Paperzz